Live Audio Effect Reference
lowest note will have priority. The Transpose and Fine knobs allow for coarse and fine offset of 
the MIDI-modulated tuning. PB Range sets the range in semitones of pitch bend modulation.
With Frequency disabled, the Tune control adjusts the base frequency of the resonance in Hertz. 
The corresponding MIDI note number and fine tuning offset in cents is displayed below.
Enabling Off Decay causes MIDI note off messages to mute the resonance. The slider below the 
switch determines the extent to which MIDI note off messages mute the resonance. At 0%, note 
offs are ignored, and the decay time is based only on the value of the Decay parameter, which 
is located under the Resonance Type selector. This is similar to how real-world mallet instruments 
such as a marimbas and glockenspiels behave. At 100%, the resonance is muted immediately at 
note off, regardless of the Decay time.
You can hide or show the Sidechain parameters by toggling the 
button in Corpus’s title bar. 
This button will light up if the sidechain is active.
Corpus contains a Low Frequency Oscillator (LFO) to modulate the resonant frequency. The 
Amount control sets how much the LFO affects the frequency.
The Rate control specifies the LFO speed. It can be set in terms of Hertz, or synced to the song 
tempo, allowing for controlled rhythmic modulation.
Available LFO waveform shapes are sine (creates smooth modulations with rounded peaks and 
valleys), square, triangle, sawtooth up, sawtooth down and two types of noise (stepped and 
smooth).
Although only one set of LFO controls is visible, there are actually two LFOs, one for each stereo 
channel. The Phase and Spin controls define the relationship between these two LFOs.
Phase (available only when the LFOs are synced to song tempo) keeps both LFOs at the same 
frequency, but can set the two LFO waveforms ”out of phase” with each other, creating stereo 
movement. Set to ”180”, the LFO outputs are 180 degrees apart, so that when one LFO reaches 
its peak, the other is at its minimum. With Phase set to ”360” or ”0” the two LFOs run in sync.
Spin (only available when the LFOs are in Hertz mode) detunes the two LFO speeds relative to 
each other. Each stereo channel is modulated at a different frequency, as determined by the 
Spin amount.
For the noise waveforms, the Phase and Spin controls are not relevant and do not affect the 
sound.
C# merge pdf files into one - Merge, append PDF files in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provide C# Demo Codes for Merging and Appending PDF Document
split pdf into multiple files; pdf mail merge plug in
C# merge pdf files into one - VB.NET PDF File Merge Library: Merge, append PDF files in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Guide and Sample Codes to Merge PDF Documents in .NET Project
pdf merge comments; best pdf combiner
332
Live Audio Effect Reference
Spread detunes the two resonators in relation to each other. Positive values raise the pitch of the 
left resonator while lowering the pitch of the right one, while negative values do the opposite. At 
0%, the resonators are tuned the same.
The resonance type chooser allows you to select from seven types of physically modeled reso-
nant objects:
•Beam simulates the resonance properties of beams of different materials and sizes.
•Marimba, a specialized variant of the Beam model, reproduces the characteristic tuning of 
marimba bar overtones which are produced as a result of the deep arch-cut of the bars.
•String simulates the sound produced by strings of different materials and sizes.
•Membrane is a model of a rectangular membrane (such as a drum head) with a variable 
size and construction.
•Plate simulates sound production by a rectangular plate (a flat surface) of different materi-
als and sizes.
•Pipe simulates a cylindrical tube that is fully open at one end and has a variable opening 
at the other (adjusted with the Opening parameter.)
•Tube simulates a cylindrical tube that is fully open at both ends.
The resonator quality chooser controls the tradeoff between the sound quality of the resonators 
and performance by reducing the number of overtones that are calculated. ”Basic” uses minimal 
CPU resources, while ”Full” creates more sophisticated resonances. This parameter is not used 
with the Pipe or Tube resonators.
The Decay knob adjusts the amount of internal damping in the resonator, and thus the decay 
time.
The Material knob adjusts the variation of the damping at different frequencies. At lower values, 
low frequency components decay slower than high frequency components (which simulates 
objects made of wood, nylon or rubber). At higher values, high frequency components decay 
slower (which simulates objects made of glass or metal). This parameter is not used with the Pipe 
or Tube resonators.
Online Merge PDF files. Best free online merge PDF tool.
We try to make it as easy as possible to merge your PDF files. RasterEdge C#.NET PDF document merging toolkit (XDoc.PDF) is designed to help .NET
pdf combine; c# merge pdf files
C# Word - Merge Word Documents in C#.NET
Combine and Merge Multiple Word Files into One Using C#. This part illustrates how to combine three Word files into a new file in C# application.
apple merge pdf; reader create pdf multiple files
333
Live Audio Effect Reference
The Radius parameter is only available for the Pipe and Tube resonators. Radius adjusts the ra-
dius of the pipe or tube. As the radius increases, the decay time and high frequency sustain both 
increase. At very large sizes, the fundamental pitch of the resonator also changes.
The Decay and Material/Radius parameters can also be controlled with the X-Y controller.
Ratio is only available for the Membrane and Plate resonators, and adjusts the ratio of the ob-
ject’s size along its x and y axes.
The Brightness control adjusts the amplitude of various frequency components. At higher values, 
higher frequencies are louder. This parameter is not used with the Pipe or Tube resonators.
Inharm. (Inharmonics) adjusts the pitch of the resonator’s harmonics. At negative values, fre-
quencies are compressed, increasing the amount of lower partials. At positive values, frequen-
cies are stretched, increasing the amount of upper partials. This parameter is not used with the 
Pipe or Tube resonators.
Opening, which is only available for the Pipe resonator, scales between an open and closed 
pipe. At 0%, the pipe is fully closed on one side, while at 100% the pipe is open at both ends.
The Listening L and R controls adjust the location on the left and right resonator where the vibra-
tions are measured. At 0%, the resonance is monitored at the object’s center. Higher values 
move the listening point closer to the edge. These parameters are not used with the Pipe or Tube 
resonators, which are always measured in the middle of their permanently open end.
The Hit knob adjusts the location on the resonator at which the object is struck or otherwise ac-
tivated. At 0%, the object is hit at its center. Higher values move the activation point closer to the 
edge. This parameter is not used with the Pipe or Tube resonators.
The processed signal is fed through a lowpass and highpass filter that can be controlled with an 
X-Y controller. To define the filter bandwidth, click and drag on the vertical axis. To set the posi-
tion of the frequency band, click and drag on the horizontal axis. The filter can be toggled on or 
off with the Filter switch.
Width adjusts the stereo mix between the left and right resonators. At 0%, both resonators are 
fed equally to each side, resulting in mono output. At 100%, each resonator is sent exclusively to 
one channel.
Bleed mixes a portion of the unprocessed signal with the resonated signal. At higher values, 
more of the original signal is applied. This is useful for restoring high frequencies, which can 
C# PowerPoint - Merge PowerPoint Documents in C#.NET
Combine and Merge Multiple PowerPoint Files into One Using C#. This part illustrates how to combine three PowerPoint files into a new file in C# application.
break a pdf into multiple files; pdf merge
C# Create PDF from images Library to convert Jpeg, png images to
Example: Convert More than Two Type Images to PDF in C#.NET Application. This example shows how to build a PDF document with three image files (BMP, JPEG
combine pdf files; attach pdf to mail merge
334
Live Audio Effect Reference
often be damped when the tuning or quality are set to low values. This parameter is unavailable 
with the Pipe or Tube resonators.
Gain boosts or attenuates the level of the processed signal, while the Dry/Wet control adjusts 
the balance between the dry input signal and the signal sent to Corpus’s processing. Turning 
Dry/Wet down will not cut resonances that are currently sounding, but rather stop new input 
signals from being processed.
Corpus contains a built-in limiter that automatically activates when the audio level is too high. 
This is indicated by the LED in the upper-right corner of Corpus’s display.
22.9 Dynamic Tube
The Dynamic Tube Effect.
(Note: the Dynamic Tube effect is not available in the Intro and Lite Editions.)
The Dynamic Tube effect infuses sounds with the peculiarities of tube saturation. An integrated 
envelope follower generates dynamic tonal variations related to the level of the input signal.
Three tube models, A, B and C, provide a range of distortion characteristics known from real 
amplifier tubes. Tube A does not produce distortions if Bias is set low, but will kick in whenever 
the input signal exceeds a certain threshold, creating bright harmonics. Tube C is a very poor 
tube amp that produces distortions all the time. The qualities of Tube B lie somewhere between 
these two extremes.
C# PDF: C# Code to Process PDF Document Page Using C#.NET PDF
C# PDF Page Processing: Merge PDF Files - C#.NET PDF document merger APIs for combining two different PDF documents into one large PDF file.
c# combine pdf; add pdf together
C# Create PDF from CSV to convert csv files to PDF in C#.net, ASP.
document, it's unnecessary to convert CSV files to .xls This C# sample code illustrates how to convert CSV to Description: Convert to PDF/TIFF and save it into
break pdf file into multiple files; acrobat combine pdf
335
Live Audio Effect Reference
The Tone control sets the spectral distribution of the distortions, directing them into the higher 
registers, or through the midrange and deeper.
The Drive control determines how much signal reaches the tube; greater Drive yields a dirtier 
output. The intensity of the tube is controlled by the Bias dial, which pushes the signal into the 
celebrated realms of nonlinear distortion. With very high amounts of Bias, the signal will really 
start to break apart.
The Bias parameter can be positively or negatively modulated by an envelope follower, which is 
controlled with the Envelope knob. The more deeply the envelope is applied, the more the Bias 
point will be influenced by the level of the input signal. Negative Envelope values create expan-
sion effects by reducing distortion on loud signals, while positive values will make loud sounds 
dirtier.
Attack and Release are envelope characteristics that define how quickly the envelope reacts to 
volume changes in the input signal. Together, they shape the dynamic nature of the distortions. 
Note that if Envelope is set to zero, they will have no effect.
Cut or boost the device’s final signal level with the Output dial.
Aliasing can be reduced by enabling Hi-Quality mode, which can be accessed via the [right-
click](PC) / [CTRL-click](Mac) context menu. This improves the sound quality, particularly with 
high frequency signals, but there is a slight increase in CPU usage.
22.10 EQ Eight
The EQ Eight Effect.
C# PDF: C#.NET PDF Document Merging & Splitting Control SDK
C#. VB.NET. Home > .NET Imaging SDK > C# > Merge and Split C# PDF Merging & Splitting Application. This C#.NET PDF to one PDF file and split source PDF file into
add two pdf files together; combine pdf online
VB.NET TWAIN: Scanning Multiple Pages into PDF & TIFF File Using
most cases, those scanned individual image files need to New PDFDocument(imgSouce) doc1.Save("outputPDF.pdf") End Sub Written in managed C# code, this VB.NET
pdf merge files; reader combine pdf pages
336
Live Audio Effect Reference
(Note: the EQ Eight effect is not available in the Intro and Lite Editions.)
The EQ Eight effect is an equalizer featuring up to eight parametric filters per input channel, use-
ful for changing a sound’s timbre.
The input signal can be processed using one of three modes: Stereo, L/R and M/S. Stereo 
mode uses a single curve to filter both channels of a stereo input equally. L/R mode provides an 
independently adjustable filter curve for the left and right channels of a stereo input; M/S mode 
(Mid/Side) provides the same functionality for signals that have been recorded using M/S en-
coding. In all modes, the frequency spectrum of the output is displayed behind the filter curves 
when the Analyze switch is on.
When using the L/R and M/S modes, both curves are displayed simultaneously for reference, 
although only the active channel is editable. The Edit switch indicates the active channel, and is 
used to toggle between the two curves.
Each filter has a chooser that allows you to switch between eight responses. From top to bottom 
in the choosers, these are:
•48 or 12 dB/octave Low cut (cuts frequencies below the specified frequency);
•Low shelf (boosts or cuts frequencies lower than the specified frequency);
•Bell curve (boosts or cuts over a range of frequencies);
•Notch (sharply cuts frequencies within a narrow range);
•High shelf (boosts or cuts frequencies higher than the specified frequency);
•12 or 48 dB/octave High cut (cuts frequencies above the specified frequency).
Each filter band can be turned on or off independently with an activator switch below the 
chooser. Turn off bands that are not in use to save CPU power. To achieve really drastic filtering 
effects, assign the same parameters to two or more filters.
To edit the filter curve, click and drag on the filter dots in the display. Drag-enclose multiple filter 
dots to adjust them simultaneously, either with the mouse or with your computer keyboard’s ar-
row keys. Horizontal movement changes the filter frequency, while vertical movement adjusts 
the filter band’s gain. To adjust the filter Q (also called resonance or bandwidth), hold down 
the [ALT](PC) / [ALT](Mac) modifier while dragging the mouse. Note that the gain cannot be 
337
Live Audio Effect Reference
adjusted for the low cut, notch and high cut filters. In these modes, vertical dragging adjusts the 
filter Q.
To get an even better view, you can toggle the location of the display between the device chain 
and Live’s main window by clicking the 
button in EQ Eight’s title bar. When using this expand-
ed view, all eight filters can be edited simultaneously in the Device View.
EQ Eight’s Controls With the Display Expanded.
By default, EQ Eight’s output spectrum is shown in the display. If you would prefer to work en-
tirely “by ear,” you can turn off the Analyze button to disable the spectrum view.
With Adaptive Q enabled, the Q amount increases as the amount of boost or cut increases. This 
results in a more consistent output volume and is based on the behavior of classic analog EQs.
To temporarily solo a single filter, enable Audition mode via the headphone icon. In Audition 
mode, clicking and holding on a filter dot allows you to hear only that filter’s effect on the output.
You can also select a band for editing by clicking near its number and then edit parameter val-
ues with the Freq, Gain and Q dials (and/or type values into the number fields below each dial).
As boosting will increase levels and cutting will decrease levels, use the global Gain slider to 
optimize the output level for maximum level consistent with minimum distortion.
The Scale field will adjust the gain of all filters that support gain (all except low cut, notch and 
high cut).
338
Live Audio Effect Reference
Context Menu Options
Several of EQ Eight’s controls are only available via the [right-click](PC) / [CTRL-click](Mac) 
context menu. These include:
•Oversampling - enabling this option causes EQ Eight to internally process two times the 
current sample rate, which allows for smoother filter behavior when adjusting high fre-
quencies. There is a slight increase in CPU usage with Oversampling enabled.
•Shelf Scaling Legacy Mode - As of Live 9, the shape of EQ Eight’s shelf filters has been 
improved. Live Sets that use EQ Eight and which were made prior to Live 9 may sound 
slightly different. To ensure that older Sets sound exactly the same, the Shelf Scaling Leg-
acy Mode option will be enabled by default when loading an old Set that uses EQ Eight. 
You can disable this via a [right-click](PC) / [CTRL-click](Mac) context menu entry in EQ 
Eight’s title bar.
Note: as of Live 9, the “Hi-Quality” [right-click](PC) / [CTRL-click](Mac) context menu option 
has been removed. EQ Eight now always operates in this mode.
22.11 EQ Three
The EQ Three Effect.
If you have ever used a good DJ mixer you will know what this is: An EQ that allows you to ad-
just the level of low, mid and high frequencies independently.
339
Live Audio Effect Reference
Each band can be adjusted from -infinite dB to +6 dB using the gain controls. This means that 
you can completely remove, for example, the bass drum or bassline of a track, while leaving the 
other frequencies untouched.
You can also turn on or off each band using the On/Off buttons located under the gain controls. 
These buttons are especially handy if assigned to computer keys.
EQ Three gives you visual confirmation of the presence of a signal in each frequency band using 
three LEDs. Even if a band is turned off, you can tell if there is something going on in it. The inter-
nal threshold for the LEDs is set to -24 dB.
The frequency range of each band is defined via two crossover controls: FreqLo and FreqHi. If 
FreqLo is set to 500 Hz and FreqHi to 2000 Hz, then the low band goes from 0 Hz to 500 Hz, 
the mid band from 500 Hz to 2000 Hz and the high band from 2000 Hz up to whatever your 
soundcard or sample rate supports.
A very important control is the 24 dB/48 dB switch. It defines how sharp the filters are cutting 
the signal at the crossover frequency. The higher setting results in more drastic filtering, but needs 
more CPU.
Note: The filters in this device are optimized to sound more like a good, powerful analog filter 
cascade than a clean digital filter. The 48 dB Mode especially does not provide a perfect linear 
transfer quality, resulting in a slight coloration of the input signal even if all controls are set to 
0.00 dB. This is typical behavior for this kind of filter, and is part of EQ Three’s unique sound. If 
you need a more linear behavior choose 24 dB Mode or use the EQ Eight.
340
Live Audio Effect Reference
22.12 Erosion
The Erosion Effect.
The Erosion effect degrades the input signal by modulating a short delay with filtered noise or 
a sine wave. This adds noisy artifacts or aliasing/downsampling-like distortions that sound very 
”digital.”
To change the sine wave frequency or noise band center frequency, click and drag along the 
X-axis in the X-Y field. The Y-axis controls the modulation amount. If you hold down the [ALT](PC) 
/ [ALT](Mac) modifier key while clicking in the X-Y field, the Y-axis controls the bandwidth. Note 
that bandwidth is not adjustable when Sine is selected.
The Frequency control determines the color, or quality, of the distortion. If the Mode control is set 
to Noise, this works in conjunction with the Width control, which defines the noise bandwidth. 
Lower values lead to more selective distortion frequencies, while higher values affect the entire 
input signal. Width has no effect in Sine Mode.
Noise and Sine use a single modulation generator. However, Wide Noise has independent 
noise generators for the left and right channels, which creates a subtle stereo enhancement.