asp net core 2.0 mvc pdf : Append pdf Library control class asp.net azure windows ajax Mastering-EES-Chapter12-part1078

Chapter 1: Introduction to EES 
21 
c
V
u
A
=
(1-13) 
u=V_dot/A_c 
"velocity, in liter/min-cm^2"
As written, the units for the variable 
u
must be liter/min (the units for the variable 
V_dot
) divided 
by cm
2
(the units for the variable 
A_c
).  Therefore, the units for 
u
must liter/min-cm
2
 Note that 
in this book, the hyphen sign will be used to indicate multiplication on one side of the divisor in 
the context of units; therefore liter/min-cm
2
should be read as 
2
liter
min cm
.  EES uses the same 
convention for unit specifications, although the hyphen can be replaced with a space or a dot 
(Alt-250 on a U.S. keyboard).   
The units for the variable 
u
, as calculated, don't make a lot of sense; let's convert the units to 
cm/min, which are more reasonable: 
3
2
liter
1000 cm
cm
min-cm
1 liter
min
=
(1-14) 
The EES code, with the unit conversion, is: 
u=(V_dot/A_c)*1000 
"velocity, in cm/min" 
Finally, Eq. (1-11) is used to compute the pressure loss. 
DELTAP=K*rho*u^2/2 
"pressure loss, in kPa" 
Again, the units for the variable 
DELTAP
don't make a lot of sense; as calculated, the units are kg-
cm
2
/m
3
-min
2
.  Nobody will understand your result when expressed in these units.  Let's convert 
to kPa, which are more commonly used: 
2
2
2
2
2
3
2
2
2
2 2
kg-cm
kPa-m
N-s
m
min
kPa
m-min 1000 N N kg-m100  cm m 60 0 s
=
(1-15) 
Notice that we had to look up four separate unit conversion factors in order to accomplish the 
unit conversion indicated by Eq. (1-15).  Section 1.5 shows that EES greatly reduces the hassle 
and potential errors that are associated with working with units. 
DELTAP=(K*rho*u^2/2)/(1000*100^2*60^2) 
"pressure loss, in kPa" 
Solving leads to ∆P = 4.22 kPa for V
= 100 liter/min.   
Append pdf - Merge, append PDF files in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provide C# Demo Codes for Merging and Appending PDF Document
adding pdf pages together; batch pdf merger online
Append pdf - VB.NET PDF File Merge Library: Merge, append PDF files in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Guide and Sample Codes to Merge PDF Documents in .NET Project
acrobat merge pdf files; add pdf together one file
Chapter 1: Introduction to EES 
22 
Creating a Parametric Table 
In order to parametrically vary the volumetric flow rate (the independent variable) and study its 
effect on the pressure loss (the dependent variable) we need to create a Parametric Table.  Select 
New Parametric Table from the Tables menu.  The New Parametric Table dialog will appear, as 
shown in Figure 1-21. 
Figure 1-22: New Parametric Table dialog. 
The window on the left side of the dialog provides a list of all of the variables that are included 
in the Equations Window.  Highlight the independent and dependent variables of interest (in this 
case, the variables 
V_dot
and 
DeltaP
) by clicking on them and then select Add to add the variables 
to the window on the right side, which lists variables to be included in the table.  Any other 
variables that you wish to include in the table can also be added.  You can select the variables 
one at a time or all at once.  Select OK in order to create the Parametric Table, shown in Figure 
1-22.  By default, there are 10 runs (rows) in the table.  Runs can be added or removed by 
selecting Insert/Delete Runs from the Tables menu or by right-clicking on any run number and 
selecting Insert Runs or Delete Runs.  There is a column for each of the variables included in the 
table.  Columns can be added or deleted by selecting Insert/Delete Vars from the Tables menu or 
right clicking on any variable and selecting Insert Column or Delete. 
Figure 1-23: Empty Parametric Table. 
Online Merge PDF files. Best free online merge PDF tool.
Online Merge PDF, Multiple PDF files into one. Download Free Trial. Merge PDF, Multiple PDF files. Drag and drop your PDF or several files in the box above.
pdf combine two pages into one; append pdf
C# TIFF: C#.NET Code to Merge and Append TIFF Files
Merge and Append Tiff Files. How to Merge and Append TIFF Files in C# by Using RasterEdge XDoc.Tiff for .NET SDK. Merge and Append TIFF Files in C#.NET Overview.
c# pdf merge; c# merge pdf files
Chapter 1: Introduction to EES 
23 
Alter Values 
To carry out a parametric study in which the volumetric flow rate is changed, it is necessary to 
fill in the column for the variable 
V_dot
with flow rate values that are of interest.  This process 
can be done manually, one run at a time.  More typically, you will right-click on the column of 
interest and select Alter Values or click on the triangular icon in the column header to bring up 
the dialog shown in Figure 1-23. 
Figure 1-24: Alter values dialog. 
Select the rows to be filled in (rows 1 to 10, for this example) and the pattern to be used to enter 
the values.  In Figure 1-23, the dialog is filled in so that the volumetric flow rate varies from 200 
liter/min (in row 1) to 2000 liter/min (in row 10) in equally spaced intervals, as shown in Figure 
1-24.  Other options can also be specified by clicking on the drop down menu under First Value.  
For plots that will use a logarithmic scale, the selection Last (Log) is particularly useful as it 
logarithmically spaces the values in the table. 
Figure 1-25: Parametric Table with values of 
V_dot
set. 
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Tell VB.NET users how to: create a new PDF file and load PDF from other file formats; merge, append, and split PDF files; insert, delete, move, rotate, copy
pdf mail merge plug in; combine pdfs online
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Tell C# users how to: create a new PDF file and load PDF from other file formats; merge, append, and split PDF files; insert, delete, move, rotate, copy and
pdf combine; pdf merge documents
Chapter 1: Introduction to EES 
24 
Solving a Parametric Table 
The Parametric Table is solved and filled in using the Solve Table command from the Calculate 
menu (or by pressing F3).  Solving the table prompts EES to solve one or more of the runs in the 
table.  EES will begin with the first run that is specified and look in the table to see which 
columns have specified values.  It will then specify the value of these variables in the Equations 
Window, solve the resulting system of equations, and fill in the values of the remaining columns 
based on the solution.  Select Solve Table to bring up the Solve Table dialog shown in Figure 1-
25.   
Figure 1-26: Solve Table dialog. 
The dialog is initially set so that EES will start with run 1 and end with run 10.  By pressing OK, 
EES will go to run 1 of the Parametric Table shown in Figure 1-24 and find that the value of the 
variable 
V_dot
is set to 200.  Therefore, you can imagine that EES places the following in the 
Equations Window. 
V_dot=100
Of course, this presents a problem because the statement: 
V_dot=100 
"volumetric flow rate, in liter per min" 
already exists in the Equations Window.  The variable 
V_dot
cannot have multiple values as it 
causes the equation set to be over-constrained (8 equations and 7 variables).  Solving the table 
will result in the error dialog shown in Figure 1-26. 
Figure 1-27: Error dialog. 
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Jpeg. Convert PDF to Png, Gif, Bitmap Images. File and Page Process. File: Merge, Append PDF Files. File: Split PDF Document. File
split pdf into multiple files; pdf merger
C# WPF PDF Viewer SDK to view, annotate, convert and print PDF in
Jpeg. Convert PDF to Png, Gif, Bitmap Images. File and Page Process. File: Merge, Append PDF Files. File: Split PDF Document. File
acrobat split pdf into multiple files; reader merge pdf
Chapter 1: Introduction to EES 
25 
This problem can be alleviated by commenting out the equation that specifies the volumetric 
flow rate in the Equations Window.  Highlight the statement, right-click, and select Comment {} 
in order to temporarily remove it from the equation set. 
{V_dot=100 
"volumetric flow rate, in liter per min"}
Now solve the table to obtain the solved Parametric Table shown in Figure 1-27.  
Figure 1-28: Solved Parametric Table. 
It will sometimes be useful to solve only a portion of the table.  This is easily accomplished by 
changing the first and last run numbers in the Solve Table dialog.   
In the Professional version of EES, the start and stop values can be set to variables.  For 
example, add the lines: 
startrow=3 
"first run" 
endrow=7 
"last run" 
Open the Parametric Table, right click on the 
DeltaP
variable column and select Alter Values.  
Select Clear Values to clear the column.  Solve the table again.  This time, click on the arrow 
next to First Run Number and change it to First Run Variable and then select 
startrow
.  Change 
Last Run Number to Last Run Variable and select 
endrow
.  The result is shown in Figure 1-28.  
Select OK and you will see that only runs 3 through 7 have been filled in. 
VB.NET PDF - WPF PDF Viewer for VB.NET Program
to Png, Gif, Bitmap Images. File & Page Process. File: Merge, Append PDF Files. File: Split PDF Document. File: Compress PDF. Page
batch pdf merger; c# merge pdf pages
VB.NET Create PDF from PowerPoint Library to convert pptx, ppt to
to Png, Gif, Bitmap Images. File & Page Process. File: Merge, Append PDF Files. File: Split PDF Document. File: Compress PDF. Page
attach pdf to mail merge; pdf mail merge
Chapter 1: Introduction to EES 
26 
Figure 1-29: Solve Table dialog with first and last runs set with variables. 
Formatting Columns 
The Parametric Table shows the value of pressure drop for each corresponding value of 
volumetric flow rate.  In Section 1.4 we will see how to use this information to prepare a plot.  
Before we do that, let's look at some other features of Parametric Tables.  The position of the 
columns can be adjusted by dragging (i.e., pressing the left mouse button and then moving 
mouse while holding down the mouse button) the column headers.  The units, alternate units, and 
format of the columns can be adjusted by right-clicking on the column and selecting Properties 
to bring up the Format Properties Table dialog shown in Figure 1-29 (for the column 
corresponding to the variable 
DELTAP
).  The format used to display the results, the background 
color, and the column width can also be adjusted.  The column number can also be set in this 
dialog.  At the bottom of the dialog, statistics are provided for the entries in the column. 
Figure 1-30: Format Properties Table dialog. 
Chapter 1: Introduction to EES 
27 
The $If, $IfNot, $Else, and $EndIf Directives 
In order to run the Parametric Table we had to comment out the line in the Equations Window 
that specified by the value of the variable 
V_dot
 This change temporarily removes the 
specification; it can be returned by highlighting the text, right clicking, and selecting Undo 
Comment {} from the pop-up menu.   
V_dot=100 
"volumetric flow rate, in liter per min" 
A more elegant method for removing one or more lines of code when a Parametric Table is being 
solved is to use the 
$If
directive.  The 
$If
directive is used according to: 
$If Condition 
line(s) of code to be executed if Condition is true 
$Else 
line(s) of code to be executed if Condition is false 
$EndIf 
where 
Condition
is a keyword that indicates an execution condition.  There are many such 
keywords recognized by EES and these are discussed in more detail in Chapter 18.  One 
keyword is 
ParametricTable
, which evaluates to true when the equations are being solved from a 
Parametric Table.  For our problem, we want to specify the value of the variable 
V_dot
in the 
Equations Window only if the value of 
ParametricTable
is false: 
$If ParametricTable 
$Else 
V_dot=100 
"volumetric flow rate, in liter per min" 
$EndIf 
Alternatively, we could use the 
$IfNot
directive according to: 
$IfNot ParametricTable 
V_dot=100 
"volumetric flow rate, in liter per min" 
$EndIf 
You should find that your equation set now runs if you select either Solve or Solve Table from 
the Calculate menu (or if you press either F2 or F3, respectively).   
Naming and Documenting Parametric Tables 
The Parametric Table can be renamed and annotated.  Right click on the tab corresponding to the 
table in order to bring up the Information for Parametric Table dialog, shown in Figure 1-30.  
Provide a descriptive name in the Title bar (DP) and record the details of the calculation in the 
Description panel.  The description can optionally be printed with the table. 
Chapter 1: Introduction to EES 
28 
Figure 1-31: Information for Parametric Table dialog. 
Saving and Loading Parametric Tables 
The Parametric Table is automatically saved with the EES program and reloaded when the 
program is reopened.  However, you can also save your Parametric Table independently by 
selecting Save in the Information for Parametric Table dialog, which is accessed by right-
clicking on the tab name for the table.  The table can be saved as a text (.txt) or comma separated 
values (.csv) file; either of these file formats can be opened by most any other software or 
spreadsheet.  The table can also be saved in a format that can be reopened by a different EES 
program as a Lookup Table (.lkt).  Lookup Tables are discussed in Section 1.8.   
Copying Information from a Parametric Table 
A range of cells from the table can be copied to a temporary memory location called the 
“clipboard” and pasted into other tables in EES or other applications, such as a word processor or 
a spreadsheet.  For example, highlight the cells between rows 3 and 7 by clicking in upper left 
cell, and the pressing and holding the Shift key down while clicking in the lower right cell.  
Next, right click to bring up the pop-up menu shown in Figure 1-31.   
Figure 1-32: Pop-up menu. 
Chapter 1: Introduction to EES 
29 
Select Copy to place the information on the clipboard.  Open another spreadsheet or word 
processor and then paste the information.  The result is shown in Figure 1-32(a) using Excel.  If 
the Copy with Headers option is selected then the header for each column is also copied; the 
result is shown in Figure 1-32(b).  Notice in both cases that the number of significant figures 
associated with the data that is copied corresponds to the number of significant figures used to 
display the information in the Parametric Table.  If the Copy (E-format) option is selected then 
the data are copied with 12 significant figures so that there is no loss of accuracy associated with 
the copy/paste operation, as shown in Figure 1-32(c). 
(a) 
(b) 
(c) 
Figure 1-33: Information pasted into Excel using (a) Copy, (b) Copy with Headers, and (c) Copy (E-format) 
commands. 
1.4  Basic Plotting 
Section 1.3 described how to create a Parametric Table that includes the value of a dependent 
variable at each of several values of an independent variable.  This information is viewed most 
conveniently in the form of a plot.  EES allows the generation of several types of plots, as 
discussed in Chapter 9.  In this section, only the most basic X-Y type plot is discussed.  Data 
contained in the Parametric Table created in Section 1.3 will be plotted in this section.  Data 
contained in Lookup Tables (see Section 1.8), Arrays (see Section 1.7), and Integral Tables (see 
Chapter 7) can also be used for this purpose.   
Generating a Plot 
To generate a plot, select New Plot Window from the Plots menu in order to access the New Plot 
Setup dialog shown in Figure 1-33.  At the top of the dialog you can provide a title (in the Tab 
Name field) and some descriptive text.  The upper right portion of the dialog is used to select the 
source of the data; here it is a Parametric Table and the title of the table is DP.  As shown in  
Figure 1-33, the New Plot dialog is set up to plot all 10 rows in the table but it is also possible to 
plot only a subset of the rows.  The two windows in the dialog allow you to specify the 
independent (X-Axis) and dependent (Y-Axis) data.  Figure 1-33 shows the New Plot dialog set 
up to plot the pressure loss as a function of the flow rate.  Select OK to create the plot, which is 
shown in Figure 1-34. 
Chapter 1: Introduction to EES 
30 
Figure 1-34: New Plot Setup dialog. 
Figure 1-35: Pressure loss as a function of flow rate. 