embed pdf in mvc view : Convert pdf to html online for application control utility azure html web page visual studio EX-IQ-BOXK04_OperatingManual_en_0536-part1280

Remote Control Commands
R&S®EX-IQ-BOX
345
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SOURce<ch>:GROup<user0>:REPetition
<Repetition>
Selects the AxC group and specifies the number of repetitions of the signal, that menas
how many CPRI basic frames follow the current group setting.
The numeric suffix GROUP<user0> distinguishes the selected group. Up to 4 groups can
be specified. These are "G #0" to "G #3".
Note: AxC status and AxC pattern depend on the used signal sources. Status refers to
externally used sources and pattern indicates the coding of the AxCs with internal signal
source.
Parameters:
<Repetition>
integer
Range: 
 to  20000
Increment: 1
*RST: 
1
Example: 
EBOX:CPRI:TX:SOUR:GRO:REP 3
repeats the signal of Group1 3 times.
Manual operation: See "Groups Table" on page 183
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SOURce<ch>:GROup<user0>:STATe <state>
Activates the respective AxC. By default, all AxCs are activated.
Parameters:
<state>
0 | 1 | OFF | ON
*RST: 
ON
Example: 
EBOX:CPRI:TX:SOUR:GRO:STAT ON
activates AxC1 in the first group of the AxC allocation table.
Manual operation: See "Groups Table" on page 183
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:IQResolution <Iqresolution>
Sets the I/Q resolution in bits. The resolution is valid for both, the I and the Q values. I.e,
if you set the resolution to 16 bits, the sample rate is 32 bits wide, composed of 16-bit I
and 16-bit Q.
Parameters:
<Iqresolution>
float
Range: 
 to  18
Increment: 1
*RST: 
16
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:IQR 16
sets 16 bits I/Q resolution.
Manual operation: See "I/Q Resolution" on page 179
CPRI Remote Control Commands
Convert pdf to html online for - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
online pdf to html converter; how to convert pdf into html
Convert pdf to html online for - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
pdf to html converter; convert pdf to html file
Remote Control Commands
R&S®EX-IQ-BOX
346
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:NAME <Name>
This command enters or changes the signal name.
Parameters:
<Name>
string
Example: 
SOUR1:EBOX:CPRI:TX:SIGN4:NAME "sig_3gpp"
assign the signal name sig_3gpp to the fourth signal of the list in
transmitter mode.
Manual operation: See "Signal Name" on page 173
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:NFORmat <Nformat>
Selects a numeric representation for data transmission.
Allowed number range for word size n Bit:
-2n-1 ≤ n ≤ +2n+1
Table 9-4: User defined > Numeric format coding
 2´s Complement
Binary Offset
-8
1
0
0
0
0
0
0
0
-7  1
0
0
1
0
0
0
1
-6  1
0
1
0
0
0
1
0
-5
1
0
1
1
0
0
1
1
-4  1
1
0
0
0
1
0
0
-3  1
1
0
1
0
1
0
1
-2
1
1
1
0
0
1
1
0
-1  1
1
1
1
0
1
1
1
 0
0
0
0
1
0
0
0
1
0
0
0
1
1
0
0
1
 0
0
1
0
1
0
1
0
 0
0
1
1
1
0
1
1
4
0
1
0
0
1
1
0
0
 0
1
0
1
1
1
0
1
 0
1
1
0
1
1
1
0
7
0
1
1
1
1
1
1
1
CPRI Remote Control Commands
Online Convert PDF to HTML5 files. Best free online PDF html
Online PDF to HTML5 Converter. Download Free Trial. Convert a PDF file to HTML. Just upload your file by clicking on the blue button
convert pdf to website html; pdf to html converters
VB.NET PDF - Convert PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
change pdf to html format; converter pdf to html
Remote Control Commands
R&S®EX-IQ-BOX
347
User Manual 1409.5570.32 ─ 05
I
1
Q
1
I
2
Q
2
I
0
Q
0
I
3
Q
3
I
4
Q
4
I
5
Q
5
I
6
Q
6
I
7
Q
7
I
8
Q
8
I
9
Q
9
Common
exponent
Q mantissa
I mantissa
Fig. 9-7: 2's complement 9E2
The I and Q samples of the 2's complement 9E2 are calculated with the formulas:
I sample 10 bits = 9 bits mantissa + 1 bit, i.e. bit_0 exponent
0
0
2
9
8
7
0
1
2
2
2
I
Q
i
i
i
I
I
I
 
Q sample 10 bits: 9 bits Q mantissa + 1 bit, i.e. bit_1 exponent
0
0
2
9
8
7
0
1
2
2
2
I
Q
i
i
i
Q
Q
Q
 
Parameters:
<Nformat>
COMPlement | C9E2 | BOFFset
COMPlement
Formats the signal in two's-complement.
The most significant bit has a value of -2n-1, the bits of lesser sig-
nificance follow as:
+2n-2...+20
C9E2
Formats the signal in two's-complement variant 9E2.
BOFFset
Formats the signal in binary offset.
Adds a binary offset of -2n-1 such that the final values are always
positive.
Example
Adds a binary offset of -2n-1 such that the final values are always
positive.
*RST: 
COMPlement
Example: 
SOUR1:EBOX:CPRI:TX:SIGN2:NFOR COMP
set the numeric format of the second signal to 2's complement 2.
Manual operation: See "Numeric format" on page 177
CPRI Remote Control Commands
C# HTML5 PDF Viewer SDK to convert and export PDF document to
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
convert pdf into html code; how to add pdf to website
VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
converting pdf to html code; convert pdf to html
Remote Control Commands
R&S®EX-IQ-BOX
348
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:OSAMpling <Osampling>
Determine the oversampling factor.
Note: Oversampling appliers to external signals, i.e. to digital standards or to user defined
signals. If the R&S EX-IQ-BOX is working with an internal signal, that is generated by a
pattern or a waveform file, the parameter is already considered and therefore not relevant.
Parameters:
<Osampling>
integer
Range: 
 to  4
Increment: 1
*RST: 
1
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:OSAM 2
sets oversampling factor 2.
Manual operation: See "Oversampling" on page 177
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:PLENgth <Plength>
Defines the length of the pattern used by the internal pattern generator.
Note: The parameter applies to the physical source PATTern.
Parameters:
<Plength>
float
Range: 
 to  40
Increment: 2
*RST: 
16
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:PLEN 4
sets the pattern length 4.
Manual operation: See "Pattern Length" on page 177
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:RMS?
Queries the rms level of the signal. The signal level is expressed in terms of an rms value.
It always refers to both signal components (SQR(I2+Q2)).
In order to get the RMS value correctly, the crest factor of the signal must be specified,
see ​[:​SOURce<hw>]:​EBOX:​CPRI:​TX|RX:​SIGNal<ch>:​CRESt​ on page 342.
The rms level is calculated with the formula:
RMS [dB] = Peak [dB] - Crest Factor [dB] + Gain [dB]
Note: The RMS level refers to external signals, i.e. to digital standards or to user defined
signals. If the R&S EX-IQ-BOX is working with an internal signal, that is generated by a
pattern or a waveform file, the parameter is already known must not be entered manually.
CPRI Remote Control Commands
VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.
Resize converted Tiff image using VB.NET. Convert PDF file to Tiff and jpeg in ASPX webpage online. Online source code for VB.NET class.
convert pdf form to web form; convert pdf to html open source
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
convert from pdf to html; embed pdf into html
Remote Control Commands
R&S®EX-IQ-BOX
349
User Manual 1409.5570.32 ─ 05
Return values: 
<Rms>
float
Range: 
-40  to  6
Increment: 0.01
*RST: 
0
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:RMS?
query the crest factor.
Response: -10 dbFS
Usage: 
Query only
Manual operation: See "RMS Level" on page 180
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:SRATe <Srate>
Queries the sample rate. If you process user defined signals, you can set the value.
Consider that the sampling rate of the R&S signal generator fits to the sampling rate of
R&S DigIConf, as well as to the sampling rate of the R&S signal analyzer.
The table shows the predefined sample rates of the available signals. The sample rate
of a digital standard varies corresponding to the frequency.
Table 9-5: Sample rate values, depending on the signal type
Standard
Frequency variant
Sample Rate
GSM/EDGE
270.8333 kHz
3GPP FDD
3.84 MHz
CDMA 2000
1.228 MHz
LTE
1.4 MHz
1.92 MHz
3.0 MHz
3.84 MHz
5.0 MHz
7.68 MHz
10.0 MHz
15.36 MHz
15.0 MHz
23.04 MHz
20.0 MHz
30.72 MHz
WiMAX
3.5 MHz
4.0 MHz
5.0 MHz
5.6 MHz
7.0 MHz
8.0 MHz
8.75 MHz
10.0 MHz
10.0 MHz
11.2 MHz
Sync Pattern
3.84 MHz
CPRI Remote Control Commands
VB.NET PDF- View PDF Online with VB.NET HTML5 PDF Viewer
RasterEdge. PRODUCTS: ONLINE DEMOS: Online HTML5 Document Viewer; Online XDoc.PDF Demo▶: Convert PDF to Word; Convert PDF to Tiff; Convert PDF to HTML; Convert
convert pdf to web page; convert pdf into html file
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
NET library to batch convert PDF files to jpg image files. Turn multiple pages PDF into single jpg files respectively online.
convert pdf to html email; convert pdf to html code c#
Remote Control Commands
R&S®EX-IQ-BOX
350
User Manual 1409.5570.32 ─ 05
Parameters:
<Srate>
float
Range: 
1000  to  100000000
*RST: 
3840000
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:SRATe?
query the sample rate of the first signal in transmitter mode.
Manual operation: See "Sample Rate" on page 176
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:STANdard <Standard>
This command selects a communication standard. R&S DigIConf provides the selection
of a standard signal with automatically assigned sample rate. Alternatively, select a signal
from a waveform file, the ARB function, or assign user-specific values.
R&S DigIConf supports all current standards and their variants. When selecting a stand-
ard signal, the program automatically sets the relevant parameters and values.
For example, a loaded digital standard automatically adjusts the needed AxCs, assigns
the sample rate, and sets up several other relevant parameters.
Note: The digital standard signals, or user defined signals refer to external signal input
or output, i.e. the physical signal sources DIG IQ IN or DIG IQ OUT.
CPRI Remote Control Commands
Remote Control Commands
R&S®EX-IQ-BOX
351
User Manual 1409.5570.32 ─ 05
Parameters:
<Standard>
USER | W3GPP | LTE_1M4 | LTE_3M | LTE_5M | LTE_10M |
LTE_15M | LTE_20M | WIMAX_3M5 | WIMAX_5M | WIMAX_7M |
WIMAX_8M75 | WIMAX_10M | CDMA2K | WIMAX_20M | GSM
USER
Specifies a user defined signal for transmission, define a signal
with arbitrary parameters.
W3GPP
Selects the parameters of the W-CDMA standard 3GPP FDD.
W-CDMA (Wideband Code Division Multiple Access) covers the
radio technology UMTS (Universal Mopbile Telecommunications
System). 3GPP (3rd Generation Partnership Project) is a collab-
oration between groups of telecommunication associations, which
define a globally applicable third generation mobile phone system
specification. 3GPP standardization comprises all GSM and W-
CDMA specifications.
LTE_1M4|LTE_3M|LTE_5M|LTE_10M|LTE_15M|LTE_20M
Selects an LTE (Long Term Evolution) signal. Based on UMTS,
LTE provides a wireless broadband internet system with voice and
other services built on top, e.g. authentication.
LTE bandwidths: 1.4 | 3.0 | 5.0 | 10.0 | 15.0 | 20.0 MHz
WIMAX_3M5|WIMAX_5M|WIMAX_7M|WIMAX_8M75|
WIMAX_10M|WIMAX_20M
Selects the digital standard IEEE 802.16 WiMAX (Worldwide Inter-
operability for Microwave Access). WiMAX provides wireless
transmission of data using a variety of transmission modes, as e.g.
point-to-multipoint links or mobile internet access.
WiMAX bandwidths: 3.5 | 5.0 | 7.0 | 8.75 | 10.0 | 20.0 MHz
CDMA2K
Selects a signal that follows the CDMA standard.
CDMA2000 (Code Division Multiple Access) uses a multiple
access scheme for digital radio, to send voice, data, and signaling
data (such as a dialed telephone number) between mobile phones
and cell sites.
GSM
Selects a signal that follows te GSM/EDGE standard.
GSM/EDGE (Global System for Mobile Communications/
Enhanced Data Rates for GSM Evolution) covers the 2nd gener-
ation mobile radio technology. Selecting this signal standard, the
sample rate is set to 270,833333 kSps. This sample rate does not
fit well into the CPRI basic frame rate. Therefore, the sampling rate
of GSM/EDGE is only achieved by using a rather complicated
group setup, the AxC settings over time.
*RST: 
W3GPP
Example: 
SOUR1:EBOX:CPRI:TX:SIGN:STAN LTE_20M
select an LTE signal with 20 MHz bandwidth.
Manual operation: See "Standard" on page 175
CPRI Remote Control Commands
Remote Control Commands
R&S®EX-IQ-BOX
352
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SIGNal<ch>:STATe <State>
The command activates a signal for transmission selected with <ch>.
Parameters:
<State>
OFF | ON
*RST: 
OFF
Example: 
SOUR1:EBOX:CPRI:RX:SIGN:STAT ON
activates the fist signal for transmission in reciever mode.
Manual operation: See "Signal State" on page 173
[:SOURce<hw>]:EBOX:CPRI:TX|RX:WARNing?
The command asks if settings have been changed, but not accepted.
Return values: 
<Warning>
0 | 1
*RST: 
0
Example: 
SOUR1:EBOX:CPRI:TX:WARN?
check if changed settings have been accepted.
Response: 1 if settings are not yet accepted, 0 if OK.
Usage: 
Query only
Manual operation: See "Apply Setup" on page 189
9.4.10 CPRI Vendor Data Subsystem
The VENDor:DATA command subsystem provides input of user-specific information via
remote control commands.
[:​SOURce<hw>]:​EBOX:​CPRI:​VENDor:​DATA<ch>​
.............................................................352
[:​SOURce<hw>]:​EBOX:​CPRI:​VENDor:​DIRection​
..............................................................353
[:​SOURce<hw>]:​EBOX:​CPRI:​VENDor:​STATe​
...................................................................353
[:​SOURce<hw>]:​EBOX:​CPRI:​VENDor:​WWIDth?​
...............................................................353
[:SOURce<hw>]:EBOX:CPRI:VENDor:DATA<ch> <Data>
Queries or determines vendor-specific data for transmission, depending on the trans-
mission mode.
Parameters:
<Data>
integer
The value range depends on the word width.
Range: 
"depends on other settings"  to  "depends on other
settings"
Example: 
SOUR1:EBOX:CPRI:VEND:DATA 16,#H2A
determine vendor-specific data for transmission.
CPRI Remote Control Commands
Remote Control Commands
R&S®EX-IQ-BOX
353
User Manual 1409.5570.32 ─ 05
Manual operation: See "Vendor Data Table" on page 203
[:SOURce<hw>]:EBOX:CPRI:VENDor:DIRection <Direction>
The command selects the data direction for vendor data exchange.
Parameters:
<Direction>
DOWN | UP
DOWN
CPRI RE test mode (TX): User data entered in the table is embed-
ded in the CPRI link for transmission to the DUT.
CPRI REC test mode (RX): Vendor data is extracted from the
CPRI link and displayed in the table.
UP
CPRI RE test mode (RX): Vendor data is extracted from the CPRI
link and displayed in the table.
CPRI REC test mode (TX): User data entered in the table is
embedded in the CPRI link for transmission to the DUT.
*RST: 
DOWN
Example: 
SOUR1:EBOX:CPRI:VEND:DIR DLIN
determine the direction for vendor data transmission.
Manual operation: See "Direction" on page 201
[:SOURce<hw>]:EBOX:CPRI:VENDor:STATe <State>
The command starts and stops vendor data exchange.
Parameters:
<State>
OFF | ON
*RST: 
OFF
Example: 
SOUR1:EBOX:CPRI:VEND:STAT ON
start vendor data exchange.
Manual operation: See "State" on page 201
[:SOURce<hw>]:EBOX:CPRI:VENDor:WWIDth?
The command queries the word width. The word width depends on the CPRI line bit rate.
The following table shows the word width related to the line bit rate
Table 9-6: Word width related to the line bit rate.
Line bit rate
Word width
[Mbit/s]
[bits]
2x (1228.8)
16
CPRI Remote Control Commands
Remote Control Commands
R&S®EX-IQ-BOX
354
User Manual 1409.5570.32 ─ 05
Line bit rate
Word width
4x (2457.6)
32
5x (3072.0)
40
Note: By determining the line bit rate, the DUT also defines the word width. See also ​
[:​SOURce<hw>]:​EBOX:​CPRI:​HW:​LBRate​ on page 305.
Return values: 
<Wwidth>
float
Range: 
 to  18
Increment: 1
*RST: 
16
Example: 
SOUR1:EBOX:CPRI:VEND:WWID?
query the word width.
Usage: 
Query only
Manual operation: See "Word Width" on page 202
CPRI Remote Control Commands
Documents you may be interested
Documents you may be interested