In the case of aggregated links, choose the aggregation mode that corresponds to the
switch settings from the Aggregation mode drop-down.
Note
Configuring link aggregation requires advanced knowledge of how to configure
network switches. Consult your network switch documentation before configuring
your cluster for link aggregation.
2. When you have finished assigning external network interfaces to the IP address pool,
click Submit.
The external subnet settings you configured by using the Subnet wizard appear on the
Edit Subnet page.
Managing external network subnets
You can configure subnets on an external network to manage connections between the
EMC Isilon cluster and client computers.
Modify external subnet settings
You can modify the subnet for the external network.
Note
Modifying an external network subnet that is in use can disable access to the cluster and
the web administration interface. OneFS displays a warning if deleting a subnet will
terminate communication between the cluster and the web administration interface.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet you want to
modify.
3. In the Settings area, click Edit.
4. Modify the Basic subnet settings as needed.
Options
Description
Description
A descriptive comment that can be up to 128 characters.
Netmask
The subnet mask for the network interface. This field appears
only for IPv4 subnets.
MTU
The maximum size of the transmission units the cluster uses in
network communication. Any numerical value is allowed, but
might not be compatible with your network. Common settings
are 1500 (standard frames) and 9000 (jumbo frames).
Gateway address s The IP address of the gateway server through which the cluster
communicates with systems outside of the subnet.
Gateway priority
The priority of the subnet's gateway for nodes that are assigned
to more than one subnet. Only one default gateway can be
configured on each Isilon node, but each subnet can have its
own gateway. If a node belongs to more than one subnet, this
option enables you to define the preferred default gateway. A
Networking
Managing external network subnets
361
Pdf to jpeg converter - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert .pdf to .jpg online; change pdf file to jpg
Pdf to jpeg converter - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
conversion of pdf to jpg; batch pdf to jpg converter
Options
Description
value of 1 is the highest priority, with 10 being the lowest
priority.
SmartConnect
service IP
The IP address that receives incoming DNS requests from
outside the cluster. SmartConnect responds to these DNS
requests for each IP address pool according to the pool's client-
connection policy. To use connection balance, at least one
subnet must be configured with a SmartConnect service IP
address.
5. Optional: Modify the Advanced settings as needed.
Note
Configuring a virtual LAN requires advanced knowledge of network switches. Consult
your network switch documentation before configuring your cluster for a VLAN. If you
are not using a virtual LAN, leave the VLAN options disabled.
Options
Description
VLAN tagging
You can enable VLAN tagging. VLAN tagging allows a cluster to
participate in multiple virtual networks. VLAN support provides
security across subnets that is otherwise available only by
purchasing additional network switches.
VLAN ID
If you enabled VLAN tagging, type a VLAN ID that corresponds to
the ID number for the VLAN that is set on the switch, with a value
from 1 to 4094.
Hardware load
balancing IPs
You can enter the IP address for a hardware load balancing switch
that uses Direct Server Return (DSR).
6. Click Submit.
Remove an external subnet
You can delete an external network subnet that you no longer need.
Deleting an external network subnet that is in use can prevent access to the cluster and
the web administration interface. OneFS displays a warning if deleting a subnet will
terminate communication between the cluster and the web administration interface.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet you want to
delete.
The Edit Subnet page appears for the subnet you specified.
3. Click Delete subnet.
A confirmation dialogue box appears.
4. Click Yes to delete the subnet.
If the subnet you are deleting is used to communicate with the web administration
interface, the confirmation message will contain an additional warning.
Networking
362
OneFS
7.1 
Web Administration Guide
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
change pdf to jpg format; conversion pdf to jpg
C#: How to Use SDK to Convert Document and Image Using XDoc.
You may use our converter SDK to easily convert PDF, Word, Excel, PowerPoint, Tiff, and Dicom files to raster images like Jpeg, Png, Bmp and Gif.
change from pdf to jpg on; change file from pdf to jpg on
Create a static route
You can create a static route to connect to networks that are unavailable through the
default routes.
You configure a static route on a per-pool basis. A static route can be configured only with
the command-line interface and only with the IPv4 protocol.
Procedure
1. Open a secure shell (SSH) connection to any node in the cluster and log in.
2. Create a static route by running the following command: 
isi networks modify
pool
--name 
<subnetname>
:
<poolname>
--add-static-routes 
<subnet>
/
<netmask>-<gateway>
The system displays output similar to the following example:
Modifying pool 'subnet0:pool0': Saving: 
OK                                                                 
OK
3. To verify that the static route was created, run the following command: 
isi networks
ls pools -v
.
Remove a static route
You can remove static routes.
Procedure
1. Open a secure shell (SSH) connection to any node in the cluster and log in.
2. Remove a static route by running the following command: 
isi networks modify
pool
--name 
<subnetname>
:
<poolname>
--remove-static-routes 
<subnet>
/
<netmask>-<gateway>
The system displays output similar to the following example:
Modifying pool 'subnet0:pool0':
Saving:                                                            
OK
3. To ensure that the static route was created, run the following command: 
isi
networks ls pools -v
.
Enable or disable VLAN tagging
You can configure a cluster to participate in multiple virtual private networks, also known
as virtual LANs or VLANs. You can also configure a VLAN when creating a subnet using the
Subnet wizard.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet that contains the
IP address pool that you want to add interface members to.
3. In the Settings area for the subnet, click Edit.
4. In the VLAN tagging list, select Enabled or Disabled.
If you select Enabled, proceed to the next step. If you select Disabled, proceed to Step
6.
5. In the VLAN ID field, type a number between 2 and 4094 that corresponds to the VLAN
ID number set on the switch.
Networking
Managing external network subnets
363
C# PDF Convert: How to Convert Jpeg, Png, Bmp, & Gif Raster Images
Jpeg, Png, Bmp, Gif Image to PDF. |. Home ›› XDoc.Converter ›› C# Converter: Raster Image to PDF.
convert pdf to high quality jpg; change pdf file to jpg file
Online Convert Jpeg to PDF file. Best free online export Jpg image
Online JPEG to PDF Converter. Download Free Trial. Convert a JPG to PDF. You can drag and drop your JPG file in the box, and then start
convert multiple pdf to jpg online; convert pdf picture to jpg
6. Click Submit.
Managing IP address pools
IP address pools allow you to manage the IP addresses clients use to connect to an EMC
Isilon cluster. You can also add network interfaces to IP address pools. Each IP address
pool is associated with a subnet.
Add an IP address pool
You can add an IP address pool to a external network subnet.
Procedure
1. Click Cluster Management
Network Configuration.
2. Click the name of the subnet to which you are adding an IP address pool.
3. In the IP Address Pools area, click Add pool.
4. Specify basic settings for the new IP address pool and click Next.
5. Optional: Specify SmartConnect settings and click Next.
6. Optional: Add network interface members and click Submit.
Modify an IP address pool
You can use the web interface to modify IP address pool settings.
Procedure
1. Click Cluster Management
Network Configuration.
2. Click the name of the subnet containing the pool you want to modify.
3. In the Basic Settings area, click Edit for the IP address pool you want to modify.
4. Modify the address pool settings and click Submit.
Delete an IP address pool
You can use the web interface to delete IP address pool settings.
Procedure
1. Click Cluster Management
Network Configuration.
2. Click the name of the subnet containing the pool you want to delete.
3. Click Delete pool by the pool you want to delete.
Modify a SmartConnect zone
You can modify the settings of a SmartConnect zone that you created for an external
network subnet using the Subnet wizard.
Procedure
1. Click Cluster Management
Network Configuration.
2. Click the name of the external network subnet that contains the SmartConnect zone
you want to modify.
3. In the SmartConnect settings area of the pool containing the SmartConnect settings
you want to modify, click Edit.
4. Modify the Zone name, and then click Submit.
The SmartConnect zone should be a fully-qualified domain name (FQDN).
Networking
364
OneFS
7.1 
Web Administration Guide
XDoc.Converter for .NET, Support Documents and Images Conversion
This .NET file converter SDK supports various commonly used document Office (2003 and 2007) Word, Excel, PowerPoint, PDF, Tiff, Dicom, SVG, Jpeg, Png, Bmp
convert pdf into jpg; changing pdf to jpg on
VB.NET PDF Converter Library SDK to convert PDF to other file
As this VB.NET PDF converter component plug-in embeds several image image converting applications, like PDF to tiff conversion, PDF to JPEG conversion and
convert pdf file into jpg format; .pdf to .jpg online
Disable a SmartConnect zone
You can remove a SmartConnect zone from an external network subnet.
Procedure
1. Click Cluster Management
Network Configuration.
2. Click the name of the external network subnet that contains the SmartConnect zone
you want to disable.
3. In the SmartConnect settings area for the pool containing the SmartConnect zone you
want to delete, click Edit.
4. To disable the SmartConnect zone, delete the name of the SmartConnect zone from
the Zone name field and leave the field blank.
5. Click Submit to disable the SmartConnect zone.
Configure IP failover
You can configure IP failover to reassign an IP address from an unavailable node to a
functional node, which enables clients to continue communicating with the cluster, even
after a node becomes unavailable.
Procedure
1. Click Cluster Management
Network Configuration
2. In the External Network Settings area, click the name of the subnet for which you
want to set up IP failover.
3. Expand the area of the pool you want to modify and click Edit in the SmartConnect
Settings area.
4. Optional: In the Zone name field, enter a name for the zone, using no more than 128
characters.
5. In the Connection Policy list, select a balancing policy:
Options
Description
Round Robin
Selects the next available node on a rotating basis, and is the
default state if no other policy is selected.
Connection Count
Determines the number of open TCP connections on each
available node to optimize the cluster usage.
Network Throughput t Uses the overall average throughput volume on each available
node to optimize the cluster usage.
CPU Usage
Examines average CPU utilization on each available node to
optimize the cluster usage.
6. If you purchased a license for SmartConnect Advanced, you will also have access to
the following lists:
IP allocation method
This setting determines how IP addresses are assigned to clients. Select either
Dynamic or Static.
Rebalance Policy
This setting defines the client redirection policy for when a node becomes
unavailable. The IP allocation list must be set to Dynamic in order for rebalance
policy options to be selected.
Networking
Managing IP address pools
365
C# PDF Converter Library SDK to convert PDF to other file formats
Help to convert PDF to multiple image formats, including GIF, BMP, JPEG, PNG and so on. Remarkably, this PDF document converter control for C#.NET can
change from pdf to jpg; batch convert pdf to jpg
C# Create PDF from images Library to convert Jpeg, png images to
NET converter control for It enables you to build a PDF file with one or more images. Various image forms are supported which include Png, Jpeg, Bmp, and Gif
pdf to jpeg converter; convert pdf to jpeg
IP failover policy
This setting defines the client redirection policy when an IP address becomes
unavailable.
Allocate IP addresses to accommodate new nodes
You can expand capacity by adding new nodes to your Isilon cluster.
After the hardware installation is complete, you can allocate IP addresses for a new node
on one of the cluster's existing external network subnets, and then add the node's
external interfaces to the subnet's IP address pool.
You can also use network provisioning rules to automate the process of configuring the
external network interfaces for new nodes when they are added to a cluster, although you
may still need to allocate more IP addresses for the new nodes, depending on how many
are already configured.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet that contains the
IP address pool that you want to allocate more IP addresses to in order to
accommodate the new nodes.
3. In the Basic settings area, click Edit.
4. Click New to add a new IP address range using the Low IP and High IP fields. or click
the respective value in either the Low IP or High IP columns and type a new beginning
or ending IP address.
5. Click Submit.
6. In the Pool members area, click Edit.
7. In the Available Interfaces table, select one or more interfaces for the newly added
node, and then click the right arrow button to move the interfaces into the Interfaces
in current pool table.
8. Click Submit to assign the new node interfaces to the IP address pool.
Managing network interface members
You can assign nodes and network interfaces to specific IP address pools.
You can also aggregate network interfaces and specify the aggregation method.
Modify the interface members of a subnet
You can use the web interface to modify interface member settings.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the subnet containing the interface
members you want to modify.
3. Click Edit next to the Pool members area.
Networking
366
OneFS
7.1 
Web Administration Guide
Remove interface members from an IP address pool
You can use the web interface to remove interface members from an IP address pool.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet containing the IP
address pool that you want to remove the interface member(s) for.
3. In the Pool members area, click Edit.
4. Remove a node's interface from the IP address pool by clicking the node's name in the
Interfaces in current pool column, and then click the left arrow button. You can also
drag and drop node interfaces between the Available Interfaces list and the Interfaces
in current poolcolumn.
5. When you have finished removing node interfaces from the IP address pool, click
Submit.
Configure NIC aggregation
You can configure cluster IP address pools to use NIC aggregation.
Before you begin
You must enable NIC aggregation on the cluster before you can enable NIC aggregation
on the switch. If the cluster is configured but the switch is not configured, then the cluster
can continue to communicate. If the switch is configured, but the cluster is not
configured, the cluster cannot communicate, and you are unable to configure the cluster
for NIC aggregation.
This procedure describes how to configure network interface card (NIC) aggregation for an
IP address pool belonging to an existing subnet. You can also configure NIC aggregation
while configuring an external network subnet using the Subnet wizard.
Configuring NIC aggregation means that multiple, physical external network interfaces on
a node are combined into a single logical interface. If a node has two external Gigabit
Ethernet interfaces, both will be aggregated. On a node with both Gigabit and 10 Gigabit
Ethernet interfaces, both types of interfaces can be aggregated, but only with interfaces
of the same type. NIC aggregation cannot be used with mixed interface types.
An external interface for a node cannot be used by an IP address pool in both an
aggregated configuration and an individual interface. You must remove the individual
interface for a node from the Interfaces in current pool table before configuring an
aggregated NIC. Otherwise, the web administration interface displays an error message
when you click Submit.
Note
Configuring link aggregation requires advanced knowledge of network switches. Consult
your network switch documentation before configuring your cluster for NIC aggregation.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet that contains the
IP address pool that you want to add aggregated interface members to.
3. In the Pool members area, click Edit.
In the case of multiple IP address pools, expand the pool that you want to add the
aggregated interfaces to, and then click Edit in the Pool members area.
Networking
Managing network interface members
367
4. In the Available interfaces table, click the aggregated interface for the node, which is
indicated by a listing of AGGREGATION in the Type column.
For example, if you want to aggregate the network interface card for Node 2 of the
cluster, click the interface named ext-agg, Node 2 under Available interfaces, and
then click the right-arrow button to move the aggregated interface to the Interfaces in
current pool table.
5. From the Aggregation mode drop-down, select the appropriate aggregation mode that
corresponds to the network switch settings.
Note
Consult your network switch documentation for supported NIC aggregation modes.
OneFS supports the following NIC aggregation modes:
Options
Description
Link Aggregation
Control Protocol
(LACP)
Supports the IEEE 802.3ad Link Aggregation Control
Protocol (LACP). This method is recommended for switches
that support LACP and is the default mode for new pools.
Legacy Fast
EtherChannel (FEC)
mode
This method is compatible with aggregated configurations
in earlier versions of OneFS.
Etherchannel (FEC)
This method is the newer implementation of the Legacy FEC
mode.
Active / Passive
Failover
This method transmits all data transmits through the master
port, which is the first port in the aggregated link. The next
active port in an aggregated link takes over if the master
port is unavailable.
Round-Robin Tx
This method balances outbound traffic across all active
ports in the aggregated link and accepts inbound traffic on
any port.
6. Click Submit.
NIC and LNI aggregation options
Network interface card (NIC) and logical network interface (LNI) mapping options can be
configured for aggregation.
The following list provides guidelines for interpreting the aggregation options.
u
Nodes support multiple network card configurations.
u
LNI numbering corresponds to the physical positioning of the NIC ports as found on
the back of the node. LNI mappings are numbered from left to right.
u
Aggregated LNIs are listed in the order in which they are aggregated at the time they
are created.
u
NIC names correspond to the network interface name as shown in command-line
interface tools such as ifconfig and netstat.
Networking
368
OneFS
7.1 
Web Administration Guide
LNI
NIC
Aggregated LNI
Aggregated NIC
Aggregated NIC
(Legacy FEC mode
-
-
-
-
-
ext-1
ext-2
em0
em1
ext-agg = ext-1 + ext-2
lagg0
fec0
ext-1
ext-2
ext-3
ext-4
em2
em3
em0
em1
ext-agg = ext-1 + ext-2
ext-agg-2 = ext-3 + ext-4
ext-agg-3 = ext-3 + ext-4 + ext-1 +
ext-2
lagg0
lagg1
lagg2
fec0
fec1
fec2
ext-1
ext-2
10gige-1
10gige-1
em0
em1
cxgb0
cxgb1
ext-agg = ext-1 + ext-2
10gige-agg-1 = 10gige-1 + 10gige-2
lagg0
lagg1
fec0
fec1
Remove an aggregated NIC from an IP address pool
You can remove an aggregated NIC configuration from an IP address pool if your network
environment has changed. However, you must first replace the aggregated setting with
single-NIC settings in order for the node to continue supporting network traffic.
Procedure
1. Click Cluster Management
Network Configuration.
2. In the External Network Settings area, click the name of the subnet that contains the
IP address pol with the NIC aggregation settings you want to remove.
3. In the Pool members area, click Edit.
4. Select the name of the aggregated NIC for the node that you want to remove in the
Interfaces in current pool table, and then click the left arrow button to move the name
into the Available interfaces table.
5. Select one or more individual interfaces for the node in the Available interfaces table,
and then click the right arrow button to move the interfaces into the Interfaces in
current pool table.
6. When you have completed modifying the node interface settings, click Submit.
Move nodes between IP address pools
You can move nodes between IP address pools in the event of a network reconfiguration
or installation of a new network switch.
The process of moving nodes between IP address pools involves creating a new IP
address pool and then assigning it to the nodes so that they are temporarily servicing
multiple subnets. After testing that the new IP address pool is working correctly, the old
IP address pool can safely be deleted.
Procedure
1. Create a new IP address pool with the interfaces belonging to the nodes you want to
move.
2. Verify that the new IP address pool functions properly by connecting to the nodes you
want to move with IP addresses from the new pool.
Networking
Managing network interface members
369
3. Delete the old IP address pool.
Reassign a node to another external subnet
You can move a node interface to a different subnet.
Nodes can be reassigned to other subnets.
Procedure
1. Click Cluster Management 
Network Configuration.
2. In the External Settings area, click the subnet containing the node that you want to
modify.
3. In the IP Address Pools area, click Edit next to the Pool members area.
4. Reassign the interface members that you want to move by dragging and dropping
them from one column to other, or by clicking on an interface member and using the
left arrow and right arrow buttons.
Configure DNS settings
You can configure the domain name servers (DNS) and DNS search list to resolve host
names for the EMC Isilon cluster.
Procedure
1. Click Cluster Management
Networking Configuration.
2. In the DNS Settingsarea, click Edit.
3. In the Domain name server(s) field, enter up to three domain name server IP
addresses. You can specify domain name server addresses in IPv4 or IPv6 format.
4. In the DNS search list field, enter up to six DNS search suffixes. DNS search suffixes
are appended to unqualified host names .
5. Optional: In the DNS resolver options field, enter advanced DNS configuration
variables.
Note
Setting DNS resolver options may change how OneFS performs DNS lookups. Do not
set DNS resolver options unless directed to do so by Isilon Technical Support.
6. Click Submit.
Managing external client connections with SmartConnect
You can manage settings that determine how IP addresses are allocated to client
connection requests.
With the Basic SmartConnect module, you can specify connection balancing and IP
allocation policies. If you have activated a Advanced SmartConnect license, you can also
specify settings that manage IP failover and rebalancing.
Configure client connection balancing
You can configure connection balancing for your cluster's external network connections
with SmartConnect.
Before you begin
You must first enable SmartConnect by setting up a SmartConnect service address on the
external network subnet that answers incoming DNS requests.
Networking
370
OneFS
7.1 
Web Administration Guide
Documents you may be interested
Documents you may be interested