Replace or renew the SSL certificate
You can replace or renew the Secure Sockets Layer (SSL) certificate, which is used to
access the EMC Isilon cluster through a browser.
Before you begin
When you renew or replace a self-signed SSL certificate, you must provide information for
your organization in the format that is described in the Self-signed SSL certificate data
example.
The following folders are the default locations for the server.crt and server.key
files in OneFS 6.0 and higher.
u
SSL certificate: /usr/local/apache2/conf/ssl.crt/server.crt
u
SSL certificate key: /usr/local/apache2/conf/ssl.key/server.key
Procedure
1. Establish an SSH connection to any node in the cluster.
2. At the command prompt, run the following command to create the appropriate
directory.
mkdir /ifs/local/
3. At the command prompt, run the following command to change to the directory.
cd /ifs/local/
4. Choose the type of certificate you want to install.
Option
Description
Third-party
(public or
private) CA-
issued
certificate
a. At the command prompt, run the following command to
generate a new Certificate Signing Request (CSR) in addition to
a new key, where 
<common_name>
is the host name, such as
isilon.example.com:
openssl req -new -nodes -newkey rsa:1024 -keyout 
<common name>.key \
-out <common-name>.csr
b. Send the contents of the 
<common_name>
.csr file from the
cluster to your Certificate Authority (CA) for signing. When you
receive the signed certificate (now a .crt file) from the CA,
copy the certificate to /ifs/local/<common-name>.crt.
Self-signed
certificate
based on the
existing (stock)
ssl.key
a. At the command prompt, run the following command to create
a two-year certificate. Increase or decrease the value for -days
to generate a certificate with a different expiration date.
cp /usr/local/apache2/conf/ssl.key/server.key ./openssl 
req -new \/
-days 730 -nodes -x509 -key server.key -out server.crt
A renewal certificate is created, based on the existing (stock) ssl.key file.
5. Optional: At the command prompt, run the following command to verify the attributes
in an SSL certificate.
openssl x509 -text -noout -in <common-name>.crt
6. Run the following commands to install the certificate and key:
isi services -a isi_webui disable
chmod 640 <common name>.key
General cluster administration
Replace or renew the SSL certificate
41
Convert .pdf to .jpg online - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
c# pdf to jpg; convert pdf picture to jpg
Convert .pdf to .jpg online - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert .pdf to .jpg online; convert pdf file to jpg file
isi_for_array -s 'cp /ifs/local/<common-name>.key /usr/local/
apache2/conf/ssl.key/<common-name>.key'
isi_for_array -s 'cp /ifs/local/<common-name>.crt /usr/local/
apache2/conf/ssl.crt/<common-name>.crt'
isi services -a isi_webui enable 
7. Run the following command to remove the files in /ifs/local.
rm /ifs/local/*
Verify an SSL certificate update
You can verify the details stored in a Secure Sockets Layer (SSL) certificate.
Procedure
1. Open a web browser window.
2. Browse to https://<common name>:8080, where 
<common name>
is the host
name for the EMC Isilon web administration interface, such as isilon.example.com.
3. In the security details for the web page, verify that the subject line and other details
that you provided are correct.
Note
The steps to view security details vary by browser. For example, in some browsers, you
can click the padlock icon in the address bar to view the security details for the web
page. Follow the steps that are specific to your browser.
Self-signed SSL certificate data example
Self-signed SSL certificate renewal or replacement requires you to provide data such as
your fully qualified domain name and a contact email address.
When you renew or replace a self-signed SSL certificate, you are asked to provide data in
the format shown in the following example. Some fields in the certificate file contain a
default value. If you type 
'.'
, the field is left blank when the certificate is generated.
u
Country Name (2 letter code) [XX]:
US
u
State or Province Name (full name) [Some-State]:
Washington
u
Locality Name (for example, city) [default city]:
Seattle
u
Organization Name (for example, company) [Internet Widgits Pty Ltd]:
Isilon
u
Organizational Unit Name (for example, section) []:
Support
u
Common Name (for example, server FQDN or server name) []:isilon.example.com
u
Email Address []:
support@example.com
In addition, you should add the following attributes to be sent with your certificate
request:
u
Challenge password []:
Isilon1
u
Optional company name []:
General cluster settings
General settings that are applied across the entire cluster can be modified.
You can modify the following general settings to customize the Isilon cluster for your
needs:
General cluster administration
42
OneFS
7.1 
Web Administration Guide
Online Convert Jpeg to PDF file. Best free online export Jpg image
Online JPEG to PDF Converter. Download Free Trial. Convert a JPG to PDF. You can drag and drop your JPG file in the box, and then start
batch pdf to jpg converter; convert multiple pdf to jpg
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
convert pdf image to jpg; convert pdf to jpg for
u
Cluster name
u
Cluster date and time, NTP settings
u
Character encoding
u
Email settings
u
SNMP monitoring
u
SupportIQ settings
Set the cluster name
You can assign a name and add a login message to your EMC Isilon cluster to make the
cluster and its nodes more easily recognizable on your network.
Cluster names must begin with a letter and can contain only numbers, letters, and
hyphens. The cluster name is added to the node number to identify each node in the
cluster. For example, the first node in a cluster named Images may be named Images-1.
Procedure
1. Click Cluster Management 
General Settings
Cluster Identity.
2. Optional: In the Cluster Name and Description area, type a name for the cluster in the
Cluster Name field and type a description in the Cluster Description field.
3. Optional: In the Login Message area, type a title in the Message Title field and a
message in the Message Body field.
4. Click Submit.
After you finish
You must add the cluster name to your DNS servers.
Specify contact information
You can specify contact information so that Isilon Technical Support personnel and event
notification recipients can contact you.
Procedure
1. Click Dashboard
Events
Notification Settings.
2. In the Contact Information area, click Modify contact information settings.
3. In the Contact Information area, type the name and contact information in the fields
for those details.
4. Click Submit.
Configuring the cluster date and time
The NTP service is configurable manually, so you can ensure that all nodes in a cluster are
synchronized to the same time source.
The Network Time Protocol (NTP) method automatically synchronizes cluster date and
time settings through an NTP server. Alternatively, you can set the date and time reported
by the cluster by manually configuring the service.
Windows domains provide a mechanism to synchronize members of the domain to a
master clock running on the domain controllers, so OneFS adjusts the cluster time to that
of Active Directory with a service. Whenever a cluster is joined to an Active Directory
domain and an external NTP server is not configured, the cluster is set automatically to
Active Directory time, which is synchronized by a job that runs every 6 hours. When the
General cluster administration
Set the cluster name
43
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
This demo code just converts first page to jpeg image. String inputFilePath = @"C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg.
convert pdf into jpg format; pdf to jpeg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.PDF.dll. This demo code will convert first page to jpeg image. C:\input.tif"; String outputFilePath = @"C:\output.jpg"; // Convert tiff to jpg.
changing pdf to jpg on; bulk pdf to jpg converter
cluster and domain time become out of sync by more than 4 minutes, OneFS generates
an event notification.
Note
If the cluster and Active Directory become out of sync by more than 5 minutes,
authentication will not work.
To summarize:
u
If no NTP server is configured but the cluster is joined to an Active Directory domain,
the cluster synchronizes with Active Directory every 6 hours.
u
If an NTP server is configured, the cluster synchronizes the time with the NTP server.
Set the cluster date and time
You can set the date, time, and time zone that is used by the EMC Isilon cluster.
Procedure
1. Click Cluster Management 
General Settings
Date & Time.
The Date and Time page displays a list of each node's IP address and the date and
time settings for each node.
2. From the Date and time lists, select the month, date, year, hour, and minute settings.
3. From the Time zone list, select a value.
If the time zone that you want is not in the list, select Advanced from the Time zone
list, and then select the time zone from the Advanced time zone list.
4. Click Submit.
Specify an NTP time server
You can specify one or more Network Time Protocol (NTP) servers to synchronize the
system time on the EMC cluster. The cluster periodically contacts the NTP servers and
sets the date and time based on the information it receives.
Procedure
1. Click Cluster Management 
General Settings
NTP.
2. Optional: Add a server.
a. In the Server IP or hostname field, type the host name or IP address of the NTP
server, click Add, and then click Submit.
b. Optional: To enable NTP authentication with a keyfile, type the path and file name
in the Keyfile field, and then click Submit.
3. Optional: Delete a server.
a. Select the check box next to the server name in the Server list for each server that
you want to delete.
b. Click Delete.
c. Click Submit.
General cluster administration
44
OneFS
7.1 
Web Administration Guide
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
change pdf to jpg format; .pdf to jpg
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Resize converted image files in VB.NET. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Embed PDF to image converter in viewer.
convert pdf to gif or jpg; bulk pdf to jpg
Configure SMTP email settings
You can send event notifications through the SMTP mail server. You can also enable
SMTP authentication if your SMTP server is configured to use it.
You can configure SMTP email settings if your network environment requires the use of an
SMTP server or if you want to route EMC Isilon cluster event notifications with SMTP
through a port.
Procedure
1. Click Cluster Management
General Settings
Email Settings.
2. In the Email Settings area, type the SMTP information for your environment in each
field.
3. Optional: For the Use SMTP AUTH option, select Yes, type the user credentials, and
then select a connection security option.
4. Click Submit.
You can test your configuration by sending a test event notification.
Specify the cluster join mode
You can specify the method to use when nodes are added to the EMC Isilon cluster.
Procedure
1. Click Cluster Management
General Settings
Join Mode.
2. Optional: In the Settings area, select the mode that you want to be used when nodes
are added to the cluster.
l
Manual— joins can be initiated by either the node or the cluster.
l
Secure—joins can be initiated only by the cluster.
3. Click Submit.
Cluster join modes
You can specify the method that you want to use to join nodes to a cluster. The join mode
determines how the system responds when new nodes are added to the subnet occupied
by the Isilon cluster. You can set join modes through the web administration interface or
the command-line interface.
Mode
Description
Notes
-
-
-
Manual Configures OneFS to join
new nodes to the cluster
in a separate manual
process, allowing the
addition of a node
without requiring
authorization
N/A
Secure Requires authorization
of every node added to
the cluster
If you use the secure join mode, you cannot use the serial
console wizard option 
[2] Join an existing cluster
to join a
node to the cluster. You must add the node from cluster by
using the web administration interface or the isi devices
General cluster administration
Configure SMTP email settings
45
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
Jpeg, VB.NET compress PDF, VB.NET print PDF, VB.NET merge PDF files, VB.NET view PDF online, VB.NET Convert PDF to image formats, such as PNG, JPG, BMP and
convert multi page pdf to single jpg; pdf to jpg converter
VB.NET Create PDF from images Library to convert Jpeg, png images
Components to batch convert PDF documents in Visual Basic .NET class. Support create PDF from multiple image formats in VB.NET, including Jpg, Png, Bmp, Gif
change pdf file to jpg online; .pdf to jpg converter online
Mode
Description
Notes
-
-
-
-a add -d <unconfigured_node_serial_no>
command in the command-line interface.
Enable or disable access time tracking
You can enable access time tracking to support features that require it.
By default, the EMC Isilon cluster does not track the timestamp when files are accessed.
You can enable this feature to support OneFS features that use it. For example, access-
time tracking must be enabled to configure SyncIQ policy criteria that match files based
on when they were last accessed.
Note
Enabling access-time tracking may affect cluster performance.
Procedure
1. Click File System Management 
File System Settings
Access Time Tracking.
2. In the Access Time Tracking area, select a configuration option.
l
To enable access time tracking, click Enabled, and then specify in the Precision
fields how often to update the last-accessed time by typing a numeric value and by
selecting a unit of measure, such as Seconds, Minutes, Hours, Days, Weeks,
Months, or Years.
For example, if you configure a Precision setting of 1 day, the cluster updates the
last-accessed time once each day, even if some files were accessed more often
than once during the day.
l
To disable access-time tracking, click Disabled.
3. Click Submit.
Specify the cluster character encoding
You can modify the character encoding set for the EMC Isilon cluster after installation.
Only OneFS-supported character sets are available for selection. UTF-8 is the default
character set for OneFS nodes. You must restart the cluster to apply character encoding
changes.
CAUTION
Character encoding is typically established during installation of the cluster. Modifying
the character encoding setting after installation may render files unreadable if done
incorrectly. Modify settings only if necessary after consultation with Isilon Technical
Support.
Procedure
1. Click File System Management
File System Settings
Character Encoding.
2. Optional: From the Character encoding list, select the character-encoding set that you
want to use.
3. Click Submit, and then click Yes to acknowledge that the encoding change becomes
effective after the cluster is restarted.
General cluster administration
46
OneFS
7.1 
Web Administration Guide
4. Restart the cluster.
Results
After the cluster restarts, the web administration interface reflects your change.
Cluster statistics
You can view performance, historical, and in-depth usage statistics for your EMC Isilon
cluster, and control the output for each mode of statistics reporting.
The isi statistics and isi status command-line tools include options for
querying and filtering the display of EMC Isilon cluster performance and usage statistics.
Performance monitoring
You can view cluster throughput either graphically and numerically for average and
maximum usage.
Performance information is monitored through the web administration interface, or
through the command-line interface by using the isi statistics command options.
You can view details about the input and output traffic to and from the cluster's file
system. You can also monitor throughput distribution across the cluster.
Advanced performance monitoring and analytics are available through the InsightIQ
module, which requires you to activate a separate license. For more information about
optional software modules, contact your EMC Isilon Storage Division sales
representative.
Cluster monitoring
You can monitor the health, performance, and status of your EMC Isilon cluster.
Information is available for individual nodes, including node-specific network traffic,
internal and external network interfaces, and details about node pools, tiers, and overall
cluster health. You can monitor the following areas of your EMC Isilon cluster health and
performance:
Node status
Health and performance statistics for each node in the cluster, including hard disk
drive (HDD) and solid-state drive (SSD) usage.
Client connections
Number of clients connected per node.
New events
List of event notifications generated by system events, including the severity, unique
instance ID, start time, alert message, and scope of the event.
Cluster size
Current view: Used and available HDD and SSD space and space reserved for the
virtual hot spare (VHS). Historical view: Total used space and cluster size for a one-
year period.
General cluster administration
Cluster statistics
47
Cluster throughput (file system)
Current view: Average inbound and outbound traffic volume passing through the
nodes in the cluster for the past hour. Historical view: Average inbound and
outbound traffic volume passing through the nodes in the cluster for the past two
weeks.
CPU usage
Current view: Average system, user, and total percentages of CPU usage for the past
hour. Historical view: CPU usage for the past two weeks.
Using the OneFS dashboard, you can monitor the status and health of the OneFS system
hardware. In addition, you can use SNMP to remotely monitor hardware components,
such as fans, hardware sensors, power supplies, and disks.
Monitor the cluster
You can monitor the health and performance of an EMC Isilon cluster with charts and
tables that show the status and performance of nodes, client connections, events, cluster
size, cluster throughput, and CPU usage.
Procedure
1. Click Dashboard 
Cluster Overview
Cluster Status.
2. Optional: View cluster details.
l
Status: To view details about a node, click the ID number of the node.
l
Client connection summary: To view a list of current connections, click Dashboard 
>
Cluster Overview
Client Connections Status.
l
New events: To view more information about an event, click View details in the
Actions column.
l
Cluster size: To switch between current and historical views, click Historical or
Current near the Monitoring section heading. In historical view, click Used or
Cluster size to change the display.
l
Cluster throughput (file system): To switch between current and historical views,
click Historical or Current next to the Monitoring section heading. To view
throughput statistics for a specific period within the past two weeks, click
Dashboard 
Cluster Overview
Throughput Distribution.
Note
You can hide or show inbound or outbound throughput by clicking Inbound or
Outbound in the chart legend. To view maximum throughput, next to Show, select
Maximum.
l
CPU usage: To switch between current and historical views, click Historical or
Current near the Monitoring section heading.
Note
You can hide or show a plot by clicking System, User, or Total in the chart legend.
To view maximum usage, next to Show, select Maximum.
General cluster administration
48
OneFS
7.1 
Web Administration Guide
View node status
You can view the current and historical status of a node.
Procedure
1. Click Dashboard 
Cluster Overview
Cluster Status.
2. Optional: In the Status area, click the ID number for the node that you want to view
status for.
3. View node details.
l
Status: To view networks settings for a node interface or subnet or pool, click the
link in the Status area.
l
Client connections: To view current clients connected to this node, review the list
in this area.
l
Chassis and drive status: To view the state of drives in this node, review this area.
To view details about a drive, click the name link of the drive; for example, Bay1.
l
Node size: To switch between current and historical views, click Historical or
Current next to the Monitoring area heading. In historical view, click Used or
Cluster size to change the display accordingly.
l
Node throughput (file system): To switch between current and historical views,
click Historical or Current next to the Monitoring area heading. To view throughput
statistics for a period within the past two weeks, click Dashboard 
Cluster
Overview
Throughput Distribution.
Note
You can hide or show inbound or outbound throughput by clicking Inbound or
Outbound in the chart legend. To view maximum throughput, next to Show, select
Maximum.
l
CPU usage: To switch between current and historical views, click Historical or
Current next to the Monitoring area heading.
Note
You can hide or show a plot by clicking System, User, or Total in the chart legend.
To view maximum usage, next to Show, select Maximum.
Events and notifications
You can monitor the health and performance of your EMC Isilon cluster through OneFS
event notifications.
You can select the OneFS hardware, software, network, and system events that you want
to monitor, and you can cancel, quiet, or unquiet events. In addition, you can configure
event notification rules to send an email notification or SNMP trap when a threshold is
exceeded.
Event notification methods
You can configure event notification rules to generate and deliver event notifications
when an event occurs.
You can notify users by email, SupportIQ, or SNMP trap.
General cluster administration
View node status
49
Email
You can designate recipients and specify SMTP, authorization, and security settings.
You can specify batch email settings and the email notification template.
SupportIQ
You can specify a protocol that you prefer to use for notifications: HTTPS, SMTP, or
both.
SNMP trap
You can send SNMP traps to one or more network monitoring stations or trap
receivers. Each event can generate one or more SNMP traps. You can download
management information base files (MIBs) from the cluster at /usr/local/
share/snmp/mibs/. The ISILON-TRAP-MIB.txt file describes the traps that
the cluster can generate, and the ISILON-MIB.txt file describes the associated
varbinds that accompany the traps.
Note
You must configure an event notification rule to generate SNMP traps.
Event notification settings
You can specify whether you want to receive event notifications as aggregated batches or
as individual notifications for each event. Batch notifications are sent every 10 seconds.
The batch options that are described in this table affect both the content and the subject
line of notification emails that are sent in response to system events. You can specify
event notification batch options when you configure SMTP email settings.
Setting
Option
Description
-
-
-
Notification batch
mode
Batch all
Generates a single email for each event
notification.
Batch by severity
Generates an email that contains
aggregated notifications for each event of
the same severity, regardless of event
category.
Batch by category
Generates an email an email that contains
aggregated notifications for event of the
same category, regardless of severity.
No batching
Generates one email per event.
Custom notification
template
No custom notification
template is set
Sends the email notification in the default
OneFS notification template format.
Set custom notification
template
Sends the email notifications in the format
that you defined in your custom template
file.
General cluster administration
50
OneFS
7.1 
Web Administration Guide
Documents you may be interested
Documents you may be interested