IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
21 
3.6. General information regarding zone cooling and heating room units 
Local heating or cooling is supplied to the zone by room units. All room units are listed in the 
zone form. Some units such as ideal heaters and coolers, do not have a given location in the 
room. These can be introduced directly into the list in the zone form. Most hydronic units 
may, on the other hand, be located on a specific zone surface and they are instead inserted by 
dragging them onto a surface. From version 4.5, most hydronic units can also exist without a 
specific position in the zone, i.e they can be dragged directly into the zone form. Note, 
however, that all radiative units still require an explicit surface area. (Given on the Properties 
page, when the input form of the unit is active.) 
The temperature setpoint for cooling devices is normally taken directly from the Control 
setpoints, max value for Temperature
5
(see Figure 3.5). The corresponding value for heaters is 
the Temperature min value. However, from version 4.5, it is also possible for the Expert 
edition user to define any controller for an individual device. 
3.7. Ideal heaters and coolers 
Ideal room units should be used to condition the zone when no detailed information about an 
actual room unit, such as a fan coil or active chilled beam, is available or this amount of detail 
is unmotivated. They have no given physical location on any room surface and are not 
connected to the plant of the building. They do have a maximum capacity parameter, enabling 
the user to experiment with limited heating/cooling capacity. However, this parameter should 
normally be set to a large enough value to always cover any foreseen need. However, do not 
set the value to a totally unrealistic number, e.g., 100 times the reasonable heating load. This 
will result in poor control action. 
3.8. Hydronic heating devices 
Heat emission from hydronic heating devices is calculated using 
P = K*l*dT
N
where l is device length and dT is the temperature difference between the water and the zone 
air. K and 
N
are constants characterizing a device of a certain height (or width for ceiling 
devices).  
Figure 3.6 has a radiator inserted on a wall surface. Its main form has been opened and a 
dialog for alternative input has been opened from the form. Often the values of K
N
and 
Height come from a database (gray colored text in the form). The user must only enter the 
surface area (given graphically) and the design water flow. 
The warm radiator surface that is exposed to the zone is defined by the box that is drawn 
when the unit is inserted on a wall surface. The size of this box has meaning for the heat 
transfer. While the total emitted heat is always given by the expression for P, the division 
5
An exception is made when the air system is temperature controlled VAV. Cooling units in this case have their 
setpoints displaced by usually 2 °C. (Can be given centrally in System parameters). This means that the airflow 
is first forced to max value, after which the other cooling unit sets to work (assuming that free outside air cooling 
is often available). 
Pdf to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
c# pdf to jpg; convert pdf image to jpg online
Pdf to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert pdf file into jpg; convert multipage pdf to jpg
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
22 
between radiation and convection is calculated based on the surface temperature - which is 
connected to the water temperature - and the given exposed surface. The zone “sees” a warm 
surface and calculates the radiation and convection from this surface. The main part of the 
remaining heat (needed to complete P) is emitted convectively directly to the air 
(corresponding to convection behind a radiator). A small part of the heat goes to increase the 
temperature on the portion of wall behind the heating device. The heat transfer coefficient 
between the device surface and the wall behind is considered in the basic case to be 
completely dominated by radiation and is calculated by the model. 
Figure 3.6 A radiator on an external wall, its standard form, and a dialog for alternative input. 
To facilitate adding new heating devices without direct knowledge of K and 
N
, a possibility 
for alternative input is given (see Figure 3.6, lower box). The values for design mass flow and 
are calculated from the power given by the user at the specified temperature conditions. The 
user also provides a value for 
N
in this case. Note that K is calculated from the information 
given in the alternative input. This is thereafter the value for K. If the size of the graphical box 
is later changed, the device is likely to have an unintended maximum power. Note also that 
the actual maximum heating capacity of the device will vary with actual room and supply 
water temperatures. The temperature conditions given in Alternative data are only used to 
calculate K and have no impact on the simulated supply and return water temperatures
6
3.9. Cooling units  
The Cooling device is used for radiative and convective units. Cooling units operate 
completely analogous to waterborne radiators, with the exception of a few differences in 
input, which are discussed here. 
6
The actual water supply temperature is given by the boiler; the return temperature will vary with the actual 
massflow through the unit, the current room temperature and the size (K value) of the heating unit. However, if 
actual temperature conditions are made to coincide with those given in the dialog, exactly the given power will 
be emitted. 
Online Convert Jpeg to PDF file. Best free online export Jpg image
Download Free Trial. Convert a JPG to PDF. Web Security. All your JPG and PDF files will be permanently erased from our servers after one hour.
pdf to jpg; pdf to jpeg converter
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Download Free Trial. Convert a PDF File to JPG. Web Security. Your PDF and JPG files will be deleted from our servers an hour after the conversion.
convert pdf to jpg c#; convert pdf pages to jpg online
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
23 
Figure 3.7 A cooling panel on the ceiling surface, its standard form, and a dialog for 
alternative input. 
Here, the height of a radiator corresponds instead to a Module width, to which K and N refer. 
The total length is calculated as the given box area divided with Module width
7
. There is a 
difference in that the heat transfer coefficient between the back of the device, and the surface 
behind (often the ceiling) is given directly in the main form. If an (arbitrary) negative figure is 
entered, the heat transfer coefficient is calculated in the same way as for the heating device, 
i.e. as if all heat transfer was done by radiation. This is a good approximation for a device that 
has no insulation at all.  
The dialog for alternative input has somewhat different parameters for cooling units. 
Absorbed power and temperature differences between air and water may be given for two 
points on the power curve. For max power, the temperature drop of the water is also given. 
3.9.1. 
Active beams 
Active beams serve both as supply air terminals and as cooling devices with significant 
convection. Their performance depends on the amount of supply air that is passed through but 
they normally retain a heat transfer contact with room air also in the case of zero supply air 
flow. The radiative coupling with the room is neglected in the present model. Beams are 
mostly used for cooling but may also heat the room air. 
Two input data options are available: Simplified and Manufacturer’s. The latter means that 
the performance parameters K and 
N
are given as functions of air flow. This alternative is 
mostly used when data is automatically imported from an on-line manufacturer’s database or 
from IDA Room. The Simplified option is based on two user supplied performance points, at 
design conditions and at zero flow (Figure 3.8). 
N
is for this case set to 1.5. 
7
The same is done for the radiator. 
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
String inputFilePath = @"C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg. C# sample code for PDF to jpg image conversion.
convert pdf pages to jpg; best program to convert pdf to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.PDF.dll. String inputFilePath = @"C:\input.tif"; String outputFilePath = @"C:\output.jpg"; // Convert tiff to jpg.
convert pdf image to jpg; changing pdf to jpg on
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
24 
Figure 3.8 Active beam form 
In the constant flow (CAV) case, the given Design air flow is regarded to pass through the 
beam whenever fans are running. For VAV, the constant Design air flow will pass through the 
beam whenever there is sufficient air into the room and surplus air will feed directly to the 
room without first passing the beam. If the VAV flow is insufficient to serve the beam with 
the full requested Design flow, the flow through the beam will reduced accordingly. 
The total Design air flow through all beams must not exceed the total for the zone. If beam air 
flow is less than the requested total for the zone, the remaining part is regarded as being 
supplied through conventional terminals. 
When the flow to the room is increased by forcing the central fan (or similarly reduced) the 
beams will still keep their requested Design flow, as far as possible. 
3.9.2. 
Heating/Cooling floor (Expert edition) 
If a floor heating/cooling object is inserted on the floor of a zone, the floor construction for 
this area is divided into two parts, above and below the heated layer. Between the two, a heat 
exchanger model is inserted corresponding to the piping layer. Quite often a floor heating 
circuit will heat the room below almost as much as the room it belongs to. 
The floor coil model assumes that the active layer can be treated as an infinitely conductive 
plane in the floor slab, i.e. all 2D effects are disregarded. Heat transfer is calculated with a 
logarithmic temperature difference between the fluid and this plane of constant temperature. 
The user supplied total heat transfer coefficient between the fluid and the plane, includes 
1. Convection between medium and tube wall 
2. Heat conduction through the tube walls  
3. “Fin efficiency” corresponding to the distance between immersed tubes or actual fins. 
The modeling approach will in steady state correspond to the Resistance method of the 
standard EN 15377-1.  
The floor coil circuit can have its own three-way valve and pump circuit keeping the 
massflow constant (default). Emitted power is then controlled by varying the supply water 
temperature. PI, P or on-off control can be selected (PI is default). A further alternative 
Always on is also available, which will keep both the boiler mass flow and the coil circulation 
massflow permanently at their design values. Control must then be maintained by the boiler 
temperature controller. 
JPEG to PDF Converter | Convert JPEG to PDF, Convert PDF to JPEG
similar software; Support a batch conversion of JPG to PDF with amazingly high speed; Get a compressed PDF file after conversion; Support
pdf to jpeg; convert from pdf to jpg
JPG to JBIG2 Converter | Convert JPEG to JBIG2, Convert JBIG2 to
Image Converter Pro - JPEG to JBIG2 Converter. Convert JPEG (JPG) Images to, from JBIG2 Images on Windows.
.net pdf to jpg; change pdf to jpg online
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
25 
In the case where no separate coil pump circuit is used, the four control options will instead 
act by limiting the massflow through the coil, or keeping it constant at design conditions in 
the Always on case. 
Figure 3.9 Floor heating form 
JPG to GIF Converter | Convert JPEG to GIF, Convert GIF to JPG
Converter. Convert JPEG (JPG) Images to, from GIF Images on Windows. JPEG to GIF Converter can directly convert GIF files to JPG files.
change from pdf to jpg; change pdf to jpg image
JPG to DICOM Converter | Convert JPEG to DICOM, Convert DICOM to
Image Converter Pro - JPEG to DICOM Converter. Convert JPEG (JPG) Images to, from DICOM Images on Windows.
convert pdf to 300 dpi jpg; .pdf to .jpg converter online
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
26 
4. CAD and image import 
In IDA Indoor Climate and Energy it is possible to import CAD objects and image files. 
These can be used as a base when creating the simulation model, or as shading elements that 
cast shadows onto the simulation model. There are three categories of CAD objects and image 
files; building information models (BIM), CAD and vector graphic files, and image files.  
BIM files contain 3D geometry as well as properties for walls, windows and materials etc. An 
IDA ICE model, i.e. building bodies, zones and windows etc., can be automatically created 
from the geometrical information. Furthermore, the properties of objects in the BIM file can 
be mapped to the corresponding objects in the simulation model. The 3D geometry of a BIM 
file can also be selected to shade the simulation model.  
CAD and vector graphic files contain 3D or 2D geometry. A section of this geometry is 
shown as lines in the floor plan tab and these lines can be used to snap building bodies and 
zones etc. in the floor plan. Building bodies and zones can be automatically created from 
graphic files if the imported geometry consists of volumes enclosed by polygon surfaces. 3D 
CAD objects can be selected to shade the simulation model.  
Image files contain raster (bitmap) images. These are shown in the floor plan tab when the 
section is close to the location of the image. The images can be used as a background when 
drawing building bodies and zones in the floor plan or when inserting windows and shading 
objects in the 3D view. 
4.1. Supported file formats 
4.1.1. BIM 
Industry Foundation Classes (*.ifc) 
4.1.2. CAD and vector graphic files 
AutoCAD (*.dwg
8
, *.dxf, *.dwf)  
SketchUp (*.skp) 
3D Studio (*.3ds) 
Wavefront (*.obj) 
Computer Graphics Metafile (*.cgm) 
Corel Presentation Exchange (*.cmx) 
MicroStation DGN (*.dgn) 
Micrografx DRW (*.drw) 
Gerber File Format (*.gbr) 
Scalable Vector Graphics (*.svg) 
Printer Command Language (*.pcl, *.prn, *.prt) 
Macintosh PICT (*.pct) 
HP-GL/HP-GL2 (*.plt) 
8
IDA ICE supports DWG file formats up to AutoCAD 2004. DWG files of unsupported formats can be 
converted with the free tool Autodesk DWG TrueView. DWG files are assumed to be two-dimensional, i.e. any 
3D geometry is flattened to 2D at import. 
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
27 
WordPerfect Graphics (*.wpg, *.vwpg) 
4.1.3. Image files 
Bitmap (*.bmp) 
JPEG Interchange Format (*.jpeg,*jpg) 
Portable Networks Graphics (*.png) 
ZSoft PC Paint (*.pcx) 
Tagged Image File Format (*.tiff,*.tif) 
Adobe Photoshop (*.psd) 
Truevision (*.tga) 
Windows Meta File (*.emf,*.wmf) 
4.2. 
Importing IFC files 
In IDA ICE it is possible to import 3D building information models (BIM) via IFC files. Most 
3D CAD applications can export architectural data in the IFC format. 
The most important information that is transferred is geometrical data, i.e. the shape and 
position of zones, windows, doors, building faces etc. Zones in IDA ICE are automatically 
created from so called space objects in the IFC model. It is not sufficient that the CAD model 
only contains wall objects, spaces that fill the voids between walls must also have been 
created, a semi-automatic process in most CAD tools. 
IDA ICE can also utilize other types of information in the CAD model, such as wall 
constructions, should they be present. One can find more detailed information about the ICE 
IFC implementation on the user’s page: Help menu, IDA on the Web, ICE User support. 
Select Users’ notes on the page and open the document ‘IFC Import’. 
4.3. Mapping data from IFC 
Start with a building without zones and select the Floorplan tab. Press IFC… > Import… to 
select an IFC file for loading. There are some sample IFC files in the installation, normally 
located in 
C:\Program Files\IDA\samples\ICE\IFC
The first task is to map named data objects in the IFC model (if any are present) to 
corresponding IDA resources. Press IFC… > Mapping… in the Floorplan tab to open the 
Mapping dialog (Figure 4.1). If wall constructions have not been described in detail in the 
CAD model, select directly Constructions in the Category combo box. This will present a list 
of all wall types that have been found in the IFC model. Since IDA ICE needs more detailed 
information about a wall, IFC wall types need to be manually associated with IDA ICE wall 
constructions. To bind a certain IFC wall type to an IDA ICE construction, select both the IFC 
wall type and the corresponding ICE resource and press Map to selected. A right pointing 
arrow in the IFC Data list indicates that the item has been bound. Usually one first has to load 
relevant IDA ICE resources from the database by pressing Load from Db. To inspect the 
selected IDA resource, press View. 
Repeat the procedure for window types as well. Here, one usually has to first create relevant 
windows in the ICE database, including internal shadings etc. 
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
28 
If wall constructions have been described in the IFC model with layer thicknesses and 
material names, one can automatically create corresponding IDA ICE constructions. In this 
case, one starts instead with binding IFC material names with IDA ICE material resources. 
Once the materials have been mapped, IDA ICE wall construction resources are created by 
pressing Import from IFC when the relevant IFC wall type has been selected. 
Any object in the IFC model which is not explicitly mapped to an IDA resource will be set to 
its default value, which is given by pressing Defaults on the General tab in the building form. 
Figure 4.1 IFC Mapping dialog 
4.4. Create zones from IFC spaces 
An IFC model may contain more than a single floor. A horizontal section (slice) of the 
building at a certain level is shown in the Floorplan tab (Figure 4.2). To select a different 
level, press the button Level: xx m, where xx is the floor height from ground of the current 
level. In the Level dialog, the building height from ground (Building top) and height 
coordinate of the floor slab with respect to ground (Building bottom) are also shown, as 
interpreted from the IFC file. These numbers are not always correct for the user’s purpose. 
To define which spaces in the IFC model that should constitute a (thermal) zone in the 
simulation model, click on (select) the neighboring spaces that should be included. (Click 
again to unselect a space.) Think about zone economy, i.e. do not create more zones than you 
think is physically motivated for the current study. To create an IDA ICE zone from the 
selected IFC spaces, press New zone
9
. This will create zones using the currently selected zone 
template. Try to give as many reasonable defaults as possible for new zones using appropriate 
zone templates; after creation these values must be edited separately for each created zone. 
9
By default an individual zone is created for each selected IFC space. Optionally, all the selected spaces can be 
merged (if they have the same floor and ceiling level) into larger zones. This setting is found under the ‘IFC’ 
button 
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
29 
Figure 4.2 IFC model with an ICE zone, a selected IFC space and unselected IFC spaces. 
The IDA ICE zones are created from the geometry of the corresponding IFC space(es). If for 
example a space is taller than the typical floor to floor distance of the building, the 
corresponding ICE zone will also reach over more than a single floor. One can change the 
horizontal section level during the zone creation process but it is currently not possible to 
combine several spaces vertically into a single zone. Note that the Floorplan view displays 
two models simultaneously, the zones of the created ICE model and the spaces of the IFC 
model. Both categories of “rooms” can be individually selected and ICE zones can also be 
opened. 
If the IFC model is revised during the ICE modeling project, there is some support for 
retaining previous work. New IFC models can be loaded while modeling, either replacing the 
existing model or adding to it, e.g. loading several floors that are in separate IFC files. When 
a new file is loaded, the user is given the option to replace or add to the current IFC model 
and to replace or keep mapping information and existing ICE zones. 
If the IFC information is incomplete or too complex for some part of the building, the user 
can simply avoid to instantiate these zones based on IFC background and draw them manually 
on the floor plan. 
4.5. Importing CAD objects as building bodies or zones 
CAD objects can be imported as building bodies or zones if the imported geometry only 
contains a volume enclosed by polygon surfaces (polyhedron) without holes between the 
surfaces. The geometry should describe the inner surface of the external walls for a building, 
and the inner surface of the zone walls for a zone. No other information than the pure 
geometry of the building body or zone can be included in the CAD object. Click Import… on 
the floor plan tab and choose Import building body… or Import zone geometry…. 
IDA Indoor Climate and Energy 4.5 
© EQUA Simulation AB 2013 
30 
Imported building bodies and zones have protected geometry, i.e. their geometry is non-
editable. However, an imported building body is fully editable if the imported geometry only 
has one floor and that floor is horizontal and does not contain any holes, and the geometry 
does not have any outward leaning walls (surfaces with their exterior normal pointing 
downwards). This is the same kind of geometry that can be created in the ICE roof editor. 
Importing geometry as zone will also create a building body of the same shape as the zone. 
If a geometry file contains multiple polyhedron geometries, each with a separate color, they 
are imported as separate building bodies or zones in ICE. If surfaces are placed one wall 
thickness apart, these are regarded as thermally connected internal walls. 
4.6. Importing CAD objects and images as background 
CAD objects and image files are either imported with respect to the building coordinate 
system, and are then moved with the building if the building is repositioned or rotated, or they 
are imported with respect to the site coordinate system, and remain fixed if the building is 
repositioned or rotated. 
Import a CAD object/image file with respect to the building coordinate system by clicking the 
Import button on the floor plan tab and choosing CAD and vector graphic. Alternatively, 
select Import CAD on the Insert menu while the 3D tab is shown. 
Import a CAD object/image file with respect to the site coordinate system by clicking the 
Import site CAD button on the Site object dialog opened by clicking Site shading and 
orientation on the General tab. Alternatively, select Import CAD to site on the Insert menu 
while the 3D tab is shown. 
To place a CAD object/image at the current mouse pointer in the 3D view, use Right mouse 
button menu > Import CAD or Right mouse button menu > Import CAD to site. 
4.7. Moving and scaling CAD objects and images 
A CAD object is automatically scaled and positioned so that it corresponds to the simulation 
model. The scale and position of a CAD object can be seen and edited by double-clicking on 
the object. A section of the CAD object or image is shown in the floor plan tab if the floor 
plan level is within the bounds of the object. Select this section by clicking on it
10
. Move and 
change size of the CAD object/image by dragging/resizing the section. 
A CAD object can also be moved in the 3D view. Select the CAD object, hold down the ctrl-
key and drag the object. The object moves in the x-y plane. To move a CAD object along the 
z-axis, hold down the ctrl-key and the shift-key while dragging. 
4.8. Shading by imported 3D objects 
3D CAD objects can be selected to shade the simulation model. Check the Calculate shadows 
checkbox in the dialog shown when the object is double-clicked. Every non-transparent 
surface of the 3D object is included in the shadow calculation and visualization. 
10
To select a CAD object, click on the geometry lines. To select an object that is behind another object, press the 
ctrl-key and click on the object until it is selected. 