Protocol Settings
R&S®EX-IQ-BOX
185
User Manual 1409.5570.32 ─ 05
"Pattern"
Shows the binary data pattern of an AxC in hexadecimal format. By
default, all data pattern is set to zero. Click a field or press the
ENTER key to insert the required pattern. You can basically set up to
36 bits, but the currently possible number depends on the signal length
that is specified in ​Pattern Length.
Note: Pattern is displayed when you are working with "Sync Pattern"
signals.
Example: 
The following example explains the need of the CPRI group definition:
Let us assume we want to transmit an I/Q signal over the CPRI link with
a sampling rate of 5.76 MS/s. The CPRI basic frame rate amounts the
defined 3.84 MHz.
This means, if we assign one AxC per basic frame, we have the sample
rate of 3.84 MS/s. If we assign two AxCs, we get a sample rate of
7.68 MS/s.
Note: An AxC is a container for one I/Q sample.
But, for the required sample rate of 5.76 MS/s, we would need 1.5 AxCs
per basic frame.
How can we reach that?
We allocate 2 AxCs in the AxC container definition which corre-
sponds to: ceiling = 1.5. For example, we use "AxC0" and "AxC1".
In the "Number of Groups" entry field, we define two groups.
● Then, in the groups table, we define:
– G#0: Repetition = 3, State = On
– G#1: Repetition = 1, State = Off
With these settings, we transmit 2 samples (G#0) for one basic frame,
and only 1 sample (G#1) for the following.
Now we have achieved the required average sample rate of 5.76 MS/
s.
Tip: By changing the repetition in combination with the AxC states, you
can achieve almost any sample rate.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SOURce<ch>:​GROup<user0>:​REPetition​
on page 345
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SOURce<ch>:​GROup<user0>:​STATe​
on page 345
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​GROup<user0>:​PATTern​ on page 344
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SOURce:​GROup:​CALC​ on page 344
CPRI
Convert pdf to web page - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
change pdf to html format; convert pdf to html with
Convert pdf to web page - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
convert pdf to html format; convert pdf to html email
Protocol Settings
R&S®EX-IQ-BOX
186
User Manual 1409.5570.32 ─ 05
7.2.9.2 AxC Container Definition
The AxC Container Definition section graphically displays the CPRI basic frame and
indicates the I/Q and AxC data rates. The table in the lower part contains the used AxCs
with their assigned signals, and basic signal parameters such as word address, bit
address and word size. LEDs in the last column indicate emerging conflicts between
AxCs.
CPRI Basic Frame Graph
The basic frame graph indicates the 16 words of a CPRI basic frame in a control matrix.
First the control word is shown, then the remaining words follow, carrying the I/Q data.
The data words are structured in AxCs (antenna carriers). A signal needs one or more
AxCs for carrying the I/Q data, depending on the sample rate.
The word length depends on the CPRI line bit rate parameter. This parameter defines
the number of bits transferred per second over the CPRI communication link, including
control and I/Q data.
The following table shows the word length related to the bit rate.
Table 7-10: CPRI Line bit rate vs. Word length
Line bit rate [Mbit/s]
Word length [bits]
[Bytes]
1x (614.4)
8
1
2x (1228.8)
16
2
4x (2457.6)
32
4
5x (3072.0)
40
5
CPRI
C# PDF Convert to SVG SDK: Convert PDF to SVG files in C#.net, ASP
Instantly convert all PDF document pages to SVG image files in C#.NET class Perform high-fidelity PDF to SVG conversion in both ASP.NET web and WinForms
convert pdf to html5 open source; embed pdf into web page
C# PDF: How to Create PDF Document Viewer in C#.NET with
image and outline preview for quick PDF document page navigation; Support rendering web viewer PDF document to images or svg file; Free to convert viewing PDF
pdf to html; convert pdf to html code c#
Protocol Settings
R&S®EX-IQ-BOX
187
User Manual 1409.5570.32 ─ 05
Line bit rate [Mbit/s]
Word length [bits]
[Bytes]
8x(4915.2)
64
8
10x (6414.0)
80
10
16x (9830.4)
128
16
Note: When a word consists of more than 1 byte, the graph indicates these bytes and
separates them with a hyphen.
The first word contains control information while the following words carry the AxCs, that
means the I/Q data.
R&S DigIConf shows the signals in different colors, as well as the related AxCs. Active
signals are strongly colored, while the inactive signals are shown in pale colors. If the
signals in the graph overlap, the active signals are always in the foreground. Below the
graph, a legend explains the signals and their assigned colors.
Available Data Rate (I/Q)
Displays the available data rate of the I/Q data, calculated with the formula:
 
 
 
 
MHz
bit
Length
Word
MHz
bit
Length
Word
Count
Word
Data
s
Mbit
Rate
Data
avaliable
3.84
15
3.84
/
Note: The word length depends on the line bit rate, as listed in ​"CPRI Basic Frame
Graph" on page 186.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​DRATe:​AVAilable?​ on page 337
Assigned Data Rate (AxC)
Displays the assigned I/Q data rate of all active signals. This parameter depends on the
size of each assigned AxC and is calculated with the formula:
 
MHz
size
AxC
s
Mbit
Rate
Data
axc
assigned
3.84
_
/
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​DRATe:​ASSigned?​ on page 336
I/Q Data Interleaving
Activates I/Q data interleaving.
The following graphs show the sample arrangement and transmission order for uplink
and downlink:
I/Q data interleaved
Fig. 7-70: Interleaved I/Q data transmission within a CPRI link
I/Q data non interleaved.
CPRI
C# HTML5 Viewer: Load, View, Convert, Annotate and Edit PDF
When viewing PDF document on web viewer, users can C# users can perform various PDF conversion actions, such as convert PDF to Microsoft Office Word
convert pdf link to html; how to change pdf to html format
C#: How to Add HTML5 Document Viewer Control to Your Web Page
the necessary resources for creating web document viewer addCommand(new RECommand("convert")); _tabFile.addCommand new UserCommand("pdf"); _userCmdDemoPdf.
convert pdf to web; convert pdf to html open source
Protocol Settings
R&S®EX-IQ-BOX
188
User Manual 1409.5570.32 ─ 05
Fig. 7-71: Non Interleaved I/Q data transmission within a CPRI link
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​INTerleaving​ on page 337
AxC Table
Shows the settings of the assigned AxCs. An AxC is defined by the position inside the
CPRI basic frame and its length.
"Source"
Indicates the signal the AxC is assigned to.
"Word Address"
The position of the AxC within the CPRI basic frame is defined by word
address and bit address. The word address specifies, with which word
the AxC begins, while the bit address specifies the bit index inside the
word.
"Bit Address"
Specifies the starting bit inside the word.
"Size /bits"
Displays the size of the AxC in bits. The size depends on the selected
signal source. With the exception of signals from the signal source Sync
Pattern, the size is calculated using the following formula:
 
2
Re
/
_
signal
axc
solution
I Q
bit
size
AxC
For Sync Pattern signals, calculate the source with the formula:
 
signal
axc
Length
Pattern
bit
size
AxC
_
"Conflict"
A conflict arises, when AxCs overlap. A red LED indicates the overlap-
ping with a previous AxC.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​AXC<ch0>:​SOURce?​ on page 335
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​AXC<ch0>:​WADDress​ on page 336
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​AXC<ch0>:​BADDress​ on page 334
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​AXC<ch0>:​SIZE?​ on page 335
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​AXC<ch0>:​CONFlict?​ on page 334
Start Condition
Defines the start condition for the scheduler, for data transmission and analysis.
Note:
To define a fractional scheduling scheme, consider the following:
align the start of the scheduling scheme either to a Hyper Frame, or a Node B Frame.
make sure that the total number of repetitions, for example "1 On"; "3 Off" is an integer
multiple of basic frames inside a Hyper Frame (256) or Node B Frame (38400).
Otherwise
use a Sync Pattern in both, the Tx and Rx path.
CPRI
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Support to create new page to PDF document in both web server-side application and Windows Forms. Ability to add PDF page number in preview.
pdf to html converter; convert pdf to html online
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
and quickly convert a large-size multi-page PDF document to a group of high-quality separate JPEG image files within .NET projects, including ASP.NET web and
convert pdf to url online; converting pdf to html code
Protocol Settings
R&S®EX-IQ-BOX
189
User Manual 1409.5570.32 ─ 05
"Software"
Starts scheduling and data transmission/reception after a software trig-
ger.
"Ext. Trigger 1...3"
Starts the scheduling and data transmission/reception with an external
trigger signal. To supply the trigger signal use one of the GPIOs and
configure it accordingly in the "Hardware" tab.
"Basic Frame" " Starts scheduling and data transmission/reception with the next Basic
Frame. This corresponds to a free running trigger.
"Hyper Frame" " Aligns scheduling and data transmission/reception to the next Hyper
Frame.
"Node B Frame"
Aligns scheduling and data transmission/reception to the next Node B
Frame.
"Sync Pattern" " Aligns the timing and data transmission/reception in the Rx path accord-
ing to a received sync pattern defined within a specified AxC. This trig-
ger mode requires that you have assigned "Sync Pattern" to one of the
signals.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​TRIGger:​SOURce​ on page 332
Arm
Stops the data transmission, the scheduler and analysis. A subsequent trigger event
restarts the activities.
To select the trigger signal source, see ​Start Condition
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​APPLy​ on page 333
Run
Restarts data transmission, the scheduler and analysis manually.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​TRIGger:​ARM​ on page 332
Apply Setup
Assign the settings in order to become effective.
If you have modified settings, and not yet confirmed, the red 
arrow next to the "Apply
Setup" button prompts you to confirm your settings.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​WARNing?​ on page 352
[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​APPLy​ on page 333
Example to CPRI Groups Concept
Note: Since the CPRI protocol is based on the standards of 3G and LTE, the CPRI basic
frame length uses the UTRA FDD Chip period, 1/3.84 MHz, that means the resulting data
rate amounts 3.84 MHz.
CPRI
XDoc.HTML5 Viewer for .NET, Zero Footprint AJAX Document Image
View, Convert, Edit, Sign Documents and Images. Wide range of web browsers support including IE9+ powerful & profession imaging controls, PDF document, image to
add pdf to website; converting pdf to html
DocImage SDK for .NET: Web Document Image Viewer Online Demo
Document Viewer Demo to View, Annotate, Convert and Print upload a file to display in web viewer Suppported files are Word, Excel, PowerPoint, PDF, Tiff, Dicom
converter pdf to html; convert pdf into html code
Protocol Settings
R&S®EX-IQ-BOX
190
User Manual 1409.5570.32 ─ 05
Therefore, variations in the data rate appear with all signals whose data rate do not fit in
this 3.84 MHz pattern. The reason is that for these signals, the total sampling rate per
AxC group is not an integer multiple of the CPRI basic frame rate.
CPRI has developed a special method for the adjustment. By adjusting the grouping, the
repetitions and variable allocations of the AxCs, each signal can be individually custom-
ized to this pattern. In addition, CPRI adds stuffing samples, for example, vendor specific
bits, in order to adjust the data rate to an integer multiple of the CPRI frame rate.
Example: 
By means of a 10 MHz WiMAX signal, with an oversampling factor of 1 and an I/Q res-
olution of 16 Bit, the following settings present a possible solution.
In this example, the WiMAX data rate is 11.2 MHz and requires 3 AxCs for its data. Since
3.84 MHz does not fit into 11.2 MHz, change the following parameters:
● Increase the number of groups to 2.
Enter 35 repetitions for Group "G #0", and 1 for "G #1".
Allocate all the AxCs of the first group consecutively, and from the second group only
AxC0 and AxC1.
CPRI
C# Image: Quick to Navigate Document in .NET Web Viewer
API can be called from any document page object for navigate to the target part of web viewer document well-formed documents, like Word and PDF, will contain
convert pdf to html online for; how to add pdf to website
Protocol Settings
R&S®EX-IQ-BOX
191
User Manual 1409.5570.32 ─ 05
The graph in the AxC Container Definition shows the distribution of the data in the CPRI
frame slots.
Argument
Let us prove that using the formula:
 
 
OffTime
OnTime
OnTime
Cs
AssignedAx
solution
I/QRe
MHz
.
/s
Mbit
Rate
Data
assigned
2
384
 
 
/s
Mbit
.
bit
MHz
.
/s
Mbit
DataRate
assigned
4
358
36
35
3
2 16
384
 
 
7.2.9.3 Low Level BER Test
In section Low Level BER Test, you can check the data transmission in the Rx path of
the CPRI link, provided "Signal Output > BER Test" is set. The Bit-Error-Rate function
evaluates the bit error ratio with a defined data sequence.
Therefore, the PRBS AxCs of the uplink and downlink must be identical regarding "Pat-
tern Length" and position, defined with "Word Addr." and "Bit Addr.".
► To process the "Low Level BER" test, select "Tx Source > PRBS" , and "Rx Signal
Output > BER Test".
Depending on the Test mode, ​"Physical Source" on page 173 "(Tx)", and ​"Signal
Output" on page 174 "(Rx)" are given in the corresponding downlink and uplink tab.
The position and the length of the downlink and uplink AxCs must be identical and the
CPRI line must be looped back, e.g. in the DUT.
CPRI
Protocol Settings
R&S®EX-IQ-BOX
192
User Manual 1409.5570.32 ─ 05
Example to Low Level BER Test using CPRI RE test mode
DUT
PRBS
UL
DL
BER 
result
Fig. 7-72: Low Level BER Test
For testing a signal execute the following steps.
1. Define a signal in the downlink tab: Select "Physical Source > PRBS" in the downlink
tab and configure the AxC parameters regarding "Pattern Length" and position by
means of adjusting the "Word and Bit address" inside the CPRI frame.
2. Define a signal in the uplink tab: Select "Signal Output > BER Test"", and set the
same values for AxC "Pattern length" and position as in the downlink tab
Note: For testing the function itself, the signals in the downlink and uplink tab must
be identical.
3. Apply the Tx and Rx settings.
4. Set the connected DUT to CPRI loopback mode.
Note: The integrated loop-back function in the CPRI breakout board provides sending
and receiving signals, without plugging in an SFP module.
5. Reset the PRBS Test, if necessary.
Note: It is recommended that you reset the "PRBS Test", after you have changed the
settings at the DUT, or unplugged external cables.
6. The function extracts received data from the uplink signal and compares it with the
expected PRBS data. The total number of received words and the calculated BER
are displayed.
The bit error rate test function embeds a known PRBS sequence in the CPRI protocol
and synchronizes the analysis on the receiver side with the received (looped) signal.
It synchronizes the data which are returned internally, compares these data with the
data being sent, and counts the bit errors. The ratio of the number of error bits to the
total number of bits is the BER-result.
Use this function to see whether the link is working properly. You can monitor the test
result continuously in the "Test & Diagnostics" tab.
Expected Results:
When you send a signal and the settings for the received signal are identical, the error
must be "0".
CPRI
Protocol Settings
R&S®EX-IQ-BOX
193
User Manual 1409.5570.32 ─ 05
Simulate an error:
1. Configure different AxC positions in uplink and downlink while in loopback mode.
2. In the uplink tab, you can see that the error rate is increasing steadily.
This shows that the box detects the shift between the signals, and can thus detect
the errors in real-world signals from the DUT and vice versa.
Rx Received Bits
Indicates the total number of received words. Low Level BER Test consecutively counts
the number of received words in order to compare them with the sent data and to deter-
mine the error rate.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​BER:​RX:​WORDs?​ on page 325
Rx BER
Displays the number of bit errors. This function consecutively counts the number of dis-
crepancies that occur during the test. The BER result is the ratio, which is calculated by
dividing the number of error bits by the total number of bits.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​TEST:​BER:​RX:​RATE?​ on page 324
Reset
Restarts the PRBS test.
Performing a reset is recommended after changes of CPRI link parameters or external
connections, to start from a defined initial state.
Remote command: 
[:​SOURce<hw>]:​EBOX:​CPRI:​PRBS:​RST​ on page 325
7.2.10 Control & Management
The Control & Management (C&M) tab comprises all settings related to the process of
exchanging control information between RE (Radio Equipment) and REC (Radio Equip-
ment Control) in base station systems. CPRI supports two different protocols for C&M
data, the slower variation HDLC (High-Level Data Link Control) and the fast Ethernet.
7.2.10.1 Slow C&M (HDLC)
The HDLC Settings section comprises the necessary parameters for activating HDLC
control and management data protocol.
In chapter ​chapter 4.5, "Connecting the R&S EX-IQ-BOX", on page 42, you find infor-
mation on how to connect the interface. For more information on the hardware, see the
data sheet of the R&S EX-IQ-BOX, option R&S EXBOX-B85 (CPRI breakout board).
CPRI
Protocol Settings
R&S®EX-IQ-BOX
194
User Manual 1409.5570.32 ─ 05
Fig. 7-73: CPRI Control & Management dialog - Slow C&M (HDLC)
R&S DigIConf provides two methods for transmitting or receiving Slow C&M Data:
1. Using the internal Terminal, you can enter text commands. With EXECUTE, the
CPRI breakout board either encodes the plain text commands in HDLC format or
transmits the raw data over the CPRI link. Then, it transmits the data over the CPRI
link.
2. Using the RS232 interface, the CPRI breakout board expects already HDLC encoded
data on the RS-232-C input. Then, it transmits the encoded data in direct mode to
the DUT. The internal encoding and decoding are deactivated. This method works
full duplex, that means encoded HDLC frames are received from the DUT and output
at the RS-232-C port. In the other direction, encoded HDLC frames are entered on
the RS-232-C and then transmitted via the slow C&M CPRI link to the DUT.
You can use this method in both test modes, the CPRI RE and the CPRI REC test mode.
CPRI
Documents you may be interested
Documents you may be interested