mvc export to pdf : Change from pdf to jpg on software control cloud windows web page winforms class E8251-9035531-part511

Agilent Signal Generators Programming Guide
303
Creating and Downloading Waveform Files
Programming Examples
FileHandle = FreeFile()
On Error GoTo errorhandler
With SigGen                 'Set up the signal generator to accept a download
.IO.Timeout = 5000      'Timeout 50 seconds
.WriteString "*RST"     'Reset the signal generator.
End With
numPoints = (FileLen(strFilename))  'Get number of bytes in the file: 800 bytes
ReDim iq_data(0 To numPoints - 1)      'Dimension the iq_data array to the
'size of the IQ_DataVB file: 800 bytes
Open strFilename For Binary Access Read As #FileHandle  'Open the file for binary read
On Error GoTo file_error
For index = 0 To (numPoints - 1)    'Write the IQ_DataVB data to the iq_data array
Get #FileHandle, index + 1, data    '(index+1) is the record number
iq_data(index) = data
Next index
Close #FileHandle                   'Close the file
'Write the command to the Header string. NOTE: syntax
Header = "MEM:DATA ""/USER/WAVEFORM/IQ_DataVB"","
'Now write the data to the signal generator's non-volatile memory (NVWFM)
SigGen.WriteIEEEBlock Header, iq_data
SigGen.WriteString "*OPC?"          'Wait for the operation to complete
response = SigGen.ReadString        'Signal generator reponse to the OPC? query
Call MsgBox("Data downloaded to the signal generator", vbOKOnly, "Download")
Exit Sub
errorhandler:
MsgBox Err.Description, vbExclamation, "Error Occurred", Err.HelpFile, Err.HelpContext
Exit Sub
file_error:
Call MsgBox(Err.Description, vbOKOnly)  'Display any error message
Close #FileHandle
End Sub
Change from pdf to jpg on - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
batch pdf to jpg online; convert pdf into jpg online
Change from pdf to jpg on - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert pdf file to jpg online; changing pdf file to jpg
304
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Programming Examples
HP Basic Programming Examples
This section contains the following programming examples:
• “Creating and Downloading Waveform Data Using HP BASIC for Windows®” on page 304
• “Creating and Downloading Waveform Data Using HP BASIC for UNIX” on page 306
• “Creating and Downloading E443xB Waveform Data Using HP BASIC for Windows” on page 308
• “Creating and Downloading E443xB Waveform Data Using HP Basic for UNIX” on page 309
Creating and Downloading Waveform Data Using HP BASIC for Windows®
On the documentation CD, this programming example’s name is “hpbasicWin.txt.”
The following program will download a waveform using HP Basic for Windows into volatile ARB 
memory. The waveform generated by this program is the same as the default SINE_TEST_WFM 
waveform file available in the signal generator’s waveform memory. This code is similar to the code 
shown for BASIC for UNIX but there is a formatting difference in line 130 and line 140.
To download into non–volatile memory, replace line 190 with:
190 OUTPUT @PSG USING "#,K";":MMEM:DATA ""NVWFM:testfile"", #"
As discussed at the beginning of this section, I and Q waveform data is interleaved into one file in 
2’s compliment form and a marker file is associated with this I/Q waveform file. 
In the Output commands, USING “#,K” formats the data. The pound symbol (#) suppresses the 
automatic EOL (End of Line) output. This allows multiple output commands to be concatenated as if 
they were a single output. The “K” instructs HP Basic to output the following numbers or strings in 
the default format. 
10 !  RE-SAVE "BASIC_Win_file"
20    Num_points=200
30    ALLOCATE INTEGER Int_array(1:Num_points*2)
40    DEG
50    FOR I=1 TO Num_points*2 STEP 2
60      Int_array(I)=INT(32767*(SIN(I*360/Num_points)))
70    NEXT I
80    FOR I=2 TO Num_points*2 STEP 2
90      Int_array(I)=INT(32767*(COS(I*360/Num_points)))
100   NEXT I
110   PRINT "Data Generated"
120   Nbytes=4*Num_points
130   ASSIGN @PSG TO 719
140   ASSIGN @PSGb TO 719;FORMAT MSB FIRST
150   Nbytes$=VAL$(Nbytes)
160   Ndigits=LEN(Nbytes$)
Windows and MS Windows are U.S registered trademarks of Microsoft Corporation.
Online Convert Jpeg to PDF file. Best free online export Jpg image
Download Free Trial. Convert a JPG to PDF. Web Security. All your JPG and PDF files will be permanently erased from our servers after one hour.
convert pdf document to jpg; .pdf to jpg
JPG to PNG Converter | Convert JPEG to PNG, Convert PNG to JPG
Allow to change converting image with adjusted width & height; Change image resolution Open JPEG to PNG Converter first; Load JPG images from local folders in
convert pdf pictures to jpg; batch convert pdf to jpg online
Agilent Signal Generators Programming Guide
305
Creating and Downloading Waveform Files
Programming Examples
170   Ndigits$=VAL$(Ndigits)
180   WAIT 1
190   OUTPUT @PSG USING "#,K";":MMEM:DATA ""WFM1:data_file"",#"
200   OUTPUT @PSG USING "#,K";Ndigits$
210   OUTPUT @PSG USING "#,K";Nbytes$
220   WAIT 1
230   OUTPUT @PSGb;Int_array(*)
240   OUTPUT @PSG;END
250   ASSIGN @PSG TO *
260   ASSIGN @PSGb TO *
270   PRINT 
280   PRINT "*END*"
290   END
Program Comments  
10:
Program file name
20:
Sets the number of points in the waveform.
30:
Allocates integer data array for I and Q waveform points. 
40:
Sets HP BASIC to use degrees for cosine and sine functions.
50:
Sets up first loop for I waveform points.
60:
Calculate and interleave I waveform points.
70:
End of loop
80
Sets up second loop for Q waveform points.
90:
Calculate and interleave Q waveform points.
100:
End of loop.
120:
Calculates number of bytes in I/Q waveform.
130:
Opens an IO path to the signal generator using GPIB. 7 is the address of the GPIB card in the computer, 
and 19 is the address of the signal generator. This IO path is used to send ASCII data to the signal 
generator.
140:
Opens an IO path for sending binary data to the signal generator. 
150:
Creates an ASCII string representation of the number of bytes in the waveform.
160 to 170:
Finds the number of digits in Nbytes.
190:
Sends the first part of the SCPI command, MEM:DATA along with the name of the file, data_file, that 
will receive the waveform data. The name, data_file, will appear in the signal generator’s memory 
catalog. 
200 to 210:
Sends the rest of the ASCII header.
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Download Free Trial. Convert a PDF File to JPG. Web Security. Your PDF and JPG files will be deleted from our servers an hour after the conversion.
convert pdf file to jpg on; convert multi page pdf to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.PDF.dll. C:\input.tif"; String outputDirectory = @"C:\output\"; // Convert tiff to jpg and show How to change Tiff image to Bmp image in your C#
convert pdf file to jpg file; batch pdf to jpg
306
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Programming Examples
Creating and Downloading Waveform Data Using HP BASIC for UNIX
On the documentation CD, this programming example’s name is “hpbasicUx.txt.”
The following program shows you how to download waveforms using HP Basic for UNIX. The code is 
similar to that shown for HP BASIC for Windows, but there is a formatting difference in line 130 and 
line 140.
To download into non–volatile memory, replace line 190 with:
190 OUTPUT @PSG USING "#,K";":MMEM:DATA ""NVWFM:testfile"", #"
As discussed at the beginning of this section, I and Q waveform data is interleaved into one file in 
2’s compliment form and a marker file is associated with this I/Q waveform file.
In the Output commands, USING “#,K” formats the data. The pound symbol (#) suppresses the 
automatic EOL (End of Line) output. This allows multiple output commands to be concatenated as if 
they were a single output. The “K” instructs HP BASIC to output the following numbers or strings in 
the default format. 
10 !  RE-SAVE "UNIX_file"
20    Num_points=200
30    ALLOCATE INTEGER Int_array(1:Num_points*2)
40    DEG
50    FOR I=1 TO Num_points*2 STEP 2
60      Int_array(I)=INT(32767*(SIN(I*360/Num_points)))
70    NEXT I
80    FOR I=2 TO Num_points*2 STEP 2
90      Int_array(I)=INT(32767*(COS(I*360/Num_points)))
100   NEXT I
110   PRINT "Data generated "
120   Nbytes=4*Num_points
130   ASSIGN @PSG TO 719;FORMAT ON
140   ASSIGN @PSGb TO 719;FORMAT OFF
150   Nbytes$=VAL$(Nbytes)
160   Ndigits=LEN(Nbytes$)
170   Ndigits$=VAL$(Ndigits)
180   WAIT 1
190   OUTPUT @PSG USING "#,K";":MMEM:DATA ""WFM1:data_file"",#"
200   OUTPUT @PSG USING "#,K";Ndigits$
230:
Sends the binary data. Note that PSGb is the binary IO path.
240:
Sends an End–of–Line to terminate the transmission.
250 to 260:
Closes the connections to the signal generator.
290:
End the program.
Program Comments  (Continued)
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
String inputFilePath = @"C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg. C# sample code for PDF to jpg image conversion.
convert multiple pdf to jpg online; conversion of pdf to jpg
JPG to JBIG2 Converter | Convert JPEG to JBIG2, Convert JBIG2 to
Users may easily change image size, rotate image angle, set image rotation in dpi Covert JPG & JBIG2 image with high-quality; Provide user-friendly interface
convert pdf to jpg 300 dpi; changing pdf to jpg on
Agilent Signal Generators Programming Guide
307
Creating and Downloading Waveform Files
Programming Examples
210   OUTPUT @PSG USING "#,K";Nbytes$
220   WAIT 1
230   OUTPUT @PSGb;Int_array(*)
240   WAIT 2
241   OUTPUT @PSG;END
250   ASSIGN @PSG TO *
260   ASSIGN @PSGb TO *
270   PRINT 
280   PRINT "*END*"
290   END
Program Comments  
10:
Program file name
20:
Sets the number of points in the waveform.
30:
Allocates integer data array for I and Q waveform points. 
40:
Sets HP BASIC to use degrees for cosine and sine functions.
50:
Sets up first loop for I waveform points.
60:
Calculate and interleave I waveform points.
70:
End of loop
80
Sets up second loop for Q waveform points.
90:
Calculate and interleave Q waveform points.
100:
End of loop.
120:
Calculates number of bytes in I/Q waveform.
130:
Opens an IO path to the signal generator using GPIB. 7 is the address of the GPIB card in the computer, 
and 19 is the address of the signal generator. This IO path is used to send ASCII data to the signal 
generator.
140:
Opens an IO path for sending binary data to the signal generator. 
150:
Creates an ASCII string representation of the number of bytes in the waveform.
160 to 170:
Finds the number of digits in Nbytes.
190:
Sends the first part of the SCPI command, MEM:DATA along with the name of the file, data_file, that 
will receive the waveform data. The name, data_file, will appear in the signal generator’s memory 
catalog. 
200 to 210:
Sends the rest of the ASCII header.
230:
Sends the binary data. Note that PSGb is the binary IO path.
240:
Sends an End–of–Line to terminate the transmission.
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Or directly change PDF to Gif image file in VB.NET program with this demo code.
change format from pdf to jpg; bulk pdf to jpg converter online
JPEG to PDF Converter | Convert JPEG to PDF, Convert PDF to JPEG
similar software; Support a batch conversion of JPG to PDF with amazingly high speed; Get a compressed PDF file after conversion; Support
convert pdf into jpg format; .net convert pdf to jpg
308
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Programming Examples
Creating and Downloading E443xB Waveform Data Using HP BASIC for Windows
On the documentation CD, this programming example’s name is “e443xb_hpbasicWin2.txt.”
The following program shows you how to download waveforms using HP Basic for Windows into 
volatile ARB memory. This program is similar to the following program example as well as the 
previous examples. The difference between BASIC for UNIX and BASIC for Windows is the way the 
formatting, for the most significant bit (MSB) on lines 110 and 120, is handled.
To download into non–volatile ARB memory, replace line 160 with:
160 OUTPUT @ESG USING "#,K";":MMEM:DATA ""NVARBI:testfile"", #"
and replace line 210 with:
210 OUTPUT @ESG USING "#,K";":MMEM:DATA ""NVARBQ:testfile"", #"
First, the I waveform data is put into an array of integers called Iwfm_data and the Q waveform 
data is put into an array of integers called Qwfm_data. The variable Nbytes is set to equal the 
number of bytes in the I waveform data. This should be twice the number of integers in Iwfm_data, 
since an integer is 2 bytes. Input integers must be between 0 and 16383.
In the Output commands, USING “#,K” formats the data. The pound symbol (#) suppresses the 
automatic EOL (End of Line) output. This allows multiple output commands to be concatenated as if 
they were a single output. The “K” instructs HP Basic to output the following numbers or strings in 
the default format. 
10    ! RE-SAVE "ARB_IQ_Win_file"
20    Num_points=200
30    ALLOCATE INTEGER Iwfm_data(1:Num_points),Qwfm_data(1:Num_points)
40    DEG
50    FOR I=1 TO Num_points
60      Iwfm_data(I)=INT(8191*(SIN(I*360/Num_points))+8192)
70      Qwfm_data(I)=INT(8191*(COS(I*360/Num_points))+8192)
80    NEXT I
90    PRINT "Data Generated"
100   Nbytes=2*Num_points
110   ASSIGN @Esg TO 719
120   !ASSIGN @Esgb TO 719;FORMAT MSB FIRST
130   Nbytes$=VAL$(Nbytes)
140   Ndigits=LEN(Nbytes$)
150   Ndigits$=VAL$(Ndigits)
160   OUTPUT @Esg USING "#,K";":MMEM:DATA ""ARBI:file_name_1"",#"
170   OUTPUT @Esg USING "#,K";Ndigits$
180   OUTPUT @Esg USING "#,K";Nbytes$
250 to 260:
Closes the connections to the signal generator.
290:
End the program.
Program Comments  (Continued)
Agilent Signal Generators Programming Guide
309
Creating and Downloading Waveform Files
Programming Examples
190   OUTPUT @Esgb;Iwfm_data(*)
200   OUTPUT @Esg;END
210   OUTPUT @Esg USING "#,K";":MMEM:DATA ""ARBQ:file_name_1"",#"
220   OUTPUT @Esg USING "#,K";Ndigits$
230   OUTPUT @Esg USING "#,K";Nbytes$
240   OUTPUT @Esgb;Qwfm_data(*)
250   OUTPUT @Esg;END
260   ASSIGN @Esg TO *
270   ASSIGN @Esgb TO *
280   PRINT 
290   PRINT "*END*"
300   END
Creating and Downloading E443xB Waveform Data Using HP Basic for UNIX
On the documentation CD, this programming example’s name is “e443xb_hpbasicUx2.txt.”
The following program shows you how to download waveforms using HP BASIC for UNIX. It is similar 
to the previous program example. The difference is the way the formatting for the most significant bit 
(MSB) on lines is handled. 
First, the I waveform data is put into an array of integers called Iwfm_data and the Q waveform 
data is put into an array of integers called Qwfm_data. The variable Nbytes is set to equal the 
number of bytes in the I waveform data. This should be twice the number of integers in Iwfm_data, 
since an integer is represented 2 bytes. Input integers must be between 0 and 16383.
In the Output commands, USING “#,K” formats the data. The pound symbol (#) suppresses the 
automatic EOL (End of Line) output. This allows multiple output commands to be concatenated as if 
they were a single output. The “K” instructs HP BASIC to output the following numbers or strings in 
the default format. 
Program Comments  
10:
Program file name.
20
Sets the number of points in the waveform.
30:
Defines arrays for I and Q waveform points. Sets them to be integer arrays.
40:
Sets HP BASIC to use degrees for cosine and sine functions.
50:
Sets up loop to calculate waveform points.
60:
Calculates I waveform points.
70:
Calculates Q waveform points.
80:
End of loop.
160 and 210:
The I and Q waveform files have the same name
90 to 300:
See the table on page 305 for program comments.
310
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Programming Examples
10    ! RE-SAVE "ARB_IQ_file"
20    Num_points=200
30    ALLOCATE INTEGER Iwfm_data(1:Num_points),Qwfm_data(1:Num_points)
40    DEG
50    FOR I=1 TO Num_points
60      Iwfm_data(I)=INT(8191*(SIN(I*360/Num_points))+8192)
70      Qwfm_data(I)=INT(8191*(COS(I*360/Num_points))+8192)
80    NEXT I
90    PRINT "Data Generated"
100   Nbytes=2*Num_points
110   ASSIGN @Esg TO 719;FORMAT ON
120   ASSIGN @Esgb TO 719;FORMAT OFF
130   Nbytes$=VAL$(Nbytes)
140   Ndigits=LEN(Nbytes$)
150   Ndigits$=VAL$(Ndigits)
160   OUTPUT @Esg USING "#,K";":MMEM:DATA ""ARBI:file_name_1"",#"
170   OUTPUT @Esg USING "#,K";Ndigits$
180   OUTPUT @Esg USING "#,K";Nbytes$
190   OUTPUT @Esgb;Iwfm_data(*)
200   OUTPUT @Esg;END
210   OUTPUT @Esg USING "#,K";":MMEM:DATA ""ARBQ:file_name_1"",#"
220   OUTPUT @Esg USING "#,K";Ndigits$
230   OUTPUT @Esg USING "#,K";Nbytes$
240   OUTPUT @Esgb;Qwfm_data(*)
250   OUTPUT @Esg;END
260   ASSIGN @Esg TO *
270   ASSIGN @Esgb TO *
280   PRINT 
290   PRINT "*END*"
300   END
Program Comments  
10:
Program file name.
20
Sets the number of points in the waveform.
30:
Defines arrays for I and Q waveform points. Sets them to be integer arrays.
40:
Sets HP BASIC to use degrees for cosine and sine functions.
50:
Sets up loop to calculate waveform points.
60:
Calculates I waveform points.
70:
Calculates Q waveform points.
Agilent Signal Generators Programming Guide
311
Creating and Downloading Waveform Files
Troubleshooting Waveform Files
Troubleshooting Waveform Files 
80:
End of loop.
160 and 210:
The I and Q waveform files have the same name
90 to 300
See the table on page 307 for program comments.
Symptom
Possible Cause
ERROR 224, Text file busy
Attempting to download a waveform that has the same name as the waveform 
currently being played by the signal generator.
To solve the problem, either change the name of the waveform being downloaded 
or turn off the ARB.
ERROR 628, DAC over range
The amplitude of the signal exceeds the DAC input range. The typical causes are 
unforeseen overshoot (DAC values within range) or the input values exceed the 
DAC range. 
To solve the problem, scale or reduce the DAC input values. For more information, 
see “DAC Input Values” on page 216.
On the Agilent MXG, this error can occur if an encrypted file (.SECUREWAVE) is 
being downloaded to the signal generator from a PC or USB Media with a different 
suffix (i.e. not .SECUREWAVE).
To solve the problem, use the Use as or Copy File to Instrument softkey menus to 
download the encrypted file to the instrument. For more information, see 
“Encrypted I/Q Files and the Securewave Directory (X-Series and MXG)” on 
page 233.
ERROR 629, File format invalid
The signal generator requires a minimum of 60 samples to build a waveform and 
the same number of I and Q data points.
ERROR –321, Out of memory
There is not enough space in the ARB memory for the waveform file being 
downloaded.
To solve the problem, either reduce the file size of the waveform file or delete 
unnecessary files from ARB memory. Refer to “Waveform Memory” on page 226.
No RF Output
The marker RF blanking function may be active. To check for and turn RF blanking 
off, refer to “Configuring the Pulse/RF Blank (Agilent X-Series and MXG)” on 
page 312 and “Configuring the Pulse/RF Blank (ESG/PSG)” on page 312. This 
problem occurs when the file header contains unspecified settings and a previously 
played waveform used the marker RF blanking function.
For more information on the marker functions, see the User’s Guide.
Undesired output signal
Check for the following:
The data was downloaded in little endian order. See “Little Endian and Big 
Endian (Byte Order)” on page 214 for more information.
The waveform contains an odd number of samples. An odd number of samples 
can cause waveform discontinuity. See “Waveform Phase Continuity” on 
page 223 for more information.
Program Comments  (Continued)
312
Agilent Signal Generators Programming Guide
Creating and Downloading Waveform Files
Troubleshooting Waveform Files
Configuring the Pulse/RF Blank (Agilent X-Series and MXG)
Configuring the Pulse/RF Blank (ESG/PSG)
For details on each key, use the key help. Refer to “Getting Help (Agilent X-Series and MXG)” on page 21 and the User’s Guide. For 
additional SCPI command information, refer to the SCPI Command Reference.
If the default marker is used, 
toggle the Pulse/RF Blank (None) 
softkey to None. For more 
information on markers, refer to 
“Marker File” on page 221
SCPI commands:
[
:
S
O
U
R
c
e
]
:
R
A
D
i
o
[
1
]
:
A
R
B
:
M
D
E
S
t
i
n
a
t
i
o
n
:
P
U
L
S
e
N
O
N
E
|
M
1
|
M
2
|
M
3
|
M
4
[
:
S
O
U
R
c
e
]
:
R
A
D
i
o
[
1
]
:
A
R
B
:
M
D
E
S
t
i
n
a
t
i
o
n
:
P
U
L
S
e
?
Select Dual Arb More Marker Utilities 
on X-Series signal generators to 
access this menu.
For details on each key, use the Key and Data Field Reference. For additional SCPI command information, refer to the SCPI Command 
Reference.
If the default marker is 
used, toggle the 
Pulse/RF Blank (None) 
softkey to None. For 
more information on 
markers, refer to 
“Marker File” on 
page 221.
Mode Setup
Hardkey
SCPI commands:
[
:
S
O
U
R
c
e
]
:
R
A
D
i
o
:
A
R
B
:
M
D
E
S
t
i
n
a
t
i
o
n
:
P
U
L
S
e
N
O
N
E
|
M
1
|
M
2
|
M
3
|
M
4
[
:
S
O
U
R
c
e
]
:
R
A
D
i
o
:
A
R
B
:
M
D
E
S
t
i
n
a
t
i
o
n
:
P
U
L
S
e
?
Documents you may be interested
Documents you may be interested