embed pdf in mvc view : Adding pdf to html page SDK application API wpf html web page sharepoint EX-IQ-BOXK04_OperatingManual_en_056-part1287

Getting Started
R&S®EX-IQ-BOX
45
User Manual 1409.5570.32 ─ 05
The hardware tab indicates various information on a selected device, like part num-
ber, serial number, firmware version, and so on.
3. In the "Options" tab, select the appropriate "EX-IQ-BOX Device".
The list box lists each connected R&S EX-IQ-BOX.
Installing R&S EX-IQ-BOX Options
Adding pdf to html page - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
convert pdf to html code online; how to convert pdf into html code
Adding pdf to html page - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
convert pdf to website html; online convert pdf to html
Getting Started
R&S®EX-IQ-BOX
46
User Manual 1409.5570.32 ─ 05
For detailed description on this dialog refer to ​chapter 6.1.6.1, "EX-IQ-BOX Device
Manager", on page 65 in the operating manual.
4. To enter the license key, perform one of the follwoing:
● in the "Enter License Key" text box, enter the license key code manually.
● Select "Import License Key from File", and proceed accordingly.
5. Enter the license key provided with the option in the "Option-Key" field and confirm
with "Enter".
6. Confirm with "OK".
R&S DigIConf immediately shows the newly enabled option in the table.
Installing several options
Just repeat step 3 to install more options on the same device or steps 2 and 3 to install
options on other devices.
Checking for installed options
To check installed options proceed as follows:
1. Open the "EX-IQ-BOX Device Manager" dialog.
2. Select the R&S EX-IQ-BOX from "EX-IQ-BOX Device".
The installed options are displayed in the "Installed Options" table.
Installing R&S EX-IQ-BOX Options
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Support adding PDF page number. Offer PDF page break inserting function. DLLs for Adding Page into PDF Document in VB.NET Class. Add necessary references:
adding pdf to html page; convert pdf to html file
C# PDF Page Insert Library: insert pages into PDF file in C#.net
By using reliable APIs, C# programmers are capable of adding and inserting (empty) PDF page or pages from various file formats, such as PDF, Tiff, Word, Excel
convert from pdf to html; attach pdf to html
Application Examples
R&S®EX-IQ-BOX
47
User Manual 1409.5570.32 ─ 05
5 Application Examples
This chapter covers some application examples. The test setups show the R&S EX-IQ-
BOX controlled by R&S DigIConf. Applications with User Defined Interface transmission
protocols also support the direct control of the R&S EX-IQ-BOX by R&S Instruments.
Standardized interface protocols always require the configuration by R&S DigIConf.
5.1 Baseband Receiver Chip Test
Example of the generation of a standards-compliant digital baseband signal for checking
the quality of a receiver.
BB Chip
specific IQ format
Digital IQ data
Clock
Breakout board
R&S EX-IQ-BOX
Transmitter
mode
USB control
Digital IQ 
data
R&S Signal Generator
Reference
R&S
IQ format
Digital baseband
R&S DigIConf
Fading
Noise
Impairments
Fig. 5-1: Application example of a baseband receiver chip test
An R&S signal generator together with the R&S EX-IQ-BOX provides digital baseband
signals for all important mobile radio and wireless digital standards such as EUTRA/LTE,
3GPP, HSPA, GSM/EDGE, WiMAX IEEE 802.16 and WLAN IEEE 802.11n. All signal
generator functions are also available for generating digital baseband signals, plus all
signal processing functions to yield effects such as fading, AWGN or I/Q impairments.
This allows measurements on baseband receiver chips to be performed accurately and
Baseband Receiver Chip Test
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Perform annotation capabilities to mark, draw, and visualize objects on PDF document page. Capable of adding PDF file navigation features to your VB.NET program
convert pdf to html code c#; convert pdf into html file
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Capable of adding PDF file navigation features to your C# program. Perform annotation capabilities to mark, draw, and visualize objects on PDF document page.
how to convert pdf into html; convert pdf to html5 open source
Application Examples
R&S®EX-IQ-BOX
48
User Manual 1409.5570.32 ─ 05
reproducibly. With the aid of bit and block error ratio measurements the quality of the
receiver can be tested.
5.2 CPRI Test Setup
The following test setups show two typical CPRI test scenarios with the R&S EX-IQ-BOX.
First, the R&S EX-IQ-BOX emulates the baseband module, and in the other example, it
acts as the RF part.
5.2.1 Typical CPRI RE Test Setup
Example of a typical CPRI RE (Radio Equipment = RF unit) test scenario, where the
R&S EX-IQ-BOX acts as a baseband module REC (Remote Equipment Control).
The test setup requires the CPRI breakout board, option R&S EXBOX-B85, the CPRI RE
Test, option R&S EXBOX-K10 and the configuration software R&S DigIConf. For details
on available options, see ​chapter 3.2.2.1, "Standardized Protocols", on page 22.
CPRI RE
(Radio Equipment)
Digital IQ data
R&S
IQ format
Breakout board
R&S EX-IQ-BOX
Bidirectional 
mode
R&S
IQ format
USB control
R&S FSQ
R&S SMU200A
RX
TX
RF
Baseband
Receiver
Transmitter
R&S FSQ
Receiver
R&S SMU200A
Transmitter
R&S DigIConf
Optical or 
electrical link
Reference
CPRI link
Uplink
Downlink
Fig. 5-2: Application example of a RE test setup with the digital interface protocol CPRI
CPRI Test Setup
C# PDF insert image Library: insert images into PDF in C#.net, ASP
image adding library control for PDF document, you can easily and quickly add an image, picture or logo to any position of specified PDF document file page.
convert pdf table to html; pdf to html conversion
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
PDF in VB.NET, VB.NET convert PDF to HTML, VB.NET convert PDF to Word Provides you with examples for adding an (empty) page to a PDF and adding empty pages
converting pdf into html; pdf to html converter
Application Examples
R&S®EX-IQ-BOX
49
User Manual 1409.5570.32 ─ 05
The test setup covers the downlink and the uplink. It provides testing both directions either
simultaneously, i.e. full duplex, or uplink and downlink seperately.
The downlink signal flow
The R&S baseband signal generator feeds a baseband signal (e.g. an LTE downlink) in
the R&S specific I/Q format to the R&S EX-IQ-BOX. The R&S EX-IQ-BOX converts the
R&S I/Q format into the CPRI protocol. The CPRI link transmits the I/Q baseband signal
and control & management information from the R&S EX-IQ-BOX to the DUT, in this case
the CPRI RE Device.
The CPRI RE device extracts the baseband signal from the CPRI link and executes an
I/Q modulation to a certain carrier frequency RF. The resulting RF signal is sent to the
R&S spectrum-analyzer, to perform various measurements, e.g. ACP (Adjacent Channel
Power) or EVM (Error Vector Magnitude) evaluation.
The uplink signal flow
The R&S vector signal generator feeds an RF signal (e.g. an LTE uplink) via the antenna
input into the CPRI RE device. The DUT converts the signal from RF to baseband and
transmits the baseband signal by using the CPRI link.
The R&S EX-IQ-BOX extracts the I/Q baseband signal from the CPRI protocol and sends
the signal in the R&S specific I/Q format to the R&S signal analyzer for demodulation.
All settings regarding the baseband signal (e.g. LTE) are directly controlled by the R&S
signal generator and analyzer, respectively.
CPRI settings like I/Q mapping or link settings are controlled by the configurator software
R&S DigIConf .
In addition to the I/Q data, C&M (Control and Management) information is embedded in
the CPRI protocol. These parameters are also set with the aid of R&S DigIConf.
An Ethernet connector provides fast C&M, and the R&S DigIConf inline text console can
be used for slow C&M.
5.2.2 Typical CPRI REC Test Setup
Example of a typical CPRI REC (Radio Equipment Control = baseband unit) test scenario,
where the R&S EX-IQ-BOX acts as a RF module RE (Remote Equipment).
The test setup requires the CPRI breakout board, option R&S EXBOX-B85, the CPRI
REC Test, option R&S EXBOX-K11 and the configuration software R&S DigIConf. For
details on available options, see ​chapter 3.2.2.1, "Standardized Protocols", on page 22.
CPRI Test Setup
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
page modifying page, you will find detailed guidance on creating, loading, merge and splitting PDF pages and Files, adding a page into PDF document, deleting
embed pdf to website; convert pdf to web
C# PDF insert text Library: insert text into PDF content in C#.net
C#.NET PDF SDK - Insert Text to PDF Document in C#.NET. Providing C# Demo Code for Adding and Inserting Text to PDF File Page with .NET PDF Library.
convert pdf to website; convert pdf into web page
Application Examples
R&S®EX-IQ-BOX
50
User Manual 1409.5570.32 ─ 05
CPRI REC
(Radio Equipment Control)
Digital IQ data
R&S
IQ format
Bidirectional 
mode
R&S
IQ format
USB control
R&S SMU200A
Baseband
Transmitter
(uplink)
R&S FSQ
Receiver
(downlink)
R&S DigIConf
Optical or 
electrical link
Reference
CPRI link
Uplink
Downlink
Breakout board
R&S EX-IQ-BOX
Digital IQ data
Fig. 5-3: Application example of a REC test setup with the digital interface protocol CPRI
The test setup covers the downlink and the uplink. It provides testing both directions either
simultaneously, i.e. full duplex, or uplink and downlink separately.
The downlink signal flow
The DUT, in this case the CPRI REC device, generates a digital baseband signal (e.g.
an LTE downlink) and transmits this signal over the CPRI link.
The R&S EX-IQ-BOX extracts the I/Q baseband signal from the CPRI protocol and sends
the signal in the R&S specific I/Q format to the R&S signal analyzer for demodulation.
The R&S signal analyzer features various measuring methods, as e.g. ACP (Adjacent
Channel Power) or EVM (Error Vector Magnitude) evaluation. Use this measurement
methods to examine the validity and quality of the digital baseband signal, or to evaluate
the influence of numerical imperfections, e.g. quantization effects depending on the I/Q
resolution.
The uplink signal flow
The R&S signal generator feeds an UE uplink signal (e.g. an LTE uplink) in the R&S
specific I/Q format to the R&S EX-IQ-BOX.
The R&S EX-IQ-BOX converts the R&S I/Q format into the CPRI protocol. The CPRI link
transmits the I/Q baseband signal and control & management information from the
R&S EX-IQ-BOX to the DUT, in this case the CPRI REC device.
The DUT must now be able to demodulate the UE uplink signal. Use the various func-
tionalities of the R&S signal generator, e.g. add Channel Fading, AWGN (Additive White
Gaussian Noise) and I/Q impairments in order to perform a very powerful and realistic
receiver / demodulator measurement with this test scenario.
CPRI Test Setup
VB.NET PDF insert text library: insert text into PDF content in vb
VB.NET PDF - Insert Text to PDF Document in VB.NET. Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program.
convert pdf to html online for; convert pdf to html for online
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
text comments on PDF page using C# demo code in Visual Stuodio .NET class. C#.NET: Add Text Box to PDF Document. Provide users with examples for adding text box
how to convert pdf file to html document; how to change pdf to html format
Application Examples
R&S®EX-IQ-BOX
51
User Manual 1409.5570.32 ─ 05
All settings regarding the baseband signal (e.g. LTE) are directly controlled by the R&S
signal generator and analyzer, respectively.
CPRI settings like I/Q mapping or link settings are controlled by the configurator software
R&S DigIConf.
In addition to the I/Q data, "C&M" (Control and Management) information is embedded
in the CPRI protocol. These parameters are also set with the aid of R&S DigIConf.
An Ethernet connector provides fast C&M, and a RS-232-C connector provides slow C&M
in real time.
5.3 In-Circuit Emulation for Wireless Designs
The following test setup example requires the Cadence Palladium Breakout Board, option
R&S EXBOX-Z3, and the configuration software R&S DigIConf.
The following example shows a test setup for the emulation of a chip in a software model:
R&S DigIConf
R&S CMW500 Protocol Tester
Breakout Board
R&S EX-IQ-BOX
Frequency reference
R&S IQ format
Digital IQ data
Breakout Board
R&S EX-IQ-BOX
Frequency reference
Clock
Uplink
Downlink
Clock
R&S IQ format
Digital
IQ data
Specific IQ format
Specific IQ format
USB control
USB control
IQ data
IQ data
Fig. 5-4: Application example of an in-circuit emulation of wireless designs
This test setup shows an R&S CMW500, equipped for protocol testing which creates an
I/Q signal. The signal is then converted by an R&S EX-IQ-BOX and fed to the emulator.
A second R&S EX-IQ-BOX converts the incoming signal from the emulator and feeds it
into the baseband section of the R&S potocol tester. Both R&S EX-IQ-BOX devices are
controlled by R&S DigIConf. For detailed information on this application refer to the oper-
In-Circuit Emulation for Wireless Designs
Application Examples
R&S®EX-IQ-BOX
52
User Manual 1409.5570.32 ─ 05
ating manual of the protocol tester, and the to http://www.rohde-schwarz.com/appnote/
1CM75 on the internet.
In-Circuit Emulation for Wireless Designs
R&S EX-IQ-BOX Configuration
R&S®EX-IQ-BOX
53
User Manual 1409.5570.32 ─ 05
6 R&S EX-IQ-BOX Configuration
The versatile functionality of the R&S EX-IQ-BOX and its options provide convenient
adjustment for signal transmission between different digital interfaces and communica-
tion protocols. It supports both user defined protocols or the standardized transmission
protocol CPRI.
The configuration software R&S DigIConf enables you to configure and control the
R&S EX-IQ-BOX via PC. Some R&S instruments, as e.g. the R&S CMW500, also provide
installing R&S DigIConf on the instrument directly. Check in the operating manual to see
if your R&S instrument supports this mode of operation. Refer to ​chapter 3.1, "Basic
Operating Modes", on page 14 for description in detail.
The R&S EX-IQ-BOX, model 1409.5505.02, additionally supports direct control from an
R&S instrument in User Defined mode. Due to the enhanced capabilities of the R&S EX-
IQ-BOX 1409.5505K04, this model is controlled by R&S DigIConf exclusively, since it
supports all applications.
The following references lead you to the appropriate descriptions for using R&S DigIConf,
and configuring the R&S EX-IQ-BOX for the respective applications:
● ​R&S DigIConf Configuration Software, comprises the graphical user interface and
basic functionalities of R&S DigIConf, including configuration dialogs and basic infor-
mation on remote control.
Note: The latest software versions can be downloaded free charge from the R&S
website:
http://www.rohde-schwarz.com/product/EX-IQ-Box.html
● ​Configuration via R&S Instruments covers all specific characteristics of an R&S
instrument in conjunction with an R&S EX-IQ-BOX1409.5505.02, separately descri-
bed for every instrument family. E.g. the indication of the R&S EX-IQ-BOX in an
instrument and access to the parameters of the R&S EX-IQ-BOX in an instrument´s
dialog. This constellation applies to User Defined applications.
Separate chapters contain protocol settings of the specific operating modes:
● ​chapter 7.1, "User Defined", on page 95 covers the parameters and settings for
serial or parallel transmission of I/Q signals, including clock modes, data rates and
logical signal levels.
● ​chapter 7.2, "CPRI", on page 126 covers explanations and the description to this
standardized protocol.
6.1 R&S DigIConf Configuration Software
This chapter describes the graphical user interface of R&S DigIConf, including the layout
of the application window, the display, controls and how to operate the configuration
software R&S DigIConf. Additionally the chapter contains information on special features
R&S DigIConf Configuration Software
R&S EX-IQ-BOX Configuration
R&S®EX-IQ-BOX
54
User Manual 1409.5570.32 ─ 05
concerning the connection of the R&S EX-IQ-BOX to R&S instruments and the respective
configuration dialogs.
6.1.1 Graphical User Interface - Overview
After starting the R&S DigIConf software the main application window opens.
The appearance of the application window is based on the Microsoft®Windows layout,
covering
a header with the name of the window and buttons for minimizing and closing
a menubar with functions to file management, tools and access to the help system
a toolbar with icons for saving ore restoring instrument settings
● a display with a block diagram and the infoline
● a taskbar with softkeys showing open dialogs that are minimized
Fig. 6-1: R&S DigIConf main application window
1 =window header
2 =menu bar
3 =tool bar
4 =remote indicator
5 =block diagram
5a=connector symbol
5b=EX-IQ-BOX functional block
R&S DigIConf Configuration Software
Documents you may be interested
Documents you may be interested