mvc export to pdf : Convert pdf images to jpg Library SDK component .net asp.net wpf mvc E8251-903559-part525

Agilent Signal Generators Programming Guide
83
Programming Examples
GPIB Programming Interface Examples
Output Function
The HP Basic IO function OUTPUT and the other listed IO library functions put the signal generator 
into a listen mode and prepare it to receive ASCII data, typically SCPI commands. 
NI-488.2
The NI-488.2 library function sends the GPIB Selected 
Device Clear (SDC) message to the device described by ud.
ibclr(int ud)
SICL
The Agilent SICL function clears a device or interface. The 
function also discards data in both the read and write 
formatted IO buffers. The id parameter identifies the 
session.
iclear (id)
Library
Function Statement
Initialization Command
HP Basic
The function OUTPUT 719 puts the signal generator into 
remote mode, makes it a listener, and prepares it to receive 
data.
10 OUTPUT 719
VISA Library
The VISA library uses the above function and associated 
parameter list to output data. This function formats 
according to the format string and sends data to the device. 
The parameter list describes the session id and data to send.
viPrintf(parameter list)
NI-488.2
The NI-488.2 library function addresses the GPIB and writes 
data to the signal generator. The parameter list includes the 
instrument address, session id, and the data to send.
ibwrt(parameter list)
SICL
The Agilent SICL function converts data using the format 
string. The format string specifies how the argument is 
converted before it is output. The function sends the 
characters in the format string directly to the instrument. 
The parameter list includes the instrument address, data 
buffer to write, and so forth.
iprintf (parameter 
list)
Library
Function Statement
Initialization Command
Convert pdf images to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
batch convert pdf to jpg; convert pdf to jpg
Convert pdf images to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert pdf image to jpg; convert pdf to jpeg
84
Agilent Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
Enter Function 
The HP Basic function ENTER reads formatted data from the signal generator. Other IO libraries use 
similar functions to read data from the signal generator. 
Interface Check using HP Basic and GPIB
This simple program causes the signal generator to perform an instrument reset. The SCPI command 
*RST places the signal generator into a pre-defined state and the remote annunciator (R) appears on 
the front panel display. 
The following program example is available on the signal generator Documentation CD-ROM as 
basicex1.txt.
10    !******************************************************************************
20    !
30    !  PROGRAM NAME:         basicex1.txt
40    !
50    !  PROGRAM DESCRIPTION:  This program verifies that the GPIB connections and
60    !                        interface are functional.
70    !
80    !  Connect a controller to the signal generator using a GPIB cable.
90    !  
100   !
110   !  CLEAR and RESET the controller and type in the following commands and then
120   !  RUN the program:
130   !
Library
Function Statement
Initialization Command
HP Basic
The function ENTER 719 puts the signal generator into 
remote mode, makes it a talker, and assigns data or status 
information to a designated variable.
10 ENTER 719;
VISA Library
The VISA library uses the viScanf function and an 
associated parameter list to receive data. This function 
receives data from the instrument, formats it using the 
format string, and stores the data in the argument list. The 
parameter list includes the session id and string argument.
viScanf (parameter list)
NI-488.2
The NI-488.2 library function addresses the GPIB, reads 
data bytes from the signal generator, and stores the data 
into a specified buffer. The parameter list includes the 
instrument address and session id.
ibrd (parameter list)
SICL
The Agilent SICL function reads formatted data, converts it, 
and stores the results into the argument list. The conversion 
is done using conversion rules for the format string. The 
parameter list includes the instrument address, formatted 
data to read, and so forth.
iscanf (parameter list)
Online Convert PDF to Jpeg images. Best free online PDF JPEG
it as easy as possible to convert your PDF Download and try RasterEdge.XDoc.PDF for .NET processing, converting, compressing and stroing images, documents and
convert pdf photo to jpg; conversion of pdf to jpg
Online Convert Jpeg to PDF file. Best free online export Jpg image
So, feel free to convert them too with our tool. Easy converting! It enables you to build a PDF file with one or more images.
change file from pdf to jpg on; .net convert pdf to jpg
Agilent Signal Generators Programming Guide
85
Programming Examples
GPIB Programming Interface Examples
140   !******************************************************************************
150   !
160   Sig_gen=719    ! Declares a variable to hold the signal generator's address
170   LOCAL Sig_gen  ! Places the signal generator into Local mode
180   CLEAR Sig_gen  ! Clears any pending data I/O and resets the parser
190   REMOTE 719     ! Puts the signal generator into remote mode
200   CLEAR SCREEN   ! Clears the controllers display
210   REMOTE 719
220   OUTPUT Sig_gen;"*RST"  ! Places the signal generator into a defined state
230   PRINT "The signal generator should now be in REMOTE."
240   PRINT 
250   PRINT "Verify that the remote [R] annunciator is on.  Press the `Local' key, "
260   PRINT "on the front panel to return the signal generator to local control."
270   PRINT 
280   PRINT "Press RUN to start again."
290   END   ! Program ends
Interface Check Using NI-488.2 and C++
This example uses the NI-488.2 library to verify that the GPIB connections and interface are 
functional. Launch Microsoft Visual C++ 6.0, add the required files, and enter the following code into 
your .cpp source file.
The following program example is available on the signal generator Documentation CD-ROM as 
niex1.cpp.
// ***************************************************************************************
//
// PROGRAM NAME: niex1.cpp
//              
// PROGRAM DESCRIPTION: This program verifies that the GPIB connections and 
// interface are functional.
//
// Connect a GPIB cable from the PC GPIB card to the signal generator 
// Enter the following code into the source .cpp file and execute the program
//
// ***************************************************************************************
#include "stdafx.h"
#include <iostream>
#include "windows.h"
#include "Decl-32.h"
using namespace std;
int GPIB0=   0;         // Board handle
C# Create PDF from images Library to convert Jpeg, png images to
C# Create PDF from Raster Images, .NET Graphics and REImage File with XDoc Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp
best pdf to jpg converter for; pdf to jpg
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
VB.NET components for batch convert high resolution images from PDF. Convert PDF documents to multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap
change from pdf to jpg; batch convert pdf to jpg online
86
Agilent Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
Addr4882_t Address[31]; // Declares an array of type Addr4882_t
int main(void)
{
int sig;                         // Declares a device descriptor variable
sig = ibdev(0, 19, 0, 13, 1, 0); // Aquires a device descriptor
ibclr(sig);                      // Sends device clear message to signal generator
ibwrt(sig, "*RST", 4);           // Places the signal generator into a defined state
// Print data to the output window
cout << "The signal generator should now be in REMOTE. The remote indicator"<<endl;
cout <<"annunciator R should appear on the signal generator display"<<endl;
return 0;
}
Interface Check for GPIB Using VISA and C
This program uses VISA library functions and the C language to communicate with the signal 
generator. The program verifies that the GPIB connections and interface are functional. Launch 
Microsoft Visual C++ 6.0, add the required files, and enter the following code into your .cpp source 
file. visaex1.cpp performs the following functions:
• verifies the GPIB connections and interface are functional
• switches the signal generator into remote operation mode
The following program example is available on the signal generator Documentation CD-ROM as 
visaex1.cpp.
//****************************************************************************************
// PROGRAM NAME:visaex1.cpp
// 
// PROGRAM DESCRIPTION:This example program verifies that the GPIB connections and
// and interface are functional.
// Turn signal generator power off then on and then run the program
// 
//****************************************************************************************
#include <visa.h>
#include <stdio.h>
#include "StdAfx.h"
#include <stdlib.h>
void main ()
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# sample code for PDF to jpg image conversion. This demo code convert PDF file all pages to jpg images. // Define input and output files path.
change from pdf to jpg on; convert pdf pictures to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.Office.Inner.Office03.dll. RasterEdge.XDoc.PDF.dll. RasterEdge.XDoc. PowerPoint.dll. This demo code convert TIFF file all pages to jpg images.
convert pdf into jpg online; convert pdf images to jpg
Agilent Signal Generators Programming Guide
87
Programming Examples
GPIB Programming Interface Examples
{
ViSession defaultRM, vi;        // Declares a variable of type ViSession
// for instrument communication
ViStatus viStatus = 0;             
// Opens a session to the GPIB device
// at address 19
viStatus=viOpenDefaultRM(&defaultRM);
viStatus=viOpen(defaultRM, "GPIB::19::INSTR", VI_NULL, VI_NULL, &vi);
if(viStatus){
printf("Could not open ViSession!\n");
printf("Check instruments and connections\n");
printf("\n");
exit(0);}
viPrintf(vi, "*RST\n");         // initializes signal generator
// prints to the output window
printf("The signal generator should now be in REMOTE. The remote                        indicator\n");
printf("annunciator R should appear on the signal generator display\n");
printf("\n");
viClose(vi);                    // closes session
viClose(defaultRM);             // closes default session
}
Local Lockout Using HP Basic and GPIB
This example demonstrates the Local Lockout function. Local Lockout disables the front panel signal 
generator keys. basicex2.txt performs the following functions:
• resets instrument
• places signal generator into local
• places signal generator into remote
The following program example is available on the signal generator Documentation CD-ROM as 
basicex2.txt.
10    !*************************************************************************
20    !
30    !  PROGRAM NAME:         basicex2.txt
40    !
50    !  PROGRAM DESCRIPTION:  In REMOTE mode, access to the signal generators
60    !                        functional front panel keys are disabled except for
70    !                        the Local and Contrast keys.  The LOCAL LOCKOUT
80    !                        command will disable the Local key.
90    !                        The LOCAL command, executed from the controller, is then
100   !                        the only way to return the signal generator to front panel,
VB.NET Create PDF from images Library to convert Jpeg, png images
Components to batch convert PDF documents in Visual Basic .NET class. NET converter control for exporting high quality PDF from images.
best way to convert pdf to jpg; change file from pdf to jpg
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
Use C# Code to Convert Jpeg to Tiff. Define Jpeg images list. string[] imagePaths = { @"C:\demo1.jpg", @"C:\demo2.jpg", @"C:\demo3.jpg" }; // Construct List
convert .pdf to .jpg online; convert pdf to jpg 300 dpi
88
Agilent Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
110   !                        Local, control.
120   !*************************************************************************
130   Sig_gen=719       ! Declares a variable to hold signal generator address
140   CLEAR Sig_gen     ! Resets signal generator parser and clears any output
150   LOCAL Sig_gen     ! Places the signal generator in local mode
160   REMOTE Sig_gen    ! Places the signal generator in remote mode
170   CLEAR SCREEN      ! Clears the controllers display
180   OUTPUT Sig_gen;"*RST"       ! Places the signal generator in a defined state
190   ! The following print statements are user prompts
200   PRINT "The signal generator should now be in remote."
210   PRINT "Verify that the 'R' and 'L' annunciators are visable"
220   PRINT ".......... Press Continue"
230   PAUSE
240   LOCAL LOCKOUT 7   ! Puts the signal generator in LOCAL LOCKOUT mode
250   PRINT             ! Prints user prompt messages
260   PRINT "Signal generator should now be in LOCAL LOCKOUT mode."
270   PRINT 
280   PRINT "Verify that all keys including `Local' (except Contrast keys) have no effect."
290   PRINT 
300   PRINT ".......... Press Continue"
310   PAUSE
320   PRINT 
330   LOCAL 7           ! Returns signal generator to Local control
340   ! The following print statements are user prompts
350   PRINT "Signal generator should now be in Local mode."
360   PRINT 
370   PRINT "Verify that the signal generator's front-panel keyboard is functional."
380   PRINT 
390   PRINT "To re-start this program press RUN."
400   END
Local Lockout Using NI-488.2 and C++
This example uses the NI-488.2 library to set the signal generator local lockout mode. Launch 
Microsoft Visual C++ 6.0, add the required files, and enter the following code into your .cpp source 
file. niex2.cpp performs the following functions:
• all front panel keys, except the contrast key
• places the signal generator into remote
• prompts the user to verify the signal generator is in remote
• places the signal generator into local
The following program example is available on the signal generator Documentation CD-ROM as 
niex2.cpp.
// ************************************************************************************
Agilent Signal Generators Programming Guide
89
Programming Examples
GPIB Programming Interface Examples
// PROGRAM NAME: niex2.cpp
//
// PROGRAM DESCRIPTION: This program will place the signal generator into 
// LOCAL LOCKOUT mode. All front panel keys, except the Contrast key, will be disabled. 
// The local command, 'ibloc(sig)' executed via program code, is the only way to 
// return the signal generator to front panel, Local, control.
// ************************************************************************************
#include "stdafx.h"
#include <iostream>
#include "windows.h"
#include "Decl-32.h"
using namespace std;   
int GPIB0=   0;                            // Board handle
Addr4882_t Address[31];                    // Declares a variable of type Addr4882_t
int main()
{
int sig;                           // Declares variable to hold interface descriptor
sig = ibdev(0, 19, 0, 13, 1, 0);   // Opens and initialize a device descriptor
ibclr(sig);                        // Sends GPIB Selected Device Clear (SDC) message
ibwrt(sig, "*RST", 4);             // Places signal generator in a defined state
cout << "The signal generator should now be in REMOTE. The remote mode R "<<endl;
cout <<"annunciator should appear on the signal generator display."<<endl;
cout <<"Press Enter to continue"<<endl;
cin.ignore(10000,'\n');           
SendIFC(GPIB0);                    // Resets the GPIB interface
Address[0]=19;                     // Signal generator's address
Address[1]=NOADDR;                 // Signifies end element in array. Defined in 
// DECL-32.H
SetRWLS(GPIB0, Address);           // Places device in Remote with Lockout State. 
cout<< "The signal generator should now be in LOCAL LOCKOUT. Verify that all   
keys"<<endl;
cout<< "including the 'Local' key are disabled (Contrast keys are not 
affected)"<<endl;
cout <<"Press Enter to continue"<<endl;
cin.ignore(10000,'\n');
ibloc(sig);                        // Returns signal generator to local control
cout<<endl;
cout <<"The signal generator should now be in local mode\n";
return 0;}
}
90
Agilent Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
Queries Using HP Basic and GPIB
This example demonstrates signal generator query commands. The signal generator can be queried for 
conditions and setup parameters. Query commands are identified by the question mark as in the 
identify command *IDN? basicex3.txt performs the following functions:
• clears the signal generator
• queries the signal generator’s settings
The following program example is available on the signal generator Documentation CD-ROM as 
basicex3.txt.
10    !********************************************************************************
20    !
30    !  PROGRAM NAME:         basicex3.txt
40    !
50    !  PROGRAM DESCRIPTION:  In this example, query commands are used with response
60    !                        data formats.
70    !
80    !  CLEAR and RESET the controller and RUN the following program:
90    !
100   !********************************************************************************
110   !
120   DIM A$[10],C$[100],D$[10]   ! Declares variables to hold string response data
130   INTEGER B                   ! Declares variable to hold integer response data
140   Sig_gen=719                 ! Declares variable to hold signal generator address
150   LOCAL Sig_gen               ! Puts signal generator in Local mode
160   CLEAR Sig_gen               ! Resets parser and clears any pending output
170   CLEAR SCREEN                ! Clears the controller’s display
180   OUTPUT Sig_gen;"*RST"       ! Puts signal generator into a defined state
190   OUTPUT Sig_gen;"FREQ:CW?"   ! Querys the signal generator CW frequency setting
200   ENTER Sig_gen;F             ! Enter the CW frequency setting
210   ! Print frequency setting to the controller display
220   PRINT "Present source CW frequency is: ";F/1.E+6;"MHz"
230   PRINT 
240   OUTPUT Sig_gen;"POW:AMPL?"  ! Querys the signal generator power level
250   ENTER Sig_gen;W             ! Enter the power level
260   ! Print power level to the controller display
270   PRINT "Current power setting is: ";W;"dBM"
280   PRINT 
290   OUTPUT Sig_gen;"FREQ:MODE?" ! Querys the signal generator for frequency mode
300   ENTER Sig_gen;A$            ! Enter in the mode: CW, Fixed or List
310   ! Print frequency mode to the controller display
320   PRINT "Source's frequency mode is: ";A$
330   PRINT 
Agilent Signal Generators Programming Guide
91
Programming Examples
GPIB Programming Interface Examples
340   OUTPUT Sig_gen;"OUTP OFF"   ! Turns signal generator RF state off
350   OUTPUT Sig_gen;"OUTP?"      ! Querys the operating state of the signal generator
360   ENTER Sig_gen;B             ! Enter in the state (0 for off)
370   ! Print the on/off state of the signal generator to the controller display
380   IF B>0 THEN 
390     PRINT "Signal Generator output is: on"
400   ELSE
410     PRINT "Signal Generator output is: off"
420   END IF
430   OUTPUT Sig_gen;"*IDN?"      ! Querys for signal generator ID
440   ENTER Sig_gen;C$            ! Enter in the signal generator ID
450   ! Print the signal generator ID to the controller display
460   PRINT 
470   PRINT "This signal generator is a ";C$
480   PRINT 
490   ! The next command is a query for the signal generator's GPIB address
500   OUTPUT Sig_gen;"SYST:COMM:GPIB:ADDR?"
510   ENTER Sig_gen;D$            ! Enter in the signal generator's address
520   ! Print the signal generator's GPIB address to the controllers display
530   PRINT "The GPIB address is ";D$
540   PRINT 
550   ! Print user prompts to the controller's display
560   PRINT "The signal generator is now under local control"
570   PRINT "or  Press RUN to start again."
580   END
Queries Using NI-488.2 and Visual C++
This example uses the NI-488.2 library to query different instrument states and conditions. Launch 
Microsoft Visual C++ 6.0, add the required files, and enter the following code into your .cpp source 
file. niex3.cpp performs the following functions:
• resets the signal generator
• queries the signal generator for various settings
• reads the various settings
The following program example is available on the signal generator Documentation CD-ROM as 
niex3.cpp.
//*************************************************************************************
// PROGRAM NAME: niex3.cpp
//
// PROGRAM DESCRIPTION: This example demonstrates the use of query commands. 
//
// The signal generator can be queried for conditions and instrument states.
// These commands are of the type "*IDN?" where the question mark indicates 
92
Agilent Signal Generators Programming Guide
Programming Examples
GPIB Programming Interface Examples
// a query.
//
//*************************************************************************************
#include "stdafx.h"
#include <iostream>
#include "windows.h"
#include "Decl-32.h"
using namespace std;  
int GPIB0=   0;                          // Board handle
Addr4882_t Address[31];                  // Declare a variable of type Addr4882_t
int main()
{
int sig;                         // Declares variable to hold interface descriptor
int num;
char rdVal[100];                 // Declares variable to read instrument responses
sig = ibdev(0, 19, 0, 13, 1, 0); // Open and initialize a device descriptor
ibloc(sig);                      // Places the signal generator in local mode
ibclr(sig);                      // Sends Selected Device Clear(SDC) message
ibwrt(sig, "*RST", 4);           // Places signal generator in a defined state
ibwrt(sig, ":FREQuency:CW?",14); // Querys the CW frequency
ibrd(sig, rdVal,100);            // Reads in the response into rdVal
rdVal[ibcntl] = '\0';            // Null character indicating end of array
cout<<"Source CW frequency is "<<rdVal;   // Print frequency of signal generator
cout<<"Press any key to continue"<<endl;
cin.ignore(10000,'\n');
ibwrt(sig, "POW:AMPL?",10);      // Querys the signal generator
ibrd(sig, rdVal,100);            // Reads the signal generator power level
rdVal[ibcntl] = '\0';            // Null character indicating end of array
// Prints signal generator power level
cout<<"Source power (dBm) is : "<<rdVal; 
cout<<"Press any key to continue"<<endl;
cin.ignore(10000,'\n');
ibwrt(sig, ":FREQ:MODE?",11);    // Querys source frequency mode
ibrd(sig, rdVal,100);            // Enters in the source frequency mode
rdVal[ibcntl] = '\0';            // Null character indicating end of array
cout<<"Source frequency mode is "<<rdVal; // Print source frequency mode
cout<<"Press any key to continue"<<endl;
cin.ignore(10000,'\n');
ibwrt(sig, "OUTP OFF",12);       // Turns off RF source
Documents you may be interested
Documents you may be interested