asp.net mvc pdf editor : Change pdf to bitmap software Library cloud windows asp.net winforms class Katalog_D21.1_2006_eng7-part2104

SINAMICS S120
Power Modules and line-side components
Power Modules in chassis format
Line reactors
2/57
Siemens D 21.1 · 2006
2
Overview
Line reactors limit the low-frequency harmonic effects and re-
duce the load on the rectifiers of the Power Modules. The higher 
the rated output of the Power Modules, the lower the required in-
ductance of the line reactor. A line reactor is not required where 
the effective supply impedance equals u
k
>3%. For further in-
formation see "System Description".
Technical data
Selection and ordering data
Line voltage 
Line reactor
380 V to 480 V 3 AC
6SL3000-0CE32-3AA0
6SL3000-0CE32-8AA0
6SL3000-0CE33-3AA0
6SL3000-0CE35-1AA0
Rated current
A
224
278
331
508
Power loss at 50Hz/60Hz z kW
0.24/0.27
0.21/0.25
0.23/0.27
0.31/0.37
Line supply connection
1U1, 1V1, 1W1
Flat connector 
for M10 cable lug
Flat connector 
for M10 cable lug
Flat connector 
for M10 cable lug
Flat connector 
for M12 cable lug
Load connection
1U2, 1V2, 1W2
Flat connector 
for M10 cable lug
Flat connector 
for M10 cable lug
Flat connector 
for M10 cable lug
Flat connector 
for M12 cable lug
PE connection
M6 screw
M6 screw
M6 screw
M6 screw
Degree of protection
IP00
IP00
IP00
IP00
Width
mm (inch) ) 270 (10.63)
270 (10.63)
270 (10.63)
300 (11.81)
Height
mm (inch) ) 248 (9.76)
248 (9.76)
248 (9.76)
269 (10.59)
Depth
mm (inch) ) 200 (7.87)
200 (7.87)
200 (7.87)
212.5 (8.37)
Weight, approx.
kg (lb)
24.4 (54)
26 (57)
27.8 (61)
38 (84)
Suitable for 
Power Module
Type
6SL3310-1TE32-1...
6SL3310-1TE32-6...
6SL3310-1TE33-1...
6SL3310-1TE33-8...
6SL3310-1TE35-0...
Rated output current
Rated power
Suitable for Power Module
Line reactor
A
kW (HP)
Type
Order No.
Line voltage 380 V to 480 V 3 AC
210
110 (150)
6SL3310-1TE32-1AA0
6SL3000-0CE32-3AA0
260
132 (200)
6SL3310-1TE32-6AA0
6SL3000-0CE32-8AA0
310
160 (250)
6SL3310-1TE33-1AA0
6SL3000-0CE33-3AA0
380
200 (300)
6SL3310-1TE33-8AA0
6SL3000-0CE35-1AA0
490
250 (400)
6SL3310-1TE35-0AA0
6SL3000-0CE35-1AA0
Error processing SSI file
SINAMICS S120
Power Modules and line-side components
Power Modules in chassis format
Line filters
2/58
Siemens D 21.1 · 2006
2
Overview
In plants with strict EMC requirements, line filters work together 
with line reactors to restrict the conducted interference emanat-
ing from the Power Modules to the limit values of Category C2 as 
defined in EN61800-3. Line filters are suited only for direct 
connection to TN (grounded) systems.
Integration
Technical data
Selection and ordering data
Power Module
~
~
M
3 ~
Line reactor
G
_
D
2
1
1
_
E
N
_
0
0
0
6
3
Line
Line filter
Line voltage 
Line filter
380 V to 480 V 3 AC
6SL3000-0BE32-5AA0
6SL3000-0BE34-4AA0
6SL3000-0BE36-0AA0
Rated current
A
250
440
600
Power loss
kW
0.05
0.05
0.06
Line supply connection
1U1, 1V1, 1W1
Flat connector for M10 cable lug
Flat connector for M10 cable lug
Flat connector for M10 cable lug
Load connection
1U2, 1V2, 1W2
Flat connector for M10 cable lug
Flat connector for M10 cable lug
Flat connector for M10 cable lug
Degree of protection
IP00
IP00
IP00
Width
mm (inch) ) 360 (14.17)
360 (14.17)
400 (15.75)
Height
mm (inch) ) 240 (9.45)
240 (9.45)
265 (10.43)
Depth
mm (inch) ) 116 (4.57)
116 (4.57)
140 (5.51)
Weight, approx.
kg (lb)
12.5 (28)
12.5 (28)
19 (42)
Suitable for 
Power Module
Type
6SL3310-1TE32-1...
6SL3310-1TE32-6...
6SL3310-1TE33-1...
6SL3310-1TE33-8...
6SL3310-1TE35-0...
Rated output current
Rated power
Suitable for Power Module
Line filter
A
kW (HP)
Type
Order No.
Line voltage 380 V to 480 V 3 AC
210
110 (150)
6SL3310-1TE32-1AA0
6SL3000-0BE32-5AA0
260
132 (200)
6SL3310-1TE32-6AA0
6SL3000-0BE34-4AA0
310
160 (250)
6SL3310-1TE33-1AA0
6SL3000-0BE34-4AA0
380
200 (300)
6SL3310-1TE33-8AA0
6SL3000-0BE34-4AA0
490
250 (400)
6SL3310-1TE35-0AA0
6SL3000-0BE36-0AA0
Error processing SSI file
SINAMICS S120
Power Modules and line-side components
Power Modules in chassis format
Recommended line-side components
2/59
Siemens D 21.1 · 2006
2
Overview
Assignment of line-side power components to Power 
Modules in blocksize format
Suitable line-side power components are assigned depending 
on the power rating of the Power Modules.
The following tables list recommended components and apply 
for ambient temperatures up to 40°C (104 °F).
Further information about the main contactors, switch discon-
nectors, fuses and circuit-breakers specified in the tables can 
be found in Catalogs LV1, LV IT and ET BI. 
1)
1)
Component selections are per IEC standards and not necessarily in 
accordance with UL or NEC requirements. For NEMA components 
please see North American Industrial Products Catalog and Speedfax 
Catalog.
Rated 
output
current
Rated 
power
Suitable 
for PM340 
Power 
Module
Main con-
tactor
Circuit-breaker
Main switch
(switch
disconnector)
Fuse switch 
disconnector
Switch 
disconnector 
with fuse 
holders
Fuse
A
kW (HP)
Type 
6SL3310-...
Type
Order No.
Order No.
Order No.
Order No.
Order No.
Line voltage 380 V to 480 V 3 AC
210
110 (150) ) 1TE32-1AA0
3RT1064-...
3VL4725-1DC36-0AA0
3KA5530-1EE01
3NP4270-0CA01
3KL5530-1EB01
3NA3144
260
132 (200) ) 1TE32-6AA0
3RT1065-...
3VL4731-1DC36-0AA0
3KA5730-1EE01
3NP4370-0CA01
3KL5730-1EB01
3NA3250
310
160 (250) ) 1TE33-1AA0
3RT1066-...
3VL4740-1DC36-0AA0
3KA5730-1EE01
3NP4370-0CA01
3KL5730-1EB01
3NA3254
380
200 (300) ) 1TE33-8AA0
3RT1075-...
3VL5750-1DC36-0AA0
3KA5730-1EE01
3NP4370-0CA01
3KL5730-1EB01
3NA3260
490
250 (400) ) 1TE25-0AA0
3RT1076-...
3VL5763-1DC36-0AA0
3KA5830-1EE01
3NP4470-0CA01
3KL6130-1EB01
3NA3372
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/60
Siemens D 21.1 · 2006
2
Overview
A Basic Line Module converts an AC source into an unregulated 
DC supply. Basic Line Modules are used for applications in 
which no energy is returned to the supply or where the energy 
exchange between motor and generator axes takes place in the 
DC link. The connected Motor Modules are precharged via the 
thyristor gate control which supplies a DC voltage equal to 1.35 
x the line voltage. Basic Line Modules are designed for connec-
tion to grounded-neutral (TN, TT) and non-grounded (IT) supply 
systems.
Design
The Basic Line Modules in chassis format feature the following 
connections as standard:
• 1 power connection
• 1 connection for the 24 V DC electronics power supply
• 1 DC link connection
• 3 DRIVE-CLiQ sockets
The status of the Basic Line Modules is indicated via two multi-
color LEDs.
The scope of supply of the Basic Line Modules includes:
• 0.6 m (1.97 ft) DRIVE-CLiQ cable for connection to a CU320 
or SIMOTION D Control Unit
• 1.45 m (4.76 ft) DRIVE-CLiQ cable for connection between the 
Control Unit and first Motor Module
Selection and ordering data
Warning signs in foreign languages
Warning signs in other languages can be placed on top of the 
standard warning signs in German or English.
The following signs are supplied with chassis format units:
Chinese, Danish, Finnish, French, Greek, Italian, Japanese, 
Korean, Dutch, Polish, Portuguese, Russian, Swedish, Spanish, 
Czech and Turkish.
Infeed power
Basic Line Module in 
chassis format
kW (HP)
Order No.
Line voltage 380 V to 480 V 3 AC
200 (300)
6SL3330-1TE34-2AA0
250 (400)
6SL3330-1TE35-3AA0
400 (600)
6SL3330-1TE38-2AA0
560 (800)
6SL3330-1TE41-2AA0
710 (1000)
6SL3330-1TE41-5AA0
Line voltage 660 V to 690 V 3 AC
250 (400)
6SL3330-1TH33-0AA0
355 (476)
6SL3330-1TH34-3AA0
560 (800)
6SL3330-1TH36-8AA0
900 (1207)
6SL3330-1TH41-1AA0
1100 (1475)
6SL3330-1TH41-4AA0
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/61
Siemens D 21.1 · 2006
2
Integration
The Basic Line Module communicates with a CU320 or 
SIMOTION D Control Unit via DRIVE-CLiQ.
Connection example of Basic Line Module
X402
X401
X400
P24 V  
X9
U
1
V
1
W
1
Basic Line Module 
DCP
DCN
2
1
4
3
6
5
+
M
L3
L2
L1
H200
L
E
D
s
H201
-F10
-F11
Line reactor 
Input current 
Main switch/ 
circuit-breaker 
Line filter 
Main contactor 
G
_
D
2
1
1
_
E
N
_
0
0
0
1
0
b
ext. 
24 V 
Activation of 
main contactor 
Fan 
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
D
R
I
V
E
-
C
L
i
Q
s
o
c
k
e
t
1
2
0
DC link current 
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/62
Siemens D 21.1 · 2006
2
Technical data
General technical data
1)
The DC link voltage is unregulated and load-dependent. For further 
information see System Description.
Electrical data
Line connection voltage
(up to 2000m (6563 ft) above sea level)
380V to 480V 3 AC ±10% (–15%<1min) or
660V to 690V 3 AC ±10% (–15%<1min)
Power frequency
47 Hz to 63 Hz
Line power factor at rated output
•Fundamental Power factor
>0.96
•Total (λ)
0.75 to 0.93
Overvoltage category
Class III to EN 60664-1
DC link voltage
approx. 1.35 x line voltage 
1)
Electronics power supply
24V DC –15%/+20%
Main contactor control
•Terminal strip X9/5-6
240V AC/ max. 8A
30V DC/ max. 1A
Radio interference suppression
•Standard
No radio interference suppression
(Category C3 to EN61800-3 up to 300 m (984 ft) total cable length)
•With line filter
Category C2 to EN61800-3
Ambient conditions
Type of cooling
Forced air cooling through a built-in fan
Permissible ambient and coolant temperature (air) during 
operation for line-side components, Line Modules and Motor 
Modules
0 °C to + 40 °C (32 °F to +104° F) without derating, 
> 40 °C to + 55 °C (> 104 °F to +131 °F)see derating characteristics
Installation altitude
Up to 2000 m (6563 ft) above sea level without derating,
> 2000 m (6563 ft) to 4000 m (13126 ft) above sea level see derating 
characteristics
Certificates
Conformity
CE (low-voltage and EMC Directives)
Approvals
cULus (File No.: E192450)
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/63
Siemens D 21.1 · 2006
2
Technical data (continued)
1) Nominal HP ratings are provided for ease of assigning components 
only. The Line Module outputs are dependent on the Motor Module 
loading and are to be dimensioned accordingly.
Line voltage 
Basic Line Modules in chassis format
380 V to 480 V 3 AC
6SL3330-
1TE34-2AA0
6SL3330-
1TE35-3AA0
6SL3330-
1TE38-2AA0
6SL3330-
1TE41-2AA0
6SL3330-
1TE41-5AA0
Infeed power P
rated
with 400V 3 AC
with 460 V 3 AC 
1)
kW
(HP)
200
(300)
250
(400)
400
(600)
560
(800)
710
(1000)
Infeed power
for S6 duty (40%)P
S6
kW
On request
On request
On request
On request
On request
Max. infeed power P
max
(HP)
kW
300
(402)
375
(503)
600
(805)
840
(1126)
1065
(1428)
Rated DC link current 
I
rated_DC
A
420
530
820
1200
1500
DC link current I
H_DC
A
328
413
640
936
1170
Max. DC link current I
max_DC
A
630
795
1230
1800
2250
Input current
at V
line
=400V
A
365
460
710
1010
1265
Max. input current
at V
line
=400V
A
547
690
1065
1515
1897
Max. current requirement
24 V DC electronics power 
supply
A
1.1
1.1
1.1
1.1
1.1
DC link capacitance
µF
7200
9600
14600
23200
29000
Max. DC link capacitance of 
drive group
µF
57600
76800
116800
185600
232000
Efficiency 
η
0.991
0.992
0.992
0.992
0.992
Power loss
kW
1.9
2.1
3.2
4.6
5.5
Cooling air requirement
m
3
/s (ft
3
/s) 0.17 (6)
0.17 (6)
0.17 (6)
0.36 (12.71)
0.36 (12.71)
Sound pressure level at 
50/60 Hz
dB(A)
67/68
67/68
67/68
72/73
72/73
Power connection
U1, V1, W1
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M12 screw,
max. cross section 
6×240 mm
2
Flange connection 
with M12 screw,
max. cross section 
6×240 mm
2
DC link connection
DCP, DCN
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
Flange connection 
with M12 screw,
max. cross section 
2×240 mm
2
Flange connection 
with M12 screw,
max. cross section 
2×240 mm
2
PE connection
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M10 screw,
max. cross section 
2×240 mm
2
On housing with 
M10 screw,
max. cross section 
2×240 mm
2
Max. cable length (total of all 
motor cables and DC link)
m (ft)
1500 (4921)
1500 (4921)
1500 (4921)
2250 (7382)
2250 (7382)
Degree of protection
IP00
IP00
IP00
IP00
IP00
Width
mm (inch) ) 305 (12)
305 (12)
305 (12)
305 (12)
305 (12)
Height
mm (inch) ) 1160 (45.67)
1160 (45.67)
1160 (45.67)
1650 (64.96)
1650 (64.96)
Depth
mm (inch) ) 351 (13.82)
351 (13.82)
351 (13.82)
550 (21.65)
550 (21.65)
Size
FB
FB
FB
GB
GB
Weight, approx.
kg (lb)
86 (190)
86 (190)
86 (190)
214 (472)
214 (472)
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/64
Siemens D 21.1 · 2006
2
Technical data (continued)
Line voltage 
Basic Line Modules in chassis format
660 V to 690 V 3 AC
6SL3330-
1TH33-0AA0
6SL3330-
1TH34-3AA0
6SL3330-
1TH36-8AA0
6SL3330-
1TH41-1AA0
6SL3330-
1TH41-4AA0
Infeed power P
rated
with 690V 3 AC
kW
250
355
560
900
1100
Infeed power
for S6 duty (40%)P
S6
kW
On request
On request
On request
On request
On request
Max. infeed power P
max
(HP)
kW
375
(503)
532.5
(714)
840
(1126)
1350
(1810)
1650
(2213)
Rated DC link current 
I
rated_DC
A
300
430
680
1100
1400
DC link current I
H_DC
A
234
335
530
858
1092
Max. DC link current I
max_DC
A
450
645
1020
1650
2100
Input current
at V
line
=690V
A
260
375
575
925
1180
Max. input current
at V
line
=690V
A
390
562.5
862.5
1387.5
1770
Max. current requirement
24 V DC electronics power 
supply
A
1.1
1.1
1.1
1.1
1.1
DC link capacitance
µF
3200
4800
7300
11600
15470
Max. DC link capacitance of 
drive group
µF
25600
38400
58400
92800
123760
Efficiency 
η
0.994
0.994
0.995
0.994
0.995
Power loss
kW
1.5
2.1
3.0
5.4
5.8
Cooling air requirement
m
3
/s (ft
3
/s) 0.17 (6)
0.17 (6)
0.17 (6)
0.36 (12.71)
0.36 (12.71)
Sound pressure level at 
50/60 Hz
dB(A)
67/68
67/68
67/68
72/73
72/73
Power connection
U1, V1, W1
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
for busbar connec-
tion with M12 screw 
or with adapter 
max. cross section 
6×240 mm
2
Flange connection 
for busbar connec-
tion with M12 screw 
or with adapter 
max. cross section 
6×240 mm
2
DC link connection
DCP, DCN
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
with M10 screw,
max. cross section 
2×185mm
2
with adapter max. 
cross section 3 x 
240 mm
2
Flange connection 
for busbar connec-
tion with M12 screw 
or with adapter 
max. cross section 
6×240 mm
2
Flange connection 
for busbar connec-
tion with M12 screw 
or with adapter 
max. cross section 
6×240 mm
2
PE connection
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M10 screw,
max. cross section 
2×185 mm
2
On housing with 
M12 screw,
max. cross section 
4×240 mm
2
On housing with 
M12 screw,
max. cross section 
4×240 mm
2
Max. cable length (total of all 
motor cables and DC link)
m (ft)
1500 (4921)
1500 (4921)
1500 (4921)
2250 (7382)
2250 (7382)
Degree of protection
IP00
IP00
IP00
IP00
IP00
Width
mm (inch) ) 305 (12)
305 (12)
305 (12)
305 (12)
305 (12)
Height
mm (inch) ) 1160 (45.67)
1160 (45.67)
1160 (45.67)
1650 (64.96)
1650 (64.96)
Depth
mm (inch) ) 351 (13.82)
351 (13.82)
351 (13.82)
550 (21.65)
550 (21.65)
Size
FB
FB
FB
GB
GB
Weight, approx.
kg (lb)
86 (190)
86 (190)
86 (190)
214 (472)
214 (472)
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
2/65
Siemens D 21.1 · 2006
2
Characteristics
Overload capability
Overload capability
Derating characteristics
Current derating dependent on ambient temperature
Note
: A derating factor k
T
>1.0 is to be taken into account only 
in conjunction with "current derating dependent on installation 
altitude". See also System description.
Current derating dependent on installation altitude
Voltage derating dependent on installation altitude
5 s
300 s
max_DC
H_DC
H_DC
60 s
t
1.5 x
rated_DC
G
_
D
2
1
1
_
E
N
_
0
0
0
3
6
a
Ambient temperature
G
_
D
2
1
1
_
E
N
_
0
0
0
0
4
k
T
D
e
r
a
t
i
n
g
f
a
c
t
o
r
1.3
1.2
1.1
1.0
0.9
0.8
20            25            30             35             40             45             50 oC     55
(68)         (77)          (86)          (95)         (104)        (113)        (122)   (oF) (131)
l
l
l
1000
2000
m
0
3000
4000
G
_
D
2
1
1
_
E
N
_
0
0
0
0
5
P
e
r
m
i
s
s
i
b
l
e
c
o
n
t
i
n
u
o
u
s
c
u
r
r
e
n
t
i
n
%
o
f
r
a
t
e
d
c
u
r
r
e
n
t
D
e
r
a
t
i
n
g
f
a
c
t
o
r
k
l
1.00
0.95
0.90
0.85
100
95
90
85
Installation altitude above sea level
(3282)                     (6563)                      (9845)     (ft)     (13126)
P
e
r
m
i
s
s
i
b
l
e
i
n
p
u
t
v
o
l
t
a
g
e
i
n
%
o
f
r
a
t
e
d
v
o
l
t
a
g
e
G
_
D
2
1
1
_
E
N
_
0
0
0
0
6
(3282) 
(6563) 
(9845) (ft) ) (13126)
100
90
80
70
1.0
0.9
0.7
0.8
Installation altitude above sea level
D
e
r
a
t
i
n
g
f
a
c
t
o
r
k
U
1000 
2000 
m
0
3000
4000
Error processing SSI file
SINAMICS S120
Line Modules and line-side components
Basic Line Modules in chassis format
Line reactors
2/66
Siemens D 21.1 · 2006
2
Overview
Line reactors reduce harmonic currents on the supply system 
and limit commutating dips in the Basic Line Module. For this 
reason, line reactors should always be used.
Selection and ordering data
Technical data
Infeed power 
of the Basic Line 
Module
Suitable for 
Basic Line Module
Line reactor
kW (HP)
Order No.
Line voltage 380 V to 480 V 3 AC
200 (300)
6SL3330-1TE34-2AA0
6SL3000-0CE35-1AA0
250 (400)
6SL3330-1TE35-3AA0
6SL3000-0CE35-1AA0
400 (600)
6SL3330-1TE38-2AA0
6SL3000-0CE37-7AA0
560 (800)
6SL3330-1TE41-2AA0
6SL3000-0CE41-0AA0
710 (1000)
6SL3330-1TE41-5AA0
6SL3000-0CE41-5AA0
Line voltage 660 V to 690 V 3 AC
250
6SL3330-1TH33-0AA0
6SL3000-0CH32-7AA0
355
6SL3330-1TH34-3AA0
6SL3000-0CH34-8AA0
560 
6SL3330-1TH36-8AA0
6SL3000-0CH36-0AA0
900 
6SL3330-1TH41-1AA0
6SL3000-0CH41-2AA0
1100
6SL3330-1TH41-4AA0
6SL3000-0CH41-2AA0
Line voltage 
Line reactor
380 V to 480 V 3 AC
6SL3000-0CE35-1AA0
6SL3000-
0CE37-7AA0
6SL3000-
0CE41-0AA0
6SL3000-
0CE41-5AA0
Max. thermal current I
th max
A
508
508
773
1022
1485
Power loss 50Hz/60Hz
kW
0.292/0.328
0.323/0.365
0.310/0.351
0.441/0.498
0.687/0.776
Line/load connection
M12 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
Degree of protection
IP00
IP00
IP00
IP00
IP00
Width
mm (inch) ) 300 (11.81)
300 (11.81)
300 (11.81)
350 (13.78)
460 (18.11)
Height
mm (inch) ) 269 (10.59)
269 (10.59)
269 (10.59)
321 (12.64)
435 (17.13)
Depth
mm (inch) ) 212.5 (8.37)
212.5 (8.37)
212.5 (8.37)
211.5 (8.33)
235 (9.25)
Weight, approx.
kg (lb)
38.0 (84)
38.0 (84)
51.3 (113)
69.6 (154)
118 (260)
Suitable for
Basic Line Module
Type
6SL3330-
1TE34-2AA0
6SL3330-
1TE35-3AA0
6SL3330-
1TE38-2AA0
6SL3330-
1TE41-2AA0
6SL3330-
1TE41-5AA0
Line voltage 
Line reactor
660 V to 690 V 3 AC
6SL3000-
0CH32-7AA0
6SL3000-
0CH34-8AA0
6SL3000-
0CH36-0AA0
6SL3000-0CH41-2AA0
Max. thermal current I
th max
A
270
482
597
1167
1167
Power loss 50Hz/60Hz
kW
0.245/0.277
0.424/0.478
0.430/0.485
0.620/0.697
0.693/0.783
Line/load connection
M10 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
M12 connecting 
lugs
Degree of protection
IP00
IP00
IP00
IP00
IP00
Width
mm (inch) ) 270 (10.63)
350 (13.78)
350 (13.78)
460 (18.11)
460 (18.11)
Height
mm (inch) ) 248 (9.76)
321 (12.64)
321 (12.64)
435 (17.13)
435 (17.13)
Depth
mm (inch) ) 200 (7.87)
232.5 (9.15)
232.5 (9.15)
235 (9.25)
235 (9.25)
Weight, approx.
kg (lb)
27.9 (62)
55.6 (123)
63.8 (141)
147 (324)
147 (324)
Suitable for
Basic Line Module
Type
6SL3330-
1TH33-0AA0
6SL3330-
1TH34-3AA0
6SL3330-
1TH36-8AA0
6SL3330-
1TH41-1AA0
6SL3330-
1TH41-4AA0
Error processing SSI file