PV Module 
169 
Current Coefficient [mA/k] 
This value shows by how many amps the current increases when the module temperature 
rises. The higher the module temperature, the higher the current, ie this coefficient is 
positive. 
Power Output Coefficient [%] 
The hotter the module, the lower the power output. This coefficient is negative and is 
proportional to the nominal output. 
Incident Angle Modifier [%] 
The incident angle modifier is a characteristic of the material covering the module (glass). 
The glass reflects part of the radiation away from the module resulting in a loss of current. 
The incident angle modifier reduces the amount of direct radiation falling onto the module. 
The correction factor for diffuse radiation lost through reflection is assumed at 95%. 
Maximum Module System Voltage[V] 
Each electrical appliance has a maximum voltage limit. This value refers to the maximum 
voltage that a array can support in order to ensure that no damage is caused to the 
modules. If the maximum voltage is too high, you should reduce the number of modules in 
series. 
Specifications for the Dynamic Temperature Model: 
Heat Capacity [J/(kg*K)], Absorption Coefficient [%], Emissions Coefficient [%], Weight 
[kg] 
These are the parameters for the dynamic temperature model required for working out the 
thermal balance equation. 
Click on Load to load one of the module files provided, to check on the values and correct 
if required. 
Click on Save to save the values you have entered, either in the current file or as a new file. 
A message appears before a file is overwritten. 
Close exits the dialog without a message appearing. 
If you want to print out the file that has been loaded last click on Print. This will be printed 
on the standard printer as specified in printer set-up. 
Convert scanned pdf to text online - SDK application API:C# PDF Convert to Text SDK: Convert PDF to txt files in C#.net, ASP.NET MVC, WinForms, WPF application
C# PDF to Text (TXT) Converting Library to Convert PDF to Text
www.rasteredge.com
Convert scanned pdf to text online - SDK application API:VB.NET PDF Convert to Text SDK: Convert PDF to txt files in vb.net, ASP.NET MVC, WinForms, WPF application
VB.NET Guide and Sample Codes to Convert PDF to Text in .NET Project
www.rasteredge.com
170 
13.2.2 Module Part Load Operation 
The module’s operation under part load conditions is calculated from the specifications for 
no-load voltage, short circuit current, MPP voltage and MPP current with low irradiation 
and a module temperature of 25°C. 
The second working point, ie the choice of irradiation level, has to be set under certain 
restrictions. It must be selected so that, at the irradiation point set, the fill factor is at 
maximum, or so that, with lower irradiation, the fill factor becomes considerably smaller 
and with higher irradiation the fill factor is around the maximum value. 
The definition of the fill factor is: 
FF = (MPP current * MPP voltage) 
/ (short circuit current * no-load voltage) 
The fill factor (FF) is dependent on the irradiation. If a FF above the irradiation is applied, 
this results in the fill factor function. Depending on the module and the irradiation, the FF 
is usually set at around 55% and 85%. 
If you don’t have any suitable specifications for part load operation, you can run the 
calculation with standard values by clicking on the Typical Part Load Operation button. 
For most modules, the irradiation at the fill factor maximum is 300 W/m². The fill factor is 
set at 5% above the FF under standard test conditions. Linear part load operation is given 
for the current. 
After you have entered the values for module part load operation, it is essential to take a 
look at the efficiency characteristic curve and to test that there are no discrepancies. 
SDK application API:C# PDF - Extract Text from Scanned PDF Using OCR SDK
NET convert PDF to text, C#.NET convert PDF to images Recognize scanned PDF document and output OCR result to MS C# class source code for ocr text extraction in
www.rasteredge.com
SDK application API:VB.NET PDF Text Extract Library: extract text content from PDF
OCR text from scanned PDF by working with XImage.OCR SDK. Best VB.NET PDF text extraction SDK library and component for free download. Online Visual Basic .NET
www.rasteredge.com
171 
13.2.3 Inverter – Grid Connected Systems 
The characteristics for the inverter are entered in this window. Details on using the 
database are given under Project Design. 
If you want to enter an inverter that can be switched to different voltage levels, you will 
have to enter the individual voltage fields as separate inverters with the characteristic 
data for each of these. 
As in all database dialogs there are the Load, Save and Close buttons and there is also a 
Print button. 
Manufacturer and Type are allowed a maximum text length of 50 characters. 
DC Power Rating [kW] 
DC stands for direct current and refers to the input side of the inverter. As this value is not 
clearly defined by inverter manufacturers, it is no longer used in PV*SOL and is shown for 
information only. 
Max. DC Power [kW] 
This value is also not clearly defined by inverter manufacturers. It is no longer used in 
PV*SOL and is shown for information only. 
AC Power Rating [kW] 
AC stands for alternating current and refers to the output side of the inverter. The AC power 
rating is the output that the inverter is designed for when in continuous operation.  When 
the inverter is in continuous operation the power output is limited, with the AC power 
rating being the upper limit. 
Max. AC Power [kW] 
The output that the inverter can produce in 10 minutes. This value is not currently used in 
PV*SOL. 
Stand-by Consumption [W] 
If no energy is being delivered into the grid or to the electrical appliances, the energy 
required by the inverter itself still has to be accounted for. In addition to the stand-by 
consumption there is also night consumption. 
Night Consumption [W] 
The inverter switches itself off during the night, but still uses a small amount of energy. 
Input Level [W] 
The minimum amount of energy to be produced by the PV generator before the inverter can 
function. 
Nominal DC Voltage[V] / Nominal DC Current [A] 
SDK application API:C# PDF Text Extract Library: extract text content from PDF file in
Free online source code for extracting text from adobe PDF document in C#.NET class. Supports text extraction from scanned PDF by using XDoc.PDF for .NET
www.rasteredge.com
SDK application API:C# TIFF: How to Convert TIFF File to PDF Document in C# Project
Convert Tiff to Scanned PDF. |. Home ›› XDoc.Tiff ›› C# Tiff: Tiff to PDF.
www.rasteredge.com
PV*SOL Expert 6.0  -  Manual  
172 
The input voltage or the input current of the inverter, when delivering nominal power 
output. 
Number of MPP Trackers 
The number of independently operating MPP regulators. 
For multi-string appliances, this value is greater than 1. 
Max. Input Current per MPP Tracker [A] 
This current limit per MPP tracker should not be exceeded. (Only active if the number of 
MPP trackers is greater than 1.) 
Max. Recommended PV Output per MPP Tracker[kW] 
See Max. Recommended PV Output [kW] 
Maximum Input Voltage [V] / Maximum Input Current [A] 
This level of voltage or current should not be exceeded, otherwise the inverter will be 
damaged. 
Upper and Lower Voltage Levels for the MPP Range [V] 
Within this voltage range, the inverter is able to control the MPP tracking. The inverter 
finds the optimal voltage for the PV generator within this range, so that the generator’s 
power output is maximized. 
MPP Adjustment Efficiency [%] 
The adjustment efficiency provides a measurement of how close the inverter’s working 
point is to the PV generator’s maximum power point (MPP). The programme differentiates 
between the power ranges <20% and >20% of the nominal output. The adjustment 
efficiencies are taken into account during simulation in defining the inverter’s 
performance ratio. 
Characteristic Curve - Inverter 
This button opens the Characteristic Curve – Inverter dialog, so that the you can enter the 
conversion efficiency depending on the input power. These values should be obtained 
from the inverter manufacturer. 
The European efficiency is calculated with the following formula: 
Wg(EU) = 0.03*Wg(5%) + 0.06*Wg(10%) + 0.13*Wg(20%) + 0.1*Wg(30%)+ 
0.48*Wg(50%) + 0.2*Wg(100%) 
Deviation of the Input Voltage from the Nominal Voltage 
The inverter’s efficiency characteristic curve is entered for the nominal voltage. If the 
inverter is not operated at its nominal voltage, there is a change in the efficiency of the 
inverter. Whether the efficiency increases or decreases is dependent on whether the 
inverter has a transformer, or not. The following can be used as a rule of thumb: 
SDK application API:VB.NET PDF Convert to Word SDK: Convert PDF to Word library in vb.
high quality Word documents from both scanned PDF and searchable Convert PDF document to DOC and DOCX formats in to export Word from multiple PDF files in VB.
www.rasteredge.com
SDK application API:VB.NET PDF - Extract Text from Scanned PDF Using OCR SDK
VB.NET delete PDF pages, VB.NET convert PDF to SVG. page of PDF document and extract its text content. Recognize scanned PDF document and output OCR result to MS
www.rasteredge.com
Inverter Grid Connected Systems 
173 
• 
The efficiency of an inverter with a transformer reduces with rising input voltage 
by about 1% per 100 V. 
• 
The efficiency of an inverter without a transformer increases with rising input 
voltage by about 1% per 100V. 
Click on Load to load one of the inverter files provided, to check on the values and correct 
if required. 
Click on Save to save the values you have entered, either in the current file or as a new file. 
A message appears before a file is overwritten. 
Close exits the dialog without a message appearing. 
If you want to print out the file that has been loaded last click on Print. This will be printed 
on the standard printer as specified in printer set-up. 
-> See also: 
Inverter 
Inverter – Stand-Alone Systems 
SDK application API:VB.NET Create PDF from Word Library to convert docx, doc to PDF in
Export all Word text and image content into high Easy to create searchable and scanned PDF files from Word. Convert Word to PDF file with embedded fonts or
www.rasteredge.com
SDK application API:VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
PDF, VB.NET convert PDF to text, VB.NET Convert multiple pages PowerPoint to fillable and editable PDF Easy to create searchable and scanned PDF files from
www.rasteredge.com
174 
13.2.4 Inverter – Stand-Alone Systems 
The characteristics for a stand-alone system inverter are entered in this window. Details on 
using the database are given under Project Design. 
Manufacturer and Type are allowed a maximum text length of 50 characters. 
Nominal DC Output: 
The direct current flows into the inverter. The nominal output is the power rating at which 
the inverter, under continuous operation, is designed to run. 
Nominal AC Output: 
This refers to the current that flows out of the inverter. The nominal AC output is the power 
rating that is available for the electrical appliances connected to the system. 
Stand-by Consumption [W]: 
If no energy is being delivered into the grid or to the electrical appliances, the energy 
required by the inverter itself still has to be accounted for. 
Nominal DC Voltage: 
The nominal DC voltage must match the battery’s nominal voltage. 
Nominal AC voltage: 
The voltage corresponds to the nominal voltage of the appliances. 
Characteristic Curve - Inverter: 
This button opens the Characteristic Curve – Inverter dialog, so that the you can enter the 
conversion efficiency depending on the input power. These values should be obtained 
from the inverter manufacturer. 
-> See also: 
Inverter 
Inverter – Grid Connected Systems 
175 
13.2.5 Inverter Characteristic Curve dialog 
The conversion efficiency is the relationship of the power output to the power input, 
dependent on the inverter power at that time. 
The specification of the efficiency given in manufacturers’ data sheets relates to the 
nominal output (power rating), which PV systems, however, are not able to deliver at most 
times of the year. Therefore the part load operation is much more important for the 
simulation results. 
The programme requires 7 support points to define the characteristic curve, ie the 
efficiency at 0, 5, 10, 20, 30, 50 and 100% of the nominal output. 
To view the characteristic curve in graphic form, click on the Graph button. 
For grid connected systems, the European efficiency support points are fixed and 
displayed. If changes are made, these are first calculated on exiting the entry field. 
-> See also: 
Database: Inverter 
176 
13.2.6 Battery (not available with PV*SOL®-N for grid connected systems only) 
The following battery characteristics are entered in this dialog: 
Manufacturer and Type: 
You are allowed to enter a maximum of 50 characters. 
Voltage: 
The battery’s nominal voltage. 
C20 Capacity: Battery capacity with a discharge time of 20 hours. 
Capacity: 
The product of voltage and C20 capacity. This is calculated within the programme by 
clicking on Calculator. 
Self-Discharge: 
The details from the battery’s product data sheet should be recalculated to % per day. 
Average Charge and Discharge Efficiency: 
If you do not have these specifications to hand, please use the programme’s default 
values. 
Click on Load to load one of the battery files provided, to check on the values and correct if 
required. 
Click on Save or Save as… to save the values you have entered, either in the current file or 
as a new file. A message appears before a file is overwritten. 
Close exits the dialog without any message appearing. 
If you want to print out the values from the file that has been loaded last click on Print. The 
information will be printed on the standard printer as specified in printer set-up. 
177 
13.2.7 From Grid Tariff 
The tariff for electricity from the utility grid used by the electrical appliances is defined 
here. For more information on how to use the database see: Project Design. 
From the Load and Save File dialog and you are able to load a tariff file from the database 
or save a tariff file to the database [*.tar]. 
The tariff reference is given in the field labelled Name. 
High Tariff and Special Tariff Periods are defined in the Tariff Time Periods dialog. These 
times are valid for electricity drawn from the grid as well as for energy exported to the grid. 
The kilowatt-hour prices for each tariff time period (ie HT – high tariff, LT – low tariff and ST 
– special tariff) are entered in the Kilowatt-Hour Price dialog. 
Click on the Power Measurement button to define the type of power measurement (¼ hour 
power measurement, 96 hour measurement) In addition, the prices for the energy 
provided by the grid utility is defined here and the light or heavy load periods are entered. 
The grid utility discounts and supplements can be entered separately in the Discounts and 
Supplements dialog. 
178 
13.2.7.1  Tariff Time Periods 
The high tariff periods (HT) and any special tariff periods (ST) are defined here. These tariff 
periods are valid for the supply of energy both to and from the grid utility. 
Winter Time: From… To: 
Entry of the tariff period for winter is made in dd.mm format. . 
Different Tariff Periods – Summer/Winter: 
Select to enter separate tariff periods for summer and winter. 
• 
Define Special Tariff Periods: 
Select to create a new worksheet for the entry of a special tariff period in addition 
to high and low tariff periods. Separate kilowatt-hour rates can be entered for 
these times in the Kilowatt-Hour Price dialog. When a high tariff period is also 
defined as a special tariff period, this period is valid as a special tariff period. 
• 
New HT Periods Valid From: 
With the assistance of these selection fields you can define which days in the week 
different tariff periods are valid on. The first column shows on which days of the 
week the times entered are valid. 
High Tariff Periods: 
You can enter up to 5 time periods (from ... to ... hours) per day. Enter these values in time 
format. 