20 -EN
INSTALLATION AND CONFIGURATION MANUAL
FOR AURORA WIND INVERTERS
10.1  sElEcTiON OF gRiD sTANDARD
When the inverter starts up for the first time it asks you to select the “Nation” of the country where it has 
been installed.
Use the keys on the display to scroll and select one of the Nations listed in the following table:
Warning! Select the grid standard carefully to avoid any problems with the grid connection. 
Theselection of the grid standard automatically configures the inverter to ensure that it complies 
with local standards.
After you have selected the required Nation, press ENTER: you will be requested to confirm your choice by 
holding down the ENTER key for 5 seconds.
Warning! From the moment that the grid standard is set you have 24 hours to make any changes to 
the value, after which the “Nation Select” functionality is blocked, and any subsequent changes can 
only be made using a password provided on request by Power-One.
Note: In the event that an error is made in the selection of the Nation value, it is possible, during the first 24hours 
when the inverter is powered*, to modify the Nation value by selecting:    settings  -> Nation -> Nation select.
10. possible configurations required at start up
Below is a list of possible configurations that may be required at the inverter’s start-up. Other configurations 
are possible, these are not strictly related to the inverter’s start-up and for them you should refer to the User 
Manual. The following configurations can be modified with the four keys on the display (Esc, Up, Down and 
Enter); by pressing the Up and Down keys you go from one item to another or scroll the numerical scale, by 
pressing the Esc key you return to the previous menu and by pressing the Enter key you go to the sub-menu 
corresponding to the selected item or you go to the next figure to modify. To access the following functions, 
you have to open the “Settings” item from the main menu, entering the password which is 0000 by default.
NATiON (displayed)
lANguAgE
No Nation (No Nation)
English
Australia (Australia)
English
BENELUX (Benelux)
French
China (China)
English
Czech Rep. (Czech Rep.)
Czech
France (France)
French
Germany (Germany)
German
Greece (Greece)
English
Ireland (Ireland)
English
Italy (Italy)
Italian
Portugal (Portugal)
English
Spain (Spain)
Spanish
UKG59/2 (United Kingdom)
English
UKG83/1 (United Kingdom)
English
Convert pdf to jpeg on - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf file into jpg; change pdf to jpg file
Convert pdf to jpeg on - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
bulk pdf to jpg; convert pdf to jpg file
21 - EN
EN - ENglish
Wind inverters
10.2  OThER cONFiguRATiONs
configuration of the Rs458 port address (Address): When there are several inverters wired on the 
same RS485 line (ref. Par. 6), the RS485 port address must be different for each inverter (N.B. “Auto” is not 
permitted as an address); to modify the address you have to access the Address sub-menu.
Date/Time settings (Time):  On first start-up of the inverter, it is necessary to configure the date and time 
by accessing the Time sub-menu.
language setting (language):  If required, you can change the default language, set automatically 
when “Nation” was selected, to one of the following: ENGLISH, GERMAN, FRENCH, ITALIAN, SPANISH, 
CZECH or DUTCH.
To change the language, select the Language submenu.
start-up voltage (Vstart): The start-up voltage can be regulated by accessing the Vstart sub-menu.
You can check how much time remains before the “Nation Select” button is blocked, by selecting  
settings -> Nation -> Remaining Time.
After 24 hours* the inverter is powered, you can only change the Nation setting using a password provided 
on request by Power-One. To request this password, contact the Service Power-One and communicate the 
serial number (S/N) of the inverter and its “Authorization Key” code, which can be obtained by selecting 
settings -> Nation -> Nation select.
After obtaining the password, select settings -> Nation -> Nation select , press ENTER and enter the 
password supplied by Power-One.
* The 24 hour period begins (and continues) when you select a Nation
Online Convert Jpeg to PDF file. Best free online export Jpg image
Online JPEG to PDF Converter. Download Free Trial. Convert a JPG to PDF. You can drag and drop your JPG file in the box, and then start
batch convert pdf to jpg; advanced pdf to jpg converter
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
convert pdf pages to jpg; reader convert pdf to jpg
22 -EN
INSTALLATION AND CONFIGURATION MANUAL
FOR AURORA WIND INVERTERS
11. start-up Troubleshooting
Start-up Troubleshooting concerns the solving of the main problems that can occur during the first 
start-up phase.
Should problems arise in the unit’s commissioning phase, it is possible to solve the problem by looking for the 
corresponding problem in the table and following the instructions.
Warning! Tampering with the unit, even to solve a problem, leads to the loss of the unit’s warranty. Before 
undertaking any tampering that could cause the loss of warranty, contact the Power-One customer 
assistance service.
problem
possible causes
checks/possible solutions
The inverter does not connect to 
thegrid
Displayed message:
W009 Empty Table 
Green LED: OFF
Yellow LED: FLASHING
Red LED: OFF
Wind turbine power curve 
missing.
• Load the power curve into the 
inverter (see Chapter 9.1).
The inverter does not start.
Display message: none
Green LED: OFF
Yellow LED: OFF
Red LED: OFF
There is no input voltage (DC) 
present or it is present but 
with reversed polarity.
• Check the status of any external 
switches.
• Check the status of any external 
fuses.
• Check the inverter input voltage 
polarity.
• Check that the input voltage 
is greater than 50V (see the 
technical characteristics).
The inverter does not establish 
parallel with the grid.
Display message: Missing Grid
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
There is no grid voltage.
• Check the status of the AC side 
disconnecting switch.
• Check the inverter’s AC side 
connections (ref. chapter 5.1) 
and repeat the commissioning 
procedure.
The inverter does not establish 
parallel with the grid.
Display message: PARAMETERS 
OUTSIDE TOLERANCE.
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
Faulty grid cable connection. . • Check the inverter’s AC side 
connections (ref. chapter 5.1) 
and repeat the commissioning 
procedure.
C# Create PDF from images Library to convert Jpeg, png images to
C# Example: Convert More than Two Type Images to PDF in C#.NET Application. This example shows how to build a PDF document with three image files (BMP, JPEG and
convert pdf to jpg for; conversion pdf to jpg
C# PDF Convert to Images SDK: Convert PDF to png, gif images in C#
Besides raster image Jpeg, images forms like Png, Bmp, Gif, .NET Graphics, and REImage (an You can use this sample code to convert PDF file to Png image.
convert pdf image to jpg; convert pdf file into jpg format
23 - EN
EN - ENglish
Wind inverters
problem
possible causes
checks/possible solutions
The inverter does not establish 
parallel with the grid
Display message: W003 Grid Fail
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
Faulty grid cable connection.
One or more grid parameters 
are outside the range permitted 
for connection to the grid.
• Check the inverter’s AC side 
connections (ref. chapter 5.1) 
and repeat the commissioning 
procedure.
• Check that the grid voltage, at 
terminal block heads, is within 
the range (width and frequency) 
permitted for the inverter’s 
operation and repeat the 
commissioning procedure.
• If this error is frequently repeated, 
consult the user manual for 
further information.
The inverter does not establish 
parallel with the grid.
Display message: W003 Grid Fail
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
The grid voltage exceeds the 
maximum operating value 
(264V L-N).
Contact Power-One Support 
Service.
The inverter does not establish 
parallel with the grid.
Display message: E013 Wrong 
Mode.
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
Faulty configuration of the 
input channels: the inputs on 
the inverter have not been 
short-circuited.
• Check the status of the jumpers 
between the input channels (ref. 
chapter 5.2).
VB.NET PDF Convert to Tiff SDK: Convert PDF to tiff images in vb.
Resize converted Tiff image using VB.NET. Convert PDF file to Tiff and jpeg in ASPX webpage online. Online source code for VB.NET class.
convert pdf file to jpg online; .net pdf to jpg
VB.NET PDF Convert to HTML SDK: Convert PDF to html files in vb.
Convert PDF to HTML. |. Home ›› XDoc.PDF ›› VB.NET PDF: PDF to HTML. Convert PDF to HTML in VB.NET Demo Code. Add necessary references:
convert pdf document to jpg; c# pdf to jpg
24 -EN
INSTALLATION AND CONFIGURATION MANUAL
FOR AURORA WIND INVERTERS
problem
possible causes
checks/possible solutions
The inverter does not establish 
parallel with the grid.
Display message: E 025 Riso Low.
Green LED: OFF
Yellow LED: OFF
Red LED: ON
Insulation resistance to the wind 
turbine <1Mohm.
• Check the inverter’s DC side 
connections (ref. chapter 5.2) 
and repeat the commissioning 
procedure.
• Check the adequacy and status 
of the devices used externally 
for protection against transitory 
over voltage. Remove them and 
retry. If necessary, replace them.
• If this error is frequently 
repeated, see the application 
note “Riso and Ileak Troubles 
Solving Guide” provided on the 
supplied CD.
The inverter does not establish pa-
rallel with the grid.
Display message: E018.
Green LED: OFF
Yellow LED: OFF
Red LED: ON
The inverter detects excessive 
dispersion current to earth.
• Carry out the same checks as in 
the previous point.
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
Convert PDF to HTML. |. C#.NET PDF SDK - Convert PDF to HTML in C#.NET. How to Use C# .NET XDoc.PDF SDK to Convert PDF to HTML Webpage in C# .NET Program.
changing pdf to jpg; convert .pdf to .jpg online
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Sometimes, to convert PDF document into BMP, GIF, JPEG and PNG raster images in Visual Basic .NET applications, you may need a third party tool and have some
.pdf to .jpg converter online; convert pdf to 300 dpi jpg
25 - EN
EN - ENglish
Wind inverters
problem
possible causes
checks/possible solutions
intervention of the 
magneto-thermal 
differential switch 
downstream the inverter.
Display message: W003 Grid Fail
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
Faulty grid cable connection.
Faulty switch sizing.
Faulty sizing of the differen-
tial protection.
Intervention of the devices 
external to the inverter for 
protection from transitory 
overvoltage.
Damage to the devices for 
protection against transitory 
overvoltage on the inverter’s 
AC side.
• Check the connections on the 
inverter’s AC side (ref. chapter 5.1).
• Check that the switch’s rated voltage 
is (at least) equal to the inverter’s 
maximum output voltage.
• Check that the differential protection 
downstream the inverter is A/AC 
type with a sensitivity of not less than 
300mA.
• Check the adequacy and status of 
the protection devices used. Remove 
them and retry. If necessary, replace 
them.
• Check the status of the inverter’s 
output varistors; remove them and 
retry. If necessary, replace them.
The inverter does not establish 
parallel with the grid
Display message: Waiting Wind
Green LED: FLASHING
Yellow LED: ON
Red LED: OFF
The inverter’s input voltage is 
less than the start-up voltage.
• Check that the voltage at the input 
connectors is greater than the start-up 
voltage.
• Check that the wind conditions are 
sufficient for the commissioning phase 
of the system.
• Check the connections to the wind 
turbine and those on the DC side of the 
inverter.
The inverter does not commu-
nicate through the Rs485 port.
Display message: none.
Faulty communication line 
connection.
Faulty assignment of 
addresses to the inverters.
Faulty assignment of 
communication speed (baud-
rate).
Use of an inappropriate signal 
converter.
• Check the connections between 
the inverters and to the monitoring 
system (ref. chapter 6) and the 
termination of the communication 
line.
• Check that each inverter has different 
address to the others.
• Check that each inverter has the 
baud-rate set at 19200bps.
• Power One recommends the 
purchase of the PVI-RS485_RS232 or 
PVI-USB-RS485_232 converter.
• If the PVI-USB-RS485_232 converter 
is used, check that the output is set 
correctly.
26 -EN
INSTALLATION AND CONFIGURATION MANUAL
FOR AURORA WIND INVERTERS
12. Troubleshooting help
If it has not been possible to solve the problem through the start-up troubleshooting (ref. Par. 10) and the 
complete troubleshooting in the user manual, the following procedure should be followed:
If you have not been able to remove the malfunction, contact customer service or the installer to request 
assistance.
Before contacting customer service make sure the following information is available in order to maximize the 
effectiveness of the intervention:
information on the inverter:
• Aurora inverter model.
• Serial number
• Week of production
information about the wind turbine:
• Make and model of the wind turbine
• Type of power curve (frequency or voltage)
• Whether a controller is in use (Rectifier)
• Type of controller (Rectifier)
Note: it is advisable to use the special “SYSTEM STRUCTURE” form on the next page to collect this information so 
the information is always available in case of need.
Brief description of the fault.
Can the fault be reproduced? If so, how?
Does the fault repeat itself in cycles? If so, how often?
Was the fault apparent at the moment of installation? If so, has it got worse?
What are the atmospheric conditions when the fault occurs?

Check that connections between the Aurora, the wind turbine and the grid have been correctly carried out.
Carefully observe which of the LED is flashing or is stably lit and the notice text appearing on the display, 
with particular reference to the error code.
Errors and warnings log file obtained from the software Aurora Installer or Aurora Communicator (Refer to 
the Aurora Communicator manual).
27 - EN
EN - ENglish
Wind inverters
AuRORA iNVERTER
Model (*):
Serial Number (*):
Week of production (*):
WiND TuRBiNE
- Make and model of the wind turbine: ...................................................................................................................
- Type of power curve (frequency or voltage):.......................................................................................................
- Whether a controller is in use (rectifier): ...............................................................................................................
- Type of controller (rec.......................................................
sYsTEm sTRucTuRE
You are recommended to fill in this page with the information relating to the system and possibly supplement 
it with a copy of the system’s wiring diagram. The information on this page could be very handy, should it be 
necessary to contact the Power One help service.
(*) Refer to the product’s identification label on the right side of the inverter.
Date of installation:     
.........................................
Date of commissioning:      
.........................................
Stamp / Signature of installer (*):
(*) This document has no contractual value between the owner of the system and the installer.
APPENDIX
AppENDiX  A –  piN-OuT OF  RJ12 / RJ45 cONNEcTORs
RJ12 connectors
pin #
signal 
Name
Description
1
Not 
used
2
+TR
+ Data line
Required for RS485 communication.
3
+R
Remote OFF
Required or Remote OFF control
4
-TR
- Data line
Required for RS485 communication.
5
Not 
used
6
RTN
signal Return
Common reference for logical signals.
RJ45 connectors
pin #
signal 
Name
Description
1
Not used
2
Not used
3
+TR
+ Data line
Required for RS485 communication.
4
+R
Remote OFF
Required or Remote OFF control.
5
-TR
- Data line
Required for RS485 communication.
6
Not used
7
RTN
signal Return
Common reference for logical signals.
8
Not used
Wind inverters
AppENDiX B – cABlE WiRiNg DiAgRAm FOR Rs485 liNE
Documents you may be interested
Documents you may be interested