Installing FactoryTalk Historian Chapter 4 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
51 
• OPC DA Server 
• OPC HDA Server 
• OPC HDA DA Server 
• WebServices 
• Notifications for using Microsoft Lync Unified 
Communication Server 
New users may activate the Advanced Server components with the 
FTHSE.Advanced license activation. 
For the users upgrading their license activations from FactoryTalk 
Historian SE 2.2/2.1, the Advanced Server components are 
activated automatically when the total license count of the FHLD 
and PTY3 license activations is at least 250. 
To install the Advanced Server components: 
1. Open the FactoryTalk Historian SE installation DVD. 
2. Go to the Redist\Advanced Server Options folder. 
3. Choose the components you want to install. 
4. Follow the on-screen instructions to complete the process. 
To activate the Advanced Server components: 
• See "Activating FactoryTalk Historian SE Server (page 61)" to 
learn about the activation process. 
• See "Types of Licenses (page 78)" to learn about the license 
activation. 
Convert pdf to 300 dpi jpg - Convert PDF to JPEG images in C#.net, ASP.NET MVC, WinForms, WPF project
How to convert PDF to JPEG using C#.NET PDF to JPEG conversion / converter library control SDK
bulk pdf to jpg converter; convert .pdf to .jpg
Convert pdf to 300 dpi jpg - VB.NET PDF Convert to Jpeg SDK: Convert PDF to JPEG images in vb.net, ASP.NET MVC, WinForms, WPF project
Online Tutorial for PDF to JPEG (JPG) Conversion in VB.NET Image Application
convert pdf to gif or jpg; convert pdf pages to jpg
Chapter 4 Installing FactoryTalk Historian 
52 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
The data from multiple FactoryTalk Historian SE servers and 
FactoryTalk Historian ME servers can be brought together into a 
single information management and decision support system using 
FactoryTalk VantagePoint. 
For detailed instructions on installing FactoryTalk VantagePoint 
and its components, refer to the FactoryTalk VantagePoint 
documentation. 
The FactoryTalk Historian SE DVD contains several optional 
Historian components used for data management, such as 
FactoryTalk Historian DataLink or PerfMon Health Monitor. 
These components are located in the Redist folder on the 
installation DVD. 
If you choose to install these components, be sure to install them 
after you install FactoryTalk Historian SE. For further information 
regarding these components, refer to the FactoryTalk Historian SE 
documentation, available in the Redist\Docs folder on the 
FactoryTalk Historian SE installation DVD. 
Install FactoryTalk 
VantagePoint (Optional) 
Install Additional Historian 
Components 
VB.NET PDF Convert to Images SDK: Convert PDF to png, gif images
page As PDFPage = doc.GetPage(0) ' Convert the first New PDFDocument(inputFilePath) ' Get the first page of PDF. Render the page with a resolution of 300 dpi.
change from pdf to jpg on; changing pdf to jpg file
C# PDF Convert to Images SDK: Convert PDF to png, gif images in C#
int targetResolution = 300; Bitmap bitmap3 = page.GetBitmap(targetResolution); bitmap3.Save(inputFilePath + "_3 Description: Convert all the PDF pages to
convert pdf pages to jpg online; convert pdf to jpg
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
53 
Chapter 5 
Post-Installation Tasks 
In this chapter you will learn about the following tasks that you 
should perform after installing FactoryTalk Historian SE: 
• View the Historian server installation log file. (page 53) 
• Verify that Historian services are running. (page 53) 
• Verify that Historian server is updating data for default tags. 
(page 54) 
• Add the AF Service computer to the AFServer group. (page 
55) 
• Manually create the Asset Framework database. (page 56) 
• Manually configure the Asset Framework service. (page 58) 
• Perform the MDB to AF synchronization. (page 59) 
• Verify the MDB to AF synchronization. (page 59) 
• Disable virus scanning. (page 60) 
You can open the installation log, fth_installer.log, directly from 
the installation wizard. If you want to refer to it later, open it from 
the following location: 
C:\Program Files\Rockwell Software\FactoryTalk 
Historian\Installation Manager\<Name of the Historian 
suite>\FTHInstallerLogs\<Date and Time of the Installation>. 
Use Historian Services in System Management Tools to view, 
configure, start and stop Historian services for each connected 
Historian server. The status of each service is updated every 30 
seconds by default. You may change this refresh rate. You can also 
View the Installation Log 
File 
Verify that Historian 
Services are Running 
Chapter 5 Post-Installation Tasks 
54 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
view the status, errors, and thread details for services used by the 
connected Historian server, and export a list of Historian services. 
To open Historian services: 
1. Click Start > Program Files > Rockwell Software > FactoryTalk 
Historian SE > System Management Tools. The System 
Management Tools dialog box appears. 
2. Under Collectives and Servers, select the server for which you 
want to view the information. 
3. Under System Management Tools, select Operation > PI 
Services. 
4. Verify that the following Historian services and default 
interfaces are running: 
• Archive Subsystem 
• Backup Subsystem 
• Base Subsystem 
• License Manager 
• Network Manager 
• Ramp Soak Simulator (rmp_sk) Interface 
• Random Simulator (random) Interface 
• Snapshot Subsystem 
• SQL Subsystem 
• Update Manager 
Depending on your license, you might see additional services. 
Post-Installation Tasks Chapter 5 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
55 
To verify that the Historian server is updating data for default 
tags: 
1. On the computer with the Historian server installed, go to 
Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > System Management Tools. The System 
Management Tools dialog box appears. 
2. Under Collectives and Servers, select the Historian server 
whose data you want to view. 
3. Under System Management Tools, select Data > Archive 
Editor. 
4. In the (Tag Not Specified) tab, click 
. The Tag Search 
dialog box appears. 
5. In the Tag Mask text box, type cdt158, and click Search. 
The cdt158 tag appears in the search results list. 
6. Click OK. 
The list of events of the selected tag is displayed in the tab in 
the right pane of the System Management Tools dialog box. 
NOTE 
For more information on the Archive Editor, click 
NOTE 
This procedure applies if you have selected either of the following 
installation modes of FactoryTalk Historian Asset Framework: 
• AF SQL Database. 
• AF SQL Database with unprocessed database scripts. 
See "Installation Modes for FactoryTalk Historian Asset Framework 
(page 34)" for information on the installation modes. 
Verify that the Historian 
Server is Updating Data for 
Default Tags 
Add the AF Service 
Computer to the AFServer 
Group 
Chapter 5 Post-Installation Tasks 
56 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
To add the computer with the AF service installed to the 
AFServer group: 
1. Go to Start > All Programs > Administrative Tools > Computer 
Management. The Computer Management dialog box 
appears. 
2. In the explorer tree, select System Tools > Local Users and 
Groups > Groups. 
3. In the right pane, right-click the AFServers group, and select 
Add to Group. 
4. In the AFServers Properties dialog box, click Add. 
5. In the Select Users, Computers, Service Accounts, or 
Groups dialog box, type the name of the machine with the AF 
service installed in the text box, and click Check Names to 
verify the name. 
6. Click OK to exit the dialog boxes. 
NOTE 
This procedure applies if you have selected either of the following 
installation modes of FactoryTalk Historian Asset Framework: 
• AF Application Service and AF SQL Database with unprocessed 
database scripts. 
• AF SQL Database with unprocessed database scripts. 
See "Installation Modes for FactoryTalk Historian Asset Framework 
(page 34)" for information on the installation modes. 
If you have installed FactoryTalk Historian Asset Framework with 
unprocessed scripts, you need to create the AF SQL database 
manually using the scripts. The scripts create the AF SQL database 
called PIFD and populate its tables. 
NOTE 
To execute the scripts, you must have sysadmin privileges on the 
SQL Server instance. 
Manually Create the Asset 
Framework Database 
Post-Installation Tasks Chapter 5 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
57 
To manually create the Asset Framework SQL PIFD database: 
1. On the computer to which the unprocessed database scripts 
were copied during the FactoryTalk Historian Asset 
Framework installation process, open the Command Prompt 
window and navigate to the following folder in the Program 
Files directory: Rockwell Software\FactoryTalk 
Historian\PIPC\AF\SQL. 
2. Call the GO.bat file with the following parameters, depending 
on the user authentication method: 
• SQL Server authentication: 
GO.bat SQLServer\SQLInstance PIFD SQLServerLogin 
SQLServerPassword, where: 
• SQLServer is the name of the SQL Server machine on 
which the PIFD database will be installed. 
• SQLInstance is the name of the instance of the SQL 
Server. This parameter is required if the SQL Server has 
been installed with an instance name. 
• SQLServerLogin is the SQL Server user name. 
• SQLServerPassword is the password of the SQL Server 
user. 
• Windows authentication: 
GO.bat SQLServer\SQLInstance PIFD 
3. Press Enter to start the database creation process. 
The end of the process is indicated with an underscore at the 
command prompt. 
Once the database is created, you need to configure the Asset 
Framework service to communicate with the database. See 
"Manually Configure the Asset Framework Service (page 58)" for 
more information. 
Chapter 5 Post-Installation Tasks 
58 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
NOTE 
Perform the steps described below on each computer with the Asset 
Framework service installed. 
To configure the AF service to communicate with the PIFD SQL 
database: 
1. In Windows Explorer, navigate to the following folder in the 
Program Files directory: Rockwell Software\FactoryTalk 
Historian\PIPC\AF\. 
2. Open the AFService.exe.config file in a text editor. 
3. Navigate to the <appSettings> section, and in the add element 
with the key=connectString attribute update the values of 
the server attribute: 
server=SQLServer\SQLInstance 
For example: 
• If the SQL Server is running on a computer cluster, type the 
IP address of the clustered resource as the SQLServer value. 
• If the SQL Server is configured to use the SQL Server 
database mirroring, add the failover partner attribute after 
the server attribute with the following values: 
failover partner=SQLServer\SQLInstance 
For example: 
Manually Configure the 
Asset Framework Service 
Post-Installation Tasks Chapter 5 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
59 
• If you want to enable the encrypted communication 
between the AF service and the AF SQL database, add the 
encrypt=Yes attribute to the code, for example: 
• If you want to configure other options, refer to the 
Microsoft SQL Native Client documentation. 
4. Save the file. 
5. If the Asset Framework service is running, restart it for the 
changes to take effect: 
1. Go to Start > All Programs > Administrative Tools > 
Services. 
2. In the Services dialog box, right-click PI AF Server 2.x and 
select Restart. 
Once you have the FactoryTalk Historian Asset Framework and the 
FactoryTalk Historian SE Server installed, you need to set up 
synchronization between the AF service and the Historian server. 
This process is called the MDB to AF transition. For more 
information, refer to the FT Historian SE MDB to AF Transition 
Guide. 
To verify the MDB to AF synchronization: 
1. Click Start > All Programs > Rockwell Software > FactoryTalk 
Historian SE > System Management Tools. The System 
Management Tools dialog box appears. 
Perform the MDB to AF 
Synchronization 
Verify the MDB to AF 
Synchronization 
Chapter 5 Post-Installation Tasks 
60 
Rockwell Automation Publication HSE-IN024A-EN-E–December 2012 
2. Under System Management Tools, select Operation > MDB 
to AF Synchronization. 
3. Select the Historian server for which you want to verify the 
synchronization. 
• If the synchronization is operating correctly, a green icon 
appears next to the name of the server. 
• If the synchronization fails, a red icon appears. Click 
in 
the System Management Tools dialog box for information 
on how to diagnose and solve the problem. 
Rockwell Automation considers it a good practice to exclude the 
following directories from anti-virus software scanning: 
• On Historian server computers, exclude the Server\dat 
directory and any directory where archive or event queue files 
are located. 
• For Interface nodes, exclude the pipc\dat and pipc\log 
directories, as well as the directory where buffer queue files are 
located. 
By excluding these directories you avoid random signature match 
incidents, potential performance impacts, and conflicts with locked 
files. 
NOTE 
For more details, see the FT Historian SE Server Reference Guide, 
available in the Redist\Docs folder on the FactoryTalk Historian SE 
installation DVD and in the Common Files\Rockwell\Help folder in 
your Program Files directory. 