asp.net mvc pdf generator : C# pdf to image SDK Library API wpf .net html sharepoint Katalog_D21.1_2006_eng12-part2057

SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/107
Siemens D 21.1 · 2006
2
Integration (continued)
Connection example of Single Motor Modules in booksize format 45 A to 200 A
X201
X200
+Temp
X21
EP M1
EP +24 V
BR+
BR-
X202
4
3
2
1
M
3 ~
E
U2
V2
X11
M
+
DCN
DCP
M
+
DCN
DCP
Single Motor Module
5)
1)
+
X12
-
2
1
1
2
W2
READY
L
E
D
s
DC LINK
2)
3)
M
-Temp
4)
G_D212_EN_00033f
DC link busbars
24 V DC busbars
DRIVE-CLiQ socket    2 
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
0
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
1
Fan
Required for Safety.
Temperature sensor terminal for motors without DRIVE-CLiQ interface.
The braking signal has an integrated overvoltage protection.
An external circuit of the holding brake is not necessary.
Contacting via shield plate.
Fan insert for 132 A and 200 A Single Motor Modules.
The fan insert is supplied with the Single Motor Module.
1)
2)
3)
4)
5)
Change pdf to jpg file - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf into jpg; best pdf to jpg converter online
Change pdf to jpg file - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
changing pdf file to jpg; convert pdf picture to jpg
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/108
Siemens D 21.1 · 2006
2
Technical data
General technical data
1)
Note correlation between max. output frequency, pulse frequency and 
current derating, see System Description.
Electrical data
DC link voltage
(up to 2000m (6563 ft) above sea level)
510 V to 720 V DC
(line voltage380V to 480 V 3 AC)
max. output voltage, line-to-line
(fundamental-wave RMS value)
0.67 x DC link voltage
Output frequency
•Control type Servo
0Hz to 650Hz 
1)
•Control type Vector
0Hz to 300Hz 
1)
•Control type V/f
0Hz to 300Hz 
1)
Electronics power supply
24V DC –15%/+20%
Radio interference suppression
•Standard
No radio interference suppression
•in combination with Line Module incl. line filter and line reactor
ClassA1 to EN55011 and
Category C2 to EN61800-3
Ambient conditions
Type of cooling
Forced air cooling through built-in fan
Permissible ambient and coolant temperature (air) during operation for 
line-side components, Line Modules and Motor Modules
0 °C to + 40 °C (32 °F to + 104 °F) without derating, 
> 40 °C to + 55 °C (> 104 °F to + 131 °F) see derating characteristics
Site altitude
Up to 1000 m (1328 ft) above sea level without derating,
> 1000 m (1328 ft) to 4000 m (13126 ft) above sea level see derating 
characteristics
Certificates
Conformity
CE (low-voltage and EMC Directives)
Approvals
cULus (File No.: E192450)
Certification
Safety Integrity Level 2 (SIL 2) to IEC 61508,
control category 3 to EN 954-1 for Safety Integrated – safe standstill (STO 
= Safe Torque Off) and safe brake control (SBC = Safe Brake Control)
Online Convert Jpeg to PDF file. Best free online export Jpg image
You can drag and drop your JPG file in the box, and then start immediately to sort the files, try out some settings and then create the PDF files with the
convert multiple pdf to jpg online; convert pdf file to jpg
Online Convert PDF to Jpeg images. Best free online PDF JPEG
Online PDF to JPEG Converter. Download Free Trial. Convert a PDF File to JPG. Drag and drop your PDF in the box above and we'll convert the files for you.
convert pdf to jpg c#; c# pdf to jpg
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/109
Siemens D 21.1 · 2006
2
Technical data (continued)
1)
Rated DC link current for dimensioning an external DC connection.
For DC link current calculation for dimensioning the Line Module, see 
System Description.
2)
Power loss of Motor Module at rated output without losses of 24 V DC 
electronics power supply.
DC link voltage 
510 V to 720 V DC
Single Motor Modules in booksize format
Internal air cooling
6SL3120-
1TE13-0AA0
6SL3120-
1TE15-0AA0
6SL3120-
1TE21-0AA1
6SL3120-
1TE21-8AA1
6SL3120-
1TE23-0AA1
Internal air cooling with 
varnished modules
6SL3120-
1TE13-0AB0
6SL3120-
1TE15-0AB0
6SL3120-
1TE21-0AB0
6SL3120-
1TE21-8AB0
6SL3120-
1TE23-0AB0
External air cooling
6SL3121-
1TE13-0AA0
6SL3121-
1TE15-0AA0
6SL3121-
1TE21-0AA0
6SL3121-
1TE21-8AA0
6SL3121-
1TE23-0AA0
Rated
output current I
rated
A
3
5
9
18
30
Base load currentI
H
A
2.6
4.3
7.7
15.3
25.5
Output current
for S6 duty (40%) I
S6
A
3.5
6
10
24
40
Max. output current I
max
A
6
10
18
36
56
Rated power
for 600 V DC link voltage
kW (HP)
1.6 (1.5)
2.7 (3)
4.8 (5)
9.7 (10)
16.0 (20)
Power based on I
H
for 600 V DC link voltage
kW (HP)
1.4 (1)
2.3 (2.5)
4.1 (5)
8.2 (10)
13.7 (18)
Rated pulse frequency
kHz
4
4
4
4
4
DC link current I
d
1)
A
3.6
6
11
22
36
DC link busbar current 
capacity
A
100
100
100
100
100
DC link capacitance
µF
110
110
110
220
710
Max. current
requirement at 24 V DC
A
0.85
0.85
0.85
0.85
0.9
24 V DC busbar current 
capacity
A
20
20
20
20
20
If, due to a number of Line and Motor Modules being mounted side-by-side, the current carrying capacity 
exceeds 20 A, an additional 24 V DC connection using a 24-V terminal adapter is required (max. cross 
section 6mm
2
, max. fuse protection 20 A).
Efficiency 
η
0.97
0.97
0.97
0.97
0.97
Power loss with internal 
air cooling in control cabinet
kW
0.035
0.055
0.080
0.165
0.290
Power loss 
2)
with external 
air cooling int./ext.
kW
0.015/0.015
0.023/0.03
0.035/0.045
0.075/0.09
0.08/0.21
Cooling air requirement
m
3
/s (ft
3
/s) 0.008 (0.283)
0.008 (0.283)
0.008 (0.283)
0.008 (0.283)
0.016 (0.565)
Sound pressure level
dB(A)
<60
<60
<60
<60
<60
Motor connection
U2, V2, W2
Plug-in connector 
(X1), max. 30 A
(not included in 
scope of supply, 
see Accessories)
Plug-in connector 
(X1), max. 30 A
(not included in 
scope of supply, 
see Accessories)
Plug-in connector 
(X1), max. 30 A
(not included in 
scope of supply, 
see Accessories)
Plug-in connector 
(X1), max. 30 A
(not included in 
scope of supply, 
see Accessories)
Plug-in connector 
(X1), max. 30 A
(not included in 
scope of supply, 
see Accessories)
Shield connection
integrated in 
connector (X1)
integrated in 
connector (X1)
integrated in 
connector (X1)
integrated in 
connector (X1)
integrated in 
connector (X1)
PE connection
On housing with M5 
screw
On housing with M5 
screw
On housing with M5 
screw
On housing with M5 
screw
On housing with M5 
screw
Motor brake connection
Integrated into the 
plug-in motor 
connector (X1),
24 V DC, 2 A
Integrated into the 
plug-in motor 
connector (X1),
24 V DC, 2 A
Integrated into the 
plug-in motor 
connector (X1),
24 V DC, 2 A
Integrated into the 
plug-in motor 
connector (X1),
24 V DC, 2 A
Integrated into the 
plug-in motor 
connector (X1),
24 V DC, 2 A
Max. motor cable length
m (ft)
50 (164) 
shielded
75 (246) 
unshielded
50 (164) 
shielded
75 (246) 
unshielded
50 (164) 
shielded
75 (246) 
unshielded
70 (230) 
shielded
100 (328) 
unshielded
100 (328) 
shielded
150 (492) 
unshielded
Degree of protection
IP20
IP20
IP20
IP20
IP20
Width
mm (inch) ) 50 (1.97)
50 (1.97)
50 (1.97)
50 (1.97)
100 (3.94)
Height
mm (inch) ) 380 (14.98)
380 (14.98)
380 (14.98)
380 (14.98)
380 (14.98)
Depth with internal 
air cooling
mm (inch) ) 270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
Depth with external 
air cooling
on/behind mounting surface
mm (inch) ) 226/66.5 (8.9/2.6)
226/66.5 (8.9/2.6)
226/66.5 (8.9/2.6)
226/66.5 (8.9/2.6)
226/66.5 (8.9/2.6)
Approx. weight with internal 
air cooling
kg (lb)
5.1 (11)
5.1 (11)
5.0 (11)
5.0 (11)
6.9 (15)
Approx. weight with external 
air cooling
kg (lb)
5.7 (13)
5.7 (13)
5.7 (13)
5.7 (13)
8.5 (19)
C# Image Convert: How to Convert Adobe PDF to Jpeg, Png, Bmp, &
C# sample code for PDF to jpg image conversion. This demo code convert PDF file all pages to jpg images. // Define input and output files path.
convert pdf file into jpg; bulk pdf to jpg
C# Image Convert: How to Convert Dicom Image File to Raster Images
RasterEdge.XDoc.Office.Inner.Office03.dll. RasterEdge.XDoc.PDF.dll. RasterEdge.XDoc. PowerPoint.dll. This demo code convert dicom file all pages to jpg images.
convert pdf to jpg batch; convert pdf to jpg 300 dpi
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/110
Siemens D 21.1 · 2006
2
Technical data (continued)
1)
Rated DC link current for dimensioning an external DC connection.
For DC link current calculation for dimensioning the Line Module, see 
System Description.
2)
Power loss of Motor Module at rated output without losses of 24 V DC 
electronics power supply.
3)
The fan is supplied with the Motor Module and must be installed befor 
the Motor Module is commissioned.
DC link voltage 
510 V to 720 V DC
Single Motor Modules in booksize format
Internal air cooling
6SL3120-
1TE24-5AA1
6SL3120-
1TE26-0AA1
6SL3120-
1TE28-5AA1
6SL3120-
1TE31-3AA0
6SL3120-
1TE32-0AA0
Internal air cooling with 
varnished modules
6SL3120-
1TE24-5AB0
6SL3120-
1TE26-0AB0
6SL3120-
1TE28-5AB0
6SL3120-
1TE31-3AB0
6SL3120-
1TE32-0AB0
External air cooling
6SL3121-
1TE24-5AA0
6SL3121-
1TE26-0AA0
6SL3121-
1TE28-5AA0
6SL3121-
1TE31-3AA0
6SL3121-
1TE32-0AA0
Rated
output current I
rated
A
45
60
85
132
200
Base load currentI
H
A
38
52
68
105
141
Output current
for S6 duty (40%) I
S6
A
60
80
110
150
230
Max. output current I
max
A
85
113
141
210
282
Rated pulse frequency
kHz
4
4
4
4
4
Rated power for 
600 V DC link voltage
kW (HP)
24 (30)
32 (40)
46 (60)
71 (100)
107 (150)
Power based on I
H
600 V DC link voltage
kW (HP)
21 (25)
28 (40)
37 (50)
57 (75)
76 (100)
DC link current I
d
1)
A
54
72
102
158
200
DC link busbar current 
capacity
A
100
100
200
200
200
DC link capacitance
µF
1175
1410
1880
2820
3995
Max. current
requirement at 24 V DC
A
1.2
1.2
1.5
1.5
1.5
24 V DC busbar current 
capacity
A
20
20
20
20
20
If, due to a number of Line and Motor Modules being mounted side-by-side, the current carrying capacity 
exceeds 20 A, an additional 24 V DC connection using a 24 V terminal adapter is required (max. cross 
section 6mm
2
, max. fuse protection 20 A).
Efficiency 
η
0.97
0.97
0.97
0.97
0.97
Power loss with internal air 
cooling in control cabinet
kW
0.43
0.59
0.75
1.25
2.05
Power loss 
2)
with external 
air cooling int./ext.
kW
0.11/0.32
0.135/0.455
0.16/0.59
0.25/1.0
0.4/1.65
Cooling air requirement
m
3
/s (ft
3
/s) 0.031 (1.095)
0.031 (1.095) 
0.044 (1.554)
0.144 (5.085)
0.144 (5.085)
Sound pressure level
dB(A)
<65
<65
<60
<73
<73
Motor connection
U2, V2, W2
M6 screw studs,
2.5 mm
2
to 50 mm
2
(X1)
M6 screw studs,
2.5 mm
2
to 50 mm
2
(X1)
M8 screw studs,
2.5 mm
2
to 95 mm
2
,
2×35 mm
2
(X1)
M8 screw studs,
2.5 mm
2
to 120 
mm
2
, 2×50 mm
2
(X1)
M8 screw studs,
2.5 mm
2
to 120 
mm
2
, 2×50 mm
2
(X1)
Shield connection
see Accessories
see Accessories
see Accessories
see Accessories
see Accessories
PE connection
On housing with M6 
screw
On housing with M6 
screw
On housing with M6 
screw
On housing with M8 
screw
On housing with M8 
screw
Motor brake connection
Plug-in connector 
(X11), 24 V DC, 2 A
Plug-in connector 
(X11), 24 V DC, 2 A
Plug-in connector 
(X11), 24 V DC, 2 A
Plug-in connector 
(X11), 24 V DC, 2 A
Plug-in connector 
(X11), 24 V DC, 2 A
Max. motor cable length
m (ft)
100 (328) 
shielded
150 (492) 
unshielded
100 (328) 
shielded
150 (492) 
unshielded
1100 (328) 
shielded
150 (492) 
unshielded
100 (328) 
shielded
150 (492) 
unshielded
100 (328) 
shielded
150 (492) 
unshielded
Degree of protection
IP20
IP20
IP20
IP20
IP20
Width
mm (inch) ) 150 (5.91)
150 (5.91)
200 (7.87)
300 (11.81)
300 (11.81)
Height
mm (inch) ) 380 (14.96)
380 (14.96)
380 (14.96)
380, (14.96)
with fan 
3)
: 629 
(24.8)
380, (14.96)
with fan 
3)
: 629 
(24.8)
Depth with internal 
air cooling
mm (inch) ) 270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
270 (10.63)
Depth with external 
air cooling
on/behind mounting surface
mm (inch) ) 226/71 (8.9/2.8)
226/71 (8.9/2.8)
226/92 (8.9/3.6)
226/82 (8.9/3.2)
226/82 (8.9/3.2)
Approx. weight with internal 
air cooling
kg (lb)
9 (20)
9 (20)
15 (33)
21 (46)
21 (46)
Approx. weight with external 
air cooling
kg (lb)
13.2 (29)
13.4 (30)
17.2 (38)
27.2 (60)
30 (66)
C# TIFF: How to Use C#.NET Code to Compress TIFF Image File
C:\demo3.jpg" }; // Construct List<REImage> object. List<Bitmap> images = new List<Bitmap>(); / Step1: Load image to REImage object. foreach (string file in
convert pdf document to jpg; convert pdf pages to jpg online
C# Create PDF from images Library to convert Jpeg, png images to
Add(new Bitmap(Program.RootPath + "\\" 1.jpg")); images.Add 1.png")); / Build a PDF document with PDFDocument(images.ToArray()); / Save document to a file.
batch pdf to jpg; convert pdf pictures to jpg
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/111
Siemens D 21.1 · 2006
2
Selection and ordering data
Accessories
1)
Nominal HP based on Asynchronous motors (induction motors). 
Match the motor nameplate current for specific sizing.
Rated output current
Rated power
Single Motor Module in booksize format
Internal air cooling
Internal air cooling with 
varnished modules
External air cooling
A
kW (HP) 
1)
Order No.
Order No.
Order No.
DC link voltage 510 V to 720 V DC
3
1.6 (1.5)
6SL3120-1TE13-0AA0
6SL3120-1TE13-0AB0
6SL3121-1TE13-0AA0
5
2.7 (3)
6SL3120-1TE15-0AA0
6SL3120-1TE15-0AB0
6SL3121-1TE15-0AA0
9
4.8 (5)
6SL3120-1TE21-0AA1
6SL3120-1TE21-0AB0
6SL3121-1TE21-0AA0
18
9.7 (10)
6SL3120-1TE21-8AA1
6SL3120-1TE21-8AB0
6SL3121-1TE21-8AA0
30
16 (20)
6SL3120-1TE23-0AA1
6SL3120-1TE23-0AB0
6SL3121-1TE23-0AA0
45
24 (30)
6SL3120-1TE24-5AA1
6SL3120-1TE24-5AB0
6SL3121-1TE24-5AA0
60
32 (40)
6SL3120-1TE26-0AA1
6SL3120-1TE26-0AB0
6SL3121-1TE26-0AA0
85
46 (60)
6SL3120-1TE28-5AA1
6SL3120-1TE28-5AB0
6SL3121-1TE28-5AA0
132
71 (100)
6SL3120-1TE31-3AA0
6SL3120-1TE31-3AB0
6SL3121-1TE31-3AA0
200
107 (150)
6SL3120-1TE32-0AA0
6SL3120-1TE32-0AB0
6SL3121-1TE32-0AA0
Description
Order No.
Power connector (X1)
At Motor Module end, with screw-type terminals 1.5 mm
2
to 10mm
2
,
for Motor Modules with a rated output current of 3 to 30A
6SL3162-2MA00-0AA0
Shield connection kit
for Line/Motor Modules in booksize format
•150 mm (5.91 in) wide for internal air cooling
6SL3162-1AF00-0AA1
•150 mm (5.91 in) wide for external air cooling
6SL3162-1AF00-0BA0
•200 mm (7.87 in) wide for internal air cooling
6SL3162-1AH01-0AA0
•200 mm (7.87 in) wide for external air cooling
6SL3162-1AH01-0BA0
•300 mm (11.81 in) wide
6SL3162-1AH00-0AA0
DC link supply adapter
for direct infeed of DC link voltage
•Screw-type terminals 0.5 mm
2
to 10mm
2
for Line Modules and Motor Modules in booksize format with a width of 50 mm (1.97 in) or 100 mm (3.84 in)
6SL3162-2BD00-0AA0
•Screw-type terminals 35 mm
2
to 95 mm
2
for Line Modules and Motor Modules in booksize format with a width of 150 mm (5.91 in), 200 mm (7.87 in) 
and 300 mm (11.81 in)
6SL3162-2BM00-0AA0
DC link adapters (2x)
for multi-tier configuration
Screw-type terminals 35 mm
2
to 95 mm
2
for all Line Modules/Motor Modules in booksize format
6SL3162-2BM01-0AA0
24 V terminal adapter
for all Line Modules/Motor Modules in booksize format
6SL3162-2AA00-0AA0
24 V jumper
for connection of the 24 V busbars (for booksize format)
6SL3162-2AA01-0AA0
Warning signs in foreign languages
This set of foreign language warning signs can be placed on top of the standard German or English signs.
One sign in each of the following languages is provided in each set:
Chinese Simplified, Danish, Dutch, Finnish, French, Greek, Italian, Japanese, Korean, Portuguese, Spanish and 
Swedish.
6SL3166-3AB00-0AA0
Plug-in motor brake connector for booksize format Motor Modules with a rated output current of 45 A to 200 A
Wago
http://www.wago.com
Item No.: 
231-102/037-000
(Wago)
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
Convert PDF to Jpg, Png, Bmp, Gif, Tiff and Bitmap in GetPage(0) ' Convert the first PDF page to a BMP file. Or directly change PDF to Gif image file in VB.NET
best program to convert pdf to jpg; best way to convert pdf to jpg
C# WPF PDF Viewer SDK to convert and export PDF document to other
Files; Split PDF Document; Remove Password from PDF; Change PDF Permission Settings. file formats with high quality, support converting PDF to PNG, JPG, BMP and
.net convert pdf to jpg; convert pdf file to jpg on
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/112
Siemens D 21.1 · 2006
2
Characteristics
Overload capability
Load cycle with previous load
Load cycle without previous load
S6 load cycle with previous load with a load cycle period of 600 s
S6 load cycle with previous load with a load cycle period of 60 s
Load cycle with 60 s overload with a load cycle period of 300 s
Load cycle with 30 s overload with a load cycle period of 300 s
max
10 s
t
rated
0.25 s
G
_
D
2
1
1
_
E
N
_
0
0
0
8
2
10 s
max
t
2.65 s
rated
G
_
D
2
1
1
_
E
N
_
0
0
0
8
3
4 min
max
S6
10 min
t
0.7 x 
rated
rated
G
_
D
2
1
1
_
E
N
_
0
0
0
8
4
10 s
max
60 s
t
0.7 x 
rated
rated
G
_
D
2
1
1
_
E
N
_
0
0
0
8
5
60 s
300 s
t
H
H
1.5 x
G_D211_EN_00001
Base load current
H
rated
G
_
D
2
1
1
_
E
N
_
0
0
0
0
1
b
30 s
300 s
t
H
H
1.76 x
Base load current
rated
H
G
_
D
2
1
1
_
E
N
_
0
0
0
0
2
b
SINAMICS S120
Motor Modules
Single Motor Modules in booksize format
2/113
Siemens D 21.1 · 2006
2
Characteristics (continued)
Derating characteristics
Output current dependent on pulse frequency
Output current dependent on ambient temperature
Output current dependent on installation altitude
Voltage derating dependent on installation altitude
P
e
r
m
i
s
s
i
b
l
e
o
u
t
p
u
t
c
u
r
r
e
n
t
Pulse frequency
G
_
D
2
1
2
_
E
N
_
0
0
0
0
2
a
100
90
80
70
60
50
0
4
8
12
16
20
40
30
20
10
2
6
10
14
%
kHz
P
e
r
m
i
s
s
i
b
l
e
o
u
t
p
u
t
c
u
r
r
e
n
t
Ambient temperature
G
_
D
2
1
1
_
E
N
_
0
0
0
8
9
(86)
(95)
(104)
(113)
(122)
(131)
(°F)
100
90
80
70
60
30
35
40
45
50
55
%
°C
P
e
r
m
i
s
s
i
b
l
e
o
u
t
p
u
t
c
u
r
r
e
n
t
Installation altitude above sea level
%
m
G
_
D
2
1
1
_
E
N
_
0
0
0
9
0
(ft)
(3282)
(6563)
(9845)
(13126)
(16408)
100
95
90
85
80
75
0
1000
2000
3000
4000
5000
70
65
60
P
e
r
m
i
s
s
i
b
l
e
i
n
p
u
t
v
o
l
t
a
g
e
i
n
%
o
f
r
a
t
e
d
v
o
l
t
a
g
e
G
_
D
2
1
1
_
E
N
_
0
0
0
0
6
(3282) 
(6563) 
(9845)
(ft)
(13126)
100
90
80
70
1.0
0.9
0.7
0.8
Installation altitude above sea level
D
e
r
a
t
i
n
g
f
a
c
t
o
r
k
U
1000 
2000 
m
0
3000
4000
SINAMICS S120
Motor Modules
Single Motor Modules in chassis format
2/114
Siemens D 21.1 · 2006
2
Design
The Single Motor Modules in chassis format feature the following 
interfaces as standard:
• 1 DC link connection
• 1 electronics power supply connection
• 3 DRIVE-CLiQ sockets
• 1 motor connection
• 1 safe standstill input (enable pulses)
• 1 temperature sensor input (KTY84-130 or PTC)
• 1 PE (protective earth) connection
The status of the Motor Modules is indicated via two multi-color 
LEDs.
The scope of supply of the Motor Modules includes:
• Types FX and GX: 
-0.60 m (1.97 ft) DRIVE-CLiQ cable for connection to the 
adjacent Motor Module
• Types HX and JX: 
-0.35 m (1.15 ft) DRIVE-CLiQ cable for connection to the 
CU320 or SIMOTION D Control Unit
-2.10 m (6.89 ft) DRIVE-CLiQ cable for connection to the 
adjacent Motor Module
Selection and ordering data
Warning signs in foreign languages
Warning signs in other languages can be placed on top of the 
standard warning signs in German or English.
The following signs are supplied with chassis format units:
Chinese, Danish, Finnish, French, Greek, Italian, Japanese, 
Korean, Dutch, Polish, Portuguese, Russian, Swedish, Spanish, 
Czech and Turkish.
1)
Nominal HP based on Asynchronous motors (induction motors). 
Match the motor nameplate current for specific sizing.
Rated 
output current
Rated 
power
Single Motor Module 
in chassis format
A
kW (HP) 
1)
Order No.
DC link voltage 510 V to 720 V DC
210
110 (150)
6SL3320-1TE32-1AA0
260
132 (200)
6SL3320-1TE32-6AA0
310
160 (250)
6SL3320-1TE33-1AA0
380
200 (300)
6SL3320-1TE33-8AA0
490
250 (400)
6SL3320-1TE35-0AA0
605
315 (500)
6SL3320-1TE36-1AA0
745
400 (600)
6SL3320-1TE37-5AA0
840
450 (700)
6SL3320-1TE38-4AA0
985
560 (800)
6SL3320-1TE41-0AA0
1260
710 (1000)
6SL3320-1TE41-2AA0
1405
800 (1150)
6SL3320-1TE41-4AA0
DC link voltage 890 V to 1035 V DC
85
75
6SL3320-1TH28-5AA0
100
90
6SL3320-1TH31-0AA0
120
110
6SL3320-1TH31-2AA0
150
132
6SL3320-1TH31-5AA0
175
160
6SL3320-1TH31-8AA0
215
200
6SL3320-1TH32-2AA0
260
250
6SL3320-1TH32-6AA0
330
315
6SL3320-1TH33-3AA0
410
400
6SL3320-1TH34-1AA0
465
450
6SL3320-1TH34-7AA0
575
560
6SL3320-1TH35-8AA0
735
710
6SL3320-1TH37-4AA0
810
800
6SL3320-1TH38-1AA0
910
900
6SL3320-1TH38-8AA0
1025
1000
6SL3320-1TH41-0AA0
1270
1200
6SL3320-1TH41-3AA0
SINAMICS S120
Motor Modules
Single Motor Modules in chassis format
2/115
Siemens D 21.1 · 2006
2
Integration
The Single Motor Module communicates with the CU320 or 
SIMOTION D Control Unit via DRIVE-CLiQ.
Connection example of Single Motor Module in chassis format
X402
1
X401
2
0
X400
P24_1
X9
U1
V1
W1
Single Motor
Module
DCP
DCN
2
1
4
3
6
5
M_1
VL_1
VL_2
HS1
HS2
DCPA
DCNA
DCPS
DCNS
H200
L
E
D
s
H201
=
=
L1
L2
-F10
-F11
-F10
-F11
M
3
E
+Temp
-Temp
EP M1
M
EP +24 V 
4
X41
4
3
2
1
G
_
D
2
1
1
_
E
N
_
0
0
0
1
1
b
DRIVE-CLiQ socket 
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
380 to 480 V AC / 
660 to 690 V AC
380 to 480 V AC / 
660 to 690 V AC
Fan supply terminal for frame
sizes FX and GX
directly on fuse holder 
Fan supply terminal for frame
sizes HX and JX
DC link busbars
Dv/dt filter terminal
Braking Module Terminal
Fan
Fan
SINAMICS S120
Motor Modules
Single Motor Modules in chassis format
2/116
Siemens D 21.1 · 2006
2
Technical data
General technical data
1)
Note correlation between max. output frequency, pulse frequency and 
current derating, see System Description.
Electrical data
DC link voltage
(up to 2000m (6563 ft) above sea level)
510V to 720V DC (line voltage 380V to 480V 3AC) or
890V to 1035V DC (line voltage 660V to 690V 3AC)
Max output voltage, line-to-line
(fundamental-ware RMS value)
0.72 x DC link voltage
Output frequency
•Control type Servo
0Hz to 650Hz 
1)
•Control type Vector
0Hz to 300Hz 
1)
•Control type V/f
0Hz to 300Hz 
1)
Electronics power supply
24V DC –15%/+20%
Radio interference suppression
•Standard
No radio interference suppression
•in combination with Line Module and line reactor
Category C3 to EN61800-3
•in combination with Line Module incl. line filter and line reactor
ClassA1 to EN55011 and
Category C2 to EN61800-3
Ambient conditions
Type of cooling
Internal/external air cooling, power units with increased air cooling by 
means of built-in fan
Permissible ambient and coolant temperature (air) during operation for 
line-side components, Line Modules and Motor Modules
0 °C to + 40 °C (32 °F to + 104 °F) without derating, 
> 40 °C to + 55 °C (> 104 °F to + 131 °F) see derating characteristics
Site altitude
Up to 2000 m (6563 ft) above sea level without derating,
> 2000 m (6563 ft) to 4000 m (13126 ft) above sea level see derating 
characteristics
Certificates
Conformity
CE (low-voltage and EMC Directives)
Approvals
cULus (File No.: E192450)
Certification
Safety Integrity Level 2 (SIL 2) to IEC 61508,
control category 3 to EN 954-1 for Safety Integrated – safe standstill 
(STO = Safe Torque Off)
Documents you may be interested