mvc return pdf : Convert pdf image to text Library control API .net web page windows sharepoint Modbus%20Ethernet6-part1442

Configuration
61
MBTCP DAServer User’s Guide
3. Add a new device group or select an existing device group.
4. Right-click on the device group name, then select Edit from the shortcut 
menu.
The Device Group Parameters dialog box is displayed.
5. In the Device Group Parameters dialog box, select the Support 
Unsolicited Messages check box.
6. Click the OK button to close the dialog box.
Note  Since the status of Support Unsolicited Messages check box cannot be 
readily viewed from the Device Groups tab, proper naming of device groups 
which support unsolicited messages is strongly recommended.
7. Save the configuration change by clicking the Save icon located at the 
upper-right corner of the configuration view pane.
Note  For more information on unsolicited messages, see Unsolicited Message 
Handling.
To configure default update intervals
1. To configure a default update interval for the object, right-click in the 
Device Groups dialog box.
2. Select Config Default Update Interval from the shortcut menu.
To make changes on update intervals
A change on an update interval for an object can be made as follows:
• 
Double-click on the value to be modified in the Update Interval column 
and make the change.
Convert pdf image to text - Library control API:C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net, ASP.NET MVC, WinForms, WPF application
C# PDF to Text (TXT) Converting Library to Convert PDF to Text
www.rasteredge.com
Convert pdf image to text - Library control API:VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net, ASP.NET MVC, WinForms, WPF application
VB.NET Guide and Sample Codes to Convert PDF to Text in .NET Project
www.rasteredge.com
62
Chapter 2
MBTCP DAServer User’s Guide
Update Interval is the frequency (in milliseconds) that the DAServer 
acquires data from the topics associated with that device group.
Different topics can be polled at different rates in a PLC by defining 
multiple device-group names for the same PLC and setting a different 
Update Interval for each device group.
If you also select the "Support Unsolicited Message" checkbox as 
described above, duplicate updates could be received by the items 
associated with the device group. To avoid duplicate updates, set the 
Update Interval to 0 (zero).
Note  When you select another part of the MBTCP DAServer tree hierarchy, 
you are prompted to save the modifications to the configuration set.
Each configuration view associated with nodes/objects in the DAServer 
hierarchy tree has a common feature, the Save button.
1. When you modify any parameters in the Device Groups dialog box, click 
Save to save and implement the new modifications.
If you do not click Save, the configuration is reset to its original 
condition (since the last save).
2. After all modifications, you must save when prompted for the new data to 
be saved to the configuration set.
Device Item Definitions
The Device Items tab in the New_<Name>PLC_000 Parameters 
configuration view is used to define aliases to actual PLC items. The Device 
Items dialog box is the place where the following activities are performed:
• 
Creating new device item definitions for PLC items.
• 
Modifying the existing device items.
• 
Deleting device items.
• 
Archiving the created list of device items to a .csv file, a file with values 
separated by commas.
• 
Importing a .csv file into the Device Items tab.
Each device item definition should contain a unique name for the PLC 
associated with it.
The Device Items dialog box has the following two columns:
• 
Name: This column defines the alias names to actual PLC items.
• 
Item Reference: The actual PLC item names, linked to the created aliases, 
are defined in this column.
For example:
Library control API:C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
www.rasteredge.com
Library control API:C# PDF Image Extract Library: Select, copy, paste PDF images in C#
PDF ›› C# PDF: Extract PDF Image. How to C#: Extract Image from PDF Document. Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document.
www.rasteredge.com
Configuration
63
MBTCP DAServer User’s Guide
For Modicon holding register 400001 and 400010, the following entries can be 
created.
Note  When you create or add a new device item, a unique name needs to be 
entered for it.
Once the Device Items feature is utilized to configure item names, it provides 
the DAServer with the capability to perform OPC Item browsing. When the 
DAServer is running and an OPC client requests item information, the 
configured items will show up under the PLC hierarchy node.
To create or add device items
1. Right-click in the Device Items dialog box.
2. Select the Add command from the shortcut menu.
A device item is created in the Name column, and it is numerically 
named by default. 
For example, Item_0, Item_1, and so on.
3. Change the default name by double-clicking on it and entering the new 
name.
Enter a unique name for the new device item.
For example, "Holding1."
To add item references
Item references for each of the device items that have been created can be 
added as follows:
1. In the Item Reference column, double-click on the area in the same 
horizontal line as the selected device item.
Name
Item Reference
Holding1
400001
Holding10F
400010 F
Library control API:VB.NET PDF Image Extract Library: Select, copy, paste PDF images
Home ›› XDoc.PDF ›› VB.NET PDF: Extract PDF Image. Support PDF Image Extraction from a Page, a Region on a Page, and PDF Document in VB.NET Project.
www.rasteredge.com
Library control API:C# PDF insert image Library: insert images into PDF in C#.net, ASP
Free PDF image processing SDK library for Visual Studio .NET program. Powerful .NET PDF image edit control, enable users to insert vector images to PDF file.
www.rasteredge.com
64
Chapter 2
MBTCP DAServer User’s Guide
2. Type in the actual PLC item name in the frame that appears.
For example, "400001."
3. Click anywhere in the dialog box or press the ENTER key to have the 
change take effect.
Note  System items are not valid item reference, but DAServer-specific 
system items are ok.
To rename a device item from the list
1. Right-click on the device item to be renamed.
2. Select  the Rename command from the shortcut menu and enter the new 
device item name.
3. Click anywhere in the dialog box or press the ENTER key to apply the 
change.
To delete a device item from the list 
1. Right-click on the device item to be deleted.
2. Select the Delete command from the shortcut menu.
The device item and its corresponding actual PLC item name will be 
deleted from the dialog box.
Note  When you select another part of the MBTCP DAServer tree hierarchy, 
you are prompted to save the modifications to the configuration set.
To clear all device items
1. Right-click anywhere in the Device Items dialog box.
2. Select the Clear All command from the shortcut menu.
All the device items listed in the dialog box, including their 
corresponding actual PLC item names, will be deleted.
The Export and Import features on the shortcut menu of the Device Items 
dialog box enable you to export and import the DAServer device item data to 
and from a CSV file, after the configuration of the Device Items has been 
completed. These features provide you with the following capabilities:
• 
Archive lists of device items.
• 
Import an archived list of device items into the Device Items dialog box 
when you need to utilize or reconfigure any of the device items on the 
archived list.
• 
Perform an off-line, large-scale edit on the item data configured for a 
device item list.
• 
Import what has been edited back into the Device Items configuration.
To export device items
1. Right-click anywhere in the Device Items dialog box.
Library control API:VB.NET PDF Text Extract Library: extract text content from PDF
Extract highlighted text out of PDF document. Image text extraction control provides text extraction from PDF images and image files.
www.rasteredge.com
Library control API:C# PDF Text Extract Library: extract text content from PDF file in
Image text extraction control provides text extraction from PDF images and image files. Enable extracting PDF text to another PDF file, TXT and SVG formats.
www.rasteredge.com
Configuration
65
MBTCP DAServer User’s Guide
2. Select the Export command from the shortcut menu.
The standard Save As dialog box appears.
The file name has defaulted into "PLC Hierarchyname.csv," within 
the current-system-configured default directory.
3. Accept the defaults to save the file.
The file is saved as New_<PLC Name>_000.csv.
It is editable in Microsoft Excel.
However, if you prefer to save the list someplace else and rename it, perform 
the following steps after step 2.
4. Select the folder into which the list is to be saved.
5. Name the list to be archived.
6. Click the Save button.
The whole list will be saved as a .csv file in Excel.
The file can now be edited off-line. It contains one row for each item 
configured with two columns, Name and Item Reference, respectively.
Library control API:VB.NET PDF insert image library: insert images into PDF in vb.net
VB.NET code to add an image to the inputFilePath As String = Program.RootPath + "\\" 1.pdf" Dim doc New PDFDocument(inputFilePath) ' Get a text manager from
www.rasteredge.com
Library control API:C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
NET. .NET library to batch convert PDF files to jpg image files. High quality jpeg file can be exported from PDF in .NET framework.
www.rasteredge.com
66
Chapter 2
MBTCP DAServer User’s Guide
To import device items
1. To import the list, right-click anywhere in the Device Items dialog box.
2. Select the Import command from the shortcut menu.
3. Select the archived list (.csv file) to be imported from the folder in which 
it is saved.
4. Click the Open button.
The whole list will be brought into the Device Items dialog box.
Note  When the list to be imported contains duplicate names as found in the 
current list but the Item References are different, a dialog box will appear to 
prompt you to make a selection.
To import device item data that has been edited off-line
1. Right-click anywhere in the Device Items dialog box.
2. Clear all the item data you wish to replace with the edited .csv file by 
selecting the Clear All command.
The data will be cleared after you click on Yes to confirm the deletion.
3. Select the Import command from the shortcut menu.
The standard Open dialog box appears.
It defaults to the .csv file extension within the current-system-
configured default directory.
4. Browse for the specific CSV file you want to import, select it, then click 
on the Open button.
The DAServer Manager will import the edited file and deposit it in 
the Device Items dialog box.
Configuration
67
MBTCP DAServer User’s Guide
During the imported file processing:
New item references will be added based on unique names.
If there are duplicate names, you will be provided with the option 
to replace the existing entry with the new entry, or ignore the new 
entry.
Scan-Based Message Handling
Wonderware's DAServers are based on the concept of polling a hardware 
device for information. This polling is driven by a need which is expressed in 
the form of requests from one or more clients. Once a particular piece of 
information has been requested by a client, the DAServer formulates its own 
request and sends that request to the hardware device. The DAServer then 
waits for a response to its request. Once the information has been received, the 
DAServer passes that information back to the client, and repeats the process 
until all clients have ceased requesting information.
The rate at which the DAServer will poll a particular device for a specific piece 
of information is defined in the device group (topic definition) inside the 
DAServer, using a parameter called the Update Interval. When setting this 
parameter, there is always a trade-off between the update speed of the device 
group and the resulting decrease in system responsiveness.
Since you more than likely want very fast response, the temptation is to set the 
Update Interval to a value close to 0 (zero) seconds. However, if every point is 
polled at this rate, the entire system will suffer due to slow response time. 
Therefore, you should compromise, and set the Update Interval to a more 
reasonable value. You could also create multiple device groups for each 
device, setting the Update Interval to different values, then assigning different 
items to different device groups depending on how quickly the values change 
and how quickly you want to see an update of those changes.
68
Chapter 2
MBTCP DAServer User’s Guide
Some items, like alarms, change very infrequently but because of their 
importance require very fast updates. For those kinds of items, you should set 
the Update Interval at a very small value. If you desire an immediate response, 
set the Update Interval at 1 (one).
Unsolicited Message Handling
In the world of PLCs and DAServers, it is obvious that a PLC will know when 
a critical event has occurred before the DAServer will have a chance to poll for 
that data. Therefore, it would seem natural that if a critical event occurs, the 
PLC should have the capability to inform the DAServer immediately, without 
having to wait for the DAServer to poll it.
This is the role of an unsolicited message. Once a PLC has determined that a 
critical condition (such as an alarm event) exists, it can generate a message that 
is immediately sent to the DAServer without a prior request from the 
DAServer. Compared to polling the PLC for an irregular event at fixed 
intervals, sending unsolicited messages from the PLC to the DAServer when 
the event occurs will not only cut down the network traffic, but may also get 
the data to the server more promptly.
Note  The unsolicited messaging feature is available only to controllers that 
are directly connected to the TCPIP_PORT. Controllers under the 
ModbusBridge Object hierarchy cannot utilize this feature.
In accordance with the protocol, the receiver of unsolicited messages must 
acknowledge the receipt of unsolicited messages.
Note  For the step-by-step procedure on how to configure the DAServer to 
receive unsolicited messages, see Device Group Definitions.
Archiving Configuration Sets
After your DAServer has been configured, you can archive that specific 
configuration. You can archive more than one configuration set, and 
subsequently choose different configurations for different purposes.
To archive configuration sets
1. In the DAServer Manager, right-click on the Configuration node in the 
hierarchy below your DAServer.
2. Select Archive Configuration Set from the shortcut menu.
3. In the Archive Configuration Set configuration view, provide a 
Configuration Set Name.
4. Click Archive.
All current configuration values are saved to the archived set.
Once you have archived at least one configuration set, you can select it for use.
To use different configuration sets from the current one
1. Make sure the DAServer is not running.
Configuration
69
MBTCP DAServer User’s Guide
2. In the DAServer Manager, right-click the Configuration node in the 
hierarchy below your DAServer.
3. Select Use Another Configuration Set from the shortcut menu and click 
on a configuration set in the sub-menu.
All parameters in the DAServer configuration hierarchy change to the 
chosen configuration set.
Hot Configuration
If a parameter value change takes effect right away while the DAServer is 
running, the parameter is a hot-configurable parameter. Certain parameters in 
the MBTCP DAServer are hot-configurable. Incorporated in the DAServer are 
the following hot-configuration functionalities:
• 
Modifying Global Configuration parameters.
• 
Adding, deleting, or modifying device nodes (without affecting any other 
device nodes, excluding the children of the modified device nodes).
• 
Adding, deleting, or modifying device groups in the Name and Update 
Interval columns in the Device Groups tab.
• 
Adding, deleting, or modifying Name and Item Reference in the Device 
Items tab.
Limited support is provided for the hot configuration for the server-specific 
configuration parameters in this release. You can modify server-specific 
parameters while the server is active. However, to have those changes take 
effect, you have to restart the DAServer.
The following parameters are hot configurable. They can be modified online 
and changes will take affect without restarting the DAServer.
• 
Reply timeout
• 
String variable style
• 
Register type
Note  If changes are made to server-specific parameters while the server is 
active, the DAServer will issue a warning message to the logger.
70
Chapter 2
MBTCP DAServer User’s Guide
Documents you may be interested