mvc return pdf : Convert pdf to text online control application system web page html wpf console module%205%20-%20multi-sheet%20design0-part1458

Module 5: Multi-Sheet Design 
Convert pdf to text online - control application system:C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net, ASP.NET MVC, WinForms, WPF application
C# PDF to Text (TXT) Converting Library to Convert PDF to Text
www.rasteredge.com
Convert pdf to text online - control application system:VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net, ASP.NET MVC, WinForms, WPF application
VB.NET Guide and Sample Codes to Convert PDF to Text in .NET Project
www.rasteredge.com
Module 5: Multi-Sheet Design 
5.1  Multi-Sheet Design...........................................................................5-1 
5.1.1
Structuring a multi-sheet design.....................................................................5-1
5.1.2
Multi-sheet design connectivity......................................................................5-2
5.1.3
Constructing the top sheet.............................................................................5-3
5.1.4
Assigning the sheet numbers and total number of sheets.............................5-6
5.1.5
Checking sheet symbol to sub-sheet synchronization...................................5-7
Software, documentation and related materials:  
Copyright © 2009 Altium Limited. 
All rights reserved. You are permitted to print this document provided that (1) the use of such is for personal use only and will 
not be copied or posted on any network computer or broadcast in any media, and (2) no modifications of the document is 
made. Unauthorized duplication, in whole or part, of this document by any means, mechanical or electronic, including 
translation into another language, except for brief excerpts in published reviews, is prohibited without the express written 
permission of Altium Limited. Unauthorized duplication of this work may also be prohibited by local statute. Violators may be 
subject to both criminal and civil penalties, including fines and/or imprisonment. Altium, Altium Designer, Board Insight, Design 
Explorer, DXP, LiveDesign, NanoBoard, NanoTalk, P-CAD, SimCode, Situs, TASKING, and Topological Autorouting and their 
respective logos are trademarks or registered trademarks of Altium Limited or its subsidiaries. All other registered or 
unregistered trademarks referenced herein are the property of their respective owners and no trademark rights to the same are 
claimed. 
Module Seq = 5 
control application system:Online Convert PDF to Text file. Best free online PDF txt
Online PDF to Text Converter. Download Free Trial. Convert a PDF to Text. Just upload your file by clicking on the blue button or drag
www.rasteredge.com
control application system:VB.NET PDF - Convert PDF Online with VB.NET HTML5 PDF Viewer
PDF to Jpeg, C# compress PDF, C# print PDF, C# merge PDF files, C# view PDF online, C# convert PDF to tiff, C# read PDF, C# convert PDF to text, C# extract PDF
www.rasteredge.com
5.1  Multi-Sheet Design 
5.1.1  Structuring a multi-sheet design  
All but the smallest designs will need to be laid out over multiple schematic sheets. There are 
essentially two approaches to structuring a multi-sheet design, either flat, or hierarchical. A flat 
design is one where the connectivity between nets that span sheets is directly from one sheet to 
the other or potential to many others. 
While a flat design is acceptable for a design with a small number of sheets and nets, perhaps 6 
sheets, it becomes unwieldy when the design is larger. Since a net can go to any of the other 
sheets, a larger flat design needs navigation instructions to guide the reader as they attempt to 
find that net on the other sheets. The advantage of the flat design is that there are normally 
fewer sheets, and less wiring to draw. 
A hierarchical design is one where the structure – or sheet-to-sheet relationships – in the design 
is represented. This is done by symbols, known as sheet symbols, which represent lower sheets 
in the design hierarchy. The symbol represents the sheet below, and the sheet entries in it 
represent (or connect to) the ports on the sheet below. The advantage of the hierarchical design 
is that it shows the reader the structure of design, and that the connectivity is completely 
predicable and easily traced, since it is always from the child sheet up to the sheet symbol on the 
parent sheet. 
The diagram below shows the top sheet for the Temperature Sensor project. Each sheet symbol 
represents a child schematic in the design.  
Figure 1. Temperature Sensor top sheet 
Module 5: Multi-sheet Design 
5
control application system:C# HTML5 PDF Viewer SDK to convert and export PDF document to
PDF to Jpeg, C# compress PDF, C# print PDF, C# merge PDF files, C# view PDF online, C# convert PDF to tiff, C# read PDF, C# convert PDF to text, C# extract PDF
www.rasteredge.com
control application system:VB.NET PDF Text Extract Library: extract text content from PDF
Best VB.NET PDF text extraction SDK library and component for free download. Online Visual Basic .NET class source code for quick evaluation.
www.rasteredge.com
5.1.2  Multi-sheet design connectivity 
Multi-sheet designs are also defined at the electrical (or connective) level by net identifiers which 
provide the ‘glue’ between nets in schematic sheets. 
5.1.2.1  Net identifiers 
Net identifiers create logical connections between points in the same net. This can be within a 
sheet, or across multiple sheets. Physical connections exist when one object is attached directly 
to another electrical object by a wire.  Logical connections are created when 2 net identifiers of 
the same type (eg, two net labels) have the same Net property. Note that logical connections are 
not created between different net identifiers, for example a port and a net label. The only 
exception to this is when a port connects to a sheet entry of the same name, in the sheet symbol 
that represents the sheet the port is on (more on this later). 
Net identifiers include:  
•  Net Label – Use a net label to uniquely identify a net. This net will connect to other nets of 
the same name on the same sheet, and can also connect to nets of the same name on 
different sheets, depending on the connectivity mode defined for the design (referred to as 
the net identifier scope). Net labels are attached to individual wires, part pins and buses. 
•  Port – Depending on the method of connectivity, a port can connect horizontally to other 
ports with the same name, or vertically to a sheet entry with the same name. 
•  Sheet Entry – When the connectivity is vertical, 
you can use a sheet entry to connect to a port of 
the same name on the sheet below. A sheet entry 
is added to a sheet using the Place » Add Sheet 
Entry command.  
sheet
entries
power
r
port
net label
port
t
Figure 2. Net identifiers 
ENABLE
RESET
VCC
RESET
ENABLE
•  Power Port – All power ports with the same 
name are connected throughout the entire design. 
•  Hidden Pin – Hidden pins behave like power 
ports, connecting globally to nets of the same name throughout the entire design. 
5.1.2.2  Net identifier scope 
When you create a connective model of a design, you must define how you want these net 
identifiers to connect to each other – this is known as setting the Net Identifier Scope. The scope 
of net identifiers is specified in the Options tab of the Project Options dialog. The scope of net 
identifiers should be determined at the beginning of the design process. 
Figure 3. Net identifier scope and netlist options 
Module 5: Multi-sheet Design 
5
control application system:C# PDF Text Extract Library: extract text content from PDF file in
Free online source code for extracting text from adobe PDF document in C#.NET class. Able to extract and get all and partial text content from PDF file.
www.rasteredge.com
control application system:C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
PDF to Jpeg, C# compress PDF, C# print PDF, C# merge PDF files, C# view PDF online, C# convert PDF to tiff, C# read PDF, C# convert PDF to text, C# extract PDF
www.rasteredge.com
There are essentially two ways of connecting sheets in a multi-sheet design: either horizontally, 
directly from one sheet, to another sheet, to another sheet, and so on; or vertically, from a sub-
sheet to the sheet symbol that represents it on the parent sheet. In horizontal connectivity, the 
connections are from port to port (net label to net label is also available). In vertical connectivity, 
the connections are from sheet entry to port.  
The Net Identifier Scope specifies how you want the net identifiers to connect:  
•  flat – ports connect globally across all sheets throughout the design. With this option, net 
labels are local to each sheet; they will not connect across sheets. All ports with the same 
name will be connected, on all sheets. This option can be used for flat multi-sheet designs. It 
is not recommended for large designs as it can be difficult to trace a net through the sheets. 
•  global – ports and net labels connect across all sheets throughout the design. With this 
option, all nets with the same net label will be connected together, on all sheets. Also, all 
ports with the same name will be connected, on all sheets. If a net connected to a port also 
has a net label, its net name will be the name of the net label.  This option can also be used 
for flat multi-sheet designs, however it is difficult to trace from one sheet to another, since 
visually locating net names on the schematic is not always easy.  
•  hierarchical (sheet entry/port connections) – connect vertically between a port and the 
matching sheet entry. This option makes inter-sheet connections only through sheet symbol 
entries and matching sub-sheet ports. It uses ports on sheets to take nets or buses up to 
sheet entries in corresponding sheet symbols on the top sheet. Ports without a matching 
sheet entry will not be connected, even if a port with the same name exits on another sheet. 
Net labels are local to each sheet; they will not connect across sheets. This option can be 
used to create designs of any depth or hierarchy and allows a net to be traced throughout a 
design on the printed schematic. 
•  The automatic mode automatically selects which of the three net identifier modes to use, 
based on the following criteria: if there are sheet entries on the top sheet, then Hierarchical is 
used; if there are no sheet entries, but there are ports present, then Flat is used; if there are 
no sheet entries and no ports, then Global is used. 
Note: Two special net identifier objects are always deemed to be global: power ports and 
hidden pins. 
Summary 
•  If you are using sheet symbols with sheet entries, the net identifier scope should be set to 
Sheet Entries/Port Connections. If this mode is chosen, the top sheet must be wired. 
•  If you are not, connectivity can be established via Ports and/or Net labels, so you will use one 
of the other two net identifier scopes. 
•  Net labels do not connect to ports of the same name. 
5.1.3  Constructing the top sheet 
The process of creating a top sheet can be done in a manual fashion, where the sheet symbols 
are placed, the filename attribute for each is set to point to the correct sub-sheet and the sheet 
entries are added to correspond to each port on the sub-sheet. 
There are also commands to speed the process of creating a multi-sheet design.  
The Create Sheet from Symbol command is for top-down design. Once the top sheet is fully 
defined, this command creates the sub-sheet for the chosen sheet symbol and places matching 
ports on it.  
The Create Symbol from Sheet command is for bottom-up design, creating a sheet symbol with 
sheet entries based on the chosen sub-sheet. This is the mode we will use now. 
Module 5: Multi-sheet Design 
5
control application system:VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.
from RTF. Create PDF from Text. PDF Export. Convert PDF to Word (.docx). Convert PDF to Tiff. Convert PDF to HTML. Convert PDF
www.rasteredge.com
control application system:C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
NET library to batch convert PDF files to jpg image files. Turn multiple pages PDF into single jpg files respectively online.
www.rasteredge.com
5.1.3.1  Exercise – creating the top sheet  
for the Temperature Sensor project 
Refer to Figure 1 to complete this exercise. 
1.  To create the top sheet, add a new schematic document to the Temperature Sensor project, 
set the template to A4 and save it as \Program Files\Altium Designer Summer 
09\Training\PCB Training\Temperature Sensor\Temperature 
Sensor.SchDoc. 
2.  Rather than manually placing sheet symbols and editing them to reference the lower sheets, 
we will use the Design » Create Sheet Symbol from Sheet or HDL command. Select this 
command from the menus. 
3.  In the Choose Document to Place dialog, select Sensor.SchDoc. 
4.  The sheet symbol will appear floating on the cursor. Place the sheet symbol in an 
appropriate position on the sheet, as shown in 
Figure 1
5.  Another important point about sheet entries, their I/O type is an independent attribute from 
their style (the direction they point), unless you have the auto Sheet Entry Direction option 
enabled in the Schematic tab of the Preferences dialog. The SCL sheet entry was pointing 
inward when it was on the left, now that it is on the right it will be pointing out if the Sheet 
Entry Direction option is currently disabled. Open the Preferences dialog and confirm that 
the option is enabled. 
6.  Repeat this process of creating symbols for the MCU, LCD and Power sub-sheets.  As you 
place each sheet symbol, you will notice that the sheet entries will appear on both sides of 
the symbol, depending on their I/O type: Inputs and Bidirectionals on the left, Outputs on the 
right.  Drag the sheet entries onto the correct sides of each symbol, according to Figure 1. 
Note: Sheets with no ports and even blank sheets if they are to be included in the hierarchy 
require having a sheet symbol created; otherwise the compile process fails to see these 
sheets. 
7.  Place the connector. It is a Header 3X2A, which can be found in the Miscellaneous 
Connectors.IntLib (one of the two integrated libraries installed by default). 
8.  Enable the Place Sheet Entries Automatically option in the Schematic – Graphical 
Editing page of the Preferences dialog. Use this feature to automatically place the sheet 
entries on the sensor schematic sheet symbol. 
Module 5: Multi-sheet Design 
5
Figure 4. Sheet entries can be placed automatically  
9.  Wire the top sheet as shown in 
Figure 1
10. Save the top sheet. 
This completes the capture phase of the design process. To confirm that the project 
hierarchy is correct we will now compile the design. This is covered in detail in section 
Module 6 – Building the Project, for now we will simply compile to show the correct structure 
of the design in the Projects panel. 
Figure 5. The project hierarchy is displayed once 
the project has been compiled. 
11. To compile the project, select 
Project » Compile PCB Project 
Temperature Sensor.PrjPcb, or 
you can run the shortcut CC. Make 
sure you run the correct compile 
command, as there are two in the 
Project menu. One compiles the 
current schematic document, the 
other compiles the whole project. 
We want to compile the project. 
12. Save the Project (right-click on the 
project in the Projects panel) 
The design is now complete. However, 
before it can be transferred to PCB 
layout there are a few other tasks to 
complete, these include: 
•  Assigning the sheet numbers for 
each sheet in the hierarchy 
•  Assigning the designators 
•  Checking the design for errors 
Module 5: Multi-sheet Design 
5
5.1.4  Assigning the sheet numbers and total number of sheets 
Sheet numbering is performed using documents parameters, linked to special strings placed on 
the schematics, as described earlier in Module 4 - Schematic Capture. Sheets can be 
automatically numbered by selecting the Tools » Number Schematic Sheets command. 
•  The Sheet Numbering dialog can be used to  
 number the sheets (SheetNumber parameter),  
 set the document number (DocumentNumber parameter),  
 set the total number of sheets (SheetTotal parameter).  
•  Click in the column to be edited to access the commands to edit that column. 
•  The sheets and documents can be numbered in a variety of ways, to do this click in the 
SheetNumber column, then click the Auto Sheet Number button. 
•  Cells can be edited manually, select the target cell(s), then right-click and select edit (or 
press the 
SPACEBAR
). Alternatively, use the Move Up and Move down buttons, the number 
the sheets based on the Display Order. 
Figure 6. Use the Sheet Numbering feature to review and update sheet numbers. 
Note: Schematics appear in the Projects panel in the order they were added to the project. 
You can change this order if you want, simply click, drag and drop to re-order them within the 
Projects Panel. 
5.1.4.1  Exercise – Number the sheets 
1.  Select the Tools » Number Schematic Sheets command in the schematic editor. 
2.  Sort the order of the schematics to match that of Figure 6 using the Move up and Move 
down buttons. 
3.  Press the buttons Auto Sheet Number, Auto Document Number and Update Sheet 
Count. 
4.  Press OK to save the changes. 
Note: Remember that these values are presented on the schematic sheets using parameters 
and matching special text strings. To display the values instead of the strings, enable the 
Convert Special Strings option in the Schematic – Graphical Editing page of the 
Preferences dialog. 
Module 5: Multi-sheet Design 
5
5.1.5  Checking sheet symbol to sub-sheet synchronization 
Typically the design hierarchy is not developed in a purely top-down or bottom-up fashion, the 
reality is that the design will evolve. This means that there will be modifications to the design that 
affect the net connectivity established between the sheet entries in the sheet symbol and the 
ports on the sub sheet below. 
To manage the sheet entry to port relationships, use the Synchronize Ports to Sheet Entries 
dialog. Select Design » Synchronize Sheet Entries and Ports to display the dialog. 
Figure 7. Use the Synchronize dialog to ensure that sheet entries match with ports. Uncheck the checkbox 
down the bottom left to show all sub-sheets in the entire design. 
The Synchronize dialog can be used to: 
•  Match any selected Entry to any selected Port (name and IO type will be changed). 
•  Add or remove Entries or Ports to either the sheet symbol or the sub sheet. 
•  Edit the name or IO direction of a matched Entry / Port (done in the Links column on the 
right). 
Note: Remember that changes made in the Synchronize Ports to Sheet Entries dialog are 
performed immediately; use the Undo command on each affected sheet to undo any updates. 
Module 5: Multi-sheet Design 
5
5.1.5.1  Exercise – Synchronize the sheet entries and Ports 
1.  From any schematic in the temperature sensor project, run the command Design » 
Synchronize Sheet Entries and Ports. 
2.  You may see a problem like the one shown in 
, where the I/O direction of the sheet 
entry (Input) does not match the I/O direction of the port (Output). You may also see a 
problem with the 3 sheet entries on the sensor sheet symbol, not having matching ports on 
the sensor schematic. Both of these can be resolved in the Synchronize Ports to Sheet 
Entries dialog.  
Figure 7
3.  To resolve the first problem, we need to determine which direction is correct. Once the 
correct direction has been determined, select each entry in the columns on the left, and then 
click on the 
to drive the sheet entry direction onto the port, or click on 
to 
drive the port direction onto the sheet entry. 
4.  The second problem is that the sheet entries exist, but they have no matching ports. Select 
all 3 sheet entries as shown in Figure 8, once you do you will have the option of either 
deleting the sheet entries, or adding ports. Click Add Ports, when you do the dialog will 
temporarily disappear, the Sensor schematic will become active, and the cursor will have 3 
ports on it. Place them anywhere for now, then close the dialog and return to the Sensor 
schematic and correctly position the ports onto their wires.  
5.  Save your design. 
Figure 8. Problems found - missing ports on a sheet 
Module 5: Multi-sheet Design 
5
Documents you may be interested
Documents you may be interested