embed pdf in mvc view : Convert pdf to html online SDK software service wpf winforms windows dnn EX-IQ-BOXK04_OperatingManual_en_0518-part1260

Protocol Settings
R&S®EX-IQ-BOX
165
User Manual 1409.5570.32 ─ 05
Fig. 7-64: CPRI L1 inband protocol
Protocol Version
Indicates the CPRI protocol version.
According to the protocol version, the link supports data scrambling or descrambling, as
shown below.
Note: It is strongly recommended that you use scrambling at higher line bit rates.
Line rate [Mbit/s]
Scrambling support
Highest available protocol ver-
sion number
1x (614.4)
not supported
1
2x (1228.8)
not supported
1
4x (2457.6)
not supported
1
5x (3072.0)
not supported
1
CPRI
Convert pdf to html online - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
how to convert pdf into html; how to convert pdf into html code
Convert pdf to html online - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
convert pdf to html format; convert pdf into webpage
Protocol Settings
R&S®EX-IQ-BOX
166
User Manual 1409.5570.32 ─ 05
Line rate [Mbit/s]
Scrambling support
Highest available protocol ver-
sion number
8x (4915.2)
recommended
1: scrambling not supported
2: scrambling supported
10x (6144.0)
recommended
1: scrambling not supported
2: scrambling supported
16x(9830.4)
recommended
1: scrambling not supported
2: scrambling supported
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​VERSion?​ on page 315
HDLC Rate
Indicates the Slow C&M HDLC bit rate during link setup.
You can determine this parameter in the C&M tab, which is embedded in the CPRI pro-
tocol. RE and REC then read the value of the other, and agree on the smallest.
Supported values depend on the line speed:
Bit rate [Mbit/s]
1x (614.4)
no HDLC
240
480
2x (1228.8)
no HDLC
240
480
960
4x (2457.6)
no HDL
240
480
960
1920
5x (3072.0)
no HDLC
240
480
960
1920
2400
8x (4915.2)
no HDLC
240
480
960
1920
2400
3840
10x (6144.0)
no HDLC
240
480
960
1920
2400
4800
16x (9830.4)
no HDLC
240
480
960
1920
2400
7680
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​HDLC:​BRATe?​ on page 312
Flags
Shows various information about the link status, transmitted in control word 130.
The following flags are defined:
"LOS"
The LOS (Loss of Signal) LED indicates a loss of signal.
"LOF"
LOF (Loss of Frame) indicates, when the received data lost the syn-
chronization, that is loss of frame.
"RAI"
RAI (Remote Alarm Indication) indicates, if any remote part of the end-
to-end link has failed.
"SDI"
SDI (Service Access Point Defect Indication) indicates, that the data
communication failed.
CPRI
Online Convert PDF to HTML5 files. Best free online PDF html
Online PDF to HTML5 Converter. Download Free Trial. Convert a PDF file to HTML. Just upload your file by clicking on the blue button
best pdf to html converter; batch convert pdf to html
VB.NET PDF - Convert PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
how to convert pdf to html; convert pdf to html5 open source
Protocol Settings
R&S®EX-IQ-BOX
167
User Manual 1409.5570.32 ─ 05
"Reset"
Indicates that the DUT is in reset state.
In the CPRI RE test mode, the LED shows that a reset was performed,
and in CPRI REC test mode, the LED indicates a reset request.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​RX:​LOS?​ on page 326
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​RX:​LOF?​ on page 325
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​RX:​RAI?​ on page 326
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​RX:​SDI?​ on page 327
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​RX:​RESet?​ on page 326
Ethernet Pointer
Indicates the resulting Ethernet pointer after the link setup, that means the position after
the handshake between the R&S EXBOX-B85 and the DUT.
You can determine this parameter in the C&M tab, which is embedded in the CPRI pro-
tocol. RE and REC then read the value of the other, and agree on the smallest.
Valid entries range from 20..63. Depending on the line speed and the pointer the following
Ethernet bit rates are achievable:
Line rate
[Mbit/s]
Length of control word
[bit]
min. Ethernet bit rate
[Mbit/s]
max. Ethernet bit rate
[Mbit/s]
1x (614.4)
8
0.48
21.12
2x (1228.8)
16
0.96
42.24
4x (2457.6)
32
1.92
84.48
5x (3072.0)
40
2.40
105.60
8x (4915.2)
64
3.84
168.96
10x (6144.0)
80
4.80
211.20
16x (9830.4)
128
7.86
337.92
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​CM:​ETH:​PTR?​ on page 293
7.2.8.2 Link Status
This section indicates the status of the last query on the active link.
By means of an LED display, R&S DigIConf indicates alarm and error messages as e.g
LOF or LOS. In case of malfunction, the respective LEDs change from blue to red.
Once CPRI is turned on, all parameters are updated continuously. If CPRI is off, the
parameters are set to default value.
Link Status
Indicates whether the CPRI link is established or any transmission error has occurred.
CPRI
C# HTML5 PDF Viewer SDK to convert and export PDF document to
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
convert pdf to website html; add pdf to website
VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
pdf to web converter; how to change pdf to html format
Protocol Settings
R&S®EX-IQ-BOX
168
User Manual 1409.5570.32 ─ 05
This indicator includes all verified transmission parameters.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​ALARm?​ on page 298
Core Mode
Indicates the current state of the CPRI core.
The CPRI core can work in the following states:
CPRI core state
Description
"Link is up"
normal operating mode
"Reset"
at the starting point of establishing the link
"L1 Synchronization"
attempt of L1 synchronization
"Setup protocol version"
setting up the protocol version
"Setup C&M parameter"
setting up the C&M parameter
"Passive mode"
only I/Q data are active, C&M is not used
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​CORE?​ on page 299
CPRI Mode
Displays the role of the R&S EX-IQ-BOX, that is either master (CPRI RE test) or slave
(CPRI REC test).
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​CMODe?​ on page 299
LOF (Loss of Frame)
Indicates whether the CPRI frame delimiter K28.5 is detected.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​LOF?​ on page 306
LOS (Loss of Signal)
Indicates whether the data is synchronized.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​LOS?​ on page 306
Local Alarms
These LEDs indicate if errors occur on the CPRI breakout board.
"LOF"
LOF (Loss of Frame) indicates, when the received data lost the syn-
chronization, that is loss of frame.
"LOS"
The LOS (Loss of Signal) LED indicates a loss of signal.
CPRI
VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.
Resize converted Tiff image using VB.NET. Convert PDF file to Tiff and jpeg in ASPX webpage online. Online source code for VB.NET class.
online convert pdf to html; converting pdf to html format
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
adding pdf to html page; convert pdf to website
Protocol Settings
R&S®EX-IQ-BOX
169
User Manual 1409.5570.32 ─ 05
"RAI"
RAI (Remote Alarm Indication) indicates, if any remote part of the end-
to-end link has failed.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​LOCal:​LOF?​ on page 312
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​LOCal:​LOS?​ on page 312
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​LOCal:​RAI?​ on page 313
Remote Alarms
The LEDs in this section show alarms that the DUT returns via the CPRI link.
"LOF"
LOF (Loss of Frame) indicates, when the received data lost the syn-
chronization, that is loss of frame.
"LOS"
The LOS (Loss of Signal) LED indicates a loss of signal.
"RAI"
RAI (Remote Alarm Indication) indicates, if any remote part of the end-
to-end link has failed.
"SDI"
SDI (Service Access Point Defect Indication) indicates, that the data
communication failed.
"Reset"
Indicates that the DUT is in reset state.
In the CPRI RE test mode, the LED shows that a reset was performed,
and in CPRI REC test mode, the LED indicates a reset request.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​REMote:​LOF?​ on page 313
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​REMote:​LOS?​ on page 313
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​REMote:​RAI?​ on page 314
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​REMote:​RESet?​ on page 314
[:​SOURce<hw>]:​EBOX:​CPRI:​L1:​RX:​REMote:​SAP?​ on page 314
7.2.8.3 Events
In CPRI RE test mode the R&S EX-IQ-BOX acts as a CPRI REC (master). As defined in
the CPRI standard specification, the CPRI REC provides the generation of Layer 1 mes-
sages. In this section, you can simulate some events. Use this function to see how the
DUT responds to these events.
SDI
Activate the SDI (Service Access Point Defect Indication) defect indicator. This function
intentionally provokes an SDI event, in order to examine whether the DUT evaluates it.
In realtime applications, the function detects whether an SAP (Service Access Point) is
defective or is not working properly.
Note: This function applies to CPRI RE test mode. In this mode, the R&S EX-IQ-BOX
acts as a CPRI REC (master). As defined in the CPRI standard specification, the CPRI
REC provides the generation of Layer 1 messages. In this section, you can simulate some
events. Use this function to see how the DUT responds to these events.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​TX:​SDI​ on page 329
CPRI
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
convert pdf to url; add pdf to website html
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
NET library to batch convert PDF files to jpg image files. Turn multiple pages PDF into single jpg files respectively online.
convert pdf to html5; convert pdf into html email
Protocol Settings
R&S®EX-IQ-BOX
170
User Manual 1409.5570.32 ─ 05
RE Reset
Set or clear the bit on the downlink connection which requests the RE to reset.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​TX:​REReset​ on page 328
7.2.9 Downlink and Uplink
The Downlink and the Uplink tabs contain the settings for the CPRI basic frame. Down-
link and uplink parameters are similar; they both define the signals I/Q data and its dis-
tribution inside the CPRI basic frame container (AxC allocation).
The CPRI basic frame contains 16 words. The first word, the control word, contains con-
trol information, like synchronization, timing, slow or fast C&M, or vendor specific data.
The remaining words carry the I/Q data.
Terms used in the description and familiar synonyms
UL (Uplink): The UL defines the direction from a mobile device to a base station. A
synonym to UL is RL (Reverse Link).
DL (Downlink): The DL defines the direction from the base station to the mobile device.
A synonym to DL is FL (Forward Link).
Depending on the CPRI test mode, the R&S EX-IQ-BOX works either as a transmitter
(Tx) or receiver (Rx), as shown in the following diagrams.
● In CPRI RE test mode, the R&S EX-IQ-BOX works in the DL (downlink) as a trans-
mitter (Tx) and in the UL (uplink) as a receiver (Rx).
DUT
CPRI RE
EX-IQ-BOX
EXBOX
B85
Downlink
Uplink
RX
TX
Fig. 7-65: CPRI RE test - schematic representation
● In CPRI REC test mode, the R&S EX-IQ-BOX works in the DL as a receiver (Rx) and
in the UL as a transmitter (Tx).
DUT
CPRI REC
EX-IQ-BOX
EXBOX
B85
Downlink
Uplink
RX
TX
Fig. 7-66: CPRI REC test - schematic representation
CPRI
Protocol Settings
R&S®EX-IQ-BOX
171
User Manual 1409.5570.32 ─ 05
The settings dialogs for the transmitter (Tx) and the receiver (Rx) are identical in both
CPRI test modes (RE / REC).
Accordingly, the DL (downlink) dialog of CPRI RE and the UL (uplink) of CPRI REC are
similar, and vice versa, the UL dialog of the CPRI RE test is identical to the DL dialog of
CPRI REC.
The following description comprises the parameters of both dialogs, the UL and the DL,
since they use the same parameters. Specific settings that relate to a particular link
direction, are separately expressed.
Fig. 7-67: CPRI downlink dialog
CPRI
Protocol Settings
R&S®EX-IQ-BOX
172
User Manual 1409.5570.32 ─ 05
Fig. 7-68: CPRI uplink dialog
7.2.9.1 Signal Definition
Section "Signal Definition" contains all information which is important to define the I/Q
signals to be transmitted, or received via the CPRI link. On the left the table lists all defined
signals, and on the right of it input and display fields show the respective settings of the
selected signal. Signals are added, copied or removed by means of buttons and a groups
table indicates the AxCs assigned to a group.
The active AxCs are shown on the top right of this tab graphically. You find the description
to this graphic under ​chapter 7.2.9.2, "AxC Container Definition", on page 186.
Signal Table
The table lists the all defined signals. Select a signal in the table, to view the current
settings of this signal.
The list can take up at most 24 signals, according to the maximum number of AxCs, since
a signal needs at least one AxC.
CPRI
Protocol Settings
R&S®EX-IQ-BOX
173
User Manual 1409.5570.32 ─ 05
Note: By default, R&S DigIConf names the signals signal_ with an attached
<index> number. The index number represents the position in the list. In order to assign
a user defined name, enter the name in the field "Signal Name" on the right.
Append
Add a new signal to the list. R&S DigIConf attaches a signal with default parameter val-
ues, a predetermined name and a name index following the last list entry.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal:​APPend​ on page 337
Copy + Append
Create a copy of a selected signal. This function copies the parameter values and assigns
the same name with suffix for distinction. The new signal is added at the end of the list.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal<ch>:​COPY​ on page 342
Delete
Remove the currently selected signal from the list. The function removes the correspond-
ing AxCs from the list of used AxCs.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal<ch>:​DELete​ on page 343
Signal State
Activate a selected signal.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal<ch>:​STATe​ on page 352
Signal Name
Enter or change the signal name.
By default, R&S DigIConf assigns the name signal_ with an attached <index> num-
ber. The index number represents the position in the list.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal<ch>:​NAME​ on page 346
Physical Source
Select the signal source for signal transmission to the DUT. The signal comes either from
an R&S instrument via the digital interface of the R&S EX-IQ-BOX, or the signal is gen-
erated internally or by means of the waveform memory in the R&S EX-IQ-BOX.
The R&S EX-IQ-BOX converts the I/Q format of the signal into the CPRI protocol format.
Embedded with additional control information, the link transfers the data to the DUT.
Note: You can select the signal source if the R&S EX-IQ-BOX works as transmitter, that
means if it sends a signal to the DUT. That is, if you work in the RE Test Downlink or
the REC Test Uplink mode. Hence, the parameter is available only in the corresponding
DL or UL tab.
CPRI
Protocol Settings
R&S®EX-IQ-BOX
174
User Manual 1409.5570.32 ─ 05
However, when the R&S EX-IQ-BOX receives a signal, "Signal Output" is available in the
corresponding tabs instead of "Physical Source". See also ​"Signal Output"
on page 174.
"Sync Pattern" " Use the internal pattern generator as signal source.
"DIG IQ IN 1"
An R&S instrument applies a digital baseband signal at DIG IQ IN 1
connector of the R&S EX-IQ-BOX.
The green IN/OUT LED of this interface indicates, that it operates in
input mode.
"ARB 1...4"
Selects one of the waveform memories with a loaded I/Q signal.
Note:
● This feature requires, that the R&S EX-IQ-BOX is equipped with the
appropriate waveform memory option.
A conflict arises, if no signal is loaded in the memory, or is not acti-
vated. The LED next to "Wave File" and "Sample Rate" tuns red.
The Multi Waveform option supports simultaneous playback of up to
four signals. For information on the available options refer to ​chap-
ter 3.2.2.3, "Waveform Memory, Multi Waveform Playback and Record-
ing Memory ", on page 23.
"Static Frame" " Enables you to fill the complete CPRI frame with a static pattern for
debugging purposes. This pattern is transmitted as it is, without scaling,
rounding or interleaving.
"PRBS"
Generates a PRBS pattern.
If you additionally set ​Signal Output to "BER Test", you can perform a
bit error test with this pattern, to evaluate the signal transmission in the
Rx path.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX:​SIGNal<ch>:​SOURce​ on page 332
Signal Output
Select an output interface, to transmit the received baseband signal from the DUT to an
R&S instrument and/or to the built-in I/Q recorder.
The R&S EX-IQ-BOX extracts the I/Q baseband signal of the CPRI protocol, and forwards
it to an R&S instrument. Simultaneously, you can also record the signal with the I/Q
recorder, see ​chapter 7.2.14, "Recorder", on page 207.
Note: You can select "Signal Output" if the R&S EX-IQ-BOX works as receiver, that
means if it receives a signal from the DUT. That is, if you work in the RE Test Uplink or
the REC Test Downlink mode. Hence, the parameter is available only in the corre-
sponding DL or UL tab.
However, when the R&S EX-IQ-BOX transmits a signal, "Physical Source" is available
in the corresponding tabs instead of "Signal Output". See also ​"Physical Source"
on page 173.
"DIG IQ OUT <n> / Recorder"
Selects the digital output interface DIG IQ IN 2 of the R&S EX-IQ-BOX
to send the signal to an R&S instrument.
The yellow IN/OUT LED of this interface indicates, that it operates in
input mode.
CPRI
Documents you may be interested
Documents you may be interested