Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 11 of 24 
   Shape files created from DWG or DGN files should be checked to ensure they meet 
requirements 
 Clients converting files to DWG or DGN can view and check their files using Bentley 
View. The software is available as a free download at Bentley Products and search for 
Bentley View. 
Bentley 
 Polygons with linework less than 0.8m threshold apart will not be accepted by the 
process. DWG or DGN files below this threshold may need to be modified to meet this 
requirement. However, the PDF plan which governs the plan of record must reflect true 
measurements. 
 The align command can be used to geo-reference AutoCAD files if they have been 
created using local or other coordinates. 
In command field key in align 
Select an area that encloses all elements in the file and press enter 
Select first ATS point 
Enter coordinates for that point from the March 2005 ATS coordinate file 
Select second ATS point 
Enter coordinates for that point from the March 2005 ATS coordinate file 
Press enter to end coordinate process 
Select Yes when asked to scale objects  
6.0 Digital Submission Requirements 
6.1 CAD Submission Package 
Two (2) files are required to be submitted with each digital CAD submission. The files must 
be contained within a zipped (.zip) file before submitting to PCS. 
1. Drawing (CAD) file .dgn or .dwg must be geo-referenced as indicated in Section 5.2 
geo-referenced and structured according to the layer and content requirements in 
Section 5.1.2 CAD files. 
2. PDF file is the plan of record and must contain all data listed in the plan standards 
documents and be formatted as described in section 5.1.1 PDF file. 
6.2 Shape Submission Package 
Ten (10) files are required to be submitted with each digital shape submission.  Refer to 
Content Requirements available at the department website and searching Plan Information for 
exact file requirements and refer to the Digital Plan Submission Standards and Procedures.  
The files must be contained within a zipped (.zip) file before submitting to PCS. 
1. Three (3) shape files (.shp) structured according to the “ESRI Shape File Technical 
Description” document dated July 1998 and as per section 5.1.3.  Shape file are 
located on the ESRI website and by searching for library and then the document. 
ESRI Canada  
2. Three (3) index files (.shx) One (1) for each of the shape files.  
3. Three (3) dBASE tables (.dbf) One (1) for each of the shape files. 
Conversion pdf to html - Convert PDF to html files in C#.net, ASP.NET MVC, WinForms, WPF application
How to Convert PDF to HTML Webpage with C# PDF Conversion SDK
converting pdf to html email; how to change pdf to html format
Conversion pdf to html - VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.net, ASP.NET MVC, WinForms, WPF application
PDF to HTML Webpage Converter SDK for VB.NET PDF to HTML Conversion
convert pdf table to html; convert pdf to html online for
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 12 of 24 
4. PDF file is the plan of record and must contain all data listed in the plan standards 
documents and be formatted as described in section 5.1.1 PDF file. 
6.3 Plan Confirmation Service (PCS) 
This service will allow for input of metadata, check the submission package for viruses and 
add a confirmation text file (.txt).  Once the digital file is validated the service will zip all the 
files and encrypt the package.   
The web application checks that the submission has a ZIP extension.  If the extension is not 
available the submission is not accepted by the system and the submitter must try again. 
Note: PCS does not check to ensure that the geo-referencing was completed correctly. The 
geo-referencing should be checked for correctness prior to submitting submission package to 
PCS 
6.4 Internet Requirements 
There are no special internet requirements to connect to the URL for a submission.   
To access the PCS system you must have Internet access and a Web browser that supports 
SSL 3.0 (ie Netscape or Internet Explorer). Although older versions may work the 
Department supported standard is Internet Explorer 7.0. Some browsers have security 
features that prohibit the downloading of cookies.  Your browser must be set to allow session 
cookies.  The session cookie is removed once you have logged out or closed your browser. 
6.5 Hours of Operation 
The Plan Confirmation Service is not available for 15 minutes daily between 4:00 and 4:15 
a.m. 
6.6 Getting a GoA Account 
You will require a GoA account/username and password to log into ESRD SecureXNET in 
order to access PCS. The GoA User ID Request Form is available at the department website. 
To view, click the tab for Forms, Maps, Services and search for User IDs & Client IDs for 
access to Industry Online Services for access to PCS, EDS, LAT, IWCP and PHAP.  Please 
allow 7 to 10 business days for processing. 
Every 60 days email notification will be sent to the account holder’s email address requesting 
the password be changed.   
Phone enquiries regarding accounts should be directed to: 
Business Operations Unit 
eds.support@gov.ab.ca
Online Convert PDF to HTML5 files. Best free online PDF html
area. Then just wait until the conversion from PDF to HTML is complete and download the file. The perfect conversion tool. Your HTML
how to convert pdf to html code; convert pdf into web page
C# PDF Converter Library SDK to convert PDF to other file formats
C#.NET PDF to HTML Conversion. Using provided C# code example, fast conversion from PDF to HTML can be achieved. C#.NET PDF to SVG Conversion.
convert pdf to url online; pdf to html converters
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 13 of 24 
Note:  AEP performs account audits semi-annually.  You are required to respond accordingly 
to these audits via email to retain your account access.   
6.7 Online Service Login Page 
Plan Confirmation Service clients will be required to perform the following steps to access 
the PCS: 
Open a Web Browser (Internet Explorer, Netscape or Mozilla Firefox).  The web application 
will place a cookie in your system during your session.  The cookie is removed once you 
have logged out. 
Within the address bar of your browser type the following URL: 
https://securexnet.env.gov.ab.ca/pcs_login.html    
An ESRD SecureXNET window is displayed: 
Click 1) Please proceed to…the Plan Confirmation Service 
The user must enter their assigned GoA Username and Password
Select GoA CLIENT from the Account Type drop-down box. 
Select the LOGIN button to continue.  
The system will return an error message if either the password or GoA username is incorrect.   
Once logged in to PCS, an active session is opened. The user can leave the current session 
inactive to a maximum of fifteen (15) minutes. After 15 minutes of idle time or inactivity, the 
session expires and you may have to re-login to continue.  The cookie expires once four hours 
have lapsed; you will also be prompted to re-login to connect to the PCS upload area. 
.NET PDF Document Viewing, Annotation, Conversion & Processing
XDoc.PDF SDK for .NET. RasterEdge XDoc.PDF for .NET is a professional .NET PDF solution that provides complete and advanced PDF document processing features.
converter pdf to html; convert pdf to html email
VB.NET PDF Converter Library SDK to convert PDF to other file
Conversion of PDF to Html5. For how to convert PDF to HTML document in VB.NET application, a simple and easy VB.NET sample code is given on this page for you
convert pdf to html with images; convert pdf to html code
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 14 of 24 
6.8 Web Application Upload Page 
Target File - You may key in the digital submission file name including the path to the file 
or choose to browse your system for the file. Ensure that there is no use of space or any 
special characters as part of the file name path. 
Submission Type – You must select either CAD or Shape  
Projection/Datum – You must select the correct Projection/Datum for your submission. If 
you selected Shape as your submission type projection defaults to geographic and CAD 
version will be blank. 
CAD Version – If you selected CAD as your submission type you must select the correct 
CAD version of your submission. Please check 5.1.2 for a list of valid CAD versions. 
Legal Land Description – You must add a minimum of one (1) legal land description that 
is occupied by the submitted activity. 
Section/TWP/RGE/Mer – Once you have selected your land description you can add it by 
clicking on the add button. Added lands can be removed one at a time by highlighting the 
land and clicking remove or can all be removed by clicking clear. 
Next – When you have completed all requirements click on the next button  
The submission is checked for viruses and required files. 
Cancel – Pressing the button will clear your selections 
C# Windows Viewer - Image and Document Conversion & Rendering in
CSV Document Conversion. RasterEdge Windows Viewer SDK provides how to convert TIFF: Convert to PDF. Convert to Various Images. PDF Document Conversion.
converting pdfs to html; convert pdf to website
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
PDF Conversion. • Convert PDF to Microsoft Office Word (.docx). • Convert PDF to Tiff image (.tif, .tiff). • Convert PDF to HTML (.htm, .html).
best pdf to html converter online; best website to convert pdf to word online
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 15 of 24 
If the submission is successful a metadata window will open. 
The metadata is required to help coordinate and manage the plan and files submitted digitally 
to LD in support of an application for a disposition on public land. The application collects 
the metadata about the digital file.  This tool is similar to the Digital Submission Software 
(DiPS) used by surveyors to create metadata that is submitted to Land Titles for registering 
plans.   
C# Word - Word Conversion in C#.NET
And detailed C# demo codes for these conversions are offered below. C# Demo Codes for Word Conversions. Word to PDF Conversion. PDF to Word Conversion.
convert pdf form to web form; convert pdf to url
C# powerpoint - PowerPoint Conversion & Rendering in C#.NET
And detailed C# demo codes for these conversions are offered below. C# Demo Codes for PowerPoint Conversions. PowerPoint to PDF Conversion.
convert pdf into html email; convert pdf to html link
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 16 of 24 
Once you have completed identifying all the metadata about the submission, click next.  PCS 
displays the Northing/Easting data which can be used to confirm the geo-reference used to 
create part of the design file.  If these values coincide, click ’Proceed’ to submit.  
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 17 of 24 
When the submission is successful the service assigns a sequential confirmation number.  The 
number will be six numeric digits long and will be prefixed with the year.  For example, the 
confirmation number would appear as 2015019728. 
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 18 of 24 
You must click on the HERE link to download a copy of the zip file.  The package will 
contain a copy of the PDF plan and an encrypted file to submit to the EDS system.  The file 
will have an extension of .ENC.  Submitters must not open the encrypted file as it could 
corrupt its contents. Should you wish to submit another package using PCS, click the ‘New 
Submission’ button.  To end your PCS session, you can use the logout link as shown. 
6.9 Unsuccessful Submission 
CAD Processing Error Messages and Abnormal Termination Criteria 
During FME processing when one or more validation conditions are not met, the processing 
stops and an error message gets generated.  The error message appears on a PCS screen as a 
result of validation.  The conditions with their corresponding error messages are as follows: 
1) Condition: No existing Disposition Boundary Area features on Layer 28 and/or no line 
work could be converted to a Disposition Boundary Area; 
PCS ERROR MESSAGE: No Disposition Boundary Area could be found and/or 
converted from line work found on Layer 28. 
The system will terminate processing 
2) Condition: There exists no valid Disposition Text Node located on Layer 40.   
PCS ERROR MESSAGE: There exists no valid Disposition Type Text Node available for 
processing on Layer 40. 
The system will terminate processing 
3) Condition: No Disposition Boundary Area intersects any ATS section entered through 
PCS Entry Screen. 
PCS ERROR MESSAGE: The Disposition Boundary does not intersect with the following 
<legal description>. 
The system will terminate processing 
4) Condition: There exists a Disposition Boundary Area that doesn’t have a Text Node 
located within its boundary.   
PCS ERROR MESSAGE: There exists a Disposition Boundary Area (Layer 28) that 
doesn’t have a corresponding Text Node (Layer 40) located within its boundary. 
The system will terminate processing 
5) Condition: There exists a Disposition Type Text Node that is not located within any 
Disposition Boundary Area. 
PCS ERROR MESSAGE: There exists a Disposition Type Text Node (Layer 40) that is 
not located within any corresponding Disposition Boundary Area (Layer 28). 
The system will terminate processing 
6) Condition: The number of valid Disposition Type Text Node(s) doesn’t equal the number 
of Disposition Boundary Area(s). 
PCS ERROR MESSAGE: The number of valid Disposition Type Text Nodes (Layer 40) 
must equal the number of Disposition Boundary Areas (Layer 28). 
The system will terminate processing 
7) Condition: On Layer 28 there exists an invalid geometry that cannot be fixed. 
PCS ERROR MESSAGE: Invalid Geometry found on Layer 28 – <reason for failure>. 
Please ensure that all area and/or line work is topologically clean. 
The system will terminate processing 
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 19 of 24 
FME CAD Processing Warning Messages  
During FME processing a warning message can be generated.  The warning message later 
appears on a PCS screen as a result of validation.  Generating a warning message doesn’t 
cause the processing to stop.  The conditions with their corresponding warning message are as 
follows: 
1) Condition: There exists line(s) on Layer 28 that couldn’t be converted to a Disposition 
Area. 
PCS WARNING MESSAGE: There exist(s) unused lines line(s) found on Layer 28 that 
could not be converted a Disposition Boundary Area. This may result in an incorrect 
representation of the Disposition Boundary. 
2) Condition: In the submitted CAD file on Layer 28 there exists an invalid geometry that 
can or cannot be fixed.  
PCS WARNING MESSAGE: Invalid Geometry found on Layer 28 – <reason for failure>. 
This may result in an incorrect representation of the Disposition Boundary. 
FME Shapefile Processing Error Messages and Abnormal Termination Criteria 
During FME processing when one or more validation conditions are not met, the processing 
stops and an error message gets generated. That error message later appears on a PCS screen 
as a result of validation. The conditions with their corresponding error messages are as 
follows: 
1) Condition: No Disposition Boundary Area is available for processing.  
PCS ERROR MESSAGE: There is no Disposition Boundary Area available to be 
processed. 
The system will terminate processing 
2) Condition: No Disposition Boundary Area intersects any ATS section entered through 
PCS Entry Screen. 
PCS ERROR: The Disposition Boundary does not intersect with the following <legal 
description>. 
The system will terminate processing 
3) Condition: Disposition Type is not alphabetic.   
PCS ERROR: Invalid attribute <disposition type> contained within field “DISP_TYPE”. 
The system will terminate processing 
4) Condition: Disposition Type length is longer than 3 characters (whitespaces removed).  
PCS ERROR: Invalid attribute <disposition type> contained within field “DISP_TYPE”. 
The system will terminate processing 
5) Condition: In the submitted shape file there exists a Disposition Area(s) with invalid 
geometry that cannot be fixed.  
PCS ERROR: Invalid Geometry found in the submitted shapefile - '<reason for failure>'. 
Please ensure that all geometry is topologically clean. 
The system will terminate processing 
Oct 22, 2015
Digital Plan Submission Standards and Procedures 
© 2015 Government of Alberta 
Page 20 of 24 
FME Shapefile Processing Warning Messages  
During FME processing a warning message can be generated.  The warning message later 
appears on a PCS screen as a result of validation.  Generating a warning message doesn’t 
cause the processing to stop.  The conditions with their corresponding warning message are as 
follows: 
1) Condition: In the submitted shapefile there exists a Disposition Area with invalid 
geometry that can or cannot be fixed.  
PCS WARNING MESSAGE: Invalid Geometry found in the submitted shapefile - 
'<reason for failure>'. Please ensure that all geometry is topologically clean. This may 
result in an incorrect representation of the Disposition Boundary. 
7.0 Quality Assurance 
7.1 Technical Check 
The service uses Feature Manipulation Engine (FME) to perform CAD layer/level and Shape 
validations.  The following shows the element type and the PCS validations performed: 
AutoCAD DWG v.2006  
AutoCAD 2006 
Element Types
Bentley View 
PCS 
Line 
Line 
Line 
Construction Line 
Line 
Line 
Polyline 
Line String 
Line 
Polygon 
Arc 
Area 
Rectangle 
Shape 
Area 
Arc 
Arc 
Arc 
Circle 
Circle 
Ellipse 
Revision Cloud 
Complex Shape, Arc 
Area 
Spline 
BSpline Curve 
Line 
Ellipse 
Ellipse 
Area 
Ellipse Arc 
Arc 
Ellipse 
Point 
Shared Cell Point Display 
Point 
Multi-line Text 
Text Node, Text 
Text 
Single-line Text 
Text 
Text 