Note
l
Changing the default path does not affect existing logical units.
l
Changing the security settings does not affect existing connections.
4. Click Submit.
Delete an iSCSI target
When you delete a target, all of the logical unit numbers (LUNs) that are contained in the
target are also deleted, and all the data that is stored in the LUNs is deleted. Additionally,
any iSCSI sessions that are connected to the target are terminated. This operation cannot
be undone.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Delete for the target that you want to delete.
3. In the confirmation dialog box, click Yes.
The target and all LUNs and LUN data that are contained in the target are deleted, and
any iSCSI sessions on the target are terminated.
View iSCSI target settings
You can view information about a target, including its iSCSI qualified name (IQN), default
LUN directory path, capacity, and SmartConnect pool settings. You can also view the
logical units that are associated with the target as well as the settings for initiator access
control and authentication.
Procedure
1. Click File System Management 
iSCSI
Targets & Logical Units.
2. In the Targets area, click the name of a target.
3. Review the following sections for information on the target. To modify these settings,
click Edit target.
l
Target Details: Displays the target name, IQN, description, default path, capacity,
and SmartConnect pool settings. The name and IQN cannot be modified.
l
Logical Units: Displays any logical units that are contained in the target. You can
add or import a logical unit, or manage existing logical units. You can also select
the columns to display or hide.
l
Allowed Initiators: Displays the target's initiator access control status, and lists
the names of any initiators that are allowed to access the target when access
control is enabled.
l
CHAP Authentication: Displays the target's CHAP authentication status, and lists
all user:secret pairs for the target.
Configuring iSCSI initiator access control
You can configure access control to specify which initiators are allowed to connect to a
target. Access control is disabled by default.
If you enable initiator access control for an iSCSI target, access to that target is limited to
a specified list of allowed initiators. If you modify a target's access control settings, the
iSCSI
Delete an iSCSI target
411
Batch pdf to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
change pdf to jpg; conversion of pdf to jpg
Batch pdf to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
reader pdf to jpeg; change from pdf to jpg on
changes are applied to subsequent connection requests. Current connections are
unaffected.
Configure iSCSI initiator access control
You can configure access control to specify which initiators are allowed to connect to a
target.
If initiator access control is enabled for an iSCSI target, access is limited to a list of
initiators. Access control is disabled by default.
Note
Modifications to a target's access control settings are applied to subsequent connection
requests. Current connections are not affected.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target whose initiator access state
you want to change.
3. In the Initiator Access Control area, configure the access control state.
l
If access control is disabled, click Enable to restrict target access to initiators that
you add to the initiator access list.
Note
If you disable access control and the initiator access list is empty, no initiators are
able to connect to the target.
l
If access control is enabled, click Disable to allow all initiators access to the
target.
Note
If you disable access control, the list of allowed initiators is ignored.
4. Add initiators by clicking Add initiator.
Control initiator access to a target
You can control access to a target by adding initiators to its initiator access list. If you
enable initiator access control, the initiator access list specifies which initiator names are
allowed to access the target. However, the initiator access list is ignored unless initiator
access control is enabled.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to allow an
initiator to access.
3. In the Initiator Access Control area, click Add initiator.
4. In the Initiator name field, type the name of the initiator that you want to allow to
access the target, or click Browse to select from a list of known initiators. An initiator
name requires the iqn. prefix.
5. Click OK.
iSCSI
412
OneFS
7.1 
Web Administration Guide
JPEG to PDF Converter | Convert JPEG to PDF, Convert PDF to JPEG
similar software; Support a batch conversion of JPG to PDF with amazingly high speed; Get a compressed PDF file after conversion; Support
change pdf file to jpg; .pdf to jpg
JPG to DICOM Converter | Convert JPEG to DICOM, Convert DICOM to
Open JPEG to DICOM Converter first; Load JPG images from local folders in "File" in toolbar Windows Explorer; Select "Batch Conversion" & Choose "DICOM" in
changing pdf file to jpg; reader pdf to jpeg
6. To continue adding initiators, click OK and add another.
7. When you are finished adding initiators, click OK.
Modify initiator name
You can rename or replace an initiator that is allowed to connect to a target when access
control is enabled.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to modify.
3. In the Initiator Access Control area, click Edit for the initiator that you want to modify.
4. Modify the initiator name.
5. Click OK.
Remove an initiator from the access list
You can remove an initiator from a target's initiator access list so that the initiator is no
longer able to connect to a target when access control is enabled.
Note
u
If you remove all of the allowed initiators for a target and access control is enabled,
the target will deny new connections until you disable access control.
u
Removing an allowed initiator for a target does not affect the initiator's access to
other targets.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to modify.
3. In the Initiator Access Control area, under Actions, click Delete for the initiator that
you want to remove from the access list.
4. In the confirmation dialog box, click Yes.
Create a CHAP secret
To use CHAP authentication, you must create user:secret pairs in the target's CHAP
secrets list and enable CHAP authentication. Initiators must then authenticate with the
target by providing a user:secret pair.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to create a
CHAP secret for.
3. In the CHAP Authentication area, click Add username.
4. In the Username field, type the name that the initiator uses to authenticate with the
target.
You can specify an initiator's iSCSI qualified name (IQN) as the username.
iSCSI
Modify initiator name
413
JPG to GIF Converter | Convert JPEG to GIF, Convert GIF to JPG
Open JPEG to GIF Converter first; Load JPG images from local folders in "File" in toolbar Windows Explorer; Select "Batch Conversion" & Choose "GIF" in "Output
changing pdf to jpg on; change pdf to jpg online
JPG to JBIG2 Converter | Convert JPEG to JBIG2, Convert JBIG2 to
Ability to preserve original images without any affecting; Ability to convert image swiftly between JPG & JBIG2 in single and batch mode;
pdf to jpeg converter; batch convert pdf to jpg online
l
If you specify an IQN as the username, the Username value must begin with an
iqn. prefix. The characters that are allowed after the iqn. prefix are alphanumeric
characters, periods (.), hyphens (-), and colons (:).
l
All other usernames can use alphanumeric characters, periods (.), hyphens (-), and
underscores (_).
Note
CHAP usernames and passwords are case sensitive.
5. In the Secret and Confirm secret fields, type the secret that the initiator will use to
authenticate with the target. A CHAP secret must be 12 to 16 characters long and can
contain any combination of letters, numbers, and symbols.
6. Click OK.
Modify a CHAP secret
You can modify the settings for a CHAP user:secret pair.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to modify a
CHAP user:secret pair for.
3. In the CHAP Authentication area, under Actions, click Edit for the username whose
settings you want to modify.
4. Make the changes that you want, and then click OK.
Delete a CHAP secret
You can delete a CHAP user:secret pair that is no longer needed.
Note
If you delete all of a target's CHAP secrets and CHAP authentication is enabled, no
initiators are able to access the target until you disable CHAP authentication.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target that you want to delete a
CHAP user:secret pair for.
3. In the CHAP Authentication area, under Actions, click Delete for the CHAP user:secret
pair that you want to delete.
4. In the confirmation dialog box, click Yes.
Enable or disable CHAP authentication
You can enable or disable CHAP authentication for a target.
Note
Modifications to a target's CHAP authentication status are applied to subsequent
connection requests. Current connections are unaffected.
iSCSI
414
OneFS
7.1 
Web Administration Guide
JPG to Word Converter | Convert JPEG to Word, Convert Word to JPG
Open JPEG to Word Converter first; Load JPG images from local folders in "File" in toolbar Windows Explorer; Select "Batch Conversion" & Choose "Word" in
c# pdf to jpg; best convert pdf to jpg
JPG to JPEG2000 Converter | Convert JPEG to JPEG2000, Convert
Open JPEG to JPEG2000 Converter first; ad JPG images from local folders in "File" in toolbar Windows Explorer; Select "Batch Conversion" & Choose "JPEG2000" in
convert pdf into jpg online; convert pdf pages to jpg
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Targets area, under Actions, click Edit for the target whose CHAP authentication
state you want to modify.
3. In the CHAP Authentication area, configure the initiator's CHAP authentication state.
l
If CHAP authentication is disabled, you can click Enable to require initiators to
authenticate with the target.
Note
If CHAP authentication is enabled and the CHAP secrets list is empty, no initiator is
able to access the target.
l
If CHAP authentication is enabled, click Disable to stop authenticating initiators
with the target.
Note
If CHAP authentication is disabled, the CHAP secrets list is ignored.
4. Add CHAP user:secret pairs by clicking Add username.
Creating iSCSI LUNs
You can create a new LUN or you can clone an existing LUN to form a new LUN. LUN
cloning, like LUN creation, is asynchronous.
When you create a LUN, you can set its target assignment, LUN number, directory path,
size, provisioning policy, access state, write access, protection settings, and I/O
optimization settings. The LUN number uniquely identifies the logical unit.
When you clone an existing LUN, you can set that LUN to be part of the same target or a
different target. A cloned LUN is inaccessible by iSCSI initiators until the cloning is
complete.
To clone a LUN, you must enable the Isilon SnapshotIQ module, which requires you to
activate a separate license. For more information, contact your EMC Isilon sales
representative.
Create an iSCSI LUN
You can create a logical unit and assign it to an iSCSI target for access.
Note
When you create a logical unit, you must assign it to an existing iSCSI target. Each target
can contain one or more logical units.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, click Add logical unit.
3. In the Add Logical Unit area, in theDescription field, type a descriptive comment for
the logical unit.
4. From the Target list, select the target that will contain the logical unit.
iSCSI
Creating iSCSI LUNs
415
JPG to PNG Converter | Convert JPEG to PNG, Convert PNG to JPG
Open JPEG to PNG Converter first; Load JPG images from local folders in "File" in toolbar Windows Explorer; Select "Batch Conversion" & Choose "PNG" in "Output
convert pdf to jpg 100 dpi; convert pdf to jpg batch
VB.NET Image: PDF to Image Converter, Convert Batch PDF Pages to
and non-professional end users to convert PDF and PDF/A documents to many image formats that are used commonly in daily life (like tiff, jpg, png, bitmap, jpeg
.pdf to .jpg converter online; best pdf to jpg converter for
5. Select one of the LUN number options.
l
To assign the next available number to the logical unit, click Automatic. This is the
default setting.
l
To manually assign a number to the logical unit, click Manual and then, in the
Number field, type an integer value. The value must be within the range 0-255
and must not be assigned to another logical unit within the target.
By default, the LUN number forms part of the directory name that is created for storing
the LUN data.
6. To manually specify the path where the LUN directory is created, in the Path field, type
the full path of the directory, beginning with /ifs, or click Browse to select the
directory.
The directory must be in the /ifs directory tree. You must specify the full path to the
directory, and wildcard characters are not allowed. The default path is /ifs/iscsi/
ISCSI.LUN.<TargetName>.<LUNnumber>, where 
<TargetName>
is the Target
value and 
<LUNnumber> 
is the LUN number.
7. In the Size field, specify the LUN capacity by typing an integer value and then
selecting a unit of measure from the list (MB, GB, or TB).
The minimum LUN size is 1 MB. The maximum LUN size is determined by the OneFS
file system. After you create a LUN, you can increase its size, but you cannot decrease
it.
8. Select one of the Provisioning options.
l
To specify that blocks are unallocated until they are written, click Thin provision.
l
To immediately allocate all the blocks, click Pre-allocate space. This is the default
setting.
Note
Allocation of all the blocks for a large LUN can take hours or even days.
9. Select one of the LUN access options.
l
To make the LUN accessible, click Online. This is the default setting.
l
To make the LUN inaccessible, click Offline.
10.Select one of the Write access options.
l
To allow iSCSI initiators to write to the LUN, click Read-Write. This is the default
setting.
l
To prevent iSCSI initiators from writing to the LUN, click Read-Only.
11.Under Protection Settings, from the Disk pool list, select the disk pool to contain the
logical unit.
12.From the SSD strategy list, select to specify a strategy to use if solid-state drives
(SSDs) are available.
l
Metadata read acceleration (Recommended): Writes metadata and all user data on
hard disk drives (HDDs) and additionally creates a mirror backup of the metadata
on an SSD. Depending on the global namespace acceleration setting, the SSD
mirror may be an extra mirror in addition to the number required to satisfy the
protection level.
l
Metadata read/write acceleration with performance redundancy (Requires more
SSD space): Writes all metadata on an SSD and writes all user data on HDDs.
iSCSI
416
OneFS
7.1 
Web Administration Guide
l
Data on SSDs (Requires most SSD space): Similar to metadata acceleration, but
also writes one copy of the file's user data (if mirrored) or all of the data (if not
mirrored) on SSDs. Regardless of whether global namespace acceleration is
enabled, any SSD blocks reside on the file's target pool if there is room. This SSD
strategy does not create additional mirrors beyond the normal protection level.
l
Avoid SSDs (Reduces performance): Never uses SSDs; writes all associate file data
and metadata to HDDs only.
13.From the Protection level list, select a protection policy for the logical unit. Select Use
iSCSI default (2x), which is the recommended setting for best performance, or one of
the mirrored options, such as 2x to 8x.
14.Select one of the Write Cache options.
l
To prevent write caching for files that contain LUN data, click Disabled. This is the
recommended setting for LUNs.
l
To allow write caching for files that store LUN data, click Enable.
Note
The Write Cache option controls whether file writes are sent to the coalescer or the
endurant cache. With Write Cache disabled, which is the default and recommended
setting, all file writes are sent to the endurant cache. The endurant cache is a
committed data guarantee. If Write Cache is enabled, all file writes are sent to the
coalescer. Write caching can improve performance, but can lead to data loss if a node
loses power or crashes while uncommitted data is in the write cache.
15.Select one of the Data access pattern options.
l
To select a random access pattern, click Random. This is the recommended setting
for LUNs.
l
To select a concurrent access pattern, click Concurrency.
l
To select a streaming access pattern, click Streaming. Streaming access patterns
can improve performance in some workflows.
16.Click Submit.
Clone an iSCSI LUN
You can clone an existing LUN to a create a new LUN.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, under Actions, click Clone for the logical unit that you want
to clone.
The page updates and the clone options appear. Most of the fields for these options
are populated with information from the logical unit you selected to clone.
3. From the LUN type list, select Normal, Clone, or Snapshot.
4. Modify the other settings as needed.
Note
The settings for the clone vary according to the source LUN type.
5. Click Submit.
iSCSI
Clone an iSCSI LUN
417
iSCSI LUN cloning operations
Depending on the clone LUN type, the contents (or blocks) of a source LUN are either
copied or referenced, and the attributes may or may not be copied. In general, clone and
snapshot type clone operations are fast, whereas normal type clones can take several
minutes or even hours to create, depending on the size of the LUN.
The following table describes the result of each cloning operation.
Source LUN
type
Clone LUN
type
Result
-
-
-
Normal
Normal
A snapshot of the source LUN is created. The clone LUN is then created by copying the LUN data
from the snapshot. After completing the copy, the snapshot is deleted. The copy process may take
several hours to complete for large LUNs if the source LUN has a pre-allocated provisioning policy.
The copy process may also take several minutes for thinly provisioned LUNs that are significantly
used.
Normal
Snapshot
A snapshot of the source LUN is created. The clone LUN is configured to reference the data from
the snapshot. The snapshot is deleted when the clone is deleted.
Normal
Clone
A snapshot of the source LUN is created. The system then creates a clone LUN that references data
from the snapshot.
Snapshot
Normal
The clone LUN is created by copying the LUN data from the snapshot. The copy process may take
several minutes to complete for large LUNs if the source LUN has a pre-allocated provisioning
policy. The copy process may also take several minutes for thinly provisioned LUNs that are heavily
used.
Snapshot
Snapshot
The clone LUN is configured to reference the data from the same snapshot that the source LUN
references. The underlying snapshot is not deleted when a LUN is deleted unless the LUN being
deleted is the last LUN referencing the snapshot.
Snapshot
Clone
The clone LUN is configured to reference the data from the same snapshot that the source LUN
references. The underlying snapshot is not deleted when a LUN is deleted unless the LUN being
deleted is the only LUN referencing the snapshot.
Clone
Normal
A snapshot of the source LUN is created. The clone LUN is then created by copying the LUN data
from the snapshot. After completing the copy, the snapshot is deleted. The copy process may take
several minutes to complete for large LUNs if the source LUN has a pre-allocated provisioning
policy. The copy process may also take several minutes for thinly provisioned LUNs that are heavily
used
Clone
Snapshot
Not allowed.
Clone
Clone
A clone of the clone LUN is created. The clone LUN is configured to reference data from the
snapshot.
Managing iSCSI LUNs
You can manage a LUN in the following ways.
u
Modify a LUN
u
Delete a LUN
u
Migrate a LUN to another target
iSCSI
418
OneFS
7.1 
Web Administration Guide
u
Import a LUN
u
View LUN settings
Modify an iSCSI LUN
You can modify only certain settings for a logical unit.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, under Actions, click Edit for the logical unit that you want to
modify.
3. Modify the logical unit's settings.
4. Click Submit.
Delete an iSCSI LUN
Deleting a logical unit permanently deletes all data on the logical unit. This operation
cannot be undone.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, under Actions, click Delete for the logical unit that you want
to delete.
3. In the confirmation dialog box, click Yes.
Migrate an iSCSI LUN to another target
You can move a logical unit from one target to another, change the value of its logical unit
number (LUN), or update the path to the LUN directory. You cannot modify the path of a
snapshot LUN.
The name of a logical unit comprises its target name and its LUN value. The two parts of
the name are separated by a colon (such as "mytarget:0").
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, under Actions, click Move for the logical unit that you want
to move.
3. In the To target list, click to select a new target for the logical unit.
4. Click one of the To LUN number options.
l
To assign the next available number to the logical unit, click Automatic. This is the
default setting.
l
To manually assign a number to the logical unit, click Manual and then, in the
Number box, type an integer value. The value must be within the range 0-255 and
must not be assigned to another logical unit.
5. To configure the path where the LUN directory is created, in the To path box, type the
full path of the directory, or click Browse to select the directory. If a path is not
specified, the LUN directory is unchanged from the original directory where that LUN
was created.
6. Click Submit.
iSCSI
Modify an iSCSI LUN
419
Import an iSCSI LUN
You can recreate logical units that were replicated to a remote cluster or that were backed
up and then restored to a remote cluster.
The iSCSI module does not support replicating or restoring logical unit snapshots or clone
copies.
Procedure
1. Click File System Management
iSCSI
Targets & Logical Units.
2. In the Logical Units area, click Import logical unit.
3. In the Description field, type a descriptive comment for the logical unit.
4. In the Source path field, type the full path (beginning with /ifs) of the directory that
contains the logical unit that you want to import, or click Browse to select the
directory.
5. From the Target list, select the target that will contain the logical unit.
6. Select one of the LUN number options.
l
To assign the next available number to the logical unit, click Automatic. This is the
default setting.
l
To manually assign a number to the logical unit, click Manual, and then in the
Number field, type an integer value. The value must be within the range 0-255 and
must not be assigned to another logical unit.
7. Select one of the LUN access options.
l
To make the LUN accessible, click Online. This is the default setting.
l
To make the LUN inaccessible, click Offline.
8. Select one of the Write access options.
l
To allow iSCSI initiators to write to the LUN, click Read-Write. This is the default
setting.
l
To prevent iSCSI initiators from writing to the LUN, click Read-Only.
9. Select one of the caching options.
l
To allow write caching for files storing LUN data, click Enabled.
l
To prevent write caching for files storing LUN data, click Disabled.
10.Click Submit.
View iSCSI LUN settings
You can view information about a logical unit, including its logical unit number (LUN),
iSCSI target, LUN type, LUN directory path, iSCSI qualified name, and other settings.
Procedure
1. Click File System Management 
iSCSI
Targets & Logical Units.
2. In the Logical Units area, under Target:LUN, click the name of the logical unit that you
want to view.
3. The following settings display:
l
LUN: Displays the numerical identifier of the logical unit. You can modify the LUN
value by using the move operation.
iSCSI
420
OneFS
7.1 
Web Administration Guide
Documents you may be interested
Documents you may be interested