mvc export to pdf : Convert pdf pages to jpg online Library application component .net html winforms mvc E8251-9035524-part503

Agilent Signal Generators Programming Guide
233
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
Waveform Data Encryption
You can download encrypted waveform data extracted from one signal generator into another signal 
generator with the same option or software license for the modulation format. You can also extract 
encrypted waveform data created with software such as MATLAB or ADS, providing the data was 
downloaded to the signal generator using the proper command.
When you generate a waveform from the signal generator’s internal ARB modulation format 
(ESG/PSG only), the resulting waveform data is automatically stored in volatile memory and is 
available for extraction as an encrypted file.
When you download an exported waveform using a Agilent Signal Studio software product, you can 
use the FTP process and the securewave directory or SCPI commands, to extract the encrypted file 
to the non–volatile memory on the signal generator. Refer to “File Transfer Methods” on page 234.
Encrypted I/Q Files and the Securewave Directory
The signal generator uses the securewave directory to perform file encryption (extraction) and 
decryption (downloads). The securewave directory is not an actual storage directory, but rather a 
portal for the encryption and decryption process. While the securewave directory contains file 
names, these are actually pointers to the true files located in signal generator memory (volatile or 
non–volatile). When you download an encrypted file, the securewave directory decrypts the file and 
unpackages the contents into its file header, I/Q data, and marker data. When you extract a file, the 
securewave directory packages the file header, I/Q data, and marker data and encrypts the waveform 
data file. When you extract the waveform file (I/Q data file), it includes the other two files, so there 
is no need to extract each one individually.
The signal generator uses the following securewave directory paths for file extractions and encrypted 
file downloads:
Volatile   
/user/bbg1/securewave/file_name or swfm:file_name
Non–volatile  
/user/securewave or snvwfm1:file_name
NOTE
To extract files (other than user–created I/Q files) and to download encrypted files, you 
must use the securewave directory. If you attempt to extract previously downloaded 
encrypted files (including Signal Studio downloaded files or internally created signal 
generator files (ESG/PSG only)) without using the securewave directory, the signal generator 
generates an error and displays:
ERROR: 221, Access Denied.
Encrypted I/Q Files and the Securewave Directory (X-Series and MXG)
NOTE
Header parameters of files stored on the Agilent X-Series or MXG’s internal or USB media 
cannot be changed unless the file is copied to the volatile BBG memory. For more 
information on modifying header parameters, refer to the User’s Guide.
When downloading encrypted files (.SECUREWAVE) from the USB media that have had the file suffix 
Convert pdf pages to jpg online - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf to gif or jpg; convert pdf to jpg 100 dpi
Convert pdf pages to jpg online - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert multi page pdf to jpg; to jpeg
234
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
changed to something other than .SECUREWAVE, you must use the Use As or Copy File to Instrument 
menus to play an encrypted waveform file in the signal generator.
File Transfer Methods
• SCPI using VXI–11 (VMEbus Extensions for Instrumentation as defined in VXI–11)
• SCPI over the GPIB or RS 232
• SCPI with sockets LAN (using port 5025)
• File Transfer Protocol (FTP)
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# sample code for PDF to jpg image conversion. This demo code convert PDF file all pages to jpg images. // Define input and output files path.
change file from pdf to jpg on; convert pdf picture to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.Office.Inner.Office03.dll. RasterEdge.XDoc.PDF.dll. This demo code convert TIFF file all pages to jpg images.
change pdf to jpg image; reader pdf to jpeg
Agilent Signal Generators Programming Guide
235
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
SCPI Command Line Structure
The signal generator expects to see waveform data as block data (binary files). The IEEE standard 
488.2–1992 section 7.7.6 defines block data. The following example shows how to structure a SCPI 
command for downloading waveform data (#ABC represents the block data):
:MMEM:DATA "<file_name>",#ABC
"<file_name> the I/Q file name and file path within the signal generator
 
indicates the start of the data block
A  
the number of decimal digits present in B
B  
a decimal number specifying the number of data bytes to follow in C
C  
the actual binary waveform data
The following example demonstrates this structure:
WFM1:  
the file path
my_file  
the I/Q file name as it will appear in the signal generator’s memory catalog
 
indicates the start of the data block
3  
B has three decimal digits
240  
240 bytes of data to follow in C
12%S!4&07#8g*Y9@7...  the ASCII representation of some of the binary data downloaded to the 
signal generator, however not all ASCII values are printable
Commands and File Paths for Downloading and Extracting Waveform Data
NOTE
Filenames should not exceed 23 characters.
You can download or extract waveform data using the commands and file paths in the following 
tables:
• Table 5-7, “Downloading Unencrypted Files for No Extraction (Extraction allowed on the X-Series 
and MXG Only),” on page 236
• Table 5-8, “Downloading Encrypted Files for No Extraction (Extraction allowed on the X-Series 
and MXG Only),” on page 236
• Table 5-9, “Downloading Unencrypted Files for Extraction,” on page 236
• Table 5-11, “Downloading Encrypted Files for Extraction,” on page 238
• Table 5-12, “Extracting Encrypted Waveform Data,” on page 238
file_name
A
C
MMEM:DATA “WFM1:my_file”,#3 240 12%S!4&07#8g*Y9@7...
B
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
convert pdf to jpg converter; convert pdf page to jpg
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Resize converted image files in VB.NET. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Embed PDF to image converter in viewer.
convert pdf file to jpg format; changing file from pdf to jpg
236
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
Table 5-7 7 Downloading Unencrypted Files for No Extraction (Extraction allowed on the X-Series and MXG
a
Only)
a.Refer to note on page 232.
Download Method/ 
Memory Type
Command Syntax Options
SCPI/volatile memory
MMEM:DATA "WFM1:<file_name>",<blockdata>
MMEM:DATA "MKR1:<file_name>",<blockdata>
MMEM:DATA "HDR1:<file_name>",<blockdata>
SCPI/volatile memory with 
full directory path
MMEM:DATA "user/bbg1/waveform/<file_name>",<blockdata>
MMEM:DATA "user/bbg1/markers/<file_name>",<blockdata>
MMEM:DATA "user/bbg1/header/<file_name>",<blockdata>
SCPI/non–volatile memory
MMEM:DATA "NVWFM:<file_name>",<blockdata>
MMEM:DATA "NVMKR:<file_name>",<blockdata>
MMEM:DATA "NVHDR:<file_name>",<blockdata>
SCPI/non–volatile memory 
with full directory path
MMEM:DATA /user/waveform/<file_name>",<blockdata>
MMEM:DATA /user/markers/<file_name>",<blockdata>
MMEM:DATA /user/header/<file_name>",<blockdata>
Table 5-8 8 Downloading Encrypted Files for No Extraction (Extraction allowed on the X-Series and MXG
a
Only)
a.Refer to note on page 232.
Download Method 
/Memory Type
Command Syntax Options
SCPI/volatile memory
MMEM:DATA "user/bbg1/securewave/<file_name>",<blockdata>
MMEM:DATA "SWFM1:<file_name>",<blockdata>
MMEM:DATA "file_name@SWFM1",<blockdata>
SCPI/non–volatile memory
MMEM:DATA "user/securewave/<file_name>",<blockdata>
MMEM:DATA "SNVWFM:<file_name>",<blockdata>
MMEM:DATA "file_name@SNVWFM",<blockdata>
Table 5-9 9 Downloading Unencrypted Files for Extraction
Download Method/ 
Memory Type
Command Syntax Options
SCPI/volatile memory
a
MEM:DATA:UNPRotected "/user/bbg1/waveform/file_name",<blockdata>
MEM:DATA:UNPRotected "/user/bbg1/markers/file_name",<blockdata>
MEM:DATA:UNPRotected "/user/bbg1/header/file_name",<blockdata>
MEM:DATA:UNPRotected "WFM1:file_name",<blockdata>
MEM:DATA:UNPRotected "MKR1:file_name",<blockdata>
MEM:DATA:UNPRotected "HDR1:file_name",<blockdata>
MEM:DATA:UNPRotected "file_name@WFM1",<blockdata>
MEM:DATA:UNPRotected "file_name@MKR1",<blockdata>
MEM:DATA:UNPRotected "file_name@HDR1",<blockdata>
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
Create multiple pages Tiff file from PDF document. Convert PDF to image file formats with high quality, support converting PDF to PNG, JPG, BMP and GIF.
.pdf to .jpg online; convert pdf file into jpg format
VB.NET Create PDF from images Library to convert Jpeg, png images
Components to batch convert PDF documents in Visual Basic .NET class. Support create PDF from multiple image formats in VB.NET, including Jpg, Png, Bmp, Gif
pdf to jpeg converter; convert pdf into jpg online
Agilent Signal Generators Programming Guide
237
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
SCPI/non–volatile 
memory
a
MEM:DATA:UNPRotected "/user/waveform/file_name",<blockdata>
MEM:DATA:UNPRotected "/user/markers/file_name",<blockdata>
MEM:DATA:UNPRotected "/user/header/file_name",<blockdata>
MEM:DATA:UNPRotected "NVWFM:file_name",<blockdata>
MEM:DATA:UNPRotected "NVMKR:file_name",<blockdata>
MEM:DATA:UNPRotected "NVHDR:file_name",<blockdata>
MEM:DATA:UNPRotected "file_name@NVWFM",<blockdata>
MEM:DATA:UNPRotected "file_name@NVMKR",<blockdata>
MEM:DATA:UNPRotected "file_name@NVHDR",<blockdata>
FTP/volatile memory
b
put <file_name> /user/bbg1/waveform/<file_name>
put <file_name> /user/bbg1/markers/<file_name>
put <file_name> /user/bbg1/header/<file_name>
FTP/non–volatile 
memory
b
put <file_name> /user/waveform/<file_name>
put <file_name> /user/markers/<file_name>
put <file_name> /user/header/<file_name>
a.On the N5172B/82B and N5162A/82A the :MEM:DATA:UNPRotected command is not required to be able to extract files (i.e. use 
:MEM:DATA). For more information, refer to the SCPI Command Reference.
b. See “FTP Procedures” on page 239.
Table 5-10Extracting Unencrypted I/Q Data
Download 
Method/Memory 
Type
Command Syntax Options
SCPI/volatile 
memory
MMEM:DATA? "/user/bbg1/waveform/<file_name>"
MMEM:DATA? "WFM1:<file_name>"
MMEM:DATA? "<file_name>@WFM1"
SCPI/non–volatile 
memory 
MMEM:DATA? "/user/waveform/<file_name>"
MMEM:DATA? "NVWFM:<file_name>"
MMEM:DATA? "<file_name>@NVWFM"
FTP/volatile 
memory
a
get /user/bbg1/waveform/<file_name>
get /user/bbg1/markers/<file_name>
get /user/bbg1/header/<file_name>
FTP/non–volatile 
memory
a
get /user/waveform/<file_name>
get /user/markers/<file_name>
get /user/header/<file_name>
a. See “FTP Procedures” on page 239.
Table 5-9 9 Downloading Unencrypted Files for Extraction
Download Method/ 
Memory Type
Command Syntax Options
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
Supports for changing image size. Also supports convert PDF files to jpg, jpeg images. C# class source codes and online demos are provided for .NET.
convert pdf file to jpg; changing pdf file to jpg
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
Use C# Code to Convert Jpeg to Tiff. string[] imagePaths = { @"C:\demo1.jpg", @"C:\demo2.jpg", @"C:\demo3.jpg" }; // Construct List<REImage> object.
convert pdf images to jpg; convert pdf to 300 dpi jpg
238
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
Table 5-11Downloading Encrypted Files for Extraction
Download 
Method/Memory 
Type
Command Syntax Options
SCPI/volatile
a
memory
MEM:DATA:UNPRotected "/user/bbg1/securewave/file_name",<blockdata>
MEM:DATA:UNPRotected "SWFM1:file_name",<blockdata>
MEM:DATA:UNPRotected "file_name@SWFM1",<blockdata>
SCPI/non–volatile 
memory
a
MEM:DATA:UNPRotected "/user/securewave/file_name",<blockdata>
MEM:DATA:UNPRotected "SNVWFM:file_name",<blockdata>
MEM:DATA:UNPRotected "file_name@SNVWFM",<blockdata>
FTP/volatile 
memory
b
put <file_name> /user/bbg1/securewave/<file_name>
FTP/non–volatile 
memory
b
put <file_name> /user/securewave/<file_name>
a.On the X-Series and MXG the :MEM:DATA:UNPRotected command is not required to be able to extract files (i.e. use :MEM:DATA). 
For more information, refer to the SCPI Command Reference.
b. See “FTP Procedures” on page 239.
Table 5-12Extracting Encrypted Waveform Data
Download 
Method/Memory 
Type
Command Syntax Options
SCPI/volatile 
memory
MMEM:DATA? "/user/bbg1/securewave/file_name"
MMEM:DATA? "SWFM1:file_name"
MMEM:DATA? "file_name@SWFM1"
SCPI/non–volatile 
memory 
MMEM:DATA? "/user/securewave/file_name"
MMEM:DATA? "SNVWFM:file_name"
MMEM:DATA? "file_name@SNVWFM"
FTP/volatile 
memory
a
get /user/bbg1/securewave/<file_name>
FTP/non–volatile 
memory
a
get /user/securewave/<file_name>
a. See “FTP Procedures” on page 239.
Agilent Signal Generators Programming Guide
239
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
FTP Procedures
CAUTION
Avoid using the *OPC? or *WAI commands to verify that the FTP process has been 
completed. These commands can potentially hang up due to the processing of other 
SCPI parser operations. Refer to the SCPI Command Reference.
NOTE
If you are remotely FTPing files and need to verify the completion of the FTP process, then 
query the instrument by using SCPI commands such as: ':MEM:DATA:', ':MEM:CAT', '*STB?', 
'FREQ?', '*IDN?', 'OUTP:STAT?'. Refer to the SCPI Command Reference.
There are three ways to FTP files:
• use Microsoft’s® Internet Explorer FTP feature
• use the PC’s or UNIX command window
• use the signal generator’s internal web server following the firmware requirements in the table 
below
Using Microsoft’s Internet Explorer
1. Enter the signal generator’s hostname or IP address as part of the FTP URL.
ftp://<host name> or 
ftp://<IP address>
2. Press Enter on the keyboard or Go from the Internet Explorer window.
The signal generator files appear in the Internet Explorer window.
3. Drag and drop files between the PC and the Internet Explorer window
Using the Command Window (PC or UNIX)
This procedure downloads to non–volatile memory. To download to volatile memory, change the file 
path.
Signal Generator
Firmware Version (Required 
for Web Server Compatibility)
N516xA
a
, N518xA
a.The N5161A and N5162A require firmware versions A.0140 or newer.
All
E44x8C
 C.03.10
E82x7D, E8663B/63D
All
240
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
CAUTION
Get and Put commands write over existing files by the same name in destination 
directories. Remember to change remote and local filenames to avoid the loss of data.
NOTE
If a filename has a space, quotations are required around the filename.
Always transfer the waveform file before transferring the marker file.
For additional information on FTP commands, refer to the operating system’s Window Help 
and Support Center.
1. From the PC command prompt or UNIX command line, change to the destination directory for the 
file you intend to download.
2. From the PC command prompt or UNIX command line, type ftp <instrument name>. Where 
instrument name is the signal generator’s hostname or IP address.
3. At the User: prompt in the ftp window, press Enter (no entry is required).
4. At the Password: prompt in the ftp window, press Enter (no entry is required).
5. At the ftp prompt, either put a file or get a file:
To put a file, type:
put <file_name> /user/waveform/<file_name1>
where <file_name> is the name of the file to download and <file_name1> is the name 
designator for the signal generator’s /user/waveform/ directory.
If <filename1> is unspecified, ftp uses the specified <file_name> to name <file_name1>.
• If a marker file is associated with the data file, use the following command to download it to 
the signal generator:
put <marker file_name> /user/markers/<file_name1>
where <marker file_name> is the name of the file to download and <file_name1> is the name 
designator for the file in the signal generator’s /user/markers/ directory. Marker files and 
the associated I/Q waveform data have the same name.
For more examples of put command usage refer to Table 5-13.
Table 5-13   Put Command Examples
Command 
Results
Local
Remote
Notes
Incorrect
put <filename.wfm>
put <filename.mkr>
/user/waveform/<filename1.wfm>
/user/marker/<filename1.mkr>
Produces two 
separate and 
incompatible files.
Agilent Signal Generators Programming Guide
241
Creating and Downloading Waveform Files
Commands for Downloading and Extracting Waveform Data
To get a file, type:
get /user/waveform/<file_name1> <file_name>
where <file_name1> is the file to download from the signal generator’s /user/waveform/ 
directory and <file_name> is the name designator for the local PC/UNIX.
• If a marker file is associated with the data file, use the following command to download it to 
the local PC/UNIX directory:
get /user/markers/<file_name1> <marker file_name>
where <marker file_name1> is the name of the marker file to download from the signal 
generator’s /user/markers/ directory and <marker file_name> is the name of the file to be 
downloaded to the local PC/UNIX.
For more examples of get command usage refer to Table 5-14.
6. At the ftp prompt, type: bye
7. At the command prompt, type: exit
Using the Signal Generator’s Internal Web Server
1. Enter the signal generator’s hostname or IP address in the URL.
http://<host name> or <IP address>
2. Click the Signal Generator FTP Access button located on the left side of the window.
The signal generator files appear in the web browser’s window.
3. Drag and drop files between the PC and the browser’s window
For more information on the web server feature, see Chapter 1.
Correct
put <filename.wfm> 
put <filename.mkr>
/user/waveform/<filename1>
/user/marker/<filename1>
Creates a waveform 
file and a compatible 
marker file.
Table 5-14     Get Command Examples
Command 
Results
Local
Remote
Notes
Incorrect
get /user/waveform/file
get /user/marker/file
file1 
file1
Results in file1 containing only the 
marker data.
Correct
get /user/waveform/file
get /user/marker/file
file1.wfm
file1.mkr
Creates a waveform file and a 
compatible marker file. It is easier to 
keep files associated by varying the 
extenders.
Table 5-13   Put Command Examples
Command 
Results
Local
Remote
Notes
242
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Creating Waveform Data
Creating Waveform Data
This section examines the C++ code algorithm for creating I/Q waveform data by breaking the 
programming example into functional parts and explaining the code in generic terms. This is done to 
help you understand the code algorithm in creating the I and Q data, so you can leverage the concept 
into your programming environment. The SCPI Command Reference, contains information on how to 
use SCPI commands to define the markers (polarity, routing, and other marker settings). If you do 
not need this level of detail, you can find the complete programming examples in “Programming 
Examples” on page 261.
You can use various programming environments to create ARB waveform data. Generally there are 
two types:
• Simulation software this includes MATLAB, Agilent Technologies EESof Advanced Design 
System (ADS), Signal Processing WorkSystem (SPW), and so forth.
• Advanced programming languages—this includes, C++, VB, VEE, MS Visual Studio.Net, Labview, 
and so forth.
No matter which programming environment you use to create the waveform data, make sure that the 
data conforms to the data requirements shown on page 213. To learn about I/Q data for the signal 
generator, see “Understanding Waveform Data” on page 213.
Code Algorithm
This section uses code from the C++ programming example “Importing, Byte Swapping, Interleaving, 
and Downloading I and Q Data—Big and Little Endian Order” on page 277 to demonstrate how to 
create and scale waveform data.
There are three steps in the process of creating an I/Q waveform:
1. Create the I and Q data.
2. Save the I and Q data to a text file for review.
3. Interleave the I and Q data to make an I/Q file, and swap the byte order for little–endian 
platforms.
For information on downloading I/Q waveform data to a signal generator, refer to “Commands and 
File Paths for Downloading and Extracting Waveform Data” on page 235 and “Downloading Waveform 
Data” on page 248.
1. Create I and Q data.
The following lines of code create scaled I and Q data for a sine wave. The I data consists of one 
period of a sine wave and the Q data consists of one period of a cosine wave.