embed pdf in mvc view : Embed pdf into html software Library project winforms .net windows UWP EX-IQ-BOXK04_OperatingManual_en_055-part1286

Getting Started
R&S®EX-IQ-BOX
35
User Manual 1409.5570.32 ─ 05
Prerequisites
● Uninstall the old software version, as described in ​chapter 4.4.3, "Uninstalling",
on page 38.
● Close any running applications.
● Disconnect all R&S EX-IQ-BOXes and do not connect any during installation.
4.4.1 Installation
The setup file DigIConf_x.xx.xxx.exe for the installation of the R&S DigIConf is included
in the delivery of your R&S EX-IQ-BOX or can be downloaded from the R&S website:
http://www.rohde-schwarz.com/product/EX-IQ-Box.html
► Execute DigIConf_x.xx.xxx.exe
in the windows explorer and follow the installation instructions of the R&S DigIConf
setup wizard.
The version number x.xx.xxx in the filename represents the current version. Each
update has a new release number.
During installation the program creates various subdirectories needed by the application.
Additionally, the installation wizard checks the status of the registry entry "DisableCAD"
in order to exclude logon conflicts during later operation. The wizard prompts you to
modify the DisableCAD status accordingly, in order to fix these conflicts.
Fig. 4-4: R&S
DigIConf Installation > Modify DisableCAD
● "Yes"
Accept modification.
The installation wizard sets DisableCAD=0 in the registry.
[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion
\policies\system]"DisableCAD"=dword:00000000
A connected R&S EX-IQ-BOX does not cause any conflicts at startup and logon.
● "No"
Reject modification.
The parameter DisableCAD remains 1 and you must disconnect the R&S EX-IQ-
BOX before every login and connect it afterwards again.
Backgound: Depending on this registry entry, a connected R&S EX-IQ-BOX may cause
an infinite loop at the Windows logon prompt. It occurs during a logon because Windows
interprets the internal SmartCard of the R&S EX-IQ-BOX as a medium for login. You find
more details also in ​chapter 4.4.4, "Known Restrictions on SmartCard Related Issues",
on page 39.
Installing R&S DigIConf
Embed pdf into html - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
convert pdf to html email; add pdf to website html
Embed pdf into html - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
how to convert pdf to html email; convert pdf into html online
Getting Started
R&S®EX-IQ-BOX
36
User Manual 1409.5570.32 ─ 05
It is recommended that you accept modification.
However, it is also possible, to modify the status later on. The installation wizard prepares
the respective entries for a later modification.
In the last installation window the setup wizard provides a shortcut to the desktop and
you can run R&S DigIConf.
4.4.2 Starting
R&S DigIConf can either be started via:
● the menu item "Start > Programs > R&S DigIConf > DigIConf_x.xx.xxx",
● by starting DigIConf.exe in the MS®Windows explorer, located in the prgram files
directory, %Program Files%\Rohde-Schwarz\DigIConf
or via
the "application icon" on the desktop.
Startup takes several seconds. At runtime a startup window is indicated until the software
is ready for operation. After startup, the R&S DigIConf main application window is dis-
played.
Installing R&S DigIConf
C# TIFF: How to Embed, Remove, Add and Update TIFF Color Profile
On the whole, our SDK supports the following manipulations. Empower C# programmers to embed, remove, add and update ICCProfile. Support
adding pdf to html; embed pdf to website
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Embed PDF to image converter in viewer. Quick evaluation source codes for VB.NET class. Sometimes, to convert PDF document into BMP, GIF, JPEG and PNG
online pdf to html converter; convert pdf to html link
Getting Started
R&S®EX-IQ-BOX
37
User Manual 1409.5570.32 ─ 05
Fig. 4-5: R&S
DigIConf main application window
The main application window shows the current configuration and the signal flow in form
of a block diagram.
Depending on the test configuration different elements are indicated. For example, if the
R&S EX-IQ-BOX is connected with an R&S instrument, R&S DigIConf shows a separate
function block with information about the connected instrument. Input/Output symbols in
the block diagram show the currently used inputs and outputs and the lines indicate the
signal flow.
The following pictures show an example of how R&S DigIConf adjusts the display accord-
ing to the test configuration. If several boxes are connected, the respective test configu-
ration is indicated for every R&S EX-IQ-BOX.
Fig. 4-6: R&S
DigIConf display of the R&S
EX-IQ-BOX connected to an R&S AMU200A
Fig. 4-7: R&S
DigIConf display of the R&S
EX-IQ-BOX connected to an R&S FSQ-26
Installing R&S DigIConf
C# Raster - Image Save Options in C#.NET
NET Read: PDF Image Extract; VB.NET Write: Insert text into PDF; VB.NET How-to, VB.NET PDF, VB.NET Word, VB a zone bit of whether it's need to embed Color profile
pdf to web converter; conversion pdf to html
C# TIFF: How to Insert & Burn Picture/Image into TIFF Document
Entire C# Code to Embed and Burn Image to TIFF GetPage(0); // load an PNG logo into REImage REImage powerful & profession imaging controls, PDF document, tiff
convert from pdf to html; convert pdf to web pages
Getting Started
R&S®EX-IQ-BOX
38
User Manual 1409.5570.32 ─ 05
Fig. 4-8: R&S
DigIConf display of the R&S
EX-IQ-BOX operating in bidirectional mode
For a detailed description of the application window and its elements refer to the operating
manual, ​chapter 6.1, "R&S DigIConf Configuration Software", on page 53.
4.4.3 Uninstalling
Uninstall the software with the aid of R&S DigIConf uninstaller,
1. "Start > Programs > R&S DigIConf > Uninstall"
or the PC's control panel,
2. "Start > Settings > Control Panel" in the Windows task bar and open the "Add or
Remove Programs" dialog. Uninstall the program with "Remove".
The uninstall routine identifies all currently installed R&S DigIConf components,
including the relevant files, such as files with user-specific settings.
Before uninstalling, the program asks whether you want to delete the settings direc-
tory as well.
3. Confirm or reject, and start uninstalling.
Installing R&S DigIConf
VB.NET TIFF: Rotate TIFF Page by Using RaterEdge .NET TIFF
formats are: JPEG, PNG, GIF, BMP, PDF, Word (Docx Visual Basic .NET class, and then embed "RasterEdge.Imaging splitting huge target TIFF file into multiple and
convert pdf form to web form; how to convert pdf to html email
VB.NET Image: How to Draw and Cutomize Text Annotation on Image
NET text annotation add-on tutorial can be divided into a few on document files in VB.NET, including PDF, TIFF & license and at last you can embed the required
pdf to html converters; convert pdf to webpage
Getting Started
R&S®EX-IQ-BOX
39
User Manual 1409.5570.32 ─ 05
The uninstaller removes all currently installed R&S DigIConf software items.
After completion the uninstall process is confirmed and can be finished with OK.
If you have decided to keep the preference files, the respective directories of DigIConf
remain.
4.4.4 Known Restrictions on SmartCard Related Issues
If a R&S EX-IQ-BOX is connected while the computer is locked, login can be performed
without any conflicts coming up. But if a R&S EX-IQ-BOX is already connected and you
want to log in, the following "Logon Message" appears:
Installing R&S DigIConf
VB.NET Image: VB.NET Code to Add Rubber Stamp Annotation to Image
Suitable for VB.NET PDF, Word & TIFF document managing & editing project. VB Can be implemented into both Windows and web VB.NET applications; Support single or
convert pdf to html open source; how to convert pdf to html
C# PDF url edit Library: insert, remove PDF links in C#.net, ASP.
and active html links in .NET WinForms. Able to insert and delete PDF links. Able to embed link to specific PDF pages. Easy to put link into specified position
convert pdf to url online; how to add pdf to website
Getting Started
R&S®EX-IQ-BOX
40
User Manual 1409.5570.32 ─ 05
Fig. 4-9: R&S
DigIConf Installation > Logon message
Windows interprets the internal SmartCard of the R&S EX-IQ-BOX as a medium for login
and therefore causes this message.
When trying to confirm, the system reacts in different ways, depending on the status of
the "DisableCAD" registry entry:
1. "Logon Message" remains
The system repeats the SmartCard error message and blocks the login. Disable-
CAD=1, i.e. the Windows security attention sequence (CTR-ALT-Del) for login is
skipped. Windows tries to log in with the smart card and fails.
To terminate:
a)
Disconnect the R&S EX-IQ-BOX to enable login.
b) Log in.
c)
Connect the R&S EX-IQ-BOX again.
Note: To solve this conflict for later operation, deactivate DisableCAD in the registry.
The DisableCAD parameter determines whether you need to press CTRL+ALT
+DEL keys to log in, or whether the login window directly appears after at startup or
after locked desktop.
2. "Logon Message" disappears
The system forwards to the "Computer Locked" dialog box. In this case, Disable-
CAD=0, Windows requires users to press CTR-ALT-Del (security attention
sequence) for login.
a) Press CTRL+ALT+DEL to unlock the computer and log in as usual.
The connection to the R&S EX-IQ-BOX may remain.
4.4.4.1 How to avoid the SmartCard Conflict
The only way to avoid the conflict reliably, is to set DisableCAD=0. If the setting has not
been modified yet, proceed as follows.
To modify this registry entry, R&S DigIConf provides the file DisableCAD.reg in the
directory:
%APPDATA%\Rohde-Schwarz\DigIConf\Registry
► Execute DisableCAD.reg to deactivate the setting, i.e. to enable the "Press Ctrl-
Alt-Del" security attention sequence.
The entry is automatically set to 0. Login can now be performed with connected
R&S EX-IQ-BOXes without conflicts.
Installing R&S DigIConf
Getting Started
R&S®EX-IQ-BOX
41
User Manual 1409.5570.32 ─ 05
R&S DigIConf also provides the file EnableCAD.reg in the installation directory to dis-
able the sequence accordingly.
4.4.4.2 DisableCAD - Background Information
The DisableCAD parameter determines whether you must press the (CTRL+ALT+DEL)
security attention sequence for windows login, or whether the login window directly
appears after startup or after locked desktop.
DisableCAD=0
This status requires users first to press CTRL+ALT+DEL, the windows security atten-
tion sequence to access the Windows login dialog box.
Fig. 4-10: Windows security attention sequence check box
The Windows dialog box opens, as shown below.
DisableCAD=1
The Windows login dialog box appears immediately after booting, or locked desktop.
Installing R&S DigIConf
Getting Started
R&S®EX-IQ-BOX
42
User Manual 1409.5570.32 ─ 05
Fig. 4-11: Windows login dialog box
The require users to "Press Ctrl-Alt-Del" check box is skipped.
4.5 Connecting the R&S EX-IQ-BOX
This section describes how to connect the R&S EX-IQ-BOX in principle, i.e. to the power
supply, to a PC, an R&S instrument and to the DUT. Connection and startup require no
particular order, but it is recommended that you follow the procedure as described below.
Connection
It is assumed that all R&S instruments in the test setup are properly power supplied and
switched on.
1. Power supply
Power supply: 30 W switching power supply adapter with an input voltage of
100 to 240 VAC.
The R&S EX-IQ-BOX is power supplied with an external power supply unit and a separate
power cable. The external power supply unit provides all required voltages of the hard-
ware.
► Connect the R&S EX-IQ-BOX to the AC supply.
The R&S EX-IQ-BOX is in ready state, if USB is already connected (POWER LED
= green). Without USB connection the device R&S EX-IQ-BOX is in standby state
(POWER LED = yellow).
Connecting the R&S EX-IQ-BOX
Getting Started
R&S®EX-IQ-BOX
43
User Manual 1409.5570.32 ─ 05
The device is still power-supplied while it is in standby mode.
2. USB Connection
To establish a connection between the R&S EX-IQ-BOX and a PC or an R&S instrument
(R&S EX-IQ-BOX 1409.5502.02), proceed as follows:
1.
Connect the USB cable plug B to the R&S EX-IQ-BOX USB IN
2. Connect the USB cable plug A to the PC or to the instrument
Device driver
If the R&S EX-IQ-BOX is connected for the first time, the Windows Hardware Wizard
requires the installation of the appropriate device driver. The same applies if you install
a new update of R&S DigIConf.
Follow the wizard instructions until windows has finished the driver installation. If the
installation is finished, a message is displayed in the info line.
The software drivers need to be installed only once for a device. Due to the operation
mode of USB, every new R&S EX-IQ-BOX needs a driver installation.
3. Data signal connection
1. Establish the connection for the reference frequency.
a)
Connect the coaxial cable to REF IN-BNC connector of the R&S EX-IQ-BOX.
b) Connect the coaxial cable to REF OUT of the instrument.
2. Establish the digital interface connection.
a) Transmitter Mode
Connect the LVDS cable between the R&S EX-IQ-BOX (DIG I/Q IN/OUT 2) and
the BASEBAND DIGITAL IN of the R&S instrument
b) Receiver Mode
Connect the LVDS cable between the R&S EX-IQ-BOX "DIG I/Q IN/OUT 2" con-
nector and the "BASEBAND DIGITAL IN" of the R&S instrument.
Connecting the R&S EX-IQ-BOX
Getting Started
R&S®EX-IQ-BOX
44
User Manual 1409.5570.32 ─ 05
On connecting the LVDS cable the R&S instruments and the R&S EX-IQ-BOX detect
the connection established between them. Depending on the instrument the indica-
tion for a successful connection differs, it is either a short message in the info line or
a graphical message.
4. Connection to the DUT
1. Connect the respective breakout board (USER INTERFACE).
2. Establish the appropriate connection to the DUT.
4.6 Installing R&S EX-IQ-BOX Options
This section explains how to install an option of the R&S EX-IQ-BOX.
Prerequisites
Before installing an option, make sure that the R&S EX-IQ-BOX is power supplied and
an USB connection is established.
Keep the license key ready that is provided with the software option.
Installation
The software options are installed on the R&S EX-IQ-BOX using R&S DigIConf.
1.
Start R&S DigIConf.
2. In the "Tools" menu, select "Tools > EX-IQ-BOX Device Manager".
The "EX-IQ-BOX Device Manager" dialog opens.
Installing R&S EX-IQ-BOX Options