6 - The Ressources 
CoDeSys V2.3 
6-61 
Recipes can be saved externally in a file via command 'Extras' 'Save Watch List' and they can be 
loaded back to  the editor via 'Extras' 'Load Watch List'. In online mode  the recipe values can be 
written to the variables on the PLC via 'Extras' 'Write Recipe'. 
'Insert' 'New Watch List' 
Short keyl: <Alt>+<X>+<N> 
This command inserts the variable(s) currently selected in a POU editor to a new watch list. This list 
will automatically be created with name "Watch<n>", whereby n is a running number starting with 0 
and used in a way that the name will be unique. 
Furthermore for this command the same is true like for 'Extras' 'Add to watch list'. 
'Insert' 'Insert watch variable' 
This command is only available in the tabular editor view of a watch list. It inserts a new line at the 
topmost position of the list and opens an edit field in column "name" for entering a new watch variable 
via the Input Assistant (see the note in Creating Watch Lists, Recipes) or by typing. 
'Insert' 'Attach watch variable' 
This command is only available in the tabular editor view of a watch list. It appends a new line at the 
end of the list and and opens an edit field in column "name" for entering a new watch variable via the 
Input Assistant (see the note in Creating Watch Lists, Recipes) or by typing. 
'Delete watch variable' 
This command is only available in the tabular editor view of a watch list. It removes the currently 
focused line and corresponds to using the <Del> key. 
'Extras' 'Add to watch list' 
Short key: <Alt>+<X>+<W> 
Out of the POU editors in the project you can directly add variables to a watch list. 
When one or multiple variables or elements are selected in an editor, they can directly be added to 
one of the existing watch lists via command 'Add to watch list' ('Extras' menu or context menu). It is 
not necessary to deactivate the Monitoring for this purpose. 
For function blocks the command only will be available, if the full instance path of a variable within the 
POU is known. 
Notes on the element selection in the POU editors:
Basically particular variables can be selected like usual for the respective editor. 
Additionally the following is true:  
  In the FBD editor all elements on the left of a selected element will automatically be 
selected too. For example also the inputs a and b of an AND box will be selected when 
you select the AND box. 
  In the Ladder editor multiple  elements can be  selected  by keeping  the  <Shift> key 
pressed while clicking on the desired elements. 
  In the ST and IL editor in the right part of the window a single variable can be selected. 
In the left part multiple lines can be selected in order to get all included variables added 
to the watch list. 
  In  the  SFC  editor  you  can  select  multiple  successive  elements  in  order  to  get  all 
included variables added to the watch list. 
  In the declaration parts of GVLs and POUs only particular variables can be selected.  
How to convert pdf into html code - application control tool:C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
www.rasteredge.com
How to convert pdf into html code - application control tool:VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
www.rasteredge.com
Watch- and Recipe Manager 
6-62 
CoDeSys V2.3 
'Extras' 'Into new watch list' 
Short key: <Alt>+<X>+<N> 
This command inserts the variable(s) currently selected in a POU editor to a new watch list. This list 
will automatically be created with name "Watch<n>", whereby n is a running number starting with 0 
and used in a way that the name will be unique. 
Furthermore for this command the same is true like for 'Extras' 'Add to watch list'. 
'Insert address range' 
Instead of a variable name an address in standard format can be entered in column "name" of a watch 
list.  
The command allows to insert all addresses of a defined address range to the watch list at one go. 
For  this  purpose  a  dialog  opens  where  you  can  specify  the  start  address  and  the  number  of 
addresses. If you define for example name="%MW0" and number = "10", then the addresses %MW0 
to %MW9 will be inserted in the watch list. 
'Extras' 'Rename Watch List' 
This command will only be available, if the 1-Window-Editor view of the Watch- and
Recipe Manager 
is opened (target-dependant!). It opens a dialog for specifying the new watch list name.
Note
:  
If the tabular view  is  used,  the  watch  list  can be renamed in  the Object Organizer via command 
'Project''Object' 'Rename'. 
'Extras' 'Save Watch List' 
With this command you can save a watch list. The dialog box for saving a file is opened. The file 
name is preset with the name of the watch list and is given the extension "*.wtc". 
The saved watch list can be loaded again with 'Extras' 'Load Watch List'. 
For example this allows to manage various "Recipes" for the same set of variables, which can be 
loaded to the PLC as currently required. 
'Extras' 'Load Watch List' 
With this command you can reload a saved watch list, for example in order to reload a certain recipe 
to the editor, so that it can be written to the PLC. The dialog box is opened for opening a file. Select 
the desired file with the "*.wtc" extension. In the dialog box that appears, you can give the watch list a 
new name. The file name is preset without an extension. 
With 'Extras' 'Save Watch List', you can save a watch list. 
'Extra' 'Monitoring Active' 
Short key: <Alt>+<X>+<M> 
This command turns off resp. on the display of the values in the Watch- and Recipe Manager. If the 
Monitoring is activated, a check (ü)  appears in front of the menu 
item.
'Extras' 'Write Recipe'  
With this command in the 
Online Mode
of the Watch- and Recipe Manager you can write the preset 
values (recipe values) into the variables. 
Note
: The command only concerns the values of that watch list, which is currently 
selected in the Watch- and Recipe Manager! 
application control tool:VB.NET PDF File Split Library: Split, seperate PDF into multiple
outputOps). Divide PDF File into Two Demo Code Using VB.NET. This outputOps). Split PDF Document into Multiple PDF Files Demo Code in VB.NET. You
www.rasteredge.com
6 - The Ressources 
CoDeSys V2.3 
6-63 
6.8.3  Watch- and Recipe Manager in the Online Mode 
Watch list "Standard" in online mode, tabular editor view 
Watch- and Recipe Manager in online mode, 1-Window-Editor view 
The 
display format
(binary, hexadecimal, decimal) of the variables values primarily depends on the 
presetting done in the Project options, category Editor, but can be changed for each particular variable 
via commands 
'Hexadecimal'
'Binary'
and 
'Decimal'
available in the context menu. 
Structured  values (arrays, structures,  or  instances of  function  blocks) are  marked  by a  plus resp. 
minus sign in front of the identifier. By clicking the plus sign with the mouse or by pressing <Enter>, 
the display of the particular components of the variable will be expanded resp. collapsed.  
If a function block variable is marked in the watch list, the associated context menu will additionally 
contain the commands 'Zoom' and 'Open instance'.   
The monitorin view in the 1-Window-Editor view can be deactivated and re-activated via command 
'Extra' 'Monitoring Active' resp. <Alt>+<X>+<M>. 
The watch variable can be preset with constant values and then in online mode the watch list be 
written to the variables on the PLC as a so-called recipe (command 'Write Recipe'). The presetting 
can also be done with the current values from the PLC. For this purpose in onlne mode the command 
'Extras'  'Read  Recipe'  is  used.  In  this  case  any  possibly  already  existing  recipe  values  will  be 
overwritten. 
New  watch  variables  can  also be  added  in  online  mode  via  variaous mechanisms.  On  this  see: 
Creating Watch Lists, Recipes. 
'Extras' 'Read Recipe' 
With  the command,  in the 
Online Mode
of the Watch- and Recipe Manager, you can replace the 
presetting of the variables (see Offline Mode) with the present value of the variables. 
application control tool:C# PDF Page Insert Library: insert pages into PDF file in C#.net
from the ability to inserting a new PDF page into existing PDF page processing functions, such as how to merge PDF document files by C# code, how to
www.rasteredge.com
application control tool:C# PDF Convert to Images SDK: Convert PDF to png, gif images in C#
An advanced .NET control able to batch convert PDF documents to image formats in C#.NET. Turn multipage PDF file into single image files respectively in
www.rasteredge.com
The Sampling Trace 
6-64 
CoDeSys V2.3 
Example:  
PLC_PRG.Counter [:= <present value>] = <present value> 
Note:  
The command only concerns the values of that watch list, which is currently selected in the Watch- 
and Recipe Manager! 
Force and Write values in the Watch- and Recipe Manager 
In online mode in each watch list you can Force values and Write values. 
In the tabular editor you can enter a value in column prepared value and thus prepare that value for 
forcing or writing on the PLC. For this purpose select the respective cell (mouseclick resp. navigation 
within the table via the arrow keys) and by a mouseclick or the <Enter> key open a dialog for entering 
the value. If they have the same data type, also the cells of multiple variables can be selected at once 
in order to get the same value prepared for all these variables. For multiselection of the cells just keep 
the <Shift> button pressed while selecting the particular cells. 
In  the  1-Window-Editor  by  a  mouseclick  on  an  specified  variable  value  you  also  can  open  a 
corresponding dialog for entering the value which should be forced or written. 
6.9  The Sampling Trace 
6.9.1  Overview and Configuration 
Sample tracing will be available as an object in the CoDeSys resources, if it is activated in the 
target 
settings
(category 'General').It can be used to trace the progression of values for variables is traced 
over a certain time. These values are written in a ring buffer (
trace buffer)
. If the memory is full, then 
the "oldest" values from the start of the memory will be overwritten. As a maximum, 20 variables can 
be traced at the same time. A maximum of 500 values can be traced per variable. 
Since the size of the trace buffer in the PLC has a fixed value, in the event of very many or very wide 
variables (DWORD), fewer than 500 values can be traced. 
Example: if 10 WORD variables are traced and if the memory in the PLC is 5000 bytes long, then, for 
every variable, 250 values can be traced. 
In order to be able to perform a trace, open the object for a 
Sampling Trace
in the 
Resources
register card in the Object Organizer. Create resp. load an appropriate trace configuration and define 
the variables to be traced. (See 'Extras' 'Trace Configuration' and 'Selection of the Variables to be 
Displayed').  
After you have created the configuration and have started the trace in the PLC ('Start Trace'), then the 
values of the variables will be traced. With 'Read Trace', the final traced values will be read out and 
displayed graphically as curves. 
Please regard:
If a task configuration is  used for controlling the program, the trace  functionality refers to the 
debug task. 
A Trace (variable values and configuration) can be saved and reloaded in project format (*.trc) or in 
XML format (*.mon). Just the configuration can be stored and reloaded via a *.tcf-file. 
Various traces can be available in a project for getting displayed. They are listed in a selection list 
('Trace') in the upper right corner of the trace window. You can select one of those to be the currently 
used trace configuration. 
'Extras' 'Trace Configuration' 
With this command you will be given the dialog box for entering the variables to be traced, as well as 
diverse trace parameters for the Sampling Trace. The dialog can also be opened by a double click in 
the grey area of the dialog Sampling Trace.  
application control tool:VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
In order to convert PDF document to Word file using VB.NET programming code, you have to integrate following assemblies into your VB.NET class application by
www.rasteredge.com
application control tool:C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
with specified zoom value and save it into stream The magnification of the original PDF page size Description: Convert to DOCX/TIFF with specified resolution and
www.rasteredge.com
6 - The Ressources 
CoDeSys V2.3 
6-65 
Dialog Box for Trace Configuration  
First define a name for the trace configuration (
Trace Name
). This name will be added to the selection 
list 'Trace' in the upper right corner of the Trace window, as soon as you have confirmed and closed 
the configuration dialog with OK. Optionally enter a 
Comment
The list of the 
Variables
to be traced is initially empty. In order to append a variable the variable must 
be entered in the field under the list. Following this, you can use the 
Insert
button or the <Enter> to 
append the variable to the list. You can also use the Input Assistant (
Help Manager
). The use of 
enumeration variables is possible.  
A variable is deleted from the list when you select the variable and then press the 
Delete
button. 
A Boolean or analogue variable (also an enumeration variables) can be entered into the field 
Trigger 
variable
 The  input  assistance can  be used  here.  The  trigger  variable  describes the  termination 
condition of the trace.   
In 
Trigger Level
you enter the level of an analogue trigger variable at which the trigger event occurs. 
You also can use an ENUM constant here. When 
Trigger edge positive
is selected the trigger event 
occurs after an ascending edge of the Boolean trigger variable or when an analogue variable has 
passed through the trigger level from below to above. 
negative
causes triggering after a descending 
edge  or  when  an  analogue variable  went  from  above  to  below. 
both
causes  triggering  for  both 
descending and ascending edges or by a positive or negative pass, whereas 
none
does not initiate a 
triggering event at all.   
application control tool:C# PDF insert image Library: insert images into PDF in C#.net, ASP
Merge several images into PDF. Insert images into PDF form field. Access to freeware download and online C#.NET class source code.
www.rasteredge.com
application control tool:C# PDF File Merge Library: Merge, append PDF files in C#.net, ASP.
C# Demo Code: Combine and Merge Multiple PDF Files into One in .NET. This part illustrates how to combine three PDF files into a new file in C# application.
www.rasteredge.com
The Sampling Trace 
6-66 
CoDeSys V2.3 
Trigger Position
is used to set the percentage of the measured value which will be recorded before 
the trigger event occurs. If, for example, you enter 25 here then 25 % of the measured values are 
shown before the triggering event and 75% afterwards and then the trace is terminated.   
The field 
Sample Rate
is used set the time period between two recordings in milliseconds resp., if 
supported  by  the  target  system,  in  microseconds.  The  default  value  "0"  means  one  scanning 
procedure per cycle.  
Select  the  mode  for  recalling  the  recorded  values  (
Recording
):  With 
Single
the  Number  of  the 
defined samples are displayed one time. With 
Continuous
the reading of the recording of the defined 
number of measured values is initiated anew each time. If, for example, you enter the number '35' the 
first display contains the first measured values 1 to 35 and the recording of the next 35 measured 
values  (36-70)  will  then  be  automatically  read,  etc.. 
Manual
selection  is  used  to  read the  trace 
recordings specifically with 'Extras' 'Read trace'.  
The recall  mode  functions  independently of  whether a trigger  variable  is set  or not. If no  trigger 
variable is set the trace buffer will be filled with the defined number of measured values and the buffer 
contents will be read and displayed on recall.  
The button 
Save
is  used  to  store  the  trace  configuration which has  been  created  in  a  file.  The 
standard window "File save as" is opened for this purpose.  
Stored trace configurations can be retrieved using the button 
Load
. The standard window "File open" 
is opened for this purpose.   
Note:
Please note that Save and Load in the configuration dialog only relates to the configuration, not to the 
values of a trace  recording (in contrast to the menu commands 'Extras' 'Save trace  values' ‘Save 
values' and ..'Load values'). 
If the field 
Trigger Variable
is empty, the trace recording will run endlessly and can be stopped by by 
'Extras' 'Stop Trace'.  
Selection of the Variables to be displayed 
The combo box es to the right, next to the window for displaying curves trace variables defined in the 
trace configuration. If a variable is selected from the list, then after the trace buffer has been read the 
variable  will  be  displayed  in  the  corresponding  color  (Var  0  green,  etc.).  Variables  can  also  be 
selected if curves are already displayed. 
A maximum of up to eight variables can be observed simultaneously in the trace window. 
6.9.2  Generating a Trace Sampling 
'Extra' 'Start Trace' 
Symbol: 
With this command the trace configuration is transferred to the PLC and the trace sampling is started 
in the PLC. 
'Extra' 'Read Trace' 
Symbol: 
With this command the present trace buffer is read from the PLC, and the values of the selected 
variables are displayed. 
Use the commands of this menu to save or reload traces (configuration + trace values) in files resp. 
from files, to load a trace from the controller to the project or to set a certain trace as that which should 
be used in the project. 
Note:
Regard the alternative way of storing and reloading traces by using the commands of menu 'Extras' 'Save 
trace values' (Project format, *.trc-Datei, ASCII) ! 
6 - The Ressources 
CoDeSys V2.3 
6-67 
'Extra' 'Auto Read' 
With this command the present trace buffer is read automatically from the PLC, and the values are 
continuously displayed.If the trace buffer is automatically read, then a check (ü) is located before the 
menu item. 
'Extra' 'Stop Trace' 
Symbol: 
This command stops the Sampling Trace in the PLC.   
6.9.3  Looking at the Sampling Trace 
Sampling Trace of Different Variables 
If a trace buffer is loaded ('Extras' 'Start Trace'), then the values of all variables to be displayed can be 
read out ('Extras' 'Read Trace' or 'Extras' 'Auto Read')and will be displayed accordingly. If no scan 
frequency has been set, then the X axis will be inscribed with the continuous number of the traced 
value. The trace buffer will be deleted as soon as the trace sampling is stopped ('Extras' 'Stop Trace').  
The status indicator of the trace window (first line) indicates whether the trace buffer is full and when 
the trace is completed. 
If a value for the scan frequency was specified, then the x axis will specify the time of the traced value. 
The time is assigned to the "oldest" traced value. In the example, e.g., the values for the last 25 
seconds are indicated. 
The Y axis is inscribed with values in the appropriate data type. The scaling is laid out in a way that 
allows the lowest and the highest value to fit in the viewing area. In the example, Var 0 has taken on 
the lowest value of 6, and the highest value of 100: hence the setting of the scale at the left edge. 
If the trigger requirement is met, then a vertical dotted line is displayed at the interface between the 
values before and after the appearance of the trigger requirement. 
'Extras' 'Cursor Mode' 
The easiest way to set a cursor in the monitoring area is to click there with the left mouse button. A 
cursor appears and can be moved by the mouse. At the top of the monitoring window the current x-
position of the cursor is displayed. In the fields next to 'Var 0', 'Var 1', ..., 'Var n' the value of the 
respective variable is shown.  
Another way is the command 'Extras' 'Cursor mode'. With this command two vertical lines will appear 
in the Sampling Trace. First they are laying one on the other. One of the lines can be moved to the 
The Sampling Trace 
6-68 
CoDeSys V2.3 
right or to the left by the arrow keys. By pressing <Ctrl>+<left> or <Ctrl>+<right> the speed of the 
movement can be increased by factor 10. 
If additionally the <Shift> key is pressed, the second line can be moved, showing the difference to the 
first one. 
'Extras' 'Multi Channel'  
With  this  command  you  can  alternate  between  single-channel  and  multi-channel  display  of  the 
Sampling Trace. In the event of a multi-channel display, there is a check () in front of the menu item. 
The multi-channel display has been preset. Here the display window is divided into as many as eight 
display curves. For each curve the maximum and the minimum value are displayed at the edge.  
In  a  single-channel  display,  all  curves  are  displayed  with  the  same  scaling  factor  and  are 
superimposed. This can be useful when displaying curve abnormalities. 
'Extras' 'Show grid'  
With  this command you can switch  on and off  the  grid  in  the  graphic  window.  When the grid  is 
switched on, a check () will appear next to the menu item. 
'Extras' 'Y Scaling' 
With  this  command  you  can  change  the  preset  Y  scaling  of  a  curve  in  the  trace  display.  By 
doubleclicking on a curve you will also be given the dialog box 'Y-scaling'.  
As long as option 
Automatic
is activated, the default scaling will be used, which depends on the type 
of the used variable. In case of enumeration variables the enumeration values will be displayed at the 
scale.  In  order  to change  the  scaling,  deactivate option 'Automatic' and enter the  number of the 
respective curve (
Channel
) and the new maximum (
maximum y scale
) and the new minimum value 
(
minimum y scale
) on the y axis. 
The channel and the former value are preset. 
Dialog Box for Setting the Y Scale 
'Extras' 'Stretch' 
Symbol: 
With this command you can stretch (zoom) the values of the Sampling Trace that are shown. The 
beginning position is set with the horizontal picture adjustment bar. With repeated stretches that follow 
one-after-another, the trace section displayed in the window will increasingly shrink in size. 
This command is the counterpart to 'Extras' 'Compress'.  
'Extras' 'Compress' 
Symbol: 
With  this  command  the  values  shown  for  the  Sampling  Trace  are  compressed;  i.e.,  after  this 
command you can view the progression of the trace variables within a larger time frame. A multiple 
execution of the command is possible. 
This command is the counterpart to 'Extras' 'Stretch'.  
6 - The Ressources 
CoDeSys V2.3 
6-69 
6.9.4  'Extras' 'Save trace values' 
Use the commands of this menu to save traces (configuration + values) to files resp. to reload them 
from files to the project. Besides that a trace can be saved in a file in ASCII-format. 
Note:
Regard  the  alternative  way  of  storing  and  reloading  traces  by  using  the  commands  of  menu  'Extras' 
'External Trace Configurations' (XML format, *.mon-file) ! 
'Save Values' 
With this command you can save a Sampling Trace (values + configuration data). The dialog box for 
saving a file is opened. The file name receives the extension "
*.trc
". 
Be aware, that here you save the traced values as well as the trace configuration, whereas 
Save 
trace
in the configuration dialog only concerns the configuration data. 
The saved Sampling Trace can be loaded again with 'Extras' 'Load Trace'. 
'Load Values' 
With this command a saved Sampling Trace (traced values + configuration data) can be reloaded. 
The dialog box for opening a file is opened. Select the desired file with the "*.trc" extension.  
With 'Extras' 'Save Values' you can save a Sampling Trace. 
'Trace in ASCII-File' 
With this command you can save a Sampling Trace in an ASCII-file. The dialog box for saving a file is 
opened. The file name receives the extension "*.txt". The values are deposited in the file according to 
the following scheme: 
CODESYS Trace 
D:\CODESYS\PROJECTS\TRAFFICSIGNAL.PRO 
Cycle PLC_PRG.COUNTER PLC_PRG.LIGHT1  
0 2 1  
1 2 1  
2 2 1 
..... 
If no frequency scan was set in the trace configuration, then the cycle is located in the first column; 
that means one value per cycle has been recorded at any given time. In the other respects, the entry 
here is for the point in time in ms at which the values of the variables have been saved since the 
Sampling Trace has been run. 
In the subsequent columns, the corresponding values of the trace variables are saved. At any given 
time the values are separated from one another by a blank space. 
The appertaining variable names are displayed next to one another in the third line, according to the 
sequence (PLC_PRG.COUNTER, PLC_PRG.LIGHT1). 
6.9.5  'Extras' 'External Trace Configurations' 
'Save to file' 
With this command a trace (configuration + values) can be saved in a file in XML format. For this 
purpose the standard dialog for saving a file opens. Automatically the file extension *.mon will be 
used. 
A *.mon-file can be reloaded to a project with command 'Load from file'. 
Workspace 
6-70 
CoDeSys V2.3 
'Load from file' 
With this command a trace (configuration + values), which is available in a file in XML format (*.mon, 
can be loaded into the project. The dialog for opening a file will open and you can browse for files with 
extension *.mon. The loaded trace will be displayed and added to the selection list in field 'Trace in the 
configuration dialog. If you want to set it as currently used project trace configuration, use command 
'Set as project configuration'. 
A *.mon-file can be created by using command 'Save to file'. 
Note:
Regard the alternative way of saving a trace by using the commands of menu  'Extras' 'Save trace values'. 
'Save to target' 
With this command in online mode a trace configuration, which is available in a file in XML format 
(*.mon), can be loaded into the controller (target).  
The standard dialog for opening a file will be available, where per default files with extension *.mon 
will be displayed. Regard in this concern the possibility to save trace configurations in *.mon-files 
(XML format) 'Save to file'. 
See also: 'Load from target' 
'Load from target’ 
With this command the trace (configuration + values) which is currently used on the controller (target) 
can be loaded to the CoDeSys project. It will be displayed in the trace window and can be set as 
active project trace configuration. 
'Set as project configuration' 
With this command the trace configuration which is currently selected in the list of available traces 
(field 'Trace' in the trace window) can be set as active configuration within the project. The selection 
list besides the currently used (top position) offers all traces which have been loaded to the project by 
command 'Load from file' from *.mon-files (e.g. for the purpose of viewing). 
6.10 Workspace 
This object in the 'Resources' tab provides an image of the currently set project options (see chapter 
4.2, Project Options). If you open it, you get the 'Options' dialog with the know categories. 
6.11 Parameter Manager 
The Parameter Manager is a a target specific component of the CoDeSys programming system and 
must be activated in the target settings. (see chapter 6.11.1).  
The  Parameter  Manager  can  be  used  to  make  variables  of  a  CoDeSys  IEC-program,  constant 
parameters or specific system parameters accessible to all CoDeSys compatible systems in a network 
for the purpose of data exchange, typically via field bus. For this purpose in the editor you can create 
parameter lists and load down to and up from the runtime system. 
Please regard
: Parameter lists also can be created resp. filled with entries via pragmas which are included in 
variable declarations (see chapter 5.2.3). 
What are Parameters ?:
In this context parameters are: 
process variables of the CoDeSys IEC project 
process independent parameters 
specific system parameters, predefined by the target system 
Documents you may be interested
Documents you may be interested