D
IGITAL 
C
ONTROL 
I
NCORPORATED
DigiTrak
®
LWD
DataLog
®
Operator’s Manual
21 
Recording Drill Data  
To record pilot bore drill data, the F5 receiver must be properly programmed for and calibrated to the 
transmitter, with the calibration verified. If both pressure and drill data will be recorded, you should set up 
to record drill data before you begin the pressure log. The correct procedure for recording drill data is 
described in this section. The procedure for recording pressure-tension data is given in the next section.  
Creating a New Job  
1.  From the Locate Mode screen, hold the trigger in while pushing the toggle to the right one time to 
display the Drill DataLog Start Recording menu. 
Drill DataLog Start Recording Menu 
2.  Select Create a New Job. A keypad will appear to enter the pipe length (drill rod length) to be used for 
that bore. Enter the pipe length, then select the curved arrow button to record it as the drill rod length. 
Keypad for Entering Pipe Length (Rod Length) 
Units for pipe/rod 
length are set using 
depth units option 
on Settings menu 
Append to an 
existing job  
Create a new job 
(shown highlighted) 
Exit (returns to 
locate mode)  
Exit (returns to 
locate mode)  
Convert pdf table to html - control SDK platform:C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
www.rasteredge.com
Convert pdf table to html - control SDK platform:VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
www.rasteredge.com
Recording Drill Data
22 
DigiTrak
®
LWD
DataLog
®
Operator’s
Manual 
3.  To find the 1
st
rod length, measure from the make-up/break-out clamps to the top of the rod when the 
tool is positioned for the first data point, as shown below. For this measurement, the housing slots 
should be half above and half below the ground (or a plane parallel to the ground if drilling into a pit). 
The elevation at the first data point is the Zero Reference elevation, and is generally at the surface of 
the ground. 
Measuring the 1st Rod Length 
4.  The 1
st
rod length screen appears with a default value displayed in the 1
st
Rod Length window. The 
default 1
st
rod length is automatically calculated as 70% of your pipe length. If this number is correct 
for your bore, simply select the green checkmark to set this value. To set a different value, select the 
keypad, enter the desired value, and select the curved return arrow button. 
1st Rod Length Input Screen 
If you are using a fluid pressure transmitter, DCI recommends that you begin the pressure log at this 
time. See the Recording Fluid Pressure Data section below. 
5.  Select Exit to return the Locate Mode screen, hold the trigger, and toggle right to open the Drill 
Datalog Recording Options menu. 
Top of rod 
Slots in housing 
1
st
rod length 
Make-up/break-out 
clamps 
Drill 
carriage 
Zero elevation 
reference line  
Surface of 
ground  
Set 1
st
rod length  
to default value  
(shown highlighted) 
Select keypad to 
enter different value 
Exit (returns to 
locate mode)  
control SDK platform:C# Word - Table Processing in C#.NET
C# Word - Table Processing in C#.NET. Provide C# Users with Variety of Methods to Setup and Modify Table in Word Document. Overview. Create Table in Word.
www.rasteredge.com
control SDK platform:C# Word - Table Row Processing in C#.NET
C# Word - Table Row Processing in C#.NET. How to Set and Modify Table Rows in Word Document with C#.NET Solutions. Overview. Create and Add Rows in Table.
www.rasteredge.com
Recording Drill Data 
DigiTrak
®
LWD
DataLog
®
Operator’s Manual
23 
6.  When recording the first data point (rod 0), the only available option will be Pitch Only. With the 
receiver positioned within range of the transmitter (it does not have to be at the locate line or front 
locate point), select the Record Pitch Only icon to record the data point. The receiver beeps twice and 
returns to the Locate Mode screen. 
Drill DataLog Recording Options (Pitch Only) 
7.  Advance the drill head to the end of the first rod and position the receiver over the locate line (LL) or 
the front locate point (FLP). 
8.  Hold the trigger in and toggle right to display the Drill Data Recording Options menu, which now has 
all options enabled.  
Drill DataLog Recording Options  
9.  Select Record Depth/Pitch (or Record Pitch Only if you are not able to position the receiver at the LL 
or FLP) and click the trigger to record the second data point (rod 1). The receiver will beep several 
times and return to the Locate Mode screen. 
10. Continue drilling and recording data points at the end of each drilled rod or at partial rod intervals, 
pulling back and deleting rods if necessary. Both procedures are described in the following section. 
Record depth and pitch  
(not available)  
Record pitch only 
(shown highlighted) 
Log a blank rod 
(not available) 
Record depth/pitch  
(shown highlighted)  
Record pitch only  
Log a blank rod  
control SDK platform:C# Word - Table Cell Processing in C#.NET
C# Word - Table Cell Processing in C#.NET. Online Tutorial for Users to Set and Modify Table Cells in Word Document. Overview. Create and Add Cells in Table.
www.rasteredge.com
control SDK platform:How to C#: Convert PDF, Excel, PPT to Word
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. You maybe interested: PDF in C#, C# convert PDF to HTML, C# convert
www.rasteredge.com
Recording Drill Data
24 
DigiTrak
®
LWD
DataLog
®
Operator’s
Manual 
Recording Rods or Partial Rods 
The DigiTrak LWD software requires that data points be recorded at equally spaced intervals, such as at 
the end of each drill rod. However, when you are drilling with long drill rods and/or making significant pitch 
changes, you should record data at partial pipe length intervals. This will more accurately depict the bore 
profile and changes in topography. It is possible to record at ¼, ½, ¾, or full pipe lengths.   
The method for recording rods and partial rods is the same; however, partial rods may only be recorded 
after rod 0 (first data point) and rod 1 (second data point) have been recorded. Use the following 
procedure to record a rod or partial rod. 
1.  Position the receiver at the FLP or over the head at the LL, if possible. 
2.  Hold the trigger in and toggle right. The recording options screen will display.  
Drill DataLog Recording Options (First Screen) 
If you are recording a partial rod, you must toggle down to view the second screen of recording 
options, where you can select the partial rod option before continuing. 
Drill DataLog Recording Options (Second Screen) 
Record depth and pitch  
(shown highlighted)  
Down arrow indicates 
more options below 
(toggle down to view) 
Record pitch only  
Log a blank rod  
Record data at 
partial rod lengths 
(shown highlighted) 
View/delete rod data  
Exit (returns to 
locate mode)  
Rod length (full, 1/4, 1/2, 
3/4, or finish depending 
on whether a full or 
partial rod is selected)  
control SDK platform:C# Word - Convert Word to PDF in C#.NET
C# Word - Convert Word to PDF in C#.NET. Online C# Tutorial for Converting Word to PDF (.pdf) Document. C# Demo: Convert Word to PDF Document. Add references:
www.rasteredge.com
control SDK platform:C# Word - Convert Word to HTML in C#.NET
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. You maybe interested: PDF in C#, C# convert PDF to HTML, C# convert
www.rasteredge.com
Recording Drill Data 
DigiTrak
®
LWD
DataLog
®
Operator’s Manual
25 
After a partial rod option is chosen, the display will return to the first recording options screen but the 
partial rod value (¼, ½, ¾, or finish rod) will appear in place of 
Full Rod
” for the rod length
. If a partial 
rod data point is recorded, another data point must be recorded at the end of the rod as well. The 
“Finish Rod” option appears if
a partial rod was previously recorded.  
3.  To record the data point, select the option to record depth and pitch (or pitch only if you are not able 
to position the receiver at the LL or FLP) and click the trigger. The receiver will beep several times 
and return to the Locate Mode screen. 
Pulling Back Rods / Deleting Data from Receiver 
If you need to pull back or delete rods to redirect the tool, use the option to view/delete rod data located 
on the second screen of the DataLog Recording Options menu (shown below). The procedure for deleting 
rods follows. 
Drill DataLog Recording Options (View/Delete Rod Data) 
1.  Select the view/delete rod data option, and click the trigger. You will see a list of the recorded rods 
with the most recent rod data in the top row, which will automatically be highlighted. Only the most 
recent rod can be deleted. 
View/delete rod data 
(shown highlighted) 
control SDK platform:How to C#: Overview of Using XDoc.Word
Able to render and convert Word document to/from supported document (PDF and ODT). Empower to navigate word document content quickly via thumbnail.
www.rasteredge.com
control SDK platform:Convert Word to ODT
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate VB.NET How-to, VB.NET PDF, VB.NET Word C# Word - Convert Word to ODT in C#.NET
www.rasteredge.com
Recording Drill Data
26 
DigiTrak
®
LWD
DataLog
®
Operator’s
Manual 
View Rod Data List 
NOTE: If you have accessed the screen above and do not want to delete the data point, toggle left 
or right to exit and return to the Locate Mode screen without deleting the data point. 
2.  Click the trigger, to select the data point for the highlighted rod. The following screen will display.  
Delete Rod Screen 
3.  Select the green checkmark to delete the last rod data point. Or select exit to return to the Locate 
Mode screen without deleting the data point. 
4.  Continue these steps, highlighting a rod in the list then clicking to delete it and confirm deletion, until 
you have deleted as many rods as needed. When done, toggle to the right one time to return to the 
Locate Mode screen.   
Measuring and Documenting Last Rod 
When the drill head reaches the end of the bore and exits the ground, you must measure and document 
the length of the last rod so that you can enter it when you upload the drill data to the computer. The last 
rod measurement is the pipe length minus the length of drill rod left on the rack. For example, if you 
Survey point (appears 
blank unless value is 
entered under Survey 
Point menu option)  
Data for most 
recent rod  
Exit (returns to 
locate mode)  
Delete most recent 
rod data point 
(shown highlighted) 
control SDK platform:Convert ODT to Word
Footnote & Endnote Processing. Table Row Processing. Table Cell Processing. Annotate Word. You maybe interested: PDF in C#, C# convert PDF to HTML, C# convert
www.rasteredge.com
control SDK platform:C# Word - Header & Footer Processing in C#.NET
Create and Add Table to Footer & Header. The following demo code shows how to create table in footer and header. String docFilePath
www.rasteredge.com
Recording Drill Data 
DigiTrak
®
LWD
DataLog
®
Operator’s Manual
27 
measure 6 ft (1.8 m) from the make-up/break-out clamps to the top of the rod, then you would subtract 
6 ft (1.8 m) from the pipe length. If the pipe length is 10 ft (3.0 m), then the last rod measurement will be 
4 ft (1.2 m).  
Last Rod Measurement 
NOTE: You must write down the last rod measurement; it does not get recorded with the drill 
data in the receiver. You will need to enter the value manually after the job is uploaded 
to the computer. 
Make-up/break-out  
clamps 
Drill rods 
Slots in 
housing 
6 ft (1.8 m) rod length left on rack 
Ground surface 
(topography) 
Zero elevation 
reference line 
Drill  
head 
Termination/ 
end point 
Pipe length  
(10 ft/3.0 m) 
Drill 
Top of rod 
Recording Drill Data
28 
DigiTrak
®
LWD
DataLog
®
Operator’s
Manual 
Stopping or Pausing Recording 
You must stop the DataLog job after recording the last data point and documenting the last rod so that 
you can close the file and upload the recorded data. However, you can also pause a DataLog job and 
keep it open while navigating menu options. All DataLog jobs are closed automatically when the receiver 
shuts down. The procedure for stopping or pausing a DataLog job is described below.  
1.  Toggle down to exit the Locate Mode screen and open the drill DataLog Stop/Pause Recording 
menu.  
Drill DataLog Stop/Pause Recording Menu 
2.  Select the stop option to close the DataLog job. The drill DataLog job can then be uploaded to a 
computer with LWD software installed or opened again using the append option in the drill DataLog 
Start Recording menu. 
-OR- 
Select the pause option to keep the job open for additional recording. When you re-enter the Locate 
Mode screen and record another data point, data will continue recording on the job that was 
previously paused. 
If you want to include utilities information with your drilling data, you must log by hand the depth, 
description, rod number, and/or distance from the launch point for each utility location. When you upload 
your data to the computer, you can enter these utilities and any other landmark features so that they are 
plotted with the drill data.  
NOTE: You cannot save more than 20 runs in the receiver at any one time. If you attempt to 
store more than 20 runs before deleting data, you could lock up the receiver and lose all 
drill data it has stored. This may require the receiver to be returned to DCI for repair. 
Stop job  
Pause job  
(shown highlighted) 
Recording Drill Data 
DigiTrak
®
LWD
DataLog
®
Operator’s Manual
29 
Appending to a Job 
To add data to a drill DataLog job that has already been started and closed, you will use the append 
option in the Start Recording menu, as described below. 
1.  From the Locate Mode screen, hold the trigger in while pushing the toggle to the right one time to 
display the following screen.  
Drill DataLog Start Recording Menu 
2.  Select the option to append to an existing job. The list of drill DataLog jobs stored on the receiver will 
display as shown below. 
Sample Drill DataLog Jobs List Stored on Receiver 
3.  Select the job number you would like to open and append with more data. The drill DataLog recording 
options screen will display so that you can continue to log data points.  
4.  Continue recording rods or partial rods as described earlier in this section. 
“L” indicates a 
drill DataLog job  
(“PT” displays for 
pressure-tension 
DataLog jobs)  
Append to an  
existing job  
(shown highlighted) 
Create a  
new job 
Exit (returns to 
locate mode) 
Recording Drill Data
30 
DigiTrak
®
LWD
DataLog
®
Operator’s
Manual 
Adding a Survey Point 
If the difference in elevation between the ground level at the entrance and that at the exit of a drill path 
has been surveyed, then you can enter this value as a survey point to provide a more accurate graph of 
the bore and terrain in the LWD software. The procedure is given below. 
1.  Open the drill DataLog menu from the receiver Main menu. 
2.  Select the add survey point option (icon is shown to the right). The list of 
existing drill jobs will display. 
3.  Select the job you would like to add the survey point to. The following screen will 
display. 
Survey Point Menu 
4.  Select the keypad option. The following screen will display. 
Survey Point Keypad Menu (meters) 
Open keypad to 
enter known 
elevation difference 
(shown highlighted) 
Set survey point 
back to unknown 
(the LWD software 
will calculate the 
elevation difference) 
Survey Point 
Menu Option 
+/- option for setting 
positive or negative 
survey point value 
Units for survey 
point are set using 
depth units option 
on Settings menu 
Documents you may be interested
Documents you may be interested