Configuring Historian Servers in High Availability Mode  Appendix A 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
121 
8.
On the Existing Or New Primary page, select A newly 
installed Historian Server, and click Next. 
The Select Primary and Collective Name page appears. 
9.
Review the following for additional information: 
Item name 
Description 
Collective 
Primary 
From the drop-down list, select the name of the server you 
want to make primary. If the name is not in the list, click 
, and select the server from the Connection Manager 
dialog box. 
Primary 
Description 
(Optional) Type a description of the primary server. 
Collective Name Type a name of the collective. The name must be unique. 
Collective 
Description 
(Optional) Type a description of the collective. 
10.
Click Next. The Select Secondary Servers page appears. 
11.
From the Server drop-down list, select the name of the server 
you want to add as secondary. 
If the name is not in the list, click 
, and select the server 
from the Connection Manager dialog box. 
12.
Click Add to add the selected server to the secondary servers 
list, and click Next. 
13.
On the Select Archives page, select the archives from your 
primary server you want to copy to your secondary server. We 
recommend that you back up all your primary server archives 
onto your secondary server. 
Click Next. 
14.
On the Select Backup Location page, leave the default 
location, or click 
and browse to the location to which you 
want to back up the content of your primary server. 
15.
Click Refresh to check the space available in the selected 
location. Make sure that the space available is larger than the 
space required. 
Convert pdf slides to powerpoint - Library application component:C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF in C#.net, ASP.NET MVC, WinForms, WPF
Online C# Tutorial for Creating PDF from Microsoft PowerPoint Presentation
www.rasteredge.com
Convert pdf slides to powerpoint - Library application component:VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to PDF in vb.net, ASP.NET MVC, WinForms, WPF
VB.NET Tutorial for Export PDF file from Microsoft Office PowerPoint
www.rasteredge.com
Appendix A  Configuring Historian Servers in High Availability Mode 
122 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
Click Next. 
16.
On the Verify Selections page, verify the collective data, and 
click Next. 
The Conversion Progress page displays the status and 
individual steps of the conversion process. Wait until the 
conversion is complete. 
17.
If the Server ID Mismatch dialog box appears, select Accept 
the new ID, and click OK. 
18.
On the Finished page, click Finish. The new collective is 
displayed in the Collective Manager dialog box. 
TIP 
For more information on collectives, refer to the Collective 
Manager Help. To access it, select Help > Contents from the 
menu bar of the Collective Manager dialog box. 
Use the Collective Manager to verify that the members of your 
server collective are communicating. 
To check communication of the members of a server collective: 
1.
Click Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > FactoryTalk Historian SE System > Collective 
Manager. The Collective Manager dialog box appears. 
If the server collective does not appear under Collectives, you 
must enable communication between the Collective Manager 
and the collective: 
1.
Select File > Connections. The Connection Manager 
dialog box appears. 
2.
Click the check box next to the name of the server collective 
to select it. 
Verifying Communication 
Between Server Collective 
Members 
Library application component:C# PowerPoint - How to Process PowerPoint
slides sorting library can help you a lot. Extract Slides from PowerPoint in C#.NET. Use C# sample code to extract single or several
www.rasteredge.com
Library application component:VB.NET PowerPoint: Read, Edit and Process PPTX File
split PowerPoint file, change the order of PPTX sildes and extract one or more slides from PowerPoint How to convert PowerPoint to PDF, render PowerPoint to
www.rasteredge.com
Configuring Historian Servers in High Availability Mode  Appendix A 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
123 
If the server collective is not listed in the Connection 
Manager, add it: 
1.
Select Server > Add Server. 
2.
In the Network Node text box, type the fully qualified 
domain name (FQDN) for the primary server in the 
collective. 
3.
Click OK. 
3.
Select the server collective. 
4.
Click Save to close the Connection Manager. 
2.
Under Collectives, select your server collective. 
The right pane of the dialog box displays the current status of 
the connection between the members of the selected server 
collective. The Collective Manager shows a diagram of server 
collective members. An icon represents each server in the 
collective. A green check mark on the icon indicates that the 
server is communicating correctly. A red x mark indicates that 
the server is not communicating correctly. 
If a server icon is not communicating correctly, you can: 
Wait a few moments. Occasionally, the status of the 
secondary server will get updated at the next attempt to 
synchronize. 
Try to reinitialize the server. To do so, right-click the server 
icon and select Reinitialize Server. 
Library application component:VB.NET PowerPoint: Process & Manipulate PPT (.pptx) Slide(s)
add image to slide, extract slides and merge library SDK, this VB.NET PowerPoint processing control powerful & profession imaging controls, PDF document, image
www.rasteredge.com
Library application component:VB.NET PowerPoint: Sort and Reorder PowerPoint Slides by Using VB.
clip art or screenshot to PowerPoint document slide large amount of robust PPT slides/pages editing powerful & profession imaging controls, PDF document, image
www.rasteredge.com
Appendix A  Configuring Historian Servers in High Availability Mode 
124 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
To verify that a Historian server collective replicates primary server 
configuration changes to all secondary servers, you can edit a point 
on the primary server and verify the change on the secondary server 
in the collective. 
To verify configuration replication in a Historian server 
collective: 
1.
Click Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > System Management Tools. The System 
Management Tools dialog box appears. 
2.
Under Collectives and Servers, select all the servers that are 
members in the collective. 
3.
Under System Management Tools, select Points > Point 
Builder. 
4.
Add a point found in all the servers to the list of points: 
1.
On the toolbar, click 
. The Tag Search dialog box 
appears. 
2.
In Tag Mask, type sinusoid. 
3.
Click Search to find all instances of this built-in point on 
the selected servers. 
4.
Click Select All to choose all instances. 
5.
Click OK to add these points to the list of points in the 
Point Builder. 
5.
Edit the point on the primary server: 
1.
Select the point on the primary server. 
The Point Builder shows the configuration of the selected 
point in the tabs at the bottom of the System Management 
Tools dialog box. 
Verifying Replication of 
Configuration Changes in 
the Primary Server 
Library application component:VB.NET PowerPoint: Use PowerPoint SDK to Create, Load and Save PPT
Besides, users also can get the precise PowerPoint slides count as soon as the PowerPoint document has been loaded by using the page number getting method.
www.rasteredge.com
Library application component:VB.NET PowerPoint: Extract & Collect PPT Slide(s) Using VB Sample
want to combine these extracted slides into a please read this VB.NET PowerPoint slide processing powerful & profession imaging controls, PDF document, image
www.rasteredge.com
Configuring Historian Servers in High Availability Mode  Appendix A 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
125 
2.
In the General tab, change the text in the Descriptor text 
box. For example, change 12 Hour Sine Wave to 12-hour 
sine wave. 
3.
Click 
The Point Builder shows the updated Descriptor text for 
this point on the primary server. 
6.
Click 
If the replication is working properly, the modified 
Descriptor text appears for the sinusoid point on all the 
servers in the collective. 
If the replication fails, refer to the FT Historian High 
Availability Administrator Guide, section "Historian 
Collective Health". 
NOTE 
In order to assign the activations to a FactoryTalk Historian SE server, 
the server must be added to the FactoryTalk Directory. See "Adding the 
Server to the FactoryTalk Directory (page 75)" for more information. 
Depending on the type of license activations, you may need to 
acquire a single or double number of license activations of a given 
type for your Historian server collective. 
For the following license activations, you need a single 
activation of a given type for both servers in a collective: 
FHSE.Advanced 
FHSE.H2H 
FTBAInt.* 
AVIEW.* 
NOTE 
The asterisk (*) stands for any count of FTBAInt and AVIEW 
license activations. 
If you assign any of the license activations listed above to a 
Historian server collective, the primary server retrieves (checks 
out) the license activations from the FactoryTalk Activation 
Assigning License 
Activations to Server 
Collectives 
Library application component:VB.NET PowerPoint: Merge and Split PowerPoint Document(s) with PPT
of the split PPT document will contain slides/pages 1-4 code in VB.NET to finish PowerPoint document splitting If you want to see more PDF processing functions
www.rasteredge.com
Library application component:VB.NET PowerPoint: Complete PowerPoint Document Conversion in VB.
It contains PowerPoint documentation features and all PPT slides. Control to render and convert target PowerPoint or document formats, such as PDF, BMP, TIFF
www.rasteredge.com
Appendix A  Configuring Historian Servers in High Availability Mode 
126 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
server to be used by both servers in a collective. In the 
FactoryTalk Activation Manager, the number of activations in 
use is reflected only for the primary server in a collective. It is 
because the assignment of activations to the secondary server 
in a collective is performed outside the FactoryTalk Activation 
mechanism. 
For example, if you want to assign 1 license activation of type 
FHSE.H2H to your Historian server collective, you need to 
acquire 1 license activation of this type and then assign it to 
the primary server in your collective. 
For all other license activations, you need a separate activation 
of a given type for each server in a collective. 
If you assign any license activations other than those listed 
above to a Historian server collective, the primary server 
retrieves (checks out) the license activations from the 
FactoryTalk Activation, and the second license activation of 
the same type is automatically checked out for the secondary 
server in a collective. In the FactoryTalk Activation Manager, 
the number of activations in use is reflected for both servers in 
the collective. 
For example, if you want to assign 2 license activations of type 
FHLD.5000 to your Historian server collective, you need to 
acquire 4 license activations of this type and then assign 2 
activations to the primary server. The other 2 activations will 
be automatically assigned to the secondary server in your 
collective. You will be able to assign license activations of a 
given type to your server collective only if you have a sufficient 
number of them available. 
Library application component:VB.NET PowerPoint: Convert & Render PPT into PDF Document
Using this VB.NET PowerPoint to PDF converting demo code below, you can easily convert all slides of source PowerPoint document into a multi-page PDF file.
www.rasteredge.com
Library application component:VB.NET PowerPoint: Add Image to PowerPoint Document Slide/Page
insert or delete any certain PowerPoint slide without methods to reorder current PPT slides in both powerful & profession imaging controls, PDF document, tiff
www.rasteredge.com
Configuring Historian Servers in High Availability Mode  Appendix A 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
127 
To assign license activations to the primary server in a collective: 
1.
Go to Start > All Programs > Rockwell Software > FactoryTalk 
Administration Console. 
2.
In the Select FactoryTalk Directory dialog box, select 
Network and click OK. 
3.
In the Explorer tree, expand System > Connections > 
Historical Data. 
4.
Right-click the name of the server to which you want to assign 
the license activations, and click Properties. 
5.
In the Historian Server Connection Properties dialog box, 
click the Licensing tab. The table in the tab lists the types and 
number of activations available for the selected server. 
6.
To assign a license activation to the server, type a number in 
the Assigned column for the selected license activation. The 
number shows how many licenses of the selected type will be 
assigned to the server. 
Appendix A  Configuring Historian Servers in High Availability Mode 
128 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
If you have an insufficient number of the license activations 
that need to be assigned separately to the primary and 
secondary server in a collective, you are prompted to reassign 
the licenses. 
7.
Click Apply. The license activations are saved. 
To implement HA, configure interfaces to support failover and 
n-way buffering. Failover ensures that time-series data reaches the 
Historian server even if one interface fails; n-way buffering ensures 
that identical time-series data reaches each Historian server in a 
collective. 
To support failover, install a redundant copy of an interface on a 
separate computer. When one interface is unavailable, the 
redundant interface automatically starts collecting, buffering, and 
sending data to the Historian server. To support n-way buffering, 
configure the buffering service on interface computers to queue data 
independently to each Historian server in a collective. 
In some deployments, interfaces send outputs (that is, data from the 
Historian server) to the data source. With a proper configuration, 
failover considers the availability of the Historian server for outputs 
in addition to the availability of the interface. 
NOTE 
For more information, refer to the FT Historian High Availability 
Administrator Guide, chapter "Interfaces". 
Configuring Interfaces and 
Buffering Services for 
Historian Server Collectives 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
129 
Appendix B 
Configuring Live Data Interface 
Redundancy 
For detailed information on the installation and configuration of 
the interface redundancy, refer to the KB article 59932 
(https://rockwellautomation.custhelp.com/app/answers/detail/a_i
d/59932). 
Overview 
Appendix B  Configuring Live Data Interface Redundancy 
130 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
Documents you may be interested