mvc display pdf in partial view : Embed pdf into html control SDK platform web page wpf .net web browser m07590333_00000000_1en40-part1647

Appendix I:  - Use of Keyboard 
CoDeSys V2.3 
10-101 
'Insert' 'Return' 
<Ctrl>+<R> 
'Insert' 'Function Block' 
<Ctrl>+<B> 
'Insert' 'Input' 
<Ctrl>+<U> 
'Extras' 'Negate' 
<Ctrl>+<N> 
'Extras' 'Zoom' 
<Alt>+<Enter> 
CFC Editor Commands 
'Insert' 'POU' 
<Ctrl>+<B>  
'Insert' 'Input' 
<Ctrl>+<E> 
'Insert' 'Output' 
<Ctrl>+<A> 
'Insert' 'Jump' 
<Ctrl>+<J> 
'Insert' 'Label' 
<Ctrl>+<L> 
'Insert' 'Return' 
<Ctrl>+<R> 
'Insert' 'Comment' 
<Ctrl>+<K> 
'Insert' 'POU input' 
<Ctrl>+<U> 
'Extras' 'Negate' 
<Ctrl>+<N> 
'Extras' 'Set/Reset' 
<Ctrl>+<T> 
'Extras' 'Connection' 
<Ctrl>+<M> 
'Extras' 'EN/ENO' 
<Ctrl>+<I> 
'Extras' 'Zoom' 
<Alt>+<Enter> 
LD Editor Commands 
'Insert' 'Network (after)' 
<Ctrl>+<T> 
'Insert' 'Contact' 
<Ctrl>+<K> 
'Insert' 'Contact (negated)' 
<Ctrl>+<G> 
'Insert' 'Parallel Contact' 
<Ctrl>+<R> 
'Insert' 'Parallel contact (negated)' 
<Ctrl>+<D> 
'Insert' 'Function Block' 
<Ctrl>+<B> 
'Insert' 'Coil' 
<Ctrl>+<L> 
'Insert' '’Set’ coil' 
<Ctrl>+<I> 
'Insert at blocks' 'Input' 
<Ctrl>+<U> 
'Insert at blocks' 'Assign' 
<Ctrl>+<A> 
'Extras' 'Negate' 
<Ctrl>+<N> 
'Extras' 'Zoom' 
<Alt>+<Enter> 
Embed pdf into html - application software cloud:C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
www.rasteredge.com
Embed pdf into html - application software cloud:VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
www.rasteredge.com
Appendix I:  - Use of Keyboard 
10-102 
CoDeSys V2.3 
SFC Editor Commands 
'Insert' 'Step-Transition (before)' 
<Ctrl>+<T> 
'Insert' 'Step-Transition (after)' 
<Ctrl>+<E> 
'Insert' 'Alternative Branch (right)' 
<Ctrl>+<A> 
'Insert' 'Parallel Branch (right)' 
<Ctrl>+<L> 
'Insert' 'Jump' 
<Ctrl>+<U> 
'Extras' 'Zoom Action/Transition' 
<Alt>+<Enter> 
Move back to the editor from the SFC Overview 
<Enter> 
Work with the PLC- resp. Task Configuration 
Open and close organization elements  
<Enter> 
Place an edit control box around the name 
<Spacebar> 
'Extras' 'Edit Entry' 
<Enter> 
Working in the Parameter Manager Editor 
Toggle between navigation window and list editor  
<F6> 
Delete a line in the list editor 
<Ctrl>+<Del> 
<Shift>+<Del> 
Delete a field in the list editor 
<Del> 
application software cloud:C# TIFF: How to Embed, Remove, Add and Update TIFF Color Profile
On the whole, our SDK supports the following manipulations. Empower C# programmers to embed, remove, add and update ICCProfile. Support
www.rasteredge.com
application software cloud:VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Embed PDF to image converter in viewer. Quick evaluation source codes for VB.NET class. Sometimes, to convert PDF document into BMP, GIF, JPEG and PNG
www.rasteredge.com
Appendix J:  - Recommendations on the naming of identifiers 
CoDeSys V2.3 
10-103 
Appendix J:   Recommendations on the naming of identifiers 
10.36 Naming of identifiers 
Identifiers are defined at the declaration of variables (Variable names), user-defined data types and at 
the creation of POUs (functions, function blocks, programs) and visualizations. You might follow the 
following recommendations concerning the naming of  identifiers in order to make it as unique  as 
possible.  
10.37 Identifiers for variables (variable names) 
The naming of variables in applications and libraries as far as possible should follow the Hungarian 
notation: 
For each variable a meaningful, short description should be found, the base name. The first letter of 
each word of a base name should be a capital letter, the others should be small ones (Example: 
FileSize). If needed additionally an translation file for other languages can be created. 
Before the base name, corresponding to the data type of the variable, prefix(es) are added in small 
letters. 
Data type 
lower limit 
upper limit 
Information 
content 
Prefix  Comment 
BOOL 
FALSE 
TRUE 
1 Bit 
x * 
reserved 
BYTE 
8 Bit 
by 
Bit  string,  not  for arithm. 
operations 
WORD 
16 Bit 
Bit  string,  not  for arithm. 
operations 
DWORD 
32 Bit 
dw 
Bit  string,  not  for arithm. 
operations 
LWORD 
64 Bit 
lw 
not for arithm. operations
SINT 
-128 
127 
8 Bit 
si 
USINT 
255 
8 Bit 
usi 
INT 
-32.768 
32.767 
16 Bit 
UINT 
65.535 
16 Bit 
ui 
DINT 
-2.147.483.648 
2.147.483.647 
32 Bit 
di 
UDINT 
4.294.967.295 
32 Bit 
udi 
LINT 
-2
63
2
63 
- 1  
64 Bit 
li 
ULINT 
2
64 
- 1 
64 Bit 
uli 
REAL 
32 Bit 
LREAL 
64 Bit 
lr 
STRING 
application software cloud:C# Raster - Image Save Options in C#.NET
NET Read: PDF Image Extract; VB.NET Write: Insert text into PDF; VB.NET How-to, VB.NET PDF, VB.NET Word, VB a zone bit of whether it's need to embed Color profile
www.rasteredge.com
application software cloud:C# TIFF: How to Insert & Burn Picture/Image into TIFF Document
Entire C# Code to Embed and Burn Image to TIFF GetPage(0); // load an PNG logo into REImage REImage powerful & profession imaging controls, PDF document, tiff
www.rasteredge.com
Appendix J:  - Recommendations on the naming of identifiers 
10-104 
CoDeSys V2.3 
TIME 
tim 
TIME_OF_DAY 
tod 
DATETIME 
dt 
DATE 
date 
ENUM 
16 Bit 
POINTER 
p  
ARRAY 
* pointedly for  BOOLean variables x is chosen as prefix, in order to differentiate from BYTE and also in order to 
accommodate the perception of an IEC-programmer (see addressing %IX0.0).  
Examples: 
bySubIndex: BYTE; 
sFileName: STRING; 
udiCounter: UDINT; 
In nested declarations the prefixes are attached to each other in the order of the declarations: 
Example: 
pabyTelegramData: POINTER TO ARRAY [0..7] OF BYTE; 
Function block instances 
and 
variables
of user-defined data types as a prefix get a shortcut for the 
FB- resp. data type name (Example: sdo). 
Example: 
cansdoReceivedTelegram: CAN_SDOTelegram; 
TYPE CAN_SDOTelegram :     (* prefix: sdo *) 
STRUCT 
wIndex:WORD; 
bySubIndex:BYTE; 
byLen:BYTE; 
aby: ARRAY [0..3] OF BYTE; 
END_STRUCT 
END_TYPE 
Local constants
(c) start with prefix c and an attached underscore, followed by the type prefix and 
the variable name. 
Example: 
VAR CONSTANT 
c_uiSyncID: UINT := 16#80; 
END_VAR  
For Global Variables (g) and Global Constants (gc) an additional prefix + underscore is attached to the 
library prefix: 
Examples: 
VAR_GLOBAL 
CAN_g_iTest: INT; 
END_VAR  
VAR_GLOBAL CONSTANT 
CAN_gc_dwExample: DWORD; 
END_VAR  
application software cloud:VB.NET TIFF: Rotate TIFF Page by Using RaterEdge .NET TIFF
formats are: JPEG, PNG, GIF, BMP, PDF, Word (Docx Visual Basic .NET class, and then embed "RasterEdge.Imaging splitting huge target TIFF file into multiple and
www.rasteredge.com
application software cloud:VB.NET Image: How to Draw and Cutomize Text Annotation on Image
NET text annotation add-on tutorial can be divided into a few on document files in VB.NET, including PDF, TIFF & license and at last you can embed the required
www.rasteredge.com
Appendix J:  - Recommendations on the naming of identifiers 
CoDeSys V2.3 
10-105 
10.38 Identifiers for user-defined data types (DUT) 
The name of each structure data type consists of a library prefix (Example: CAN), an underscore and 
a preferably short expressive description (Example: SDOTelegram) of the structure. The associated 
prefix for used variables of this structure should follow directly after the colon. 
Example: 
TYPE CAN_SDOTelegram :     (* prefix: sdo *) 
STRUCT 
wIndex:WORD; 
bySubIndex:BYTE; 
byLen:BYTE; 
abyData: ARRAY [0..3] OF BYTE; 
END_STRUCT 
END_TYPE 
Enumerations
start  with  the  library  prefix  (Example:  CAL),  followed  by  an  underscore  and  the 
identifier in capital letters.. 
Regard that in previous versions of CoDeSys ENUM values > 16#7FFF have caused errors, because 
they did not get converted automatically to INT values. For this reason ENUMs always should be 
defined with correct INT values. 
Example: 
TYPE CAL_Day :( 
CAL_MONDAY,  
CAL_TUESDAY,  
CAL_WEDNESDAY,  
CAL_THIRSDAY,  
CAL_FRIDAY,  
CAL_SATURDAY,  
CAL_SUNDAY); 
Declaration: 
eToday: CAL_Day; 
10.39 Identifiers for functions, function blocks, programs (POU) 
The names of functions, function blocks and programs consist of the library prefix (Example: CAN), an 
underscore and an expressive short name of the POU (Example: SendTelegram). Like with variables 
always the first letter of a word of the POU name should be a capital letter, the others should be small 
letters. It is recommended to compose the name of the POU of a verb and a substantive. 
Example: 
FUNCTION_BLOCK CAN_SendTelegram (* prefix: canst *) 
In the declaration part a short description of the POU should be provided as a comment. Further on all 
inputs
and 
outputs
should be provided with 
comments
. In case of function blocks the associated 
prefix for set-up instances should follow directly after the name. 
Actions
get no prefix; just actions which should be called only internally, i.e. by the POU itself, start 
with „prv_“. 
Each 
function
- for the reason of compatibility with previous CoDeSys versions - must have at least 
one parameter. 
External functions
must not use structures as return values. 
application software cloud:VB.NET Image: VB.NET Code to Add Rubber Stamp Annotation to Image
Suitable for VB.NET PDF, Word & TIFF document managing & editing project. VB Can be implemented into both Windows and web VB.NET applications; Support single or
www.rasteredge.com
application software cloud:C# PDF url edit Library: insert, remove PDF links in C#.net, ASP.
and active html links in .NET WinForms. Able to insert and delete PDF links. Able to embed link to specific PDF pages. Easy to put link into specified position
www.rasteredge.com
Appendix J:  - Recommendations on the naming of identifiers 
10-106 
CoDeSys V2.3 
10.40 Identifiers for Visualizations 
Note:  Currently  you  must  avoid that a  visualization  has  the  same name  like another POU in the 
project. This would lead to problems in case of changes between visualizations. 
Appendix K:  - Compiler Errors and Warnings 
CoDeSys V2.3 
10-107 
Appendix K:   Compiler Errors and Warnings 
If errors are detected during the compilation of the project, messages will be dumped in the message 
window. Also warnings might be displayed there. <F4> always allows to jump to the next message 
line  in  this  window,  whereby  also  the  concerned  POU  will  be  opened.  The  error  and  warning 
messages are preceded by unique numbers. If a message line is selected in the message window, 
<F1> will open the corresponding online help window. 
10.41 Warnings 
1100 
"Unknown function '<name>' in library." 
An external library is used. Please check, whether all functions, which are defined in the .hex file, are 
also defined in the .lib file. 
1101 
"Unresolved symbol '<Symbol>'." 
The code generator expects a POU with the name <Symbol>. It is not defined in the project. Define a 
function/program with this name. 
1102 
"Invalid interface for symbol '<Symbol>'." 
The code generator expects a function with the name <Symbol> and exactly one scalar input, or a 
program with the name <Symbol> and no input or output. 
1103 
"The constant '<name>' at code address '<address>' overwrites a 16K page boundary!" 
A string constant exceeds the 16K page boundary. The system cannot handle this. It depends on the 
runtime system whether the problem could be avoided by an entry in the target file. Please contact the 
PLC manufacturer.  
1200 
"Task '<name>', call of '<name>' Access variables in the parameter list are not updated" 
Variables, which are only used at a function block call in the task configuration, will not be listed in the 
cross reference list. 
1300 
"File not found '<name>'" 
The file, to which the global variable object is pointing, does not exist. Please check the path. 
1301 
"Analyze-Library not found! Code for analyzation will not be generated." 
The analyze function is used, but the library analyzation.lib is missing. Add the library in the library 
manager. 
1302 
"New externally referenced functions inserted. Online Change is therefore no longer possible!" 
Since the last download you have linked a library containing functions which are not yet referenced in 
the runtime system. For this reason you have to download the complete project. 
Appendix K:  - Compiler Errors and Warnings 
10-108 
CoDeSys V2.3 
1400 
"Unknown Pragma '<Name>' is ignored!" 
This pragma is not supported by the compiler. See keyword ‘pragma’ for supported directives. 
1401 
"The struct '<name>' does not contain any elements." 
The structure does not contain any elements, but variables of this type allocate 1 Byte of memory.  
1410 
"'RETAIN' and 'PERSISTENT' do not have any effect in functions" 
Remanent variables which are defined locally in functions are handled like normal local variables. 
1411 
"Variable '<name>' in the variable configuration isn't updated in any task" 
The top level instance of the variable is not referenced by a call in any task. Thus it will not be copied 
from the process image.  
Example: 
Variable Configuration: 
VAR_CONFIG 
plc_prg.aprg.ainst.in AT %IB0 : INT; 
END_VAR 
plc_prg: 
index := INDEXOF(aprg); 
The program aprg is referenced but not called. Thus plc_prg.aprg.ainst.in never will get the actual 
value of %IB0. 
1412 
"Unexpected token '<Name>' in pragma {pragma name}" 
You are using a pragma which is not written correctly resp. which cannot be used at this location. See 
keyword 'pragma' in the CoDeSys Online Help or Users Guide for getting help for a correction. 
1413 
"'<Name>' is not a valid key for list '<Name>'. The key will be ignored" 
In the pragma a nonexistent parameter list is specified. Check the list name resp. have a look in the 
Parameter Manager for the currently available lists. 
1414 
“Too many component definitions in pragma '<Name>'” 
The  Pragma  contains  more  definitions  (in  square  brackets)  than  there  are  elements  in  the 
corresponding array, functionblock or structure.  
1415 
"’<Name>’ (<Number>): The literal '<Number>' is assigned to more than one enumeration" 
In  the  declaration  of  enumeration  <Name>  the  same  number  is  assigned  to  more  than  one 
enumeration components (e.g. TYPE aenum (a:=1, b:=1); END_TYPE).  
1500 
"Expression contains no assignment. No code was generated." 
The result of this expression is not used. For this reason there is no code generated for the whole 
expression. 
Appendix K:  - Compiler Errors and Warnings 
CoDeSys V2.3 
10-109 
1501 
"String constant passed as 'VAR_IN_OUT': '<Name>' must not be overwritten!" 
The constant may not be written within the POU, because there no size check is possible. 
1502 
"Variable '<Name>' has the same name as a POU. The POU will not be called!" 
A variable is used, which has the same name like a POU.  
Example: 
PROGRAM a 
... 
VAR_GLOBAL 
a: INT; 
END_VAR 
... 
a; (* Not POU a is called but variable a is loaded. *) 
1503 
"The POU ‘<name>’ has no outputs. Box result is set to 'TRUE'." 
The Output pin  of  a  POU  which  has no  outputs,  is  connected in FBD  or KOP.  The  assignment 
automatically gets the value TRUE. 
1504 
"’<name>’ (‘<number>’): Statement may not be executed due to the evaluation of the logical 
expression" 
Eventually not all branches of the logic expression will be executed. 
Example:  
IF a AND funct(TRUE) THEN .... 
If a has is FALSE then funct will not be called. 
1505 
"Side effect in '<Name>'! Branch is probably not executed !" 
The first input of the POU is FALSE, for this reason the side branch, which may come in at the second 
input, will not be executed. 
1506 
"Variable '<name>' has the same name as a local action. The action will not be called!" 
Rename the variable or the action. 
1507 
"Instance '<name>' has the same name as a function. The instance will not be called." 
You call in ST an instance which has the same name like a function. The function will be called ! Use 
different names. 
1509 
"'<name>' ('<number>'): Functions to be registered as callbacks have to start with 'Callback'." 
You are using a callback function, the name of which does not start with “callback”. This can cause 
unexpected effects on RISC resp. Motorola 68K controllers! 
Appendix K:  - Compiler Errors and Warnings 
10-110 
CoDeSys V2.3 
1510 
"Operand to be rotated has no explicit type. Please use a typed literal, like 'DWORD#1'." 
For the constant used in  the ROL resp.  ROR operation there must  be a data type definition. For 
information on typed constants see HERE. 
1511 
"Operand to be shifted has no explicit type. Please use a typed literal, like 'DWORD#1'." 
For the constant  used  in the SHL  resp. SHR operation there must  be a  data type definition.  For 
information on typed constants see HERE. 
1550 
"Multiple calls of the POU '<Name>' in one network may lead to undesired side effects" 
Check, whether the multiple call of this POU is really necessary. By a multiple call unwanted value 
overstrikes may occur. 
1600 
"Open DB unclear (generated code may be erroneous)." 
The original Siemens program does not tell, which POU is opened. 
1700 
"Input not connected." 
An input box is used in CFC which has no assignment. For this no code will be generated. 
1750 
"Step '<Name>': the minimal time is greater than the maximal time!" 
Open dialog 'Step attributes' for this step and correct the time definitions. 
1800 
"<name>(element #<element number>): Invalid watchexpression '<name>'" 
The visualization element contains an expression which cannot be monitored. Check variable name 
and placeholder replacements. 
1801 
"'<name> (number): No Input on Expression '<name>' possible" 
In the configuration of the visualization object at field input a composed expression is used. Replace 
this by a single variable. 
1802 
"<Visualization object>(Element number): Bitmap '<name>' was not found" 
Make sure, that an external bitmap-file is available in that path which is defined in the visualization 
configuration dialog. 
1803 
"'<name>'('<number>'): "The print action would not supported for web- and target 
visualization" 
A print action is assigned to an alarm configured in the visualization. This will not be regarded in the 
Web- or Target-Visualization. 
Documents you may be interested