Getting Started with Remote Operation
Troubleshooting
Troubleshooting
In each section of this document, there is information that is related to troubleshooting that topic, if 
applicable. Refer to those corresponding sections in this document as well as to the User’s Guide, 
before using the diagnostics mode referred to in the Service Guide and in the caution below.
CAUTION
All X-Series and MXGs have a fail-safe and diagnostic mode that should only be used if 
all other troubleshooting mentioned in this document has been attempted and failed. If 
the diagnostic mode is determined to be needed, refer to the Service Guide.
The fail-safe and diagnostic mode can be enabled on the N5161A/62A signal generators 
by pressing a combination of the front panel hardkeys: LAN Reset and the power switch 
during boot-up. This fail-safe and diagnostic mode should rarely be used as the 
instrument’s data could be permanently damaged. 
• If the diagnostic mode fails to function, refer to the Service Guide.
NOTE
If the LAN Reset hardkey has been pressed and then the power is cycled on the instrument, 
the web-server will be enabled after reboot.
Convert pdf document to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
batch pdf to jpg converter online; convert pdf into jpg online
Convert pdf document to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
best program to convert pdf to jpg; change from pdf to jpg
24
Agilent Signal Generators Programming Guide
Getting Started with Remote Operation
Error Messages
Error Messages
If an error condition occurs in the signal generator, it is reported to both the SCPI (remote interface) 
error queue and the front panel display error queue. These two queues are viewed and managed 
separately; for information on the front panel display error queue, refer to the User’s Guide.
NOTE
For additional general information on troubleshooting problems with your connections, refer 
to the Help in the Agilent IO Libraries and documentation.
When accessing error messages using the SCPI (remote interface) error queue, the error numbers and 
the <error_description> portions of the error query response are displayed on the host terminal.
Error Message File
A complete list of error messages is provided in the file errormessages.pdf, on the CD-ROM supplied 
with your instrument. In the error message list, an explanation is generally included with each error 
to further clarify its meaning. The error messages are listed numerically. In cases where there are 
multiple listings for the same error number, the messages are in alphabetical order. 
Characteristic
SCPI Remote Interface Error Queue
Capacity (#errors)
30
Overflow Handling
Linear, first-in/first-out.
Replaces newest error with: -350, Queue overflow
Viewing Entries
a
a.On the Agilent X-Series and MXG, using this SCPI command to read out the error messages clears the display of the ERR annunciator 
and the error message at the bottom of the screen.
Use SCPI query SYSTem:ERRor[:NEXT]?
Clearing the Queue
b
b.On the Agilent X-Series and MXG, executing the SCPI command *CLS clears the display of the ERR annunciator and the error message 
at the bottom of the screen.
Power up
Send a *CLS command
Read last item in the queue
Unresolved Errors
c
c.Errors that still exist after clearing the error queue. For example, unlock.
Re-reported after queue is cleared.
No Errors
When the queue is empty (every error in the queue has been read, or the queue is cleared), the 
following message appears in the queue:
+0, "No error"
Online Convert PDF to Jpeg images. Best free online PDF JPEG
to make it as easy as possible to convert your PDF Your PDF and JPG files will be deleted from our XDoc.PDF for .NET) supports converting PDF document to JPEG
change pdf to jpg file; convert online pdf to jpg
Online Convert Jpeg to PDF file. Best free online export Jpg image
So, feel free to convert them too with our Download and try RasterEdge.XDoc.PDF for .NET with RasterEdge.com is professional provider of document, content and
convert pdf to jpeg on; change pdf file to jpg file
Agilent Signal Generators Programming Guide
25
Getting Started with Remote Operation
Error Messages
Error Message Types
Events generate only one type of error. For example, an event that generates a query error will not 
generate a device-specific, execution, or command error.
Query Errors (–499 to –400) indicate that the instrument’s output queue control has detected a 
problem with the message exchange protocol described in IEEE 488.2, Chapter 6. Errors in this class 
set the query error bit (bit 2) in the event status register (IEEE 488.2, section 11.5.1). These errors 
correspond to message exchange protocol errors described in IEEE 488.2, 6.5. In this case:
• Either an attempt is being made to read data from the output queue when no output is either 
present or pending, or
• data in the output queue has been lost.
Device Specific Errors (–399 to –300, 201 to 703, and 800 to 810) indicate that a device operation 
did not properly complete, possibly due to an abnormal hardware or firmware condition. These codes 
are also used for self-test response errors. Errors in this class set the device-specific error bit (bit 3) 
in the event status register (IEEE 488.2, section 11.5.1).
The <error_message> string for a positive error is not defined by SCPI. A positive error indicates that 
the instrument detected an error within the GPIB system, within the instrument’s firmware or 
hardware, during the transfer of block data, or during calibration.
Execution Errors (–299 to –200) indicate that an error has been detected by the instrument’s 
execution control block. Errors in this class set the execution error bit (bit 4) in the event status 
register (IEEE 488.2, section 11.5.1). In this case:
• Either a <PROGRAM DATA> element following a header was evaluated by the device as outside of 
its legal input range or is otherwise inconsistent with the device’s capabilities, or
• a valid program message could not be properly executed due to some device condition.
Execution errors are reported after rounding and expression evaluation operations are completed. 
Rounding a numeric data element, for example, is not reported as an execution error.
Command Errors (–199 to –100) indicate that the instrument’s parser detected an IEEE 488.2 
syntax error. Errors in this class set the command error bit (bit 5) in the event status register (IEEE 
488.2, section 11.5.1). In this case:
• Either an IEEE 488.2 syntax error has been detected by the parser (a control-to-device message 
was received that is in violation of the IEEE 488.2 standard. Possible violations include a data 
element that violates device listening formats or whose type is unacceptable to the device.), or
• an unrecognized header was received. These include incorrect device-specific headers and 
incorrect or unimplemented IEEE 488.2 common commands.
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
Adobe PDF document can be easily loaded into your C#.NET project and converted to C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg
.pdf to jpg converter online; convert from pdf to jpg
C# Image Convert: How to Convert MS PowerPoint to Jpeg, Png, Bmp
RasterEdge.XDoc.PDF.dll. C:\input.pptx"; String outputDirectory = @"C:\output\"; // Convert PowerPoint to The second is for converting PPT document to Png image
best way to convert pdf to jpg; change file from pdf to jpg
26
Agilent Signal Generators Programming Guide
Getting Started with Remote Operation
Error Messages
C# Create PDF from images Library to convert Jpeg, png images to
C# Example: Convert More than Two Type Images to example shows how to build a PDF document with three new Bitmap(Program.RootPath + "\\" 1.jpg")); images.Add
change pdf file to jpg online; advanced pdf to jpg converter
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Sometimes, to convert PDF document into BMP, GIF, JPEG and PNG raster images in Visual Basic .NET
convert multi page pdf to single jpg; convert pdf to jpg c#
Agilent Signal Generators Programming Guide
27
2
Using IO Interfaces
NOTE
For the N5161A/62A the softkey menus and features mentioned in this chapter are only 
available through the Web–Enabled MXG or through SCPI commands. Refer to “Using the 
Web Browser” on page 11 and to the SCPI Command Reference.
Using the programming examples with GPIB, LAN, RS–232, and USB interfaces:
•  Using GPIB on page 27
•  Using LAN on page 33
•  Using RS–232 (ESG and PSG Only) on page 63
•  Using USB (Agilent X-Series and MXG) on page 71
Using GPIB 
GPIB enables instruments to be connected together and controlled by a computer. GPIB and its 
associated interface operations are defined in the ANSI/IEEE Standard 488.1–1987 and ANSI/IEEE 
Standard 488.2–1992. See the IEEE website, http://www.ieee.org, for details on these standards. 
The following sections contain information for installing a GPIB interface card or NI–GPIB interface 
card for your PC or UNIX–based system.
• “Installing the GPIB Interface” on page 27
• “Set Up the GPIB Interface” on page 29
• “Verify GPIB Functionality” on page 30
Installing the GPIB Interface
NOTE
You can also connect GPIB instruments to a PC USB port using the Agilent 82357A 
USB/GPIB Interface Converter, which eliminates the need for a GPIB card. For more 
information, refer to the table on page 28 or go to http://www.agilent.com/find/gpib.
A GPIB interface card can be installed in a computer. Two common GPIB interface cards are the 
Agilent GPIB interface card and the National Instruments (NI) PCI–GPIB card. Follow the interface 
card instructions for installing and configuring the card. The following table provide lists on some of 
the available interface cards. Also, see the Agilent website, http://www.agilent.com for details on 
GPIB interface cards. 
C# WPF PDF Viewer SDK to convert and export PDF document to other
document. 2. To TIFF. Export PDF to TIFF file format. 3. To TXT. Export and convert PDF to TXT file. 4. To Image. Convert PDF to image formats, such as PNG, JPG
convert pdf into jpg; convert pdf into jpg format
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
jpg", @"C:\demo2.jpg", @"C:\demo3.jpg" }; // Construct List new Exception("Fail to construct TIFF Document"); // Step3: Other Use C# Code to Convert Png to Tiff.
change pdf to jpg on; convert pdf to jpg batch
28
Agilent Signal Generators Programming Guide
Using IO Interfaces
Using GPIB
Interface
Type
Operating
System
IO Library
Languages
Backplane/
BUS
Max IO
(kB/sec)
Buffering
Agilent USB/GPIB Interface Converter for PC–Based Systems
Agilent 82357A 
Converter
Windows
a
98(SE)/ME/
2000®/XP
VISA / SICL
C/C++, Visual
Basic, Agilent 
VEE, HP Basic for 
Windows, NI 
Labview
USB 2.0 
(1.1 compatible)
850
Built–in
Agilent GPIB Interface Card for PC–Based Systems
Agilent 82341C 
for ISA bus 
computers
Windows
b
95/98/NT
/2000
®
VISA / SICL
C/C++, Visual
Basic, Agilent 
VEE, HP Basic for 
Windows
ISA/EISA,
16 bit
750
Built–in
Agilent 82341D 
Plug&Play for 
PC
Windows
95
VISA / SICL
C/C++, Visual
Basic, Agilent 
VEE, HP Basic for 
Windows
ISA/EISA,
16 bit
750
Built–in
Agilent 82350A 
for PCI bus 
computers
Windows 
95/98/NT
/2000
VISA / SICL
C/C++, Visual
Basic, Agilent 
VEE, HP Basic for 
Windows
PCI 32 bit
750
Built–in
Agilent 82350B 
for PCI bus 
computers
Windows 
98(SE)/ME/2000
/XP
VISA / SICL
C/C++, Visual
Basic, Agilent 
VEE, HP Basic for 
Windows
PCI 32 bit
> 900
Built–in
NI–GPIB Interface Card for PC–Based Systems
National 
Instruments 
PCI–GPIB
Windows
95/98/2000/ 
ME/NT
VISA
NI–488.2
c
C/C++, 
Visual BASIC, 
LabView
PCI 32 bit
1.5 MBps 
Built–in
National 
Instruments 
PCI–GPIB+
Windows
NT
VISA
NI–488.2
C/C++, 
Visual BASIC, 
LabView
PCI 32 bit
1.5 MBps
Built–in
Agilent–GPIB Interface Card for HP–UX Workstations
Agilent E2071C
HP–UX 9.x, 
HP–UX 10.01
VISA/SICL
ANSI C, 
Agilent VEE, 
Agilent BASIC, 
HP–UX
EISA
750
Built–in
Agilent E2071D
HP–UX 10.20
VISA/SICL
ANSI C, 
Agilent VEE, 
Agilent BASIC, 
HP–UX
EISA
750
Built–in
Agilent Signal Generators Programming Guide
29
Using IO Interfaces
Using GPIB
Set Up the GPIB Interface
For the Agilent X-Series and MXG refer to the Figure 2-1 and for the ESG and PSG, Figure 2-2 on 
page 30.
Figure 2-1 1 Setting the GPIB Address on the Agilent X-Series and MXG
Agilent E2078A
HP–UX 10.20
VISA/SICL
ANSI C, 
Agilent VEE, 
Agilent BASIC, 
HP–UX
PCI
750
Built–in
a.Windows 95, 98(SE), NT, 2000, and XP are registered trademarks of Microsoft Corporation.
b.Windows 98 and ME are registered trademarks of Microsoft Corporation.
c.NI–488.2 is a trademark of National Instruments Corporation.
Interface
Type
Operating
System
IO Library
Languages
Backplane/
BUS
Max IO
(kB/sec)
Buffering
Agilent USB/GPIB Interface Converter for PC–Based Systems
For details on each key, use the key help. Refer to “Getting Help (Agilent X-Series and MXG)” on page 21 and the User’s Guide. For 
additional SCPI command information, refer to the SCPI Command Reference.
Default address: 19 
Range: 0–30 
SCPI commands:
:SYSTem:COMMunicate:GPIB:ADDRess <number>
:SYSTem:COMMunicate:GPIB:ADDRess?
30
Agilent Signal Generators Programming Guide
Using IO Interfaces
Using GPIB
Figure 2-2 2 Setting the GPIB Address on the ESG/PSG
Connect a GPIB interface cable between the signal generator and the computer. (The following table 
lists cable part numbers.)
Verify GPIB Functionality
To verify GPIB functionality, use the VISA Assistant, available with the Agilent IO Library or the 
Getting Started Wizard available with the National Instrument IO Library. These utility programs 
enable you to communicate with the signal generator and verify its operation over GPIB. For 
information and instructions on running these programs, refer to the Help menu available in each 
utility. 
If You Have Problems
1. Verify that the signal generator’s address matches the address declared in the program (example 
programs in Chapter 3).
2. Remove all other instruments connected through GPIB and rerun the program.
3. Verify that the GPIB card’s name or id number matches the GPIB name or id number configured 
for your PC. 
Model
10833A
10833B
10833C
10833D
10833F
10833G
Length
1 meter
2 meters
4 meters
.5 meter
6 meters
8 meters
For details on each key, use the Key and Data Field Reference. For additional SCPI command information, refer to the SCPI Command Reference.
Default address: 19 
Range: 0–30 
SCPI commands:
:SYSTem:COMMunicate:GPIB:ADDRess <number>
:SYSTem:COMMunicate:GPIB:ADDRess?
Agilent Signal Generators Programming Guide
31
Using IO Interfaces
GPIB Programming Interface Examples
GPIB Interface Terms
An instrument that is part of a GPIB network is categorized as a listener, talker, or controller, 
depending on its current function in the network.
listener  
A listener is a device capable of receiving data or commands from other 
instruments. Several instruments in the GPIB network can be listeners 
simultaneously.
talker  
A talker is a device capable of transmitting data. To avoid confusion, a GPIB 
system allows only one device at a time to be an active talker.
controller  
A controller, typically a computer, can specify the talker and listeners (including 
itself) for an information transfer. Only one device at a time can be an active 
controller.
GPIB Programming Interface Examples
NOTE
The portions of the programming examples discussed in this section are taken from the full 
text of these programs that can be found in Chapter 3, “Programming Examples.”
• “Interface Check using HP Basic and GPIB” on page 31
• “Interface Check Using NI–488.2 and C++” on page 32
Before Using the GPIB Examples
If the Agilent GPIB interface card is used, the Agilent VISA library should be installed along with 
Agilent SICL. If the National Instruments PCI–GPIB interface card is used, the NI–VISA library along 
with the NI–488.2 library should be installed. Refer to “Selecting IO Libraries for GPIB” on page 10 
and the documentation for your GPIB interface card for details.
HP Basic addresses the signal generator at 719. The GPIB card is addressed at 7 and the signal 
generator at 19. The GPIB address designator for other libraries is typically GPIB0 or GPIB1.
The following sections contain HP Basic and C lines of programming removed from the 
programming interface examples in Chapter 3, “Programming Examples.” these portions of 
programming demonstrate the important features to consider when developing programming for use 
with the GPIB interface.
Interface Check using HP Basic and GPIB
This portion of the example program “Interface Check using HP Basic and GPIB” on page 31, causes 
the signal generator to perform an instrument reset. The SCPI command *RST places the signal 
generator into a pre–defined state and the remote annunciator (R) appears on the front panel 
display. 
The following program example is available on the signal generator Documentation CD–ROM as 
basicex1.txt. For the full text of this program, refer to “Interface Check using HP Basic and GPIB” on 
page 84 or to the signal generator’s documentation CD–ROM.
160   Sig_gen=719    ! Declares a variable to hold the signal generator's address
32
Agilent Signal Generators Programming Guide
Using IO Interfaces
GPIB Programming Interface Examples
170   LOCAL Sig_gen  ! Places the signal generator into Local mode
180   CLEAR Sig_gen  ! Clears any pending data I/O and resets the parser
190   REMOTE 719     ! Puts the signal generator into remote mode
200   CLEAR SCREEN   ! Clears the controllers display
210   REMOTE 719
220   OUTPUT Sig_gen;"*RST"  ! Places the signal generator into a defined state
Interface Check Using NI–488.2 and C++
This portion of the example program “Interface Check Using NI–488.2 and C++” on page 32, uses the 
NI–488.2 library to verify that the GPIB connections and interface are functional.
The following program example is available on the signal generator Documentation CD–ROM as 
niex1.cpp. For the full text of this program, refer to “Interface Check Using NI-488.2 and C++” on 
page 85 or to the signal generator’s documentation CD–ROM.
#include "stdafx.h"
#include <iostream>
#include "windows.h"
#include "Decl-32.h"
using namespace std;
int GPIB0=   0;         // Board handle
Addr4882_t Address[31]; // Declares an array of type Addr4882_t
int main(void)
{
int sig;                         // Declares a device descriptor variable
sig = ibdev(0, 19, 0, 13, 1, 0); // Aquires a device descriptor
ibclr(sig);                      // Sends device clear message to signal generator
ibwrt(sig, "*RST", 4);           // Places the signal generator into a defined state
Documents you may be interested
Documents you may be interested