Click on the MBps field and press “Edit selected label.” ”   Click “Right axis” to  
graph this field on the right axis of the graph.  Change the name to be displayed on 
the Y axis label if you like.  Press OK, then Next.
The grouping criterion can be used to group the data into several distinct lines on 
the graph.  For now, leave “None” selected.   Press Next.
Leave the grouping criterion label blank.  Press Next.
Type a name for the graph type you have just defined, or accept the default.  Press 
Next.  
You have now defined a new graph type that you can edit or re-use in the future. 
Select it from the list (if it isn’t already selected).   Press Next.
Specify an 
.xls
file to receive the graph.  This can be a new or existing file; if 
the file exists, the graph will be added to it.  Press Next.
Review your settings and press Finish.   The graph is created in the specified 
spreadsheet.  (If you just imported the results from one or two tests, it is probably a 
very boring graph with only one or two points!  The Graph Wizard is most useful 
in graphing the results of multiple tests against each other.)
Print pdf to tiff - control SDK platform:C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net, ASP.NET MVC, Ajax, WinForms, WPF
Online C# Tutorial for How to Convert PDF File to Tiff Image File
www.rasteredge.com
Print pdf to tiff - control SDK platform:VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.net, ASP.NET MVC, Ajax, WinForms, WPF
Free VB.NET Guide to Render and Convert PDF Document to TIFF
www.rasteredge.com
5.
Using Iometer
This section provides an introduction to Iometer’s graphical user interface.   Complete 
details on each component are provided later in the document.
The Iometer user interface has the following major components:
Toolbar
: Performs common operations such as starting and stopping tests.
Status bar
: Shows which test in a test series is currently running.
Topology
panel:   Displays  the   available   managers   (Dynamos)   and   workers 
(threads).   Actions in the  toolbar, Disk  Targets, Network  Targets, and  Access 
Specifications tabs apply to the manager(s) or worker(s) selected in this panel, and 
this panel is used to select managers and workers for the Results Display tab.
Tabbed panels: Several different tabs to control the parameters of the test:
¾
Disk Targets
tab: Specifies the disks used by each disk worker.
¾
Network Targets
tab: Specifies the network interfaces used by each network 
worker.
¾
Access Specifications
tab: Specifies the type of I/O operations each worker 
performs to its targets.
¾
Results Display
tab: Displays performance data during the test.
¾
Test Setup
tab: Specifies the tests to be performed in a test series.
Each of these components is described in the following pages.  For complete details on 
each component, see the corresponding Reference section later in this document.
control SDK platform:C# PDF Print Library: Print PDF documents in C#.net, ASP.NET
Annotate PDF. WPF: Export PDF. WPF: Print PDF. PDF Create. Create PDF from Word. Create PDF from Excel. Create PDF from PowerPoint. Create PDF from Tiff. Create
www.rasteredge.com
control SDK platform:VB.NET PDF Print Library: Print PDF documents in vb.net, ASP.NET
Annotate PDF in WPF. Export PDF in WPF. Print PDF in WPF. PDF Create. Create PDF from Word. Create PDF from Excel. Create PDF from PowerPoint. Create PDF from Tiff
www.rasteredge.com
5.1
Toolbar — Introduction
The toolbar provides buttons for common commands.  
Open Test Configuration File  — Restores a previously-saved set of test  
configuration parameters from a file.  See the Open Test Configuration File –
Introduction
section for further details.
Save  Test   Configuration   File — Saves the current test configuration  
parameters to a file.   See  the  Save Test Configuration File – Introduction
section for further details.
Start New Manager — Starts a new manager (copy of Dynamo) on the  
machine Iometer is running on.
Start Disk Worker — Starts a new disk worker (thread) in the manager  
selected in the 
Topology
panel.
Start Network  Worker — Starts a new network server (thread) in the  
manager selected in the 
Topology
panel.
Duplicate  Selected  Worker — Starts an exact duplicate of the worker  
selected in the 
Topology
panel, on the same manager.
Start Tests — Starts a series of tests.   Prompts for a file to save the test 
results.
Stop Current Test and Save Results — Stops the currently-running test,  
saving its results, and begins running the next test in the current series.
Abort All Tests — Stops the currently-running test, discarding its results.   No 
more tests are run.  
Reset Workers — Resets the worker configuration of all managers to the  
default state.
Disconnect Selected Worker or Manager — Terminates the worker(s) or  
manager(s) selected in the 
Topology
panel.
Exit — Terminates Iometer and all connected Dynamo processes.
About Iometer — Displays version and copyright information for Iometer.
For complete details, see the 
Toolbar — Reference
section later in this document.
control SDK platform:C# Create PDF from Tiff Library to convert tif images to PDF in C#
Create PDF from Tiff. |. Home ›› XDoc.PDF ›› C# PDF: Create PDF from Tiff. C#.NET PDF - .NET PDF Library for Creating PDF from Tiff in C#.
www.rasteredge.com
control SDK platform:VB.NET PDF - Print PDF with VB.NET WPF PDF Viewer
Annotate PDF in WPF. Export PDF in WPF. Print PDF in WPF. PDF Create. Create PDF from Word. Create PDF from Excel. Create PDF from PowerPoint. Create PDF from Tiff
www.rasteredge.com
5.2
Status Bar — Introduction
Whenever you press the Start Tests button, Iometer runs a series of tests, as specified 
by the  
Access Specifications
and  
Test Setup
tabs.   Each access specification is run 
once; each test is run once for each access specification.  The current test number and 
the total number of tests to be run are displayed in the status bar at the bottom of the 
Iometer window.  
For complete details, see the 
Status Bar — Reference
section later in this document.
control SDK platform:C# WPF PDF Viewer SDK to view, annotate, convert and print PDF in
as well. Users can export and convert PDF to Word, Tiff, TXT and various of image file formats. Print PDF in WPF PDF Viewer. By using
www.rasteredge.com
control SDK platform:C# WPF PDF Viewer SDK to print PDF document in C#.NET
Annotate PDF. WPF: Export PDF. WPF: Print PDF. PDF Create. Create PDF from Word. Create PDF from Excel. Create PDF from PowerPoint. Create PDF from Tiff. Create
www.rasteredge.com
5.3
Topology Panel — Introduction
The Topology panel displays a hierarchical list of managers (Dynamos) and workers 
(threads) currently active.
Click on a worker, manager, or “All Managers” to see and change its settings in  
the 
Disk Targets
Network Targets
, and 
Access Specifications
tabs.  
¾
If you click on a worker, targets (disks or network interfaces) selected in the 
Disk Targets or Network  Targets tab are used  by  that worker.   The other 
controls in the Disk Targets, Network Targets, and Access Specifications tabs 
show current settings for that worker; any changes are applied to that worker.
¾
If you click on a manager, targets selected in the Disk Targets or Network 
Targets tab are distributed in a round-robin fashion among the manager’s disk  
or network workers (as appropriate).  The other controls in the Disk Targets, 
Network Targets, and Access Specifications tabs display the common settings 
of all the manager’s workers of the appropriate type (a value is shown if all  
workers have the same value, or the control is blank if not all workers have the 
same value).  Any changes you make are applied to all the manager’s workers  
of the appropriate type.
¾
If you click on “All Managers,” no targets are shown in the Disk Targets or  
Network  Targets tab, because managers’ target lists may be  different. The  
other controls in the Disk Targets, Network Targets, and Access Specifications 
tabs display the common settings of all workers of the appropriate type; any 
changes you make are applied to all workers of the appropriate type.
Double-click on a manager or “All Managers” to hide or display its children.
Right-click on a manager to update its target lists.
Drag a worker, manager, or “All Managers” to a bar chart in the 
Results Display
tab to see its results as the test is running.
For  complete  details,  see  the  
Topology Panel  — Reference
section  later in  this 
document.
control SDK platform:VB.NET Create PDF from Tiff Library to convert tif images to PDF
Word, C# extract text from PDF, C# convert PDF to Jpeg, C# compress PDF, C# print PDF, C# merge PDF files, C# view PDF online, C# convert PDF to tiff, C# read
www.rasteredge.com
control SDK platform:VB.NET PDF - WPF PDF Viewer for VB.NET Program
annotate PDF document with various notes and shapes, convert PDF to Word document, Tiff image, TXT file and other images file formats, and print PDF document.
www.rasteredge.com
5.4
Disk Targets Tab — Introduction
The Disk Targets tab lets you see and control the disks used by the disk worker(s) 
currently selected in the 
Topology
panel.  
Click,   Shift-click,   and   Control-click   to 
select any number of drives to be used by 
the selected worker(s) during the test.
Physical drives are displayed with a blue 
disk   icon   and   the   name 
“PHYSICALDRIVE: n”   (only   if   they  
contain nothing but free space).
Logical drives are displayed with a yellow 
disk icon and a drive letter and optional 
name (only if they are writable).
Logical drives are accessed by writing to a 
file called  
\iobw.tst
 If this file does 
not exist, the drive’s icon has a red slash  
through it.  At the start of the test the file 
will be created and grown until the disk is 
full.
Running   with   physical   drives   is 
recommended.
Sets the number of sectors used during the 
test (0 = all sectors).  
Sets the starting disk sector used during the 
test (0 =  beginning  of physical  disk or 
iobw.tst
file).
Sets   the   number   of   simultaneous 
outstanding I/Os per disk.
Specifies whether or not each disk should 
be opened and closed repeatedly during the 
test, and sets the  number of transactions 
(request + reply) issued between each open 
and close.
For complete details, see  the  
Disk Targets Tab — Reference
section  later in this 
document.
NOTE
If the total number of outstanding I/Os in the system is very large, Iometer or 
Windows may hang, thrash, or crash. The exact value  of “very  large” ”  
depends on the disk driver and the amount of physical memory available. 
This problem is due to limitations in Windows and some disk drivers, and is 
not a problem with the Iometer software. The problem is seen in Iometer and 
not in other applications because Iometer makes it easy to specify a number 
of outstanding I/Os that is much larger than typical applications produce.
5.5
Network Targets Tab — Introduction
The Network Targets tab lets you see and control the network interfaces used by the 
network server(s) currently selected in the 
Topology
panel. 
Click   to   select   network   interfaces   for 
network server(s) (at most one per server). 
Control-click   to   deselect   the   currently-
selected  interface.   A   network   client   is 
automatically   created   on   the   selected 
manager   to   communicate   through   the 
selected interface on that manager.  
Specifies the network interface used by the 
selected network worker for its end of the 
connection.
Specifies   the   maximum   number   of 
messages a network worker will send to a 
VI   target   before   waiting   for   an 
acknowledgement.
Specifies whether or not the  connection 
should  be  opened  and closed  repeatedly 
during  the  test, and  sets the  number  of 
transactions   (request   +   reply)   issued 
between each open and close.
If a network client is selected in the 
Topology
panel, the Network Targets tab displays 
the client’s configuration, but you cannot change it (a client’s configuration is always  
the same as its server).  If a manager that has network clients is selected, the clients’ 
configuration is not included in the Network Targets tab, and any changes you make in 
the Network Targets tab do not affect the clients.
For complete details, see the  
Network Targets Tab — Reference
section later in this 
document.
5.6
Access Specifications Tab — Introduction
The Access Specifications tab lets you control the type of I/O each worker performs to 
its selected target(s).  Each named access specification controls:
The percent of transfers that are a given size.
What percent of those are reads or writes.
What percent of accesses are random or sequential.
How many transfers occur in a burst.
How long to wait between bursts.
The alignment of each I/O on the disk.
The size of the reply, if any, to each I/O request.
Multiple access specifications can be assigned, resulting in multiple tests being run.
Lists   the  access  specifications  assigned   to   the 
worker(s) selected in the 
Topology
panel.
Copies the selected access specification(s) from 
the Global list to the Assigned list.  You can also 
drag  access specifications  from  one  list to  the 
other.
Removes the selected access specification(s) from 
the   Assigned   list.   You  can   also   drag   access 
specifications out of the list to remove them.
Lists   all   the   currently-defined   access 
specifications.
Documents you may be interested