generate pdf in mvc using itextsharp : Online pdf to tiff conversion software control dll windows azure asp.net web forms JLER-7YYLX3_R6_EN22-part1386

"Choose RMS Settings Type" display
Use this display to select whether you want to register a RMS customer for the
StruxureWare Data Center Expert Server for the first time ( New Customer), or to access
the settings for any existing RMS customer ( Existing Customer).
Note:  You cannot register more than one RMS customer for a  StruxureWare Data Center
Expert server, or other device.
"RMS Logon Settings" display
Use this display to access an existing RMS customer's settings by providing that
customer's  E-mail address and  Password, whether that customer was registered for
the  StruxureWare Data Center Expert server or other device.
Note:  This display only appears when you select Existing Customer in the "Choose RMS
Settings Type" display.
"RMS Contact Information" display
Use this display to configure the contact information, including logon values, for a new or
existing RMS customer.
Note:  All information must be provided, except  Title. No contact information is used by
APC for anything other than providing support for the new or existing RMS customer.
"RMS Company Information" display
Use this display to provide company information for a new or existing RMS customer.
Note:  No contact information is used by APC for anything other than providing RMS
customer support; all information must be provided, except  Address 2.
StruxureWare Data Center Expert 7.2.1
221
Online pdf to tiff conversion - software control dll:C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net, ASP.NET MVC, Ajax, WinForms, WPF
Online C# Tutorial for How to Convert PDF File to Tiff Image File
www.rasteredge.com
Online pdf to tiff conversion - software control dll:VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.net, ASP.NET MVC, Ajax, WinForms, WPF
Free VB.NET Guide to Render and Convert PDF Document to TIFF
www.rasteredge.com
SNMP Device Communication Settings (Device menu)
Provides options used to configure the settings the  StruxureWare Data Center Expert
server uses for FTP and SNMP communication with its monitored SNMP devices.
Device File Transfer Settings option
Use this option to access the "Device File Transfer Settings" display used to manage the
settings the  StruxureWare Data Center Expert server uses for File Transfer Protocol (FTP)
or Secure Copy (SCP) access to APC SNMPv1 and SNMPv3 devices.
"Device File Transfer Settings" display
Use this display to manage the File Transfer Protocol (FTP) or Secure Copy (SCP) access
values for APC SNMPv1 and SNMPv3 devices.
Note:  Functionally identical versions of this display are used by the "SNMPv1/SNMPv3
Device Discovery," "Apply Firmware Updates," and "APC SNMP Device Configuration"
wizard, as well as by  Device File Transfer Settings, an  SNMP Device Communication
Settings option in the  Device menu. A change saved in one display is reflected in all.
• To use FTP for APC SNMP device access, FTP server access must be enabled at
that device.
• To use SCP for APC SNMP device access, Secure Shell version 2 (SSHv2) console
access must be enabled at that device.
Element
Description
List
Lists the access settings the  StruxureWare
Data Center Expert server can use for FTP
or SCP access to its monitored devices.
Username: The username used for access
to a device.
Note:  By default, the  StruxureWare Data
Center Expert server can download
firmware only to devices that use  apc
(lowercase) for the username and password
(the actual password used for device access
is identified in the "Edit Device File Transfer
Settings" display).
IP or IP Range: The IP address, or range of
addresses, at which the access settings
support FTP or SCP communication.
StruxureWare Data Center Expert 7.2.1
222
software control dll:Online Convert PDF file to Tiff. Best free online PDF Tif
Online PDF to Tiff Converter. Download Free Trial. Then just wait until the conversion from PDF to Tiff is complete and download the file.
www.rasteredge.com
software control dll:Online Convert PDF file to Word. Best free online PDF Conversion
Online Tiff to PDF Converter. Convert a Tiff/Tif File to PDF. Just upload your file by clicking on the blue button or drag-and-drop your Tiff or Tif file into
www.rasteredge.com
Element
Description
FTP Port: The port used for FTP access to
a device.
SCP Port: The port used for SCP access to
a device.
Timeout: How long the server will wait
before it considers that an attempt to access
a device has failed.
Retry Limit: How many times the server will
try to access a device, after the initial
attempt failed, before it stops trying to
access that device ( 1, by default).
Protocol: The protocol the transfer settings
set will use to access devices ( FTP only,
SCP only, or  Try SCP, fall back to FTP).
Add
Click to add an access setting to the list.
Edit
Click to edit a selected access setting.
Remove
Click to delete a selected access setting.
"Edit Device File Transfer Settings" display
Use this display to add or edit the settings the  StruxureWare Data Center Expert server
uses for File Transfer Protocol (FTP) or Secure Copy (SCP) access to APC SNMPv1 and
SNMPv3 devices.
Note:  Functionally identical versions of this display can be accessed from the "Device File
Transfer Settings" displays used by the "Apply Firmware Updates," "SNMPv1/SNMPv3
Device Discovery," and "APC SNMP Device Configuration" wizards, and by  Device File
Transfer Settings, an  SNMP Device Communication Settings option in the  Device
menu.
Element
Description
Username
Identify the name used for access to a device.
Password
Identify the password used for access to a
device.
Verify Password
Retype the password.
IP or IP Range
Identify The IP address, or range of addresses,
at which the access settings support FTP or SCP
communication ( *.*.*.*, by default).
Protocol
Identify whether the transfer settings will use FTP
( FTP only), SCP ( SCP only), or attempt to use
SCP, but fall back to using FTP if SCP fails ( Try
SCP, fall back to FTP).
FTP Port
Select the port the server will use for FTP access
to devices ( 21, by default).
SCP Port
Select the port the server will use for SCP access
to devices ( 22, by default).
StruxureWare Data Center Expert 7.2.1
223
software control dll:Online Convert Excel to PDF file. Best free online export xlsx
Online Excel to PDF Converter. Download Free Trial. Your file will then be instantly converted to PDF and ready to download. The perfect conversion tool.
www.rasteredge.com
software control dll:.NET PDF Document Viewing, Annotation, Conversion & Processing
In addition, .NET programming examples for all these functions are provided online. Convert PDF to Word (.docx). Convert PDF to images, like Tiff.
www.rasteredge.com
Timeout
Identify how long the server will wait before it
considers that an attempt to access a device has
failed ( 3000, by default).
Retry Limit
Select the number of times the server will try to
access a device, after the initial attempt failed,
before it stops trying to access that device ( 1, by
default).
Device Scan Settings option
Use this option to manage the settings the  StruxureWare Data Center Expert server uses
for SNMPv1 and SNMPv3 communication with its monitored SNMP devices, as well as
alarm settings the server associates with those devices.
The monitored SNMP devices are listed by  Hostname (or IP address), and the following
information is provided for each:
Device Type
Notification Policy : the notification policy the  StruxureWare Data Center Expert
server associates with alarms at an APC SNMP device.
• Location: the location of the device, if known.
• Protocol:  SNMPv1 or  SNMPv3.
• Port,  Timeout, and  Retries : SNMP communication settings.
• Last Scan Time: date and time when the  StruxureWare Data Center Expert server
last scanned a device for status information.
You can edit the  Notification Policy Port,  Timeout, and  Retries settings, as well as
settings not identified in the list, by selecting one or more of the listed devices and
clicking  Edit Device Scan Settings. The following editable settings are not identified in
the list.
• Scan Interval (minutes)
• Priority Scanning
Note:  Priority Scanning is a trap-based polling process that only occurs in response
to traps from APC SNMPv1 devices or informs from APC SNMPv3 devices at which
the  StruxureWare Data Center Expert server is defined as a trap receiver.
• SNMPv1:  Read and  Write Community names
• SNMPv3:  User Authentication Protocol,   Encryption Algorithm , and
Authentication and  Encryption Passwords
Note:  If you select to edit SNMPv1 and SNMPv3 devices at the same time, no
Priority Scanning, SNMPv1-specific, or SNMPv3-specific settings will appear in the
"Edit Device Scan Settings" display.
"Edit Device Scan Settings" display
Use this display to edit notification policy and SNMP communication settings the
StruxureWare Data Center Expert server uses with its monitored SNMP devices.
The display includes elements that are shared by SNMPv1 and SNMPv3 devices, as well
as  SNMP Settings elements that are specific to each protocol.
Note:  If both SNMPv1 and SNMPv3 devices are selected, the  SNMP Settings section will
not appear in this display.
StruxureWare Data Center Expert 7.2.1
224
software control dll:C# Create PDF from Tiff Library to convert tif images to PDF in C#
Online demo allows converting tiff to PDF online. C# source codes are provided to use in .NET class. In addition to PDF to Tiff conversion, our .NET PDF
www.rasteredge.com
software control dll:VB.NET Create PDF from Tiff Library to convert tif images to PDF
online. Source codes are provided to use in VB.NET class. Free library and components for downloading and using in .NET framework. Except PDF to Tiff conversion
www.rasteredge.com
Shared Element
Description
Hostname
When only one device is selected, identifies the
hostname or IP address of that SNMP device.
Note:  No  Hostname is provided when multiple
devices are selected.
Scan Interval (minutes)
Select how much time will pass between
StruxureWare Data Center Expert server scans
of a selected SNMP device for status information:
from  1 through  60 minutes, and  Default, the
minutes for which is defined by the  Global
SNMP Settings option's  Scan Interval setting.
Note:  Setting the scan interval below the default
value of five minutes can adversely affect
performance when the  StruxureWare Data
Center Expert server is managing a large number
of devices.
Port
The number of the port used for SNMP
communications with a selected SNMP device.
Timeout (seconds)
Select how long the  StruxureWare Data Center
Expert server will wait for a response before it
considers an attempt to communicate with a
selected SNMP device has failed: from  1
through  60 seconds.
Retries
Define how many times the  StruxureWare Data
Center Expert server will attempt to
communicate with a selected SNMP device, after
the initial attempt failed, before it stops trying to
access that device during the current scanning
process.
SNMPv1-specific SNMP Settings
Element
Description
Priority Scanning
Select this option to register the  StruxureWare
Data Center Expert server as a trap receiver at a
selected APC SNMPv1 device. This allows for
faster reporting of errors at that device by the
server.
As a trap receiver for an APC SNMPv1
device, the server will poll the device as
soon as it receives a trap from that device.
As a non-trap receiver, the server reports
device alarms during normal scan intervals
only.
Note:  Priority scanning is a trap-based
polling process that only occurs in response
to traps from APC SNMPv1 devices or
informs from APC SNMPv3 devices.
Read Community
Edit the community name that the server uses to
read information from the SNMPv1 device.
StruxureWare Data Center Expert 7.2.1
225
software control dll:C# TIFF: C#.NET Code to Convert TIFF Image File
Online C# tutorial for high-fidelity Tiff image file conversion from MS Office Word, Excel, and PowerPoint document. Convert PDF to Tiff Using C#.
www.rasteredge.com
software control dll:VB.NET PDF Converter Library SDK to convert PDF to other file
plug-in embeds several image compression mechanisms, it can be used for multiple PDF to image converting applications, like PDF to tiff conversion, PDF to JPEG
www.rasteredge.com
Write Community
Edit the community name that the server uses to
define itself as a trap receiver at a selected
SNMPv1 device.
SNMPv3-specific SNMP Settings
Element
Description
Priority Scanning
Select this option to register the  StruxureWare
Data Center Expert server as a trap receiver at a
selected APC SNMPv3 device. This allows for
faster reporting of errors at that device by the
server.
As a trap receiver for an APC SNMPv3
device, the server will poll the device as
soon as it receives an inform from that
device.
As a non-trap receiver, the server reports
device alarms during normal scan intervals
only.
Note:  Priority Scanning is a trap-based polling
process that only occurs in response to traps
from APC SNMPv1 devices or informs from APC
SNMPv3 devices.
User
Identify the username the server uses for secure
communication with a selected SNMPv3 device.
Authentication Protocol
Change the protocol ( MD5 or  SHA-1), if
necessary, selected for the server to use for
communication with a selected SNMPv3 device.
Authentication Password/Verify
Type in and verify a new password, if necessary,
for the selected  Authentication Protocol.
Encryption Algorithm
Change the encryption method ( None DES ,
or  AES128), if necessary, selected for the server
to use for communication with a selected
SNMPv3 device.
Encryption Password/Verify
Type in and verify a new password, if necessary,
for the selected  Encryption Algorithm .
Device Definition Files option
Use this option to manage the Device Definition Files (DDFs) that the  StruxureWare Data
Center Expert server uses to access information about the environmental, power, and
cooling sensors at supported SNMP devices.
Each DDF file is designed to provide information about sensors for a particular product set
from a specific manufacturer, and contains only the OIDs directly related to that product's
capabilities.
StruxureWare Data Center Expert 7.2.1
226
software control dll:XDoc.Converter for .NET, Support Documents and Images Conversion
Convert Adobe PDF to image. Convert Tiff to image. Convert Word, Excel and PDF to image. Next Steps. Download and try Converter for .NET with online support.
www.rasteredge.com
Element
Description
Device Definition Files
Lists the DDFs already installed at the
StruxureWare Data Center Expert server.
Remove
Click to delete a selected DDF from the list.
Note:  Deleting a DDF will affect what
sensors the SNMP devices related to that
DDF will report.
Add/Update Definitions
Click to access the wizard used to add or
update DDF files, when available from APC.
Adding or updating device definition files (DDFs)
Use the "Add/Update Definitions" wizard to add or update the DDFs available for the SNMP
devices supported by the  StruxureWare Data Center Expert server. The new or updated
DDFs can be uploaded to the  StruxureWare Data Center Expert server from a local file, or
from the APC website.
1. Select  Device Definition Files, an  SNMP Device Communication Settings option
in the  Device menu.
2. Select the  Device Definition Files option in the "SNMP Device Communication
Settings" display.
3. Click  Add/Update Definitions in the  Device Definition Files tab.
4. In the "Select Update Method" display, select the option you want to use to add or
update DDFs, and follow the appropriate instructions.
• To use files from APC, see step 5.
• To use files previously downloaded to a local computer, see step 6.
5. To download files from APC, do the following.
a. Select  Check APC Website and click  Next.
b. In the "Select DDF Files" display, select the files you want to download, click
Next, and go to step 7.
6. To use a local file, do the following.
a. Select  Local File and click  Browse.
b. In the "Open" display, navigate to the file you want to use, and double-click that
file (or click it once, and then click  Open).
c. In the "Select Update Method" display, verify the correct file is identified, click
Next, and go to step 7.
7. In the "Installed/Updated DDF Files" display, verify the files you selected are listed,
and click  Finish, to exit the wizard, or  Back, to return to the "Select Update Method"
display.
"Add/Update Definitions" wizard
This wizard steps you through the process of adding new Device Definition Files (DDFs),
or updating existing files.
"Select Update Method" display
Use this display to select the source of new or updated DDF files.
Element
Description
StruxureWare Data Center Expert 7.2.1
227
Check APC Website
Click to see if any new or updated DDF files are
available from APC.
Local File
Click to download a DDF file stored on a local
computer.
Browse
Click to browse to the DDF file on the local
computer.
"Select DDF Files" display
Use this display to select the DDF files you want to download from APC.
Element
Description
List
Select the DDF files that you want to download
from APC from the list of available DDFs.
Each listing shows the currently installed
version and whether a new or updated
version is available.
Installed: The DDF version matches the
server's file.
Updated: The DDF is an updated version of
the server's file.
New: The DDF file is not installed at the server.
Next
Click to download the selected DDF files.
"Installed/Updated DDF Files" display
Use this display to verify that all DDF files were downloaded successfully.
Global Scan Settings option
Use this option to define the global scan settings that the  StruxureWare Data Center
Expert server will use for its communication with its monitored SNMP devices.
Element
Description
Scan Interval
Select how much time will pass between
StruxureWare Data Center Expert server scans
for status information at a monitored SNMP
device, when the  Device Settings option in the
"SNMP Device Communication Settings display"
has  Default selected for that device's  Scan
Interval (minutes) setting.
Note:  Setting the scan interval below the default
value of five minutes can adversely affect
performance when the  StruxureWare Data
Center Expert server is managing a large number
of devices.
StruxureWare Data Center Expert 7.2.1
228
Supplemental OIDs option
Use this option to add supplemental OIDs that define numeric sensors for monitored SNMP
devices.
Once a supplemental OID has been added, the  StruxureWare Data Center Expert server
will request it for every SNMP device, with the supplemental OID value reported only by
SNMP devices that can report the sensor associated with that OID. This allows the server
to monitor and provide alert notifications for the supplemental OID the same way it does for
any other sensor for SNMP devices.
You use the  Other Numeric Sensors threshold option to configure alert threshold settings
for an SNMP device that has the type of numeric sensor associated with the supplemental
OID.
Note:  To add a supplemental OID, you need access to the Management Information Base
(MIB) that defines the OIDs available to the SNMP device.
Elements
Description
OIDs
Identifies the existing supplemental OIDs.
Sensor Type: The type of numeric sensor
(temperature, humidity, air flow, etc.) that
best matches the data reported by the OID.
Unit of Measure (only available when
Generic is the  Sensor Type): The
appropriate unit or measurement (degrees,
seconds, volts, etc.) used when reporting
the sensor data.
OID: The definition of the OID to be
monitored for an SNMP device (for
example, .1.3.6.1.4.1.318.1.1.1.2.2.2).
Description: A description of the OID (for
example, UPS Temperature).
Add
Click to add a new supplemental OID.
Remove
Click to delete a selected supplemental OID.
"Add" Supplemental OID display
Use this display to add a supplemental OID for an SNMP device.
Note:  To add a supplemental OID, access to the Management Information Base (MIB) that
defines the OIDs available to the SNMP device.
Element
Description
Sensor Type
Select the sensor type.
Unit of Measure
Select the unit of measure, when  Generic is
the  Sensor Type.
StruxureWare Data Center Expert 7.2.1
229
OID
Identify the OID. For example:
.1.3.6.1.4.1.318.1.1.1.2.2.2
Note:  An OID must begin with.1.3.6.1 to be
considered valid.
Description
Identify the description for the OID that will
appear in the display for the  View Device
Sensors right-click option in the  Device View
and  Map View . For example,  UPS
Temperature.
StruxureWare Data Center Expert 7.2.1
230
Documents you may be interested
Documents you may be interested