Programming Examples
LAN Programming Interface Examples
if displayCorr~=0
fcorr = fftshift(fft(resampledTime));
displayOversample = 100;
xcoordsOversample = 
((1:(displayOversample*length(fcorr)))-(displayOversample*length(fcorr)+2)/2)/(length(fcorr))*destR
ate/displayOversample;
% plot amplitude correction
figure;plot(xcoordsOversample, resample(20*log10(abs(fcorr)),displayOversample,1,100));
% plot phase correction
fcorrz = fftshift(fft(ifftshift(resampledTime)));
figure;plot(xcoordsOversample, resample(unwrap(angle(fcorrz)),displayOversample,1,100)/pi*180);
end
% clip off the center 256 (if necessary)
if (length(resampledTime)>256)
[~, index] = max(abs(resampledTime));
center=index;
left = center-127;
right = left+255;
clippedTime=resampledTime((left):(right));
else
clippedTime = resampledTime;
end
corrFilter=clippedTime;
end
function array = readArrayOfDoubles(fid)
line = fgets(fid);
array = sscanf(line, '%g%*c');
end
Example 3: Reading a VSA Trace and Setting up the Equalization Filter Using Matlab 
NOTE
For X-Series signal generators (N5172B/82B), replace the 125MHz value with 200MHz.
This example reads a VSA trace of “Eq Ch Freq Resp” or “Eq Impls Resp” and creates an equalization 
filter compatible with the MXG.
The following program Matlab example is available on the signal generator Documentation CD-ROM 
as loadVsaEQFilterFreq.m.
function [corrFilter] = loadVsaEqFilter(filename, destRate)
% [corrFilter] = loadVsaFilter(filename[, destRate])
% filename must reference an 89600 Equalization filter saved as .mat file with the header included.
% destRate is assumed to be 125e6 if missing
Change format from pdf to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf to jpg c#; best way to convert pdf to jpg
Change format from pdf to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
.pdf to jpg; changing file from pdf to jpg
154
Agilent Signal Generators Programming Guide
Programming Examples
LAN Programming Interface Examples
% output of corrFilter is in time domain.
% Typically followed with:
 writeMxgFir('a-n5182a-00211', 'cft', corrFilter);
if (nargin<1 || nargin>2)
error('[corrFilter] = loadVsaEqFilter(filename[, destRate]) -- destRate is assumed to be 125e6 if 
missing');
end
if (nargin<2)
destRate=125e6;
end
% load filter struct from .mat file
filterStruct=load(filename);
coeffs = double(filterStruct.Y);
if (filterStruct.XDomain==1) % frequency
rate = filterStruct.XDelta*length(coeffs); % frequency range is also rate
% VSA software supplies centered frequency domain
else % time domain is 2
rate = 1/filterStruct.XDelta; % inverse of time step is frequency
% convert to frequency domain
% must center frequency domain (to match what comes from the VSA
% software)
coeffs = fftshift(fft(coeffs));
end
% invert
invertedFreqDomain = 1./coeffs;
% convert to time domain (first placing the 0 frequency at the left edge)
timeDomain=ifft(ifftshift(invertedFreqDomain));
if (filterStruct.XDomain==1) % frequency
% put time domain 0 time in center
len=length(timeDomain);
if (mod(length(timeDomain), 2)==1) % odd
center=ceil(len/2);
centeredTime(1:(center-1)) = timeDomain(center+1:end);
centeredTime(center:len) = timeDomain(1:center);
else % even
topHalf = (length(timeDomain)/2)+1;
centeredTime(1:(topHalf-1)) = timeDomain(topHalf:end);
centeredTime(topHalf:len) = timeDomain(1:(topHalf-1));
end
else % already centered in time domain
centeredTime = timeDomain;
end
if (abs(destRate-rate)>1e-6)
Online Convert Jpeg to PDF file. Best free online export Jpg image
try out some settings and then create the PDF files with the button at the bottom. The perfect conversion tool. JPG is the most widely used image format, but we
change pdf file to jpg; convert pdf page to jpg
C# PDF Convert to Images SDK: Convert PDF to png, gif images in C#
You can also directly change PDF to Gif image file in C# program. // Load a PDF file. Description: Convert all the PDF pages to target format images and
c# pdf to jpg; convert multipage pdf to jpg
Agilent Signal Generators Programming Guide
155
Programming Examples
LAN Programming Interface Examples
resampledTime = resample(centeredTime, destRate, rate, 30);
resampledTime = resampledTime.*(rate/destRate);
else
resampledTime = centeredTime;
end
% clip off the center 256 (if necessary)
if (length(resampledTime)>256)
[maxval, index] = max(abs(resampledTime));
center=index;
left = center-127;
right = left+255;
clippedTime=resampledTime((left):(right));
else
clippedTime = resampledTime;
end
corrFilter=clippedTime;
end
Example 4: Downloading a FIR filter in Matlab to the MXG
NOTE
For X-Series signal generators (N5172B/82B), replace the 125MHz value with 200MHz.
This example uses Matlab to control the MXG over the TCP-IP (LAN) interface. This example takes a 
filter in Matlab and writes it to a FIR file in the MXG. This example can be can be used in 
combination with either the automatable loadPsaEqFilterFreq.m example (1) or the loadVsaEqFilter.m 
(example 3) to manually work with the VSA 89600 software. This example can also be used to create 
real modulation FIRs. 
The following program example is available on the signal generator Documentation CD-ROM as 
writeMxgFir.m.
function [rateAdjustedFilter]=writeMxgFir(host, instrumentFilename, timeDomainFilter, osr, rate, 
destRate, maxTaps)
% writeMxgEqFir(host, instrumentFilename, timeDomainFilter, osr, rate, destRate, maxTaps);
% writes filter to 'instrumentFilename' on 'host' using tcp-ip. Real or complex is
% auto-detected.  osr is assumed to be 1 if it is missing.  rate is assumed
% to be 125Mhz if missing.  destRate is assumed to be 125Mhz if missing.
% maxTaps is the hardware limit of the MXG (256 if not specified).
% This value should be 256 for the Equalization filter and 32*osr for the
% Arb Modulation filter.  Note that the filter has a rectangular window
% applied with a width of maxTaps centered about the peak point.
% Example: writeMxgEqFir('mxg1', 'a', [-0.1 0.1 0.4 0.1 0.4 0.1 -0.1]);
if (nargin<3 || nargin>7)
error('usage: writeMxgFir(host, instrumentFilename, timeDomainFilter[, osr[, rate[, destRate[, 
Online Convert PDF to Jpeg images. Best free online PDF JPEG
JPG is the most common image format on the internet. The outputs of our conversion service are always JPG files to even if pictures are saved in a PDF in other
convert pdf pages to jpg; conversion pdf to jpg
JPEG Image Viewer| What is JPEG
JPEG, JPG. enabling you to quickly convert your JPEG images into other file formats, including Bitmap, Png, Gif, Tiff, PDF, MS-Word, etc More Format Information.
convert pdf file to jpg online; batch pdf to jpg
156
Agilent Signal Generators Programming Guide
Programming Examples
LAN Programming Interface Examples
maxTaps]]]])');
end
if (nargin<4)
osr=1;
end
if (nargin<5)
rate=125e6;
end
if (nargin<6)
destRate=125e6;
end
if (nargin<7)
maxTaps=1024;
end
% adjust coefficients for destination rate
if (rate ~= destRate)
timeDomainFilter = resample(double(timeDomainFilter), destRate, rate, 30);
timeDomainFilter = timeDomainFilter.*(rate/destRate);
end
if (length(timeDomainFilter)>maxTaps)
[maxval, index] = max(abs(timeDomainFilter));
center=index;
left = center-(maxTaps/2-1);
if (left<1)
left=1;
end
right = left+(maxTaps-1);
while (right > length(timeDomainFilter))
right = right-1;
end
timeDomainFilter = timeDomainFilter((left):(right));
end
rateAdjustedFilter = timeDomainFilter;
% open tcp connection
t=tcpip(host, 5025);
t.OutputBufferSize=1024*1024; % plenty big for filters
% write file contents
fopen(t);
%for writing to a file instead to see what is being output
%t=fopen('test', 'w');
% send command with filename
fprintf(t, '%s', horzcat(':MEM:DATA:FIR "', instrumentFilename, '",'));
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff If you want to turn PDF file into image file format in C#
change format from pdf to jpg; convert pdf to jpg file
C# Image: How to Download Image from URL in C# Project with .NET
If you want other format, you can use the image you can also save a gif, jpeg / jpg, or bmp provide powerful & profession imaging controls, PDF document, tiff
convert from pdf to jpg; batch convert pdf to jpg
Agilent Signal Generators Programming Guide
157
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
% send type
if (isreal(timeDomainFilter))
fprintf(t, '%s', 'REAL,');
else % convert complex to a real array
fprintf(t, '%s', 'COMP,');
temp=zeros(1,length(timeDomainFilter)*2);
temp(1:2:end)=real(timeDomainFilter);
temp(2:2:end)=imag(timeDomainFilter);
timeDomainFilter=temp;
end
% output osr
fprintf(t, '%d', osr);
% send coefficients
fprintf(t, ',%g', timeDomainFilter);
% send terminator
fprintf(t, '\n');
fclose(t);
end
RS-232 Programming Interface Examples (ESG/PSG Only)
• “Interface Check Using HP BASIC” on page 157
• “Interface Check Using VISA and C” on page 158
• “Queries Using HP Basic and RS-232” on page 160
• “Queries for RS-232 Using VISA and C” on page 162
Before Using the Examples
Before using the examples: On the signal generator select the following settings:
• Baud Rate - 9600 must match computer’s baud rate
• RS-232 Echo - Off
Use an RS-232 cable, that is compatible with Table 2-2 on page 66.
Interface Check Using HP BASIC 
This example program causes the signal generator to perform an instrument reset. The SCPI 
command *RST will place the signal generator into a pre-defined state. 
The serial interface address for the signal generator in this example is 9. The serial port used is 
COM1 (Serial A on some computers). Refer to “Using RS–232 (ESG and PSG Only)” on page 63 for 
more information.
Watch for the signal generator’s Listen annunciator (L) and the ‘remote preset....’ message on the 
front panel display. If there is no indication, check that the RS-232 cable is properly connected to 
the computer serial port and that the manual setup listed above is correct.
If the compiler displays an error message, or the program hangs, it is possible that the program was 
typed incorrectly. Press the signal generator’s Reset RS-232 softkey and re-run the program. Refer to 
VB.NET Word: Word to JPEG Image Converter in .NET Application
Word doc into high quality jpeg / jpg images; Convert a be converted into Jpeg image format and then powerful & profession imaging controls, PDF document, image
pdf to jpeg; changing pdf to jpg on
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
Powerful .NET control to batch convert PDF documents to tiff format in Visual C# .NET program. Also supports convert PDF files to jpg, jpeg images.
convert online pdf to jpg; convert pdf picture to jpg
158
Agilent Signal Generators Programming Guide
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
“If You Have Problems” on page 68 for more help.
The following program example is available on the signal generator’s Documentation CD-ROM as 
rs232ex1.txt.
10    !******************************************************************************
20    !
30    !  PROGRAM NAME:         rs232ex1.txt 
40    !
50    !  PROGRAM DESCRIPTION:  This program verifies that the RS-232 connections and
60    !                        interface are functional.
70    !
80    !  Connect the UNIX workstation to the signal generator using an RS-232 cable
90    ! 
100   !
110   !  Run HP BASIC, type in the following commands and then RUN the program
120   !
130   !
140   !******************************************************************************
150   !
160    INTEGER Num
170    CONTROL 9,0;1       ! Resets the RS-232 interface
180    CONTROL 9,3;9600    ! Sets the baud rate to match the sig gen
190    STATUS 9,4;Stat     ! Reads the value of register 4
200    Num=BINAND(Stat,7)  ! Gets the AND value
210    CONTROL 9,4;Num     ! Sets parity to NONE
220    OUTPUT 9;"*RST"     ! Outputs reset to the sig gen
230    END                 ! End the program
Interface Check Using VISA and C
This program uses VISA library functions to communicate with the signal generator. The program 
verifies that the RS-232 connections and interface are functional. In this example the COM2 port is 
used. The serial port is referred to in the VISA library as ‘ASRL1’ or ‘ASRL2’ depending on the 
computer serial port you are using. Launch Microsoft Visual C++, add the required files, and enter 
the following code into the .cpp source file. rs232ex1.cpp performs the following functions:
• prompts the user to set the power on the signal generator to 0 dBm
• error checking
• resets the signal generator to power level of –135 dBm
The following program example is available on the signal generator Documentation CD-ROM as 
rs232ex1.cpp.
//****************************************************************************************
// PROGRAM NAME:        rs232ex1.cpp
// 
// PROGRAM DESCRIPTION: This code example uses the RS-232 serial interface to
VB.NET Image: How to Create Visual Basic .NET Windows Image Viewer
If you need a format conversion, it is also available including png, jpeg, gif, tiff, bmp, PDF, and Word from that, you are entitled to change the orientation
convert pdf images to jpg; .net convert pdf to jpg
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
Split PDF Document; Remove Password from PDF; Change PDF Permission Settings. Export PDF to TIFF file format. Convert PDF to image formats, such as PNG, JPG, BMP
pdf to jpeg converter; change pdf to jpg online
Agilent Signal Generators Programming Guide
159
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
// control the signal generator. 
// 
// Connect the computer to the signal generator using an RS-232 serial cable.
// The user is asked to set the signal generator for a 0 dBm power level
// A reset command *RST is sent to the signal generator via the RS-232
// interface and the power level will reset to the -135 dBm level.The default
// attributes e.g. 9600 baud, no parity, 8 data bits,1 stop bit are used.
// These attributes can be changed using VISA functions. 
//
// IMPORTANT: Set the signal generator BAUD rate to 9600 for this test
//**************************************************************************************** 
#include <visa.h>
#include <stdio.h>
#include "StdAfx.h"
#include <stdlib.h>
#include <conio.h>
void main ()
{
int baud=9600;// Set baud rate to 9600
printf("Manually set the signal generator power level to 0 dBm\n");
printf("\n");
printf("Press any key to continue\n");
getch();
printf("\n");
ViSession defaultRM, vi;// Declares a variable of type ViSession
// for instrument communication on COM 2 port
ViStatus viStatus = 0;   
// Opens session to RS-232 device at serial port 2
viStatus=viOpenDefaultRM(&defaultRM);
viStatus=viOpen(defaultRM, "ASRL2::INSTR", VI_NULL, VI_NULL, &vi);
if(viStatus){// If operation fails, prompt user
printf("Could not open ViSession!\n");
printf("Check instruments and connections\n");
printf("\n");
exit(0);}
// initialize device
160
Agilent Signal Generators Programming Guide
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
viStatus=viEnableEvent(vi, VI_EVENT_IO_COMPLETION, VI_QUEUE,VI_NULL);
viClear(vi);// Sends device clear command
// Set attributes for the session
viSetAttribute(vi,VI_ATTR_ASRL_BAUD,baud); 
viSetAttribute(vi,VI_ATTR_ASRL_DATA_BITS,8);
viPrintf(vi, "*RST\n");// Resets the signal generator
printf("The signal generator has been reset\n");
printf("Power level should be -135 dBm\n");
printf("\n");// Prints new line character to the display
viClose(vi);// Closes session
viClose(defaultRM);// Closes default session
}
Queries Using HP Basic and RS-232
This example program demonstrates signal generator query commands over RS-232. Query commands 
are of the type *IDN? and are identified by the question mark that follows the mnemonic. 
rs232ex2.txt performs the following functions:
• resets the RS-232 interface
• sets the baud rate to match the signal generator rate
• reads the value of register 4
• queries the signal generator ID
• sets and queries the power level
Start HP Basic, type in the following commands, and then RUN the program: 
The following program example is available on the signal generator Documentation CD-ROM as 
rs232ex2.txt.
10    !********************************************************************************
20    !
30    !  PROGRAM NAME:         rs232ex2.txt
40    !
50    !  PROGRAM DESCRIPTION:  In this example, query commands are used to read
60    !                        data from the signal generator.
70    !
80    !  Start HP Basic, type in the following code and then RUN the program.
90    !
100   !********************************************************************************
110   !
120    INTEGER Num
130    DIM Str$[200],Str1$[20]
140    CONTROL 9,0;1              ! Resets the RS-232 interface
150    CONTROL 9,3;9600           ! Sets the baud rate to match signal generator rate
Agilent Signal Generators Programming Guide
161
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
160    STATUS 9,4;Stat            ! Reads the value of register 4
170    Num=BINAND(Stat,7)         ! Gets the AND value
180    CONTROL 9,4;Num            ! Sets the parity to NONE
190    OUTPUT 9;"*IDN?"           ! Querys the sig gen ID
200    ENTER 9;Str$               ! Reads the ID
210    WAIT 2                     ! Waits 2 seconds
220    PRINT "ID =",Str$          ! Prints ID to the screen
230    OUTPUT 9;"POW:AMPL -5 dbm" ! Sets the the power level to -5 dbm
240    OUTPUT 9;"POW?"            ! Querys the power level of the sig gen
250    ENTER 9;Str1$              ! Reads the queried value
260    PRINT "Power = ",Str1$     ! Prints the power level to the screen
270    END                        ! End the program
162
Agilent Signal Generators Programming Guide
Programming Examples
RS-232 Programming Interface Examples (ESG/PSG Only)
Queries for RS-232 Using VISA and C
This example uses VISA library functions to communicate with the signal generator. The program 
verifies that the RS-232 connections and interface are functional. Launch Microsoft Visual C++, add 
the required files, and enter the following code into your .cpp source file. rs232ex2.cpp performs 
the following functions:
• error checking
• reads the signal generator response
• flushes the read buffer
• queries the signal generator for power
• reads the signal generator power
The following program example is available on the signal generator Documentation CD-ROM as 
rs232ex2.cpp.
//************************************************************************************
// 
// PROGRAM NAME:       rs232ex2.cpp
// 
// PROGRAM DESCRIPTION: This code example uses the RS-232 serial interface to control
// the signal generator.
// 
// Connect the computer to the signal generator using the RS-232 serial cable
// and enter the following code into the project .cpp source file. 
// The program queries the signal generator ID string and sets and queries the power
// level. Query results are printed to the screen. The default attributes e.g. 9600 baud,
// parity, 8 data bits,1 stop bit are used. These attributes can be changed using VISA
// functions.
//
// IMPORTANT: Set the signal generator BAUD rate to 9600 for this test
//************************************************************************************ 