You use the left pane in this display to add up to 200 rack access cards for the selected
device group, or NetBotz Appliance or Appliances, and assign users to those cards. You
then select a card in the left pane, and select a device group, NetBotz Appliance, Rack
Access Pod 170, or door in the right pane to enable, disable, or schedule the rack access
for that card.
When no HID cards proximity cards have been registered for the selected NetBotz
Appliance, the "NetBotz Appliance Settings" display appears when you access the  Rack
Access Settings option. This display allows you to specify the supported card type and
auto lock timeout for the selected appliance.
You can access the "NetBotz Appliance Settings" display from the  NetBotz Appliance
Settings link to modify the  Auto Lock Timeout only. To modify the supported card type,
you must first remove all the cards associated with the appliance.
When one or more rack access cards swiped at a Rack Access Pod 170 device have not
been registered to the associated NetBotz Appliance, the  Show Unregistered Cards link
is displayed. You can access the "Unregistered Cards" display from the link to select the
rack access cards you want to register, or remove cards you do not want to register from
the list.
Left pane:
Element
Description
List
Card ID#: The identification number
assigned to the card.
User name: The user name assigned to the
card.
Add
Select to add a rack access card to the list.
Edit
Select to modify the username, description, or
authorization level for the selected card.
Remove
Select to remove a card from the list.
Note:  You must press  Apply or  OK to save the
changes.
Copy
Select to copy the scheduled access of the
selected card to one or more additional cards.
Right pane:
Element
Description
Card ID#
Displays the card ID # selected in the table at left,
the associated user name, description, and
whether a swipe from an additional card is
required to authorize rack access.
Note:  The additional card must not require an
authorization card swipe.
List
Door: Select a device group, NetBotz
Appliance, or Rack Access Pod 170 device,
or check mark one or more doors to
schedule access for the card selected.
Scheduled Access: Icons for each door
indicate whether access is scheduled 24
StruxureWare Data Center Expert 7.2.1
251
Convert pdf to jpg for online - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
best pdf to jpg converter online; convert pdf file to jpg
Convert pdf to jpg for online - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
change pdf to jpg file; .pdf to jpg converter online
hours a day, 7 days a week ( full green icon),
some of the time (half green icon), or
disabled (white icon).
Enable
Select to schedule door access 24 hours a day,
7 days a week for the selected device group,
NetBotz Appliance, Rack Access Pod 170
device, or door.
Disable
Select to disable door access 24 hours a day, 7
days a week for the selected device group,
NetBotz Appliance, Rack Access Pod 170
device, or door.
Edit Access
Select to modify weekly door access for the
selected device group, NetBotz Appliance, Rack
Access Pod 170 device, or door.
You can use the right-click options in the right pane to do the following:
• Enable or disable rack access 24 hours a day, 7 days a week for the selected device
group, NetBotz Appliance, Rack Access Pod 170 device, or door ( Enable or
Disable option).
• Schedule weekly rack access for the selected device group, NetBotz Appliance, Rack
Access Pod 170 device, or door ( Edit option).
• Expand or collapse the list for the selected device group, NetBotz Appliance, or Rack
Access Pod 170 device ( Expand or  Collapse option).
• Select every door for every NetBotz Appliance in the list ( Select All Doors option).
• Select every Door 1 door for the selection ( Select All Door 1 Doors option).
• Select every Door 2 door for the selection ( Select All Door 2 Doors option).
Note:  To lock and unlock the doors, you use the  Rack Access Control option, available
in the right-click menu of the  Device View or  Map View for the selected controllable
NetBotz Appliance or NetBotz Rack Access Device.
"NetBotz Appliance Rack Access Settings" display
Use this display to identify the HID proximity card type used for the selected NetBotz
Appliance, and specify the auto lock timeout. All cards registered to the NetBotz Appliance
must use the same card type.
The "NetBotz Appliance Rack Access Settings" display appears the first time you access
the  Rack Access Settings option for a selected NetBotz Appliance. You can specify one
of four supported HID proximity card types:
• H10301 - Standard 26-bit
• H10302 - 37-bit without a facility code
• H10304 - 37-bit with a facility code
• CORP1000 - Corporate 1000
You can access the display again, if needed, from the  NetBotz Appliance Settings link
in the "Rack Access Settings" display. You can modify the  Auto Lock Timeout only. To
modify the supported card type, you must first remove all the cards associated with the
appliance.
The  Auto Lock Timeout determines how long the device will wait (10 - 60 seconds) until
it automatically locks the rack door after a card, a key, or a remote command is used to
unlock it. If the door is open or the handle is up after the timeout expires, the device will
issue the lock command until the door is closed and the handle is down.
StruxureWare Data Center Expert 7.2.1
252
Online Convert Jpeg to PDF file. Best free online export Jpg image
Online JPEG to PDF Converter. Download Free Trial. Convert a JPG to PDF. You can drag and drop your JPG file in the box, and then start
changing pdf file to jpg; bulk pdf to jpg converter online
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
pdf to jpg converter; reader pdf to jpeg
Additionally, the  Auto Lock Timeout limits the time the device will wait for a second
authorizing card swipe after a rack access card that requires authorization is swiped.
Element
Description
Card Type
The type of HID proximity card registered to the
NetBotz Appliance selected. You can specify the
card type once only.
Auto Lock Timeout
Specify the time the device will wait until it
automatically locks the rack door after a card, a
key, or a remote command is used to unlock it
(10 - 60 seconds).
"Unregistered Cards" display
Use this display to register one or more rack access cards swiped at a Rack Access Pod
170 device, and not registered to the associated NetBotz Appliance.
Note:  You access this display from the "Rack Access Settings" display  Show
Unregistered Cards link, available only when a rack access card swiped at device for the
selection has not been registered.
Element
Description
List
Card ID#: The identification number
assigned to the card.
Timestamp: The date and time the rack
access card was swiped.
Register
Select to register the selected rack access cards.
Remove
Select to remove the selected unregistered rack
access cards from the list.
Remove All
Select to remove all unregistered rack access
cards from the list.
"Add Rack Access Card" display
Use this display to add a rack access card, and specify its authorization level.
Element
Description
Card ID #
Identify the number assigned to the card, in the
format shown.
User Name
Identify the user name assigned to the card
Description
Provide a description for the card, if desired.
Requires Authorization Card Swipe
Specify whether a swipe from an additional card
is required to authorize rack access.
"Edit Rack Access Card" display
Use this display to modify the settings, with the exception of the card ID #, for a rack access
card.
StruxureWare Data Center Expert 7.2.1
253
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
This demo code just converts first page to jpeg image. String inputFilePath = @"C:\input.pdf"; String outputFilePath = @"C:\output.jpg"; // Convert PDF to jpg.
change pdf into jpg; convert pdf images to jpg
C# Image Convert: How to Convert Tiff Image to Jpeg, Png, Bmp, &
RasterEdge.XDoc.PDF.dll. This demo code will convert first page to jpeg image. C:\input.tif"; String outputFilePath = @"C:\output.jpg"; // Convert tiff to jpg.
convert pdf to jpg for; bulk pdf to jpg
Element
Description
Card ID #
The number assigned to the rack access card
cannot be modified.
Note:  You can use the "Add Rack Access Card"
display to add another card and copy settings to
it.
User Name
Modify the user name assigned to the card.
Description
Modify the description.
Requires Authorization Card Swipe
Specify whether a swipe from an additional card
is required to authorize rack access.
"Copy Rack Access Card" display
Use this display to copy the weekly access schedule from the selected rack access card to
one or more cards.
Element
Description
Source Card
The Card ID # and user name of the card from
which the weekly access schedule will be copied.
Include Authorization Card Swipe Attribute
Check-mark to require a swipe from an additional
card to authorize rack access.
List
Check-mark one or more rack access cards
on which to copy the weekly access
schedule.
"Schedule Access" display
Use this display to define the specific periods of time, for each day of the week, during which
rack access will be enabled or disabled for the card selected, and the device group, NetBotz
Appliance, Rack Access Pod 170 device, or door selected, in the "Rack Access Settings"
display.
The table provides cells for 15-minute increments, and columns for every day of the week.
You can do all of the following to schedule when rack access is enabled:
• Click a column title to enable or disable all of that day's cells.
• Drag your mouse from one cell to another cell in a column, to enable or disable a set
of cells.
• Drag your mouse from a cell in one column to a cell in another column, to enable or
disable an identical set of cells for each of the selected days.
Enable or disable all cells ( Enable All or  Disable All button icons).
• Double-click or right-click a disabled cell to schedule access for the day selected
( New Schedule option).
• Double-click or right-click an enabled cell to modify scheduled access for the day
selected ( Edit Schedule option).
• Right-click an enabled cell to disable scheduled access for the day selected ( Remove
Schedule option).
StruxureWare Data Center Expert 7.2.1
254
C# Create PDF from images Library to convert Jpeg, png images to
Batch convert PDF documents from multiple image formats, including Jpg, Png, Bmp, Gif, Tiff, Bitmap, .NET Graphics, and REImage.
change from pdf to jpg; convert pdf picture to jpg
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Resize converted image files in VB.NET. Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in ASP.NET. Embed PDF to image converter in viewer.
best pdf to jpg converter online; convert pdf to jpg
Region Settings option
Use this option's configuration display to edit the regional settings at the selected NetBotz
Appliance or Appliances.
Element
Description
Locale
Select the locale that best identifies where a
selected appliance is physically located, to match
a selected NetBotz Appliance's measurements
(metric or US standard) and date/time formats to
the formats commonly used at that location.
Use 24-hour Time
Select to have a selected appliance use a 24-
hour clock.
Time Zone
Select the time zone in which a selected
appliance is located.
Serial Device Settings option
Use this option's configuration display to identify the  Port Label for each serial port at the
selected NetBotz Appliance, and the devices that connect to those ports.
You can select  Remove to delete a port's device reference when the device is disconnected
from the NetBotz Appliance.
SMS Settings option
Use this option's configuration display to configure the settings the selected NetBotz
Appliance can use for Short-Message Service (SMS) communication.
Basic tab
Element
Description
SIM PIN
For modems that use a SIM (subscriber
identification module), identify the PIN (personal
identification number) used to unlock that SIM.
Note:  For modems that do not have a SIM, this
field must be blank.
Confirm SIM PIN
Identify the SIM PIN, again.
Service Center (SMSC)
Identify the address of the Short Message
Service Center (SMSC) used by your SMS
service.
The SMSC is essentially an SMS server that
is used to send the messages. The address
for the SMSC is typically programmed into
StruxureWare Data Center Expert 7.2.1
255
VB.NET PDF - Convert PDF with VB.NET WPF PDF Viewer
Jpeg, VB.NET compress PDF, VB.NET print PDF, VB.NET merge PDF files, VB.NET view PDF online, VB.NET Convert PDF to image formats, such as PNG, JPG, BMP and
advanced pdf to jpg converter; bulk pdf to jpg converter online
VB.NET Create PDF from images Library to convert Jpeg, png images
Components to batch convert PDF documents in Visual Basic .NET class. Support create PDF from multiple image formats in VB.NET, including Jpg, Png, Bmp, Gif
convert pdf file into jpg; .pdf to jpg
the SIM and, therefore, you can typically
leave this field blank.
Note:  Entering a value in this field will override
automatic SMSC selection.
Destination
Identify the address used to send an SMS to an
e-mail destination.
When an SMS message needs to be sent to
an e-mail destination address, the NetBotz
Appliance puts the e-mail address at the
beginning of the message and sends it to
the Destination address. The SMSC
receives the message, pulls out the e-mail
address, and sends the remainder of the
message to that address.
Note:  The default value for this field is
0000000000, the value that works with AT&T
Wireless.
Interrupt PPP When an SMS Alert Occurs
Select this option if your modem supports both
SMS and Point-to-Point Protocol (PPP)
communications, to allow SMS communication
to override PPP communication when
necessary.
If PPP dial-out is active when the NetBotz
Appliance needs to send an SMS alert, PPP
will be interrupted while the SMS message
is sent.
Once the SMS message has been sent, the
PPP connection will be reestablished.
Advanced tab
Element
Description
Send Debug Messages to Syslog
Select to have debug messages forwarded to the
syslog host.
Use Default SMS Settings
Select to use the default SMS values for your
SMS-capable modem.
Note:  To use custom settings, disable this option
and use  Use Protocol Descriptor Unit (PDU),
Character Set, and  Initialization Commands
to specify those customs settings.
Use Protocol Descriptor Unit (PDU)
Select to use the PDU mode when
communicating with the modem to send an SMS
message.
Note:  PDU mode is more versatile than the
default SMS text settings mode, and some
modems do not support both modes.
Character Set
Identify the character set to be used when
communicating with the modem to send an SMS
message.
StruxureWare Data Center Expert 7.2.1
256
Initialization Commands
Identify the initialization string to be used for the
modem that will send SMS messages.
SNMP Settings option
Use this option's configuration display to configure the Simple Network Management
Protocol (SNMP) settings the selected NetBotz Appliance or Appliances can use to
communicate with an SNMP-based Network Management Server (NMS).
Note:   Enable SNMP Agent must be selected to configure the settings.
Version 1/Version 2c tab
Use this tab to define the settings an NMS can use for SNMPv1 or SNMPv2c communication
with a NetBotz Appliance.
Element
Description
Enable SNMP Agent
Select to enable the SNMP agent settings.
Read-only Community Name
Define the community name used for read-only
SNMP requests.
Confirm Name
Confirm a new or edited  Read-only Community
Name definition.
Read/Write Community Name
Define the community name used for read and
write SNMP requests.
Confirm Name
Confirm a new or changed  Read/Write
Community Name definition.
Port
Identify the number of the port used for SNMP
agent communication.
Version 3 tab
Use this tab to identify the settings that an NMS can use for SNMPv3 communication with
a NetBotz Appliance.
Element
Description
Users
Select the user accounts an NMS can use to
connect to the SNMPV3 Agent on a selected
NetBotz Appliance.
Authentication Protocol
Select  SHA-1 or  MD5 as the protocol used when
sending SNMPv3 informs to the target device.
Encryption Algorithm
Select whether encryption will be used with the
SNMPv3, and if used, which protocol:  None,
DES, or  AES-128.
StruxureWare Data Center Expert 7.2.1
257
User Settings option
Use this option's configuration display to manage the users at the selected NetBotz
Appliance or Appliances, as well as to select the severity of logon failures, and the alert
profile used for the alert notifications for those failures.
Users
 Users list identifies the users by  Name Username, and  Privilege Set., and  Add,
Edit, and  Delete buttons allow you to manage that list.
The "Add User" and "Edit User" displays have standard account  Name and logon values
( Username Password, and  Verify Password). They also have a  Privilege Set drop-
down menu used to select the access a user will have at the selected NetBotz Appliances.
Note:  You cannot delete the  Guest Account, and can only edit its  Privilege Set; you can
edit the  Name,  Username, and  Password values for the default administrator, but you
cannot delete it, or change its  Privilege Set.
Privilege
Description
None
Allows no access to any features.
Administrator
Allows access to all information and
configuration tasks at a selected appliance.
Sensor (No camera)
Allows access to the  Navigation pane,  Sensor
Data pane,  Map View (if enabled), and selected
portions of the  NetBotz Advanced View
information and action views, as well as the
ability to view the  Graphs View and  About view.
This  Privilege Set does not allow access to
the  Cameras View,  Alerts View, or
Configuration view.
Sensor
In addition to  Sensor ( No Camera) access,
allows access to the  Cameras View.
This Privilege Set does not permit access to
the  Alerts View or  Configuration view.
Application
Allows access to the  Navigation pane,  Sensor
Data pane,  Map View (if enabled), and selected
portions of the  NetBotz Advanced View
information and action views. Also allows viewing
the  Camera View,  Graphs View,  Alerts
View, and  About view.
This  Privilege Set does not permit access
to the  Configuration view, or the ability to
resolve alert conditions for thresholds
configured with the  Return-To-Normal
Requires User Input setting selected for
their  Advanced Settings.
Application (with Alert Update)
In addition to  Application access, allows
the ability to resolve alert conditions for
thresholds configured with the  Return-To-
StruxureWare Data Center Expert 7.2.1
258
Normal Requires User Input setting
selected for their  Advanced Settings.
This  Privilege Set does not permit access to
the  Configuration view.
Logon alerting
Provides two drop-down menus, one which selects the alert profile you want a selected
NetBotz Appliance (greyed out when multiple appliances are selected) to use for alert
notifications for logon failures, and one which selects the severity you want assigned to
logon failures at the selected appliance or appliances:  Informational,  Warning,  Error,
Critical, and  Failure.
Note:   Default, for  Logon Failure Alert Profile, and  Failure, for  Logon Failure Alert
Severity, are the default settings.
Web Server Settings option
Use this option's configuration display to select the  HTTP protocol,  HTTPS protocol, or
both, and define the  Port number for each, that the selected NetBotz Appliance or
Appliances can use for web-based communication.
StruxureWare Data Center Expert 7.2.1
259
APC SNMP Device Configuration (Device menu)
Use this option to select one or more of the monitored APC SNMP devices, including all
that are listed, and configure those devices to use settings shared with a selected APC
SNMP device, or settings saved as a template.
Note:  You cannot use this option to configure settings for non-APC SNMP devices, NetBotz
Appliances and their monitored devices, and some older APC SNMP devices.
The following "APC SNMP Device Configuration" wizard displays, and  Configuration
Status view, are used by the APC SNMP Device Configuration feature:
"Select a Configuration Action" display
Use this "APC SNMP Device Configuration" wizard display to select the action you want to
perform.
Configure Devices action
Allows you to use a monitored APC SNMP device's settings to configure and apply those
same settings at other monitored APC SNMP devices.
Note:  You can use this action to configure the settings for a single APC SNMP device, by
selecting it as both the source and destination device, and editing the settings you want to
change at that device.
1. Select  Configure Devices and click  Next.
2. Use the "Select Configuration Source" display to select the APC SNMP device you
want to use as the configuration source, and click  Next.
3. Use the "Select Destination Devices" display to select the APC SNMP devices you
want to configure using settings from the selected source APC SNMP device, and
click  Next.
4. Use the "Configure Device Settings" display to select, and edit, as needed, the source
APC SNMP device settings to be used to configure the same settings at the APC
SNMP devices selected in the "Select Destination Devices" display, and click
Finish to initiate the configuration activity.
5. Review the process of the configuration activity in the  Configuration Status view.
Create a Template action
Allows you to use a monitored APC SNMP device's settings to create a template that can
be used to configure monitored APC SNMP devices.
1. Select  Create a Template, and click  Next.
2. Use the "Select Configuration Source" display to select the APC SNMP device you
want to use as the template source, and click  Next.
StruxureWare Data Center Expert 7.2.1
260
Documents you may be interested