Managing antivirus reports
In addition to viewing antivirus reports through the web administration interface, you can
export reports to a comma-separated values (CSV) file. You can also view events that are
related to antivirus activity.
Export an antivirus report
You can export an antivirus report to a comma separated values (CSV) file.
Procedure
1. Click Data Protection
Antivirus
Reports.
2. In the Reports table, in the row for a report, click Export.
3. Save the CSV file.
View antivirus reports
You can view antivirus reports.
Procedure
1. Click Data Protection
Antivirus
Reports.
2. In the Reports table, in the row for a report, click View Details.
View antivirus events
You can view events that relate to antivirus activity.
Procedure
1. Click Dashboard
Events
Event History.
2. In the Event History table, view all events.
All events related to antivirus scans are classified as warnings. The following events
are related to antivirus activities:
Anti-Virus scan found threats
A threat was detected by an antivirus scan. These events refer to specific reports
on the Antivirus Reports page but do not provide threat details.
No ICAP Servers available
OneFS is unable to communicate with any ICAP servers.
ICAP Server Unresponsive or Invalid
OneFS is unable to communicate with an ICAP server.
Antivirus
Managing antivirus reports
401
Changing pdf to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf to jpg 300 dpi; convert pdf to 300 dpi jpg
Changing pdf to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert pdf file to jpg format; change from pdf to jpg
VB.NET PDF File Merge Library: Merge, append PDF files in vb.net
combine various scanned images to PDF, such as tiff, jpg, png, gif PDF together and save as new PDF, without changing the previous two PDF documents at
best pdf to jpg converter online; best program to convert pdf to jpg
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
PDF. Supports tiff compression selection. Supports for changing image size. Also supports convert PDF files to jpg, jpeg images. C#
convert pdf to jpg batch; change file from pdf to jpg on
CHAPTER 23
iSCSI
This section contains the following topics:
u
iSCSI overview.....................................................................................................404
u
iSCSI targets and LUNs........................................................................................404
u
iSNS client service...............................................................................................405
u
Access control for iSCSI targets...........................................................................405
u
iSCSI considerations and limitations...................................................................406
u
Supported SCSI mode pages...............................................................................406
u
Supported iSCSI initiators...................................................................................407
u
Configuring the iSCSI and iSNS services..............................................................407
u
Managing iSCSI targets.......................................................................................409
u
Configuring iSCSI initiator access control............................................................411
u
Creating iSCSI LUNs.............................................................................................415
u
Managing iSCSI LUNs..........................................................................................418
iSCSI
403
VB.NET Image: PDF to Image Converter, Convert Batch PDF Pages to
used commonly in daily life (like tiff, jpg, png, bitmap format in VB programming code, like changing "tif" to users are also allowed to convert PDF to other
change file from pdf to jpg; convert multipage pdf to jpg
C# Tiff Convert: How to Convert Raster Images (Jpeg/Png/Bmp/Gif)
Give You Sample Codes for Changing and Converting Jpeg, Png RasterEdge.XDoc.PDF.dll. String inputFilePath = @"C:\input.jpg"; String outputFilePath = @"C:\output
best pdf to jpg converter for; convert .pdf to .jpg
iSCSI overview
The Isilon iSCSI module enables customers to provide block storage for Microsoft
Windows, Linux, and VMware systems over an IP network. To access the iSCSI module,
you must activate a separate license.
Note
The iSCSI module is supported by exception only and is limited to certain use cases. It is
recommended that you find other solutions for your block storage requirements.
You can create and manage iSCSI targets on a cluster. The targets are available as SCSI
block devices on which you can store structured and unstructured data. iSCSI targets
contain one or more logical units, each uniquely identified by a logical unit number (LUN).
You can format and connect to targets, such as physical disk devices, on the local file
system.
You can configure each target to limit access to a list of initiators. You can also require
initiators to authenticate with a target by using the Challenge-Handshake Authentication
Protocol (CHAP).
The iSCSI module includes the following features:
u
Support for Microsoft Internet Storage Name Service (iSNS) server
u
Isilon SmartConnect Advanced dynamic IP allocation
u
Isilon FlexProtect
u
Data mirroring from 2x to 8x
u
LUN cloning
u
One-way CHAP authentication
u
Initiator access control
iSCSI targets and LUNs
A logical unit is a storage object (such as a disk or disk array) that is accessible by an
iSCSI target on an Isilon cluster. Each logical unit is uniquely identified by a logical unit
number (LUN). Although a LUN is an identifier for a logical unit, the terms are often used
interchangeably. A logical unit must be associated with a target, and each target can
contain one or more logical units.
The following table describes the three types of LUNs that the Isilon iSCSI module
supports:
LUN Type
Description
-
-
Normal
A normal LUN is the default LUN type for clone and imported LUNs, and the only type
available for newly created LUNs. Normal LUNs are either writeable or read-only.
Snapshot A snapshot LUN is a copy of a normal LUN or another snapshot LUN. Although
snapshot LUNs require little time and disk space to create, they are read-only. You
can create snapshot LUNs by cloning existing normal or snapshot LUNs, but you
cannot create snapshot clones of clone LUNs.
Clone
A clone LUN is a copy of a normal, snapshot, or clone LUN. Clone LUNs are
implemented using overlay and mask files in conjunction with a snapshot. Clone
iSCSI
404
OneFS
7.1 
Web Administration Guide
XDoc.HTML5 Viewer for .NET, All Mature Features Introductions
PowerPoint: PPT, PPTX, PPS, PPSX; PDF: Portable Document Raster Image Files: BMP, GIF, JPG, PNG, JBIG2PDF in or zoom out functions, and changing file rotation
convert pdf file to jpg on; best pdf to jpg converter
LUN Type
Description
-
-
LUNs require little time and disk space to create, and the LUN is fully writeable. You
can create clone LUNs by cloning or importing existing LUNs.
SmartConnect and iSCSI targets
You can specify a SmartConnect service IP or virtual IP address for an initiator when
connecting to iSCSI targets.
When an initiator connects to a target with the SmartConnect service, the iSCSI session is
redirected to a node in the cluster, based on the SmartConnect connection policy
settings. The default connection policy setting is round robin. If the SmartConnect service
is configured for dynamic IP allocation, connections are redirected to other nodes in case
of failure. Dynamic IP allocation is available only if you activate a SmartConnect
Advanced license.
iSNS client service
iSCSI initiators can discover and connect to iSCSI targets through the Microsoft Internet
Storage Name Service (iSNS) protocol.
The iSNS server establishes a repository of active iSCSI nodes. The nodes can be
initiators or targets. In addition, you can enable, disable, configure, and test the iSNS
client service through the iSCSI module in OneFS.
Access control for iSCSI targets
The iSCSI module supports Challenge-Handshake Authentication Protocol (CHAP) and
initiator access control for connections to individual targets.
The CHAP and initiator access control security options can be implemented together or
used separately.
CHAP authentication
You can authenticate initiator connections to iSCSI targets with the Challenge-Handshake
Authentication Protocol (CHAP).
You can restrict initiator access to a target by enabling CHAP authentication and then
adding user:secret pairs to the target's CHAP secrets list. If you enable CHAP
authentication, initiators are required to provide a valid user:secret pair to authenticate
their connections to the target. CHAP authentication is disabled by default.
Note
The Isilon iSCSI module does not support mutual CHAP authentication.
iSCSI
SmartConnect and iSCSI targets
405
Initiator access control
You can control which initiators are allowed to connect to a target by enabling initiator
access control and configuring the target's initiator access list. By default, initiator access
control is disabled, and all initiators are allowed to access the target.
You can restrict access to a target by enabling access control and then adding initiators
to the target's initiator access list. If you enable access control but leave the initiator
access list empty, no initiators are able to access the target.
iSCSI considerations and limitations
When planning your iSCSI deployment, be aware of the following limitations and
considerations.
u
Multipath I/O (MPIO) is recommended only for iSCSI workflows that have primarily
read-only operations. The node must invalidate the data cache on all other nodes
during file-write operations and performance decreases in proportion to the number
of write operations. If all MPIO sessions are connected to the same node,
performance should not decrease.
u
The Isilon iSCSI module supports one-way Challenge-Handshake Authentication
Protocol (CHAP). The authentication configuration is shared by all of the nodes, so a
target authenticates its initiator regardless of the node the initiator is connecting
through.
u
The Isilon iSCSI module supports the importing of normal LUNs only. Importing
snapshot LUNs and clone LUNs is not supported. You cannot back up and then
restore a snapshot or clone LUN, or replicate snapshot or clone LUNs to another
cluster. It is recommended that you deploy a backup application to back up iSCSI
LUNs on the iSCSI client, as the backup application ensures that the LUN is in a
consistent state at the time of backup.
u
The Isilon iSCSI module does not support the following:
l
Internet Protocol Security (IPsec)
l
Multiple connections per session (MCS)
l
iSCSI host bus adaptors (HBAs)
l
Mutual CHAP authentication
Supported SCSI mode pages
The SCSI Mode Sense command is used to obtain device information from mode pages in
a target device. The Mode Select command is used to set new values.
OneFS supports the following mode pages:
Mode page name
Page code
Subpage code
-
-
-
Caching mode page*
08h
00h
Return all mode pages only
3Fh
00h
Control mode page**
0Ah
00h
Informational exceptions control mode page e 1Ch
00h
iSCSI
406
OneFS
7.1 
Web Administration Guide
* For the caching mode page, OneFS supports the write cache enable (WCE) parameter
only.
** OneFS supports querying this mode page through the Mode Sense command, but
does not support changing the fields of this page through the Mode Select command.
Supported iSCSI initiators
OneFS 7.0.0 or later is compatible with the following iSCSI initiators.
Operating System
iSCSI Initiator
-
-
Microsoft Windows 2003 (32-bit and 64-bit) ) Microsoft iSCSI Initiator 2.08 or later (Certified)
Microsoft Windows 2008 (32-bit and 64-bit) ) Microsoft iSCSI Initiator (Certified)
Microsoft Windows 2008 R2 (64-bit only)
Microsoft iSCSI Initiator (Certified)
Red Hat Enterprise Linux 5
Linux Open-iSCSI Initiator (Supported)
VMware ESX 4.0 and ESX 4.1
iSCSI Initiator (Certified)
VMware ESXi 4.0 and ESXi 4.1
iSCSI Initiator (Certified)
VMware ESXi 5.0
iSCSI Initiator (Certified)
Configuring the iSCSI and iSNS services
You can disable or enable and configure the iSCSI service and the iSNS client service. You
can find targets for iSCSI initiators through the iSNS client service. The settings for the
iSCSI and iSNS services are applied to all of the nodes in the cluster. You cannot modify
these settings for individual nodes.
Configure the iSCSI service
You can enable or disable the iSCSI service for all the nodes in a cluster.
Before you disable the iSCSI service, be aware of the following considerations:
u
All of the current iSCSI sessions will be terminated for all the nodes in the cluster.
u
Initiators cannot establish new sessions until the iSCSI service is re-enabled.
Procedure
1. Click File System Management
iSCSI
Settings.
2. In the iSCSI Service area, set the service state that you want:
l
If the service is disabled, you can enable it by clicking Enable.
l
If the service is enabled, you can disable it by clicking Disable.
iSCSI
Supported iSCSI initiators
407
Configure the iSNS client service
You can configure and enable or disable the Internet Storage Name Service (iSNS), which
iSCSI initiators use to discover targets.
Procedure
1. Click File System Management
iSCSI
Settings.
2. In the iSNS Client Service area, configure the iSNS client service settings:
l
iSNS server address: Type the IP address of the iSNS server with which you want to
register iSCSI target information.
l
iSNS server port: Type the iSNS server port number. The default port number is
3205.
3. Click Test connection to validate the iSNS configuration settings.
If the connection to the iSNS server fails, check the iSNS server address and the iSNS
server port number.
4. Click Submit.
5. Change the service to the state that you want:
l
If the service is disabled, you can enable it by clicking Enable. Enabling the service
allows OneFS to register information about iSCSI targets.
l
If the service is enabled, you can disable it by clicking Disable. Disabling the
service prevents OneFS from registering information about iSCSI targets.
View iSCSI sessions and throughput
If the iSCSI service is enabled on the cluster, you can view a summary of current iSCSI
sessions and current throughput.
Note
To view historical iSCSI throughput data, you must obtain the EMC Isilon InsightIQ virtual
appliance, which requires you to activate a separate license. For more information,
contact your EMC Isilon representative.
Procedure
1. Click File System Management
iSCSI
Summary.
2. Review the current throughput data and current session information.
l
The Current Throughput area displays a chart that illustrates overall inbound and
outbound throughput across all iSCSI sessions during the past hour, measured in
kilobits per second (Kbps). This chart automatically updates every 15 seconds.
l
The Current Sessions area displays information about each current connection
between an initiator and a target, including the client and target IP addresses;
node, target, and LUN; operations per second; and the inbound, outbound, and
total throughput in bits per second. You can view details about a target by clicking
the target name.
iSCSI
408
OneFS
7.1 
Web Administration Guide
Managing iSCSI targets
You can configure one or more targets for an iSCSI server, and each target can contain
one or more logical units.
iSCSI initiators on clients establish connections to the targets. Targets define connection
endpoints and serve as container objects for logical units on an iSCSI server.
You can control access to the target by configuring SmartConnect pools, initiator access
control, and authentication with the Challenge-Handshake Authentication Protocol
(CHAP). The iSCSI module discovers targets through a server running Microsoft Internet
Storage Name Service (iSNS).
Create an iSCSI target
You can configure one or more iSCSI targets, each with its own settings for initiator
access control and authentication. A target is required as a container object for one or
more logical units.
Procedure
1. Click File System Management 
iSCSI
Targets & Logical Units.
2. In the Targets area, click Add target.
3. In the Name field, type a name for the target.
The name must begin with a letter and can contain only lowercase letters, numbers,
and hyphens (-).
4. In the Description field, type a descriptive comment for the target.
5. In the Default path field, type the full path of the directory, beginning with /ifs,
where the logical unit number (LUN) directory is created, or click Browse to select a
directory.
Note
This directory is used only if no other directory is specified during LUN creation or if a
LUN is not created. The directory must be in the /ifs directory tree. The full path to
the directory is required, and wildcard characters are not supported.
6. Add one or more SmartConnect pools for the target to connect with. This setting
overrides any global default SmartConnect pools that are configured for iSCSI targets.
a. For the SmartConnect pool(s) setting, click Edit list.
b. Move pools between the Available Pools and Selected Pools lists by clicking a
pool and then clicking the right or left arrow. To remove all selected pools at once,
click clear.
c. Click OK.
7. Click Submit.
8. Optional: In the Initiator Access Control area, enable and configure the settings for
initiator access control.
a. Click Enable to restrict target access to initiators that are added to the initiator
access control settings.
b. Click Add initiator.
iSCSI
Managing iSCSI targets
409
c. In the Initiator name field, type the name of the initiator that you want to allow to
access this target, or click Browse to select from a list of initiators. An initiator
name must begin with an iqn. prefix.
d. Click OK.
Note
To continue adding initiators, click OK and add another. When you are finished adding
initiators, click OK.
9. Optional: In the CHAP Authentication area, enable and configure Challenge-
Handshake Authentication Protocol (CHAP) settings.
Note
If CHAP authentication is enabled and the CHAP secrets list is empty, no initiators can
access the target.
a. Click Enable to require initiators to authenticate with the target.
b. Click Add username.
c. In the Username field, type the name that the initiator will use to authenticate with
the target. You can specify an initiator's iSCSI qualified name (IQN) as the
username. Depending on whether you specify an IQN, valid usernames differ in the
following ways:
If you specify an IQN as the username, the Username value must begin with an
iqn. prefix. The characters that are allowed after the iqn. prefix are
alphanumeric characters, periods (.), hyphens (-), and colons (:).
All other usernames can use alphanumeric characters, periods (.), hyphens (-),
and underscores (_).
Note
CHAP usernames and passwords are case sensitive.
d. In the Secret and Confirm secret fields, type the secret that the initiator will use to
authenticate with the target. A CHAP secret must be 12 to 16 characters long and
can contain any combination of letters, numbers, and symbols.
e. Click OK.
10.Click Submit.
Modify iSCSI target settings
You can modify a target's description, change the path where logical unit directories are
created, and modify the list of SmartConnect pools that the target uses. You can also
manage the target's settings for initiator access control and authentication.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to modify.
3. Modify the target's settings as needed.
iSCSI
410
OneFS
7.1 
Web Administration Guide
Documents you may be interested
Documents you may be interested