mvc export to pdf : Convert pdf pages to jpg Library SDK component .net asp.net html mvc E8251-9035520-part499

Agilent Signal Generators Programming Guide
193
Programming the Status Register System
Status Groups
Table 4-8 8 Data Questionable Condition Register Bits
Bit
Description
0, 1, 2
Unused. These bits are always set to 0.
3
Power (summary). This is a summary bit taken from the QUEStionable:POWer register. A 1 in this bit position 
indicates that one of the following may have happened: The ALC (Automatic Leveling Control) is unable to 
maintain a leveled RF output power (i.e., ALC is UNLEVELED), the reverse power protection circuit has been 
tripped. See the “Data Questionable Power Status Group” on page 195 for more information.
4
N5161A/62A/81A/82A/83A: ALC Heater Detector (COLD). A 1 in this bit position indicates that the ALC 
detector is cold.
E4428C/38C, E8257D/67D, and E8663B: Temperature (OVEN COLD). A 1 in this bit position indicates that 
the internal reference oscillator (reference oven) is cold.
5
Frequency (summary). This is a summary bit taken from the QUEStionable:FREQuency register. A 1 in this bit 
position indicates that one of the following may have happened: synthesizer PLL unlocked, 10 MHz reference 
VCO PLL unlocked, 1 GHz reference unlocked, sampler, YO loop unlocked or baseband 1 unlocked. For more 
information, see the “Data Questionable Frequency Status Group” on page 198.
6
Unused. This bit is always set to 0.
7
Modulation (summary). This is a summary bit taken from the QUEStionable:MODulation register. A 1 in this 
bit position indicates that one of the following may have happened: modulation source 1 underrange, 
modulation source 1 overrange, modulation source 2 underrange, modulation source 2 overrange, or modulation 
uncalibrated. See the “Data Questionable Modulation Status Group” on page 201 for more information.
8
ab
a.In the N5162A/82A, this bit applies only to the I/Q calibration. In the N5161A/81A/83A, this bit is unused and always set to 0.
b.In the E8257D, E8663B, and the E8663D, this bit applies only to the DCFM/DCM calibration.
Calibration (summary). This is a summary bit taken from the QUEStionable:CALibration register. A 1 in this 
bit position indicates that one of the following may have happened: an error has occurred in the DCFM/DCM 
zero calibration, or an error has occurred in the I/Q calibration. See the “Data Questionable Calibration Status 
Group” on page 204 for more information.
9
Self Test. A 1 in this bit position indicates that a self-test has failed during power-up. Reset this bit by cycling 
the signal generator’s line power. *CLS will not clear this bit.
10, 11
Unused. These bits are always set to 0.
12
c
c.In the N5161A/81A, N5162A/82A, N5183A, E4428C, E8257D, E8267D, E8663B, and the E8663D, this bit is always set to 0.
BERT (summary). This is a summary bit taken from the QUEStionable:BERT register. A 1 in this bit position 
indicates that one of the following occurred: no BCH/TCH synchronization, no data change, no clock input, 
PRBS not synchronized, demod/DSP unlocked, or demod unleveled. See the “Data Questionable BERT Status 
Group” on page 207 for more information.
13, 14
Unused. These bits are always set to 0.
15
Always 0.
Query:
STATus:QUEStionable:CONDition?
Response:
The decimal sum of the bits set to 1
Example:
The decimal value 520 is returned. The decimal sum = 512 (bit 9) + 8 (bit 3).
Convert pdf pages to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf into jpg format; convert pdf to jpg 300 dpi
Convert pdf pages to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
change pdf to jpg; best convert pdf to jpg
194
Agilent Signal Generators Programming Guide
Programming the Status Register System
Status Groups
Data Questionable Transition Filters (negative and positive)
The Data Questionable Transition Filters specify which type of bit state changes in the condition 
register set corresponding bits in the event register. Changes can be positive (0 to 1) or negative (1 
to 0).
Data Questionable Event Register
The Data Questionable Event Register latches transition events from the condition register as 
specified by the transition filters. Event registers are destructive read-only. Reading data from an 
event register clears the content of that register.
Data Questionable Event Enable Register
The Data Questionable Event Enable Register lets you choose which bits in the Data Questionable 
Event Register set the summary bit (bit 3 of the Status Byte Register) to 1.
Commands:
STATus:QUEStionable:NTRansition <value> (negative transition), or 
STATus:QUEStionable:PTRansition <value> (positive transition), where 
<value> is the sum of the decimal values of the bits you want to enable.
Queries:
STATus:QUEStionable:NTRansition?
STATus:QUEStionable:PTRansition?
Query:
STATus:QUEStionable[:EVENt]?
Command:
STATus:QUEStionable:ENABle <value> where <value> is the sum of the decimal values of the bits 
you want to enable.
Example:
Enable bit 9 and bit 3 so that whenever either of those bits are set to 1, the Data Questionable Status 
summary bit of the Status Byte Register is set to 1. Send the command STAT:QUES:ENAB 520 (512 + 
8). 
Query:
STATus:QUEStionable:ENABle?
Response:
Decimal value of the sum of the bits previously enabled with the STATus:QUEStionable:ENABle 
<value> command.
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# sample code for PDF to jpg image conversion. This demo code convert PDF file all pages to jpg images. // Define input and output files path.
convert pdf photo to jpg; convert pdf pictures to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.Office.Inner.Office03.dll. RasterEdge.XDoc.PDF.dll. This demo code convert TIFF file all pages to jpg images.
best pdf to jpg converter; change format from pdf to jpg
Agilent Signal Generators Programming Guide
195
Programming the Status Register System
Status Groups
Data Questionable Power Status Group
NOTE
Some of the bits in this status group do not apply to the E4428C, E8257D, E8267D, E8663B, 
E8663D, and the N5161A/62A/81A/82A/83A, and returns zero when queried. See Table 4-9 
on page 196 for more information.
The Data Questionable Power Status Group is used to determine the specific event that set bit 3 in 
the Data Questionable Condition Register. This group consists of the Data Questionable Power 
Condition Register, the Data Questionable Power Transition Filters (negative and positive), the Data 
Questionable Power Event Register, and the Data Questionable Power Event Enable Register
This is the named 
status register for 
the E4438C. 
However, not all 
signal generator 
models use all of 
the shown events 
(i.e. some use only 
a subset of the 
E4438C’s status 
registers).
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
c# convert pdf to jpg; change file from pdf to jpg
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Resize converted image files in VB.NET. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Embed PDF to image converter in viewer.
changing pdf to jpg; convert pdf file to jpg online
196
Agilent Signal Generators Programming Guide
Programming the Status Register System
Status Groups
Data Questionable Power Condition Register
The Data Questionable Power Condition Register continuously monitors the hardware and firmware 
status of the signal generator. Condition registers are read only.
Data Questionable Power Transition Filters (negative and positive)
The Data Questionable Power Transition Filters specify which type of bit state changes in the 
condition register set corresponding bits in the event register. Changes can be positive (0 to 1) or 
negative (1 to 0).
Data Questionable Power Event Register
The Data Questionable Power Event Register latches transition events from the condition register as 
specified by the transition filters. Event registers are destructive read-only. Reading data from an 
event register clears the content of that register.
Table 4-9 9 Data Questionable Power Condition Register Bits
Bit
Description
0
a
a.In the N5161A/62A/81A/82A with Option 506, the N5183A, and the E4428C/38C with Option 506, this bit is set to 0.
Reverse Power Protection Tripped. A 1 in this bit position indicates that the reverse power protection (RPP) circuit 
has been tripped. There is no output in this state. Any conditions that may have caused the problem should be 
corrected. Reset the RPP circuit by sending the remote SCPI command: OUTput:PROTection:CLEar. Resetting the RPP 
circuit bit, resets this bit to 0.
1
Unleveled. A 1 in this bit position indicates that the output leveling loop is unable to set the output power.
2
b
b.In the N5161A/62A/81A/82A/83A, E4428C, E8257D/67D, and E8663B, this bit is set to 0.
IQ Mod Overdrive. A 1 in this bit position indicates that the signal level into the IQ modulator is too high.
3
c
Lowband Detector Fault. A 1 in this bit position indicates that the lowband detector heater circuit has failed.
414
Unused. These bits are always set to 0.
15
Always 0.
Query:
STATus:QUEStionable:POWer:CONDition?
Response:
The decimal sum of the bits set to 1.
Commands:
STATus:QUEStionable:POWer:NTRansition <value> (negative transition), or 
STATus:QUEStionable:POWer:PTRansition <value> (positive transition), where 
<value> is the sum of the decimal values of the bits you want to enable.
Queries:
STATus:QUEStionable:POWer:NTRansition? STATus:QUEStionable:POWer:PTRansition? 
Query:
STATus:QUEStionable:POWer[:EVENt]?
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
Create multiple pages Tiff file from PDF document. Convert PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and GIF.
convert from pdf to jpg; convert pdf to jpg converter
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
Use C# Code to Convert Jpeg to Tiff. string[] imagePaths = { @"C:\demo1.jpg", @"C:\demo2.jpg", @"C:\demo3.jpg" }; // Construct List<REImage> object.
conversion pdf to jpg; convert pdf to jpg
Agilent Signal Generators Programming Guide
197
Programming the Status Register System
Status Groups
Data Questionable Power Event Enable Register
The Data Questionable Power Event Enable Register lets you choose which bits in the Data 
Questionable Power Event Register set the summary bit (bit 3 of the Data Questionable Condition 
Register) to 1.
Command:
STATus:QUEStionable:POWer:ENABle <value> where <value> is the sum of the decimal values of 
the bits you want to enable
Example:
Enable bit 3 and bit 2 so that whenever either of those bits are set to 1, the Data Questionable Power 
summary bit of the Data Questionable Condition Register is set to 1. Send the command 
STAT:QUES:POW:ENAB 520 (8 + 4). 
Query:
STATus:QUEStionable:POWer:ENABle?
Response:
Decimal value of the sum of the bits previously enabled with the 
STATus:QUEStionable:POWer:ENABle <value> command.
C# WPF PDF Viewer SDK to convert and export PDF document to other
Create multiple pages Tiff file from PDF document. Convert PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and GIF.
convert pdf picture to jpg; change pdf to jpg image
VB.NET Create PDF from images Library to convert Jpeg, png images
Components to batch convert PDF documents in Visual Basic .NET class. Support create PDF from multiple image formats in VB.NET, including Jpg, Png, Bmp, Gif
convert pdf into jpg online; pdf to jpg converter
198
Agilent Signal Generators Programming Guide
Programming the Status Register System
Status Groups
Data Questionable Frequency Status Group
NOTE
Some bits in this status group do not apply to the N5161A/62A/81A/82A/83A, E4428C, 
E8257D, E8663B, and the E8663D and returns zero when queried. See Table 4-10 on 
page 199 for more information.
The Data Questionable Frequency Status Group is used to determine the specific event that set bit 5 
in the Data Questionable Condition Register. This group consists of the Data Questionable Frequency 
Condition Register, the Data Questionable Frequency Transition Filters (negative and positive), the 
Data Questionable Frequency Event Register, and the Data Questionable Frequency Event Enable 
Register
This is the named 
status register for 
the E4438C. 
However, not all 
signal generator 
models use all of 
the shown events 
(i.e. some use only 
a subset of the 
E4438C’s status 
registers).
Agilent Signal Generators Programming Guide
199
Programming the Status Register System
Status Groups
Data Questionable Frequency Condition Register
The Data Questionable Frequency Condition Register continuously monitors the hardware and 
firmware status of the signal generator. Condition registers are read-only.
Data Questionable Frequency Transition Filters (negative and positive)
Specifies which types of bit state changes in the condition register set corresponding bits in the event 
register. Changes can be positive (0 to 1) or negative (1 to 0).
Data Questionable Frequency Event Register
Latches transition events from the condition register as specified by the transition filters. Event 
registers are destructive read-only. Reading data from an event register clears the content of that 
register.
Table 4-10Data Questionable Frequency Condition Register Bits
Bit
Description
0
Synth. Unlocked. A 1 in this bit position indicates that the synthesizer is unlocked.
1
10 MHz Ref Unlocked. A 1 in this bit position indicates that the 10 MHz reference signal is unlocked.
2
a
a.In the N5161A/81A and N5162A/82A these bits are always set to 0.
1 GHz Ref Unlocked. A 1 in this bit position indicates that the 1 GHz reference signal is unlocked.
3
b
b.In the N5161A/62A/81A/82A/83A, E4428C, E8257D, E8663B, and the E8663D, this bit is always set to 0.
Baseband 1 Unlocked. A 1 in this bit position indicates that the baseband generator is unlocked.
4
Unused. This bit is always set to 0.
5
b
Sampler Loop Unlocked. A 1 in this bit position indicates that the sampler loop is unlocked.
6
b
YO Loop Unlocked. A 1 in this bit position indicates that the YO loop is unlocked.
714
Unused. These bits are always set to 0.
15
Always 0.
Query:
STATus:QUEStionable:FREQuency:CONDition?
Response:
The decimal sum of the bits set to 1.
Commands:
STATus:QUEStionable:FREQuency:NTRansition <value> (negative transition) or 
STATus:QUEStionable:FREQuency:PTRansition <value> (positive transition) where <value> is the 
sum of the decimal values of the bits you want to enable.
Queries:
STATus:QUEStionable:FREQuency:NTRansition?
STATus:QUEStionable:FREQuency:PTRansition?
Query:
STATus:QUEStionable:FREQuency[:EVENt]?
200
Agilent Signal Generators Programming Guide
Programming the Status Register System
Status Groups
Data Questionable Frequency Event Enable Register
Lets you choose which bits in the Data Questionable Frequency Event Register set the summary bit 
(bit 5 of the Data Questionable Condition Register) to 1.
Command:
STATus:QUEStionable:FREQuency:ENABle <value>, where <value> is the sum of the decimal values 
of the bits you want to enable. 
Example:
Enable bit 4 and bit 3 so that whenever either of those bits are set to 1, the Data Questionable 
Frequency summary bit of the Data Questionable Condition Register is set to 1. Send the command 
STAT:QUES:FREQ:ENAB 520 (16 + 8). 
Query:
STATus:QUEStionable:FREQuency:ENABle?
Response:
Decimal value of the sum of the bits previously enabled with the 
STATus:QUEStionable:FREQuency:ENABle <value> command.
Agilent Signal Generators Programming Guide
201
Programming the Status Register System
Status Groups
Data Questionable Modulation Status Group
NOTE
This status group does not apply to the N5161A/81A and the N5162A/82A, and returns zero 
when queried. See Table 4-11 on page 202 for more information.
The Data Questionable Modulation Status Group is used to determine the specific event that set bit 7 
in the Data Questionable Condition Register. This group consists of the Data Questionable Modulation 
Condition Register, the Data Questionable Modulation Transition Filters (negative and positive), the 
Data Questionable Modulation Event Register, and the Data Questionable Modulation Event Enable 
Register
This is the named 
status register for 
the E4438C. 
However, not all 
signal generator 
models use all of 
the shown events 
(i.e. some use only 
a subset of the 
E4438C’s status 
registers).
202
Agilent Signal Generators Programming Guide
Programming the Status Register System
Status Groups
Data Questionable Modulation Condition Register
The Data Questionable Modulation Condition Register continuously monitors the hardware and 
firmware status of the signal generator. Condition registers are read-only.
Data Questionable Modulation Transition Filters (negative and positive)
The Data Questionable Modulation Transition Filters specify which type of bit state changes in the 
condition register set corresponding bits in the event register. Changes can be positive (0 to 1) or 
negative (1 to 0).
Data Questionable Modulation Event Register
The Data Questionable Modulation Event Register latches transition events from the condition register 
as specified by the transition filters. Event registers are destructive read-only. Reading data from an 
event register clears the content of that register.
Table 4-11     Data Questionable Modulation Condition Register Bits
Bit
Description
0
Modulation 1 Undermod. A 1 in this bit position indicates that the External 1 input, ac coupling on, is less than 
0.97 volts.
1
Modulation 1 Overmod. A 1 in this bit position indicates that the External 1 input, ac coupling on, is more than 
1.03 volts.
2
Modulation 2 Undermod. A 1 in this bit position indicates that the External 2 input, ac coupling on, is less than 
0.97 volts.
3
Modulation 2 Overmod. A 1 in this bit position indicates that the External 2 input, ac coupling on, is more than 
1.03 volts.
4
Modulation Uncalibrated. A 1 in this bit position indicates that modulation is uncalibrated.
514
Unused. This bit is always set to 0.
15
Always 0.
Query:
STATus:QUEStionable:MODulation:CONDition?
Response:
The decimal sum of the bits set to 1
Commands:
STATus:QUEStionable:MODulation:NTRansition <value> (negative transition), or 
STATus:QUEStionable:MODulation:PTRansition <value> (positive transition), where <value> is 
the sum of the decimal values of the bits you want to enable.
Queries:
STATus:QUEStionable:MODulation:NTRansition? 
STATus:QUEStionable:MODulation:PTRansition?
Query:
STATus:QUEStionable:MODulation[:EVENt]?