Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
71 
NOTE 
To manage security of the Historian server database, you need 
administrative rights to the Historian server. 
To view and manage security privileges of the Historian server 
database: 
1.
Go to Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > System Management Tools. The System 
Management Tools dialog box appears. 
2.
Under Collectives and Servers, select the server for which you 
want to manage security. 
3.
Under System Management Tools, select Security > 
Database Security. 
In the right pane of the dialog box, a list of individual database 
tables is displayed. 
The Security column contains a summary of security-related 
information: a list of the security components (identities, 
users, and/or groups) assigned to the database table, and their 
rights displayed in brackets. 
Managing Security of the 
Historian Server Database 
How to convert pdf to powerpoint on - software application dll:C# Create PDF from PowerPoint Library to convert pptx, ppt to PDF in C#.net, ASP.NET MVC, WinForms, WPF
Online C# Tutorial for Creating PDF from Microsoft PowerPoint Presentation
www.rasteredge.com
How to convert pdf to powerpoint on - software application dll:VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to PDF in vb.net, ASP.NET MVC, WinForms, WPF
VB.NET Tutorial for Export PDF file from Microsoft Office PowerPoint
www.rasteredge.com
Chapter 6  Configuring FactoryTalk Historian 
72 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
To modify the type of information displayed, right-click a 
column name and add or remove columns from the context 
menu. 
4.
Right-click the name of the database table for which you want 
to manage the security information, and select Properties. 
The Security for… dialog box appears. 
software application dll:Online Convert PowerPoint to PDF file. Best free online export
Download Free Trial. Convert a PPTX/PPT File to PDF. Then just wait until the conversion from Powerpoint to PDF is complete and download the file.
www.rasteredge.com
software application dll:C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
C# PDF - Convert PDF to JPEG in C#.NET. C#.NET PDF to JPEG Converting & Conversion Control. Convert PDF to JPEG Using C#.NET. Add necessary references:
www.rasteredge.com
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
73 
5.
Click a security component to check its privileges in the 
Permissions for… list. 
You can modify the privileges of the component for the 
database table to the extent that is allowed by the component’s 
configuration. See "Historian Security Components and Their 
Privileges (page 63)" for more information. 
6.
Click OK. 
If you use Microsoft Windows Firewall on the computers on which 
you have installed FactoryTalk Historian SE, the firewall 
configuration is performed automatically during the installation of 
individual FactoryTalk Historian components, using the Rockwell 
Firewall Configuration Utility (WFCU). 
If you use another utility, you need to configure the firewall 
manually following the steps presented below. Refer to the user 
documentation of your firewall configuration utility for more 
information. 
NOTE 
You need administrator privileges to perform the steps described 
below. 
To manually configure the firewall: 
Open TCP/IP ports in the firewall to accept incoming 
connections: 
See the table below to learn which ports need to be open for 
individual FactoryTalk Historian suites. 
For this FactoryTalk 
Historian suite: 
Open these ports: 
Of this type: 
Historian to Historian 
Interface 
5450 
TCP 
Asset Framework 
5457 
5459 
TCP 
TCP 
Configuring Firewall for 
FactoryTalk Historian 
software application dll:VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
Convert PDF to Image; Convert Word to PDF; Convert Excel to PDF; Convert PowerPoint to PDF; Convert Image to PDF; Convert Jpeg to PDF;
www.rasteredge.com
software application dll:VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Convert PDF to HTML. |. Home ›› XDoc.PDF ›› VB.NET PDF: PDF to HTML. Convert PDF to HTML in VB.NET Demo Code. Add necessary references:
www.rasteredge.com
Chapter 6  Configuring FactoryTalk Historian 
74 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
For this FactoryTalk 
Historian suite: 
Open these ports: 
Of this type: 
Historian Server 
5450 
5454 
5455 
5456 
5458 
TCP 
TCP 
TCP 
TCP 
TCP 
Live Data Interface 
6000 
TCP 
Allow FactoryTalk Historian Live Data Interface to 
communicate through the firewall: 
See the table below to learn which settings you need to use 
when configuring the firewall. 
Item 
Description 
The absolute path to 
the Live Data 
interface 
<PIHOME_Value>Interfaces\LDInterface\FTLDInt.exe, 
where <PIHOME_Value> is the path specified in the 
following registry key: 
Computer > HKEY_LOCAL_MACHINE > Software > 
Wow6432Node > PISystem 
The name (ID) of the 
Live Data interface 
PIUniint Interface to the PI System. 
Network location 
types 
Private and public. 
To check the location of the Live Data interface: 
1.
Open the Windows Registry Editor. 
2.
Go to Computer > HKEY_LOCAL_MACHINE > 
Software > Wow6432Node > PISystem. 
3.
Double-click the PIHOME value and copy the path from 
the value data text box. 
The complete path to the Live Data Interface will consist of 
the following parts: 
The path you get from the registry. 
\Interfaces\LDInterface\FTLDInt.exe 
software application dll:C# powerpoint - Convert PowerPoint to PDF in C#.NET
C# PowerPoint - Convert PowerPoint to PDF in C#.NET. C# Demo: Convert PowerPoint to PDF Document. Add references: RasterEdge.Imaging.Basic.dll.
www.rasteredge.com
software application dll:C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
Convert PDF to HTML. |. C#.NET PDF SDK - Convert PDF to HTML in C#.NET. How to Use C# .NET XDoc.PDF SDK to Convert PDF to HTML Webpage in C# .NET Program.
www.rasteredge.com
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
75 
Example: If the PIHOME value points to the following 
location: 
C:\Program Files (x86)\Rockwell Software\FactoryTalk 
Historian\PIPC\ 
The complete path to the Live Data interface would be: 
C:\Program Files (x86)\Rockwell Software\FactoryTalk 
Historian\PIPC\\Interfaces\LDInterface\FTLDInt.exe 
NOTE 
For more information on firewall configuration, refer to the 
documentation of your firewall. 
In the following sections you will learn how to configure and use 
FactoryTalk Historian SE Server. 
Once the FactoryTalk Historian SE server is installed and running, 
add it to the FactoryTalk Directory. 
To add the FactoryTalk Historian SE server to the FactoryTalk 
Directory: 
1.
Go to Start > All Programs > Rockwell Software > FactoryTalk 
Administration Console. 
2.
In the Select FactoryTalk Directory dialog box, select 
Network, and click OK. 
3.
In the Explorer tree, expand System > Connections. 
4.
Right-click Historical Data and select New Historian Server 
Connection. 
5.
In the New Historian Server Connection dialog box, select 
the name of your FactoryTalk Historian SE server from the 
Server or Collective name drop-down list, and click Test 
Server Connection. 
Configuring the Historian 
Server 
Adding the Server to the 
FactoryTalk Directory 
software application dll:VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
VB.NET PDF - Convert PDF to MS Office Word in VB.NET. VB.NET Tutorial for How to Convert PDF to Word (.docx) Document in VB.NET. Best
www.rasteredge.com
software application dll:VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.
VB.NET PDF - Convert PDF to TIFF Using VB in VB.NET. Free VB.NET Guide to Render and Convert PDF Document to TIFF in Visual Basic Class.
www.rasteredge.com
Chapter 6  Configuring FactoryTalk Historian 
76 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
If the connection is successful, the Server found message 
appears next to the Test Server Connection button. 
If the connection is not successful, the No server found 
message appears next to the Test Server Connection 
button. In such a case, check the status of your server in the 
Connection Manager. 
6.
Click Finish. The new server connection with the default Live 
Data interface instance FTLD1 appears under the Historical 
Data folder. 
The local interface is now configured to start collecting data points 
from any data servers that are available to the FactoryTalk Historian 
SE server. 
For more information on the FactoryTalk Historian Live Data 
Interface, see "Configuring FactoryTalk Historian Live Data 
Interface (page 98)". 
If you want to verify if the FTLD interface is properly configured, 
see "Verifying the FactoryTalk Historian Live Data Local Interface 
(page 77)". 
IMPORTANT 
You can use the local interface for data collection. However, we 
strongly recommend that you create a remote interface on the 
computer that has the data server installed. Buffering, which 
ensures that the loss of data does not occur, can only be enabled on 
a remote interface. To learn more about buffering, see "Enable 
Buffering (page 100)". 
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
77 
To verify that the local interface is configured: 
1.
Go to Start > All Programs > Rockwell Software > FactoryTalk 
Administration Console. The FactoryTalk Administration 
Console appears. 
2.
In the Select FactoryTalk Directory dialog box, select 
Network, and click OK. 
3.
In the Explorer tree, expand System > Connections > 
Historical Data, and the FactoryTalk Historian SE server 
node. 
4.
Right-click FTLD1, and select Properties. The Data 
Collection Interface Properties dialog box appears. 
5.
Go to the General tab, and verify in the Service Status section 
that the Startup Type is set to Automatic. 
6.
To start the data collection service, click Start and wait until 
the service status changes to Started. For more information, 
click the help icon in the dialog box. 
7.
Click OK to close the dialog box. 
Once you have your activations, you can assign them to your 
Historian server, and allocate tag counts to selected interface types 
(or point sources). 
See the following topics for more information: 
Types of Licenses (page 78) 
Using the General License Pool (page 80) 
Assigning License Activations to FactoryTalk Historian SE 
Server (page 85) 
Allocating Licenses to Interface Types (page 86) 
Viewing Allocated Licenses (page 88) 
Verifying the FactoryTalk 
Historian Live Data Local 
Interface 
Managing Licenses 
Chapter 6  Configuring FactoryTalk Historian 
78 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
The license activations you get for your Historian server are various 
types of licenses that you can use in either of the following pools of 
licenses: 
Rockwell 
Groups license activations for Rockwell sources only. 
General 
Groups license activations for tags from both Rockwell and 
third-party devices. 
You may use the following license activations with your FactoryTalk 
Historian: 
Type of license 
activation 
Point sources  Description 
FHSE.XXX 
FTLD 
FactoryTalk Live Data connector interfaces. 
FTMS 
Points transferred from a FactoryTalk Historian 
ME module. 
FHSE.H2H 
FHSS 
FactoryTalk Server to Server interfaces. 
The license sets the number of points from the 
FHSS interface to unlimited. 
Types of Licenses 
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
79 
Type of license 
activation 
Point sources  Description 
FTHSE.Advanced 
not applicable  Activates the following Advanced Server 
components for the standard FactoryTalk 
Historian SE server: 
ACE Advanced Computation Engine for 
Visual Basic calculations on Historian data 
Data Access 
JDBC Data Provider 
ODBC 
OLE DB Provider 
OPC DA Server 
OPC HDA Server 
OPC HDA DA Server 
WebServices 
Notifications for using Microsoft Lync 
Unified Communication Server 
Note: For the users upgrading their license 
activations from FactoryTalk Historian SE 
2.2/2.1, the Advanced Server components are 
activated automatically when the total license 
count of the FHLD and PTY3 license activations is 
at least 250. 
FTBAInt.XXX 
FTBOINT 
PIFTBOINT 
FactoryTalk Batch Interface. The license sets the 
number of points from the FTBOINT AND 
PIFTBOINT interfaces to unlimited. 
FHSE3ADD.XXX 
Third-party and 
Rockwell point 
sources. 
See "Using the General License Pool (page 80)" 
for details. 
The names of the license activations have the following structure: 
<Type>.<Quantity>, and contain the following information: 
<Type> 
The type of the license activation. 
<Quantity> 
Chapter 6  Configuring FactoryTalk Historian 
80 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
The maximum number of individual licenses that can be 
allocated to an interface type (or point source). Each license 
corresponds to a single point with which the server can collect 
data from the interface. 
For example, for the FTHSE license activation, the quantity 
ranges from 250 to 100K points. 
For some types of license activations, instead of the 
<Quantity> part there is a combination of digits and/or 
characters that further describe the activation, e.g. 
FTHSE.H2H, FTBAInt.1. 
Each license activation contains a number of individual licenses. The 
system distributes the licenses between the Rockwell and General 
license pools, depending on the type of license activations you have. 
When you allocate licenses to interface types (or point sources), you 
take the licenses from either of the license pools. 
To use the licenses: 
1.
Learn how FactoryTalk Historian distributes individual 
licenses between the license pools. (page 80) 
2.
Assign the license activations to your Historian server (page 
85). 
3.
Allocate the individual licenses to interface types (or point 
sources) (page 86). 
When you acquire license activations for your FactoryTalk 
Historian and assign them to your Historian server, the system 
automatically distributes individual licenses from the license 
activations between the General and Rockwell license pools. 
How Licenses Are 
Distributed Between 
License Pools 
Documents you may be interested
Documents you may be interested