After you download and save the appropriate MIBs, you can configure SNMP monitoring
through either the web administration interface or though the command-line interface.
Configure the cluster for SNMP monitoring
You can configure your EMC Isilon cluster to remotely monitor hardware components
using SNMP.
Before you begin
When SNMP v3 is used, OneFS requires the SNMP-specific security level of AuthNoPriv as
the default value when querying the cluster. The security level AuthPriv is not supported.
You can enable or disable SNMP monitoring, allow SNMP access by version, and
configure other settings, some of which are optional. All SNMP access is read-only.
Note
The Isilon cluster does not generate SNMP traps unless you configure an event
notification rule to send events.
Procedure
1. Click Cluster Management 
General Settings
SNMP Monitoring.
2. In the Service area of the SNMP Monitoring page, enable or disable SNMP monitoring.
a. To disable SNMP monitoring, click Disable, and then click Submit.
b. To enable SNMP monitoring, click Enable, and then continue with the following
steps to configure your settings.
3. In the Downloads area, click Download for the MIB file that you want to download.
Follow the download process that is specific to your browser.
4. Optional: If you are using Internet Explorer as your browser, right-click the Download
link, select Save As from the menu, and save the file to your local drive.
You can save the text in the file format that is specific to your Net-SNMP tool.
5. Copy MIB files to a directory where your SNMP tool can find them, such as /usr/
share/snmp/mibs/ or /usr/local/share/snmp/mibs, depending on the
SNMP tool that you use.
To have Net-SNMP tools read the MIBs to provide automatic name-to-OID mapping,
add -m All to the command, as in the following example: snmpwalk -v2c -c
public -m All <node IP> isilon
6. Navigate back to the SNMP Monitoring page and configure General Settings.
a. In the Settings area, configure protocol access by selecting the version that you
want.
OneFS does not support writable OIDs; therefore, no write-only community string
setting is available.
b. In the System location field, type the system name.
This setting is the value that the node reports when responding to queries. Type a
name that helps to identify the location of the node.
c. Type the contact email address in the System contact field.
7. Optional: If you selected SNMP v1/v2 as your protocol, locate the SNMP v1/v2c
Settings section and type the community name in the Read-only community field.
General cluster administration
SNMP monitoring
61
Convert pdf to jpg file - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf to jpg 300 dpi; best program to convert pdf to jpg
Convert pdf to jpg file - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
change file from pdf to jpg on; change file from pdf to jpg
8. Configure SNMP v3 Settings.
a. In the Read-only user field, type the SNMP v3 security name to change the name of
the user with read-only privileges.
The default read-only user is general.
The password must contain at least eight characters and no spaces.
b. in the SNMP v3 password field, type the new password for the read-only user to
set a new SNMP v3 authentication password.
The default password is password.
c. Type the new password in the Confirm password field to confirm the new
password.
9. Click Submit.
View SNMP settings
You can review SNMP monitoring settings.
Procedure
1. Click Cluster Management 
General Settings
SNMP Monitoring.
Cluster maintenance
Trained service personnel can replace or upgrade components in Isilon nodes.
Isilon Technical Support can assist you with replacing node components or upgrading
components to increase performance.
Replacing node components
If a node component fails, Isilon Technical Support will work with you to quickly replace
the component and return the node to a healthy status.
Trained service personnel can replace the following field replaceable units (FRUs):
u
battery
u
boot flash drive
u
SATA/SAS Drive
u
memory (DIMM)
u
fan
u
front panel
u
intrusion switch
u
network interface card (NIC)
u
IB/NVRAM card
u
SAS controller
u
NVRAM battery
u
power supply
If you configure your cluster to send alerts to Isilon, Isilon Technical Support will contact
you if a component needs to be replaced. If you do not configure your cluster to send
alerts to Isilon, you must initiate a service request.
General cluster administration
62
OneFS
7.1 
Web Administration Guide
Online Convert Jpeg to PDF file. Best free online export Jpg image
Convert a JPG to PDF. You can drag and drop your JPG file in the box, and then start immediately to sort the files, try out some settings and then create the
convert pdf photo to jpg; best way to convert pdf to jpg
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
convert from pdf to jpg; convert pdf page to jpg
Upgrading node components
You can upgrade node components to gain additional capacity or performance.
Trained service personnel can upgrade the following components in the field:
u
drive
u
memory (DIMM)
u
network interface card (NIC)
If you want to upgrade components in your nodes, contact Isilon Technical Support.
Managing cluster nodes
You can add and remove nodes from a cluster. You can also shut down or restart the
entire cluster.
Add a node to a cluster
You can add a new node to an existing EMC Isilon cluster.
Before you begin
Before you add a node to a cluster, verify that an internal IP address is available. Add IP
addresses as necessary before you add a new node.
If a new node is running a different version of OneFS than a cluster, the system changes
the node version of OneFS to match the cluster.
Procedure
1. Click Cluster Management
Hardware Configuration
Add Nodes.
2. In the Available Nodes table, click Add for the node that you want to add to the
cluster.
Remove a node from the cluster
You can remove a node from an EMC Isilon cluster. When you remove a node, the system
smartfails the node to ensure that data on the node is transferred to other nodes in the
cluster.
Removing a storage node from a cluster deletes the data from that node. Before the
system deletes the data, the FlexProtect job safely redistributes data across the nodes
remaining in the cluster.
Procedure
1. Navigate to Cluster Management
Hardware Configuration
Remove Nodes.
2. In the Remove Node area, specify the node you want to remove.
3. Click Submit.
If you remove a storage node, the Cluster Status area displays smartfail progress. If
you remove a non-storage accelerator node, it is immediately removed from the
cluster.
General cluster administration
Upgrading node components
63
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# sample code for PDF to jpg image conversion. This demo code convert PDF file all pages to jpg images. // Define input and output files path.
convert pdf image to jpg; convert pdf image to jpg image
C# Image Convert: How to Convert Dicom Image File to Raster Images
RasterEdge.XDoc.Office.Inner.Office03.dll. RasterEdge.XDoc.PDF.dll. RasterEdge.XDoc. PowerPoint.dll. This demo code convert dicom file all pages to jpg images.
bulk pdf to jpg converter; convert pdf file to jpg on
Shut down or restart a cluster
You can shut down or restart an entire EMC Isilon cluster.
Procedure
1. Navigate to Cluster Management
Hardware Configuration
Shutdown & Reboot
Controls.
2. In the Shut Down or Reboot This Cluster area, specify an action:
Options
Description
Shut down
Shuts down the cluster.
Reboot
Stops then restarts the cluster.
3. Click Submit.
Remote support using SupportIQ
Isilon Technical Support personnel can remotely manage your Isilon cluster to
troubleshoot an open support case with your permission. The Isilon SupportIQ module
allows Isilon Technical Support personnel to gather diagnostic data about the cluster.
Isilon Technical Support representatives run scripts that gather data about cluster
settings and operations. The SupportIQ agent then uploads the information to a secure
Isilon FTP site so it is available for Isilon Technical Support personnel to review. These
scripts do not affect cluster services or data availability.
Note
The SupportIQ scripts are based on the Isilon isi_gather_info log-gathering tool.
The SupportIQ module is included with the OneFS operating system and does not require
you to activate a separate license. You must enable and configure the SupportIQ module
before SupportIQ can run scripts to gather data. The feature may have been enabled
when the cluster was first set up, but you can enable or disable SupportIQ through the
Isilon web administration interface.
In addition to enabling the SupportIQ module to allow the SupportIQ agent to run scripts,
you can enable remote access, which allows Isilon Technical Support personnel to
monitor cluster events and remotely manage your cluster using SSH or the web
administration interface. Remote access helps Isilon Technical Support to quickly identify
and troubleshoot cluster issues. Other diagnostic tools are available for you to use in
conjunction with Isilon Technical Support to gather and upload information such as
packet capture metrics.
Note
If you enable remote access, you must also share cluster login credentials with Isilon
Technical Support personnel. Isilon Technical Support personnel remotely access your
cluster only in the context of an open support case and only after receiving your
permission.
General cluster administration
64
OneFS
7.1 
Web Administration Guide
C# Create PDF from images Library to convert Jpeg, png images to
C# Create PDF from Raster Images, .NET Graphics and REImage File with XDoc Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp
change pdf to jpg file; convert pdf to jpg for online
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Turn multipage PDF file into image files in .NET WinForm application. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET.
changing file from pdf to jpg; convert pdf pages to jpg online
Configuring SupportIQ
OneFS logs contain data that Isilon Technical Support personnel can securely upload,
with your permission, and then analyze to troubleshoot cluster problems. The SupportIQ
technology must be enabled and configured for this process.
When SupportIQ is enabled, Isilon Technical Support personnel can request logs through
scripts that gather cluster data and then upload the data to a secure location. You must
enable and configure the SupportIQ module before SupportIQ can run scripts to gather
data. The feature may have been enabled when the cluster was first set up.
You can also enable remote access, which allows Isilon Technical Support personnel to
troubleshoot your cluster remotely and run additional data-gathering scripts. Remote
access is disabled by default. To enable remote SSH access to your cluster, you must
provide the cluster password to a Technical Support engineer.
Enable and configure SupportIQ
You can enable and configure SupportIQ to allow the SupportIQ agent to run scripts that
gather and upload information about your cluster to Isilon Technical Support personnel.
Optionally, you can enable remote access to your EMC Isilon cluster.
Procedure
1. Click Cluster Management 
General Settings
SupportIQ.
2. In the SupportIQ Settings area, select the Enable SupportIQ check box.
3. For SupportIQ alerts, select an option.
l
Send alerts via SupportIQ agent (HTTPS) and by email (SMTP) – SupportIQ
delivers notifications to Isilon through the SupportIQ agent over HTTPS and by
email over SMTP.
l
Send alerts via SupportIQ agent (HTTPS) – SupportIQ delivers notifications to
Isilon only through the SupportIQ agent over HTTPS.
4. Optional: Enable HTTPS proxy support for SupportIQ.
a. Select the HTTPS proxy for SupportIQ check box.
b. In the Proxy host field, type the IP address or fully qualified domain name (FQDN)
of the HTTP proxy server.
c. In the Proxy port field, type the number of the port on which the HTTP proxy server
receives requests.
d. Optional: In the Username field, type the user name for the proxy server.
e. Optional: In the Password field, type the password for the proxy server.
5. Optional: Enable remote access to the cluster.
a. Select the Enable remote access to cluster via SSH and web interface check box.
b. Review the remote-access end user license agreement (EULA) and, if you agree to
the terms and conditions, select the I have read and agree to check box.
6. Click Submit.
A successful configuration is indicated by a message similar to SupportIQ
settings have been updated.
General cluster administration
Configuring SupportIQ
65
C# WPF PDF Viewer SDK to convert and export PDF document to other
Convert PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and GIF. C#.NET WPF PDF Viewer Tool: Convert and Export PDF.
convert pdf to jpeg; best pdf to jpg converter online
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
Use C# Code to Convert Jpeg to Tiff. jpg", @"C:\demo2.jpg", @"C:\demo3.jpg" }; // Construct List foreach (string file in imagePaths) { Bitmap tmpBmp = new Bitmap
convert .pdf to .jpg; c# convert pdf to jpg
Disable SupportIQ
You can disable SupportIQ so the SupportIQ agent does not run scripts to gather and
upload data about your EMC Isilon cluster.
Procedure
1. Click Cluster Management 
General Settings
SupportIQ.
2. Clear the Enable SupportIQ check box.
3. Click Submit.
SupportIQ scripts
When SupportIQ is enabled, Isilon Technical Support personnel can request logs with
scripts that gather cluster data and then upload the data. The SupportIQ scripts are
located in the /usr/local/SupportIQ/Scripts/ directory on each node.
Data-gathering scripts
The following table lists the data-gathering activities that SupportIQ scripts perform.
These scripts can be run automatically, at the request of an Isilon Technical Support
representative, to collect information about your cluster's configuration settings and
operations. The SupportIQ agent then uploads the information to a secure Isilon FTP site,
so that it is available for Isilon Technical Support personnel to analyze. The SupportIQ
scripts do not affect cluster services or the availability of your data.
Action
Description
-
-
Clean watch folder
Clears the contents of /var/crash.
Get application data
Collects and uploads information about OneFS application
programs.
Generate dashboard file
daily
Generates daily dashboard information.
Generate dashboard file
sequence
Generates dashboard information in the sequence that it occurred.
Get ABR data (as built
record)
Collects as-built information about hardware.
Get ATA control and GMirror
status
Collects system output and invokes a script when it receives an
event that corresponds to a predetermined 
eventid
.
Get cluster data
Collects and uploads information about overall cluster
configuration and operations.
Get cluster events
Gets the output of existing critical events and uploads the
information.
Get cluster status
Collects and uploads cluster status details.
Get contact info
Extracts contact information and uploads a text file that contains
it.
Get contents (var/crash)
Uploads the contents of /var/crash.
General cluster administration
66
OneFS
7.1 
Web Administration Guide
Action
Description
-
-
Get job status
Collects and uploads details on a job that is being monitored.
Get domain data
Collects and uploads information about the cluster’s Active
Directory Services (ADS) domain membership.
Get file system data
Collects and uploads information about the state and health of the
OneFS /ifs/ file system.
Get IB data
Collects and uploads information about the configuration and
operation of the InfiniBand back-end network.
Get logs data
Collects and uploads only the most recent cluster log information.
Get messages
Collects and uploads active /var/log/messages files.
Get network data
Collects and uploads information about cluster-wide and node-
specific network configuration settings and operations.
Get NFS clients
Runs a command to check if nodes are being used as NFS clients.
Get node data
Collects and uploads node-specific configuration, status, and
operational information.
Get protocol data
Collects and uploads network status information and configuration
settings for the NFS, SMB, FTP, and HTTP protocols.
Get Pcap client stats
Collects and uploads client statistics.
Get readonly status
Warns if the chassis is open and uploads a text file of the event
information.
Get usage data
Collects and uploads current and historical information about
node performance and resource usage.
isi_gather_info
Collects and uploads all recent cluster log information.
isi_gather_info --
incremental
Collects and uploads changes to cluster log information that have
occurred since the most recent full operation.
isi_gather_info --
incremental single
node
Collects and uploads details for a single node.
Prompts you for the node number.
isi_gather_info
single node
Collects and uploads changes to cluster log information that have
occurred since the most recent full operation.
Prompts you for the node number.
Upload the dashboard file
Uploads dashboard information to the secure Isilon Technical
Support FTP site.
General cluster administration
SupportIQ scripts
67
Upgrading OneFS
Two options are available for upgrading the OneFS operating system: a rolling upgrade or
a simultaneous upgrade. Before upgrading OneFS softare, a pre-upgrade check must be
performed.
A rolling upgrade individually upgrades and restarts each node in the cluster
sequentially. During a rolling upgrade, the cluster remains online and continues serving
clients with no interruption in service, although some connection resets may occur on
SMB clients. Rolling upgrades are performed sequentially by node number, so a rolling
upgrade takes longer to complete than a simultaneous upgrade. The final node in the
upgrade process is the node that you used to start the upgrade process.
Note
Rolling upgrades are not available for all clusters. For instructions on how to upgrade the
cluster operating system, see the OneFS Release Notes.
A simultaneous upgrade installs the new operating system and restarts all nodes in the
cluster at the same time. Simultaneous upgrades are faster than rolling upgrades but
require a temporary interruption of service during the upgrade process. Your data is
inaccessible during the time that it takes to complete the upgrade process.
Before beginning either a simultaneous or rolling upgrade, OneFS compares the current
cluster and operating system with the new version to ensure that the cluster meets
certain criteria, such as configuration compatibility (SMB, LDAP, SmartPools), disk
availability, and the absence of critical cluster events. If upgrading puts the cluster at
risk, OneFS warns you, provides information about the risks, and prompts you to confirm
whether to continue the upgrade.
If the cluster does not meet the pre-upgrade criteria, the upgrade does not proceed, and
the unsupported statuses are listed.
General cluster administration
68
OneFS
7.1 
Web Administration Guide
CHAPTER 4
Access zones
This section contains the following topics:
u
Access zones overview..........................................................................................70
u
Access zone features.............................................................................................70
u
Managing access zones........................................................................................71
Access zones
69
Access zones overview
You can use access zones to partition cluster configuration into self-contained units.
Access zones provide the means for administrators to configure a subset of parameters
as a virtual cluster.
OneFS includes a built-in access zone named System that contains all configured
authentication providers, all available SMB shares, and all available NFS exports. You
can add additional access zones to the cluster as needed. By default, all cluster IP
addresses connect to the System zone. The System zone is used by administrators for
managing all access zone configuration tasks.
Access zones contain all of the necessary configuration settings to support
authentication and identity management services in OneFS. NFS exports are added to the
System zone, but you can configure authentication providers and SMB shares on a zone-
by-zone basis. You also can use access zones to partition access to data through IP-
address pools. When you configure access zones in this manner, incoming connections
can be directed to an access zone by a specific IP address within a pool. his restricts
authentication to that zone and reduces the available SMB shares that can be accessed.
Note
Role-based access, which primarily handles configuration actions, is available through
only the System zone.
Access zone features
You can configure access zones to leverage the following features for your environment.
Feature
Description
Comment
-
-
-
Overlapping
share-name
support
If multiple SMB share have the
same display name, OneFS
supports the overlapping display
names if the name appears only
once per access zone.
For example, you can assign the name
"home" as the display name for a share
in zone A and a different share in zone
B.
Multiple access
zone support
You can create additional access
zones and configure each zone
differently. Each access zone can
be configured with its own set of
authentication providers, user
mapping rules, and SMB shares.
Multiple access zones are particularly
useful for server consolidation, for
example when merging multiple
Windows file servers that are
potentially joined to different untrusted
forests.
Note
NFS users can be authenticated against
only the System zone.
SMB-protocol
access auditing
on individual
access zones
You can audit SMB-protocol access
on individual access zones.
For audited zones, you can modify the
default list of successful and failed
protocol events that are audited.
Access zones
70
OneFS
7.1 
Web Administration Guide
Documents you may be interested