Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
101 
4. Close the Connection Manager. 
4. Under System Management Tools, select Security > 
Mappings & Trusts. 
5. Verify that PIBuffSubSystemService is listed in the Trusts 
tab. 
6. Exit the System Management Tools. 
7. Go to Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > Interface Configuration Utility. The Interface 
Configuration Utility dialog box appears. 
8. From the Interface list, select the name of the FactoryTalk 
Historian Live Data Interface. 
9. From the menu bar, select Tools > Buffering. The Buffering 
dialog box appears. 
10. In the Choose Buffer Type pane, select the Enable buffering 
with PI Buffer Subsystem option. 
11. Click Yes in the confirmation message box that appears. Wait 
until the status box at the bottom of the Buffering dialog box 
displays Current Configuration: Good. 
NOTE 
If you delete an interface and recreate the interface (with the same 
ID) on another computer, you will get errors unless you restart the 
computer on which the deleted interface was located. Restarting 
the computer ensures the restarting of the buffering subsystem. 
Convert multi page pdf to jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
convert pdf pictures to jpg; convert pdf pages to jpg
Convert multi page pdf to jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert online pdf to jpg; batch pdf to jpg online
Chapter 6 Configuring FactoryTalk Historian 
102 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
As a general rule, you must always disable buffering on the 
interface before you delete it. If you forget to disable buffering, 
you will have to restart the computer to make sure the 
buffering subsystem is restarted. 
12. Select Buffered Servers in the left pane of the dialog box. 
From the Buffering to collective/server drop-down list, 
select the name of the computer on which the FactoryTalk 
Historian Live Data Interface is installed, and click Yes in to 
the confirmation message box. 
13. Click OK to close the Buffering dialog box. 
14. From the tree in the Interface Configuration Utility dialog 
box, select Service. 
15. In the Dependencies box, add the pibufss service from the 
Installed services list. 
NOTE 
Add pibufss as a dependent service to make sure your interface 
always starts after the buffering service starts. 
IMPORTANT 
If the interface starts before the buffering subsystem, data will 
be lost. 
16. On the toolbar, click 
to restart the interface. 
17. Verify that the status bar at the bottom of the dialog box 
displays the status Ready and Running. 
18. Click Close to exit the Interface Configuration Utility 
dialog box. The buffering service is now configured. 
C# TIFF: C#.NET Code to Convert JPEG Images to TIFF
Gif, and REImage object to single or multi-page Tiff image Use C# Code to Convert Jpeg to Tiff. string[] imagePaths = { @"C:\demo1.jpg", @"C:\demo2.jpg", @"C
change pdf to jpg image; convert pdf to jpeg on
C# PDF Convert to Tiff SDK: Convert PDF to tiff images in C#.net
Using this .NET PDF to TIFF conversion control, C# developers can render and convert PDF document to TIFF image Both single page and multi-page Tiff image
convert .pdf to .jpg online; change format from pdf to jpg
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
103 
NOTE 
If you want to configure a remote FactoryTalk Historian Live Data 
Interface to start from a local cache file with or without a valid 
connection to the host FactoryTalk Historian Server, enable the 
Disconnected Startup feature. For more information, refer to the KB 
article 66883 
(https://rockwellautomation.custhelp.com/app/answers/detail/a_i
d/66883). 
To manually enable Excel Add-ins for FactoryTalk Historian 
DataLink, FactoryTalk Historian Management Tools, and MDB 
Builder: 
1. Start Microsoft Excel. 
2. Select Office Button > Excel Options. The Excel Options 
dialog box appears. 
3. Click Add-Ins. 
4. At the bottom of the page, click Go. The Add-Ins dialog box 
appears. 
5. Click Browse. The Browse dialog box appears. 
6. Navigate to and select the following files: 
• for FactoryTalk Historian DataLink: 
...\Program Files (x86)\Rockwell Software\FactoryTalk 
Historian\PIPC\Excel\: 
• PITrendXL.xla 
• pipc32.xll 
• pidldialogs.xla 
• for FactoryTalk Historian Management Tools: 
...\Program Files (x86)\Rockwell Software\FactoryTalk 
Historian\PIPC\SMT\: 
Manually Enabling Excel 
Add-ins 
C# Word - Convert Word to JPEG in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel component toolkit, C# developers can easily and quickly convert a large-size multi-page Word document
bulk pdf to jpg converter online; convert pdf to jpg for online
C# powerpoint - Convert PowerPoint to JPEG in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET component toolkit, C# developers can easily and quickly convert a large-size multi-page PowerPoint document
convert pdf into jpg format; reader convert pdf to jpg
Chapter 6 Configuring FactoryTalk Historian 
104 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
• PITagCnf.xla 
• for MDB Builder: 
...\Program Files (x86)\Rockwell Software\FactoryTalk 
Historian\PIPC\MDBBuilder\: 
• MDBBuilder.xla 
7. Click OK after selecting each file. The file is added to the 
Add-Ins available list. 
8. Click OK to close the dialog box. The tabs with the selected 
Excel Add-ins are added to the ribbon. 
FactoryTalk Historian SE uses the FactoryTalk Diagnostics 
component of the FactoryTalk Services Platform to record messages 
sent by the FactoryTalk Historian SE server. In the event of a 
message, the FactoryTalk server logs it in the FactoryTalk 
Diagnostics service. 
If the FactoryTalk Historian SE server cannot connect to the 
FactoryTalk Diagnostics service, the server will log the messages in 
the Windows Event log and continue to reconnect to FactoryTalk 
Diagnostics service. Once the server reconnects to the FactoryTalk 
Diagnostics service, a message is logged indicating that some 
messages may not have been logged and will advise you to check the 
local Windows Event log. 
Each message logged to the FactoryTalk Diagnostics service contains 
the following information: 
Item name 
Description 
Date/Time 
The date and time the message was recorded. The time is the local 
time for the server. This is important to note if you are in a different 
time zone than the server. 
Recording Messages Using 
FactoryTalk Diagnostics 
Message Parameters 
JPG to PNG Converter | Convert JPEG to PNG, Convert PNG to JPG
& pixel depth; Ability to convert single-page images between Select "Convert to PNG"; Select "Start" to start JPEG to PNG Converter first; Load JPG images from
convert pdf file to jpg online; convert pdf to gif or jpg
C# Excel - Convert Excel to JPEG in C#.NET
VB.NET How-to, VB.NET PDF, VB.NET Word, VB.NET Excel component toolkit, C# developers can easily and quickly convert a large-size multi-page Excel document
change pdf to jpg online; change pdf to jpg on
Configuring FactoryTalk Historian Chapter 6 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
105 
Item name 
Description 
User Name 
The name of the user that performed or requested an operation 
that generated the error message. 
Note: If you plan to track user IDs in FactoryTalk Diagnostics for 
auditing purposes, you must create identical user IDs in the 
FactoryTalk Historian SE. Refer to the FT Historian SE System 
Management Guide for information on creating user IDs in the 
Historian server. 
User Description 
The full name of the user. 
Severity  
All messages are logged as Warning or Informational. 
Audience  
Engineer is the default audience type for all messages. 
Message text 
A description of the error that occurred. 
Location  
The name of the computer where the diagnostic message was 
generated. 
Provider  
The name of the FactoryTalk product or subsystem that generated 
the message. 
To view the messages in FactoryTalk Diagnostics, run the 
FactoryTalk Diagnostics Viewer tool. See the FactoryTalk 
Diagnostics Viewer Help for more information. 
To view messages stored in the Windows Event log, click Start > 
Settings > Control Panel > Administrative Tools > Event Viewer. 
Viewing Messages 
JPEG to PDF Converter | Convert JPEG to PDF, Convert PDF to JPEG
Convert JPEG (JPG) Images to, from PDF Images on Windows. Features and Benefits. Powerful image converter to convert images of JPG, JPEG formats to PDF files;
convert pdf to jpg batch; batch pdf to jpg converter online
C# Imaging - Planet Barcode Generation Guide
bar codes on documents such as PDF, Office Word, Excel, PowerPoint and multi-page TIFF. BarcodeHeight = 200; barcode.AutoResize = true; //convert barcode to
convert pdf into jpg online; change file from pdf to jpg
Chapter 6 Configuring FactoryTalk Historian 
106 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
JPG to GIF Converter | Convert JPEG to GIF, Convert GIF to JPG
Converter. Convert JPEG (JPG) Images to, from GIF Images on Windows. JPEG to GIF Converter can directly convert GIF files to JPG files.
convert pdf file to jpg format; convert pdf photo to jpg
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
107 
Chapter 7 
Troubleshooting FactoryTalk Historian 
In this chapter you will learn how to: 
• Use FactoryTalk Historian ME modules with FactoryTalk 
Security (page 107). 
• Verify the Windows Administrator privileges (page 108). 
• Resolve error and warning messages (page 109). 
If you are using FactoryTalk Security to authenticate your 
FactoryTalk Historian ME 1756-HISTxG module, and you want to 
establish a connection between the Historian ME and SE modules, 
you need to make sure the following FactoryTalk Security groups are 
created in FactoryTalk Historian SE: 
• FTHAdministrators 
• FTHEngineers 
• FTHSupervisors 
• FTHOperators 
To verify that these four user groups were created: 
1. Click Start > All Programs > Rockwell Software > FactoryTalk 
Administration Console. The FactoryTalk Administration 
Console dialog box appears. 
2. In the Select FactoryTalk Directory dialog box, select 
Network, and click OK. 
3. In the Explorer tree, expand Users and Groups > User 
Groups. 
Using FactoryTalk Historian 
ME Modules with 
FactoryTalk Security 
Chapter 7 Troubleshooting FactoryTalk Historian 
108 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
The folder should include the four FactoryTalk Historian user 
groups: 
If you do not see the four user groups, do the following on the 
FactoryTalk Directory server computer: 
1. Log on to Windows as the local Administrator. 
2. Log on to FactoryTalk as a member of the FactoryTalk 
Administrators user group. 
3. Open the FactoryTalk Administration Console, and create a 
computer account for each FactoryTalk Historian SE host. 
4. On the FactoryTalk Historian SE installation DVD, navigate 
to Redist > FTHME Security. 
5. Double-click the FTHMESecurityUpdate.bat file. 
6. Return to FactoryTalk Administration Console and verify 
that the user groups have been created. 
To verify that the Windows Administrators group is part of the 
FTHAdministrators group: 
1. In FactoryTalk Administration Console, expand Users and 
Groups > User Groups. 
2. Double-click the FTHAdministrators group. The 
FTHAdministrators Properties dialog box appears. 
Verifying the Windows 
Administrator Privileges 
Troubleshooting FactoryTalk Historian Chapter 7 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
109 
The Windows Administrators group should appear in the 
Members list. If it does not, do the following: 
1. Click Add. The Select User or Group dialog box appears. 
2. Select Windows Administrators and click OK. The group 
is added to the FTHAdministrators group. 
3. Click OK to close the dialog box. 
Use this section to find information about the following types of 
error and warning messages: 
• General (page 109) 
• No Connection to FactoryTalk Directory (page 111) 
Use this section to find information about the following error 
messages: 
• Error: System is a PINs Node (page 109) 
• Error: Server Not Found (page 110) 
• Error: Failure to Retrieve Interface Information (page 111) 
Message 
FactoryTalk Historian SE server setup has determined that this is a 
PINS node. The FactoryTalk server installation cannot continue. 
Please completely remove the Historian SDK and rerun setup. 
Cause 
The error occurs if you install a FactoryTalk Historian SE server on a 
computer that already has FactoryTalk Historian SE Clients 
(ProcessBook, DataLink) or components (System Management 
Tools) installed. 
Resolution 
Remove the Historian Software Development Kit (Historian SDK) 
using Control Panel > Programs > Programs and Features. 
Resolving Error and 
Warning Messages 
General 
Error: System is a PINs Node 
Chapter 7 Troubleshooting FactoryTalk Historian 
110 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
Message 
The requested server <FTHSE-SRV> was not found in the known 
servers table. 
Cause 
The error occurs when you try to create a new Data Collection 
Interface from a computer that has FactoryTalk Historian SE Live 
Data Interface installed. Your client computer could not locate the 
FactoryTalk Historian SE server. 
Resolution 
Manually create a connection to the FactoryTalk Historian SE 
server computer. See the instruction below. 
To manually create a connection to the FactoryTalk Historian 
SE server computer: 
1. On your client computer, go to Start > All Programs > 
Rockwell Software > FactoryTalk Historian SE System 
Management Tools. The System Management Tools dialog 
box appears. 
2. From the menu bar, select File > Connections. The 
Connection Manager dialog box appears. 
3. Select the FactoryTalk Historian SE server to which you want 
to connect. 
If the server name is not listed, do the following: 
1. From the menu bar, select Server > Add Server. The Add 
Server dialog box appears. 
2. In the Network Node text box, type the fully qualified 
domain name (FQDN) of the server. 
3. Clear the Confirm check box, and click OK. 
The new server is added to the server list. 
Error: Server Not Found 
Documents you may be interested
Documents you may be interested