13.2.7.2 Kilowatt-Hour Price 
The price per kilowatt-hour for each tariff period - high tariff (HT), low tariff (LT) and any 
special tariff (ST) - is defined in this dialog. In order to be able to define the tariffs for 
special periods, these have to be entered under Tariff Time Periods. 
Inflation: 
The rates that need to be entered into the table are basic prices that produce the kilowatt-
hour rate when multiplied by the Inflation. With the Inflation the grid utility company takes 
the current energy price and eg. wage increases into account. Normally, only the basic 
price level is used in the low voltage range, so that the Inflation is 1 in this case. 
Summer/Winter Different: 
Different kilowatt-hour rates can be entered for summer and winter times. In this case the 
prices are not valid for the whole year’s energy consumption, but for summer and winter 
periods. If at the same time Different Pricing Bands for Each Tariff Period is selected you 
can separate out the kilowatt-hour rates for summer and winter periods into high and low 
tariffs. 
Staggered Consumption Regulation: 
If this selection is made the valid kilowatt-hour price is given as follows: 
• 
With a total annual consumption during HT periods of 600,000 kWh, for example, 
the price band starting from a consumption level larger than 500,000 kWh is valid, 
for the total energy produced during the HT period HT energy the basic price of 0.35 
€/kWh is valid. 
Consumption Zone Regulation: 
On making this selection the text of the first column changes in order to make the prices 
given clearer. ”Consumption larger than” becomes ”Each further kWh from”. The valid 
kilowatt-hour rate is given as follows: 
• 
With a total annual consumption during HT periods of 600,000 kWh, for example, a 
basic price of 0.36 €/kWh for the first 250,000 kWh is valid, for the second 
250,000 kWh the basic price of 0.35 €/kWh is valid and for the final 100,000 kWh a 
basic price of 0.33 €/kWh is valid. 
The total HT kilowatt-hour rate is therefore calculated as follows: 
Total HT kilowatt-hour rate : (250.000 kWh * 0.36 €/kWh + 250.000 kWh * 0.35 €/kWh + 
100.000 kWh * 0.33 €/kWh) * Inflation 
Different Pricing Bands for Each Tariff Time Period: 
Break pdf file into multiple files - Merge, append PDF files in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provide C# Demo Codes for Merging and Appending PDF Document
asp.net merge pdf files; acrobat split pdf into multiple files
Break pdf file into multiple files - VB.NET PDF File Merge Library: Merge, append PDF files in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Guide and Sample Codes to Merge PDF Documents in .NET Project
apple merge pdf; batch merge pdf
PV*SOL Expert 6.0  -  Manual  
180 
On making this selection the kilowatt-hour rate for each tariff period is given its own 
worksheet. In this case the valid pricing band is no longer given as the total annual 
consumption, but as the total consumption in the time period that is valid for each 
worksheet. If, for example, Summer/Winter Different is not selected, then the valid 
kilowatt-hour rate for the winter HT is only given in the total consumption for summer and 
winter HT. 
-> See also: 
From Grid Tariff
C# PDF File Split Library: Split, seperate PDF into multiple files
SharePoint. C#.NET control for splitting PDF file into two or multiple files online. Support to break a large PDF file into smaller files.
reader create pdf multiple files; acrobat reader merge pdf files
VB.NET PDF File Split Library: Split, seperate PDF into multiple
Split PDF file into two or multiple files in ASP.NET webpage online. Support to break a large PDF file into smaller files in .NET WinForms.
reader merge pdf; append pdf files reader
181 
13.2.7.3 Power Measurement 
The basic specifications for power measurement are entered in this dialog. Further 
specifications can be made depending on the type of power measurement selected. The 
following power measurement categories are available: 
Type of Power Measurement 
• 
No Power Measurement 
• 
96 Hour Measurement 
• 
Standard Calculation (¼ hour power measurement) 
• 
Light/Heavy Load Maximums 
No Power Measurement 
If the tariff for energy supply from the grid suffices without power measurement, then you 
should select ”No Power Measurement”. 
96 Hour Measurement 
With the 96 hour tariff the electricity consumption in kWh within 96 consecutive hours is 
added together in a consecutive time window. These hourly values are called power 
values (Pow. Val.). The highest power value within the time period measured is used for 
the calculation of power payment. The power payment is the sum of the highest power 
value multiplied by the valid load price for annual electricity consumption according to 
the given pricing band. 
During 96 hour measurement with time zone regulation, the recording of the power 
values during low tariff is suspended without changing the consecutive timing for the 96 
hour measurement periods. In this case Measurement Only During HT Periods must be 
selected in the Load Price dialog 
Standard Calculation (¼ hour power measurement) 
This calculates the power from the average value of the highest monthly power output 
figures. The number of months that are used to calculate the maximum annual power 
output is entered in the Load Price dialog. 
Light/Heavy Load Maximums 
¼ hour power measurement, with the time period used for providing the billing load 
being limited to the so called heavy load periods. These heavy load periods are entered 
in the Heavy Load Periods dialog. Further definition of the heavy load peak is described 
under Standard Calculation. 
The lowest monthly light load is entered separately. 
C# PDF Page Insert Library: insert pages into PDF file in C#.net
Offer PDF page break inserting function. a new PDF page into existing PDF document file, RasterEdge C# .NET functions, such as how to merge PDF document files
add pdf files together online; pdf merge files
VB.NET PDF Page Insert Library: insert pages into PDF file in vb.
Offer PDF page break inserting function. you go to C# Imaging - how to insert a new empty page to PDF file DLLs for Adding Page into PDF Document in VB.NET Class.
acrobat merge pdf files; c# merge pdf files into one
PV*SOL Expert 6.0  -  Manual  
182 
Output peaks during low output periods are only considered if the monthly low output 
peak reaches a level above the given annual peak power output at peak load times. The 
monthly differences of these values are sorted according to size and an average value is 
calculated. The resulting difference is only partly used in the calculation, the factor is 
entered in the Load Price dialog. The number of months used for producing a figure for 
the light load peak is also entered in the Load Price dialog. The sum of the heavy load 
maximum and the allowed for light load share gives a figure for the calculated power. 
Set Load Price: 
The electricity payment is made up of two parts: a set price and a price dependent on 
consumption. The set load price must always be paid separately from the price for grid 
power actually used. 
Hourly Peaks in the Defined Load Plus: 
(only for Standard Calculation and Heavy/Light Load Maximums) 
Depending on the grid utility company, monthly power outputs are measured in ¼ or ½ 
hour averages. The highest output during the year is multiplied with the given specific 
load price, in order to give a figure for the annual load price that will have to be paid. In 
the programme the highest monthly output figure is the highest occurring average 
hourly output in each month (to account for the time stages). This leads to lower output 
peaks because the ¼ hour variations are levelled out. In order to correct this the 
highest monthly outputs for calculating the highest annual output are multiplied by the 
¼ hour peaks in the defined loads plus. Depending on the type of appliance, the size of 
the area supplied, and any measured loads to hand, a percentage figure between 0% 
and 50% must be entered here. For typical housing estates with an annual consumption 
of more than 100,000 kWh, an annual consumption of 5-10% can be used for the 
calculation. 
Minimum Power Output: 
(only for Standard Calculation and Heavy/Light Load Maximums) 
This measure is only used in the calculation if the maximum output is less than this value. 
Wholesale Provision: 
(only for Standard Calculation and Heavy/Light Load Maximums) 
Instead of a set load price, a price for wholesale provision can be requested. This is paid if 
the hours of full use (HFU) do not reach the set threshold value. The wholesale provision 
price (WPP) is calculated as follows: 
WPP = price [€/kW] * max. power output 
* (1 HFU/hours of minimum use) 
Max. power output
: the maximum power output calculated by the programme, or possibly 
the minimum output. 
HFU
Hours of full use = total annual kWh output/maximum output 
Power Measurement 
183 
-> See also: 
Results > From Grid Electricity Costs 
184 
13.2.7.3.1 Load Price 
This dialog is used to define the demand price for the electricity tariff. Different entry fields 
are activated depending on what form of power measurement is selected, so that 
additional specifications can be entered. 
Number of Maximums Allowed For 
(only for Standard Calculation and Heavy/Light Load Maximums in the Power 
Measurement dialog) 
Heavy Load: 
The number of monthly maximums is entered here. The heavy load peak is calculated from 
the average of these monthly maximums. With the standard calculation the heavy load 
peak corresponds to the billing load. 
Light Load: 
(only for Heavy/Light Load Maximums in the Power Measurement dialog) 
With power measurement using Heavy/Light Load Maximums, light load maximums are 
considered under certain conditions. Here the number of monthly maximums is entered, 
from which the light load peak is calculated. 
Include Light Load Maximums: 
(only for Heavy/Light Load Maximums in the Power Measurement dialog) 
This factor describes which percentage of light load additional output is included in the 
billing load calculation. 
Inflation: 
The prices to be entered in this table are base prices that, multiplied with the Inflation, 
give the load price per KW. With the Inflation the grid utility company takes the current 
energy price and eg. wage increases into account. Normally, only the basic price level is 
used in the low voltage range, so that in this case the Inflation is 1. 
Pricing by Total kWh: 
Instead of giving price bands or price zones for the load price via the billing load, in this 
case the load price is given by annual electricity consumption in kWh. 
Staggered Consumption Regulation: see Kilowatt-Hour Price 
Consumption Zone Regulation: see Kilowatt-Hour Price 
Measurement Only During HT Periods: (only for 96 hour measurement in the Power 
Measurement dialog) 
Corresponds to 96 hour measurement with time zone regulation. Here the output values 
during low tariff periods are not included, without changing the 96 hour measurement 
periods’ progressive intervals. 
Load Price 
185 
-> See also: 
From Grid Tariff
186 
13.2.7.3.2 Heavy Load Periods 
The heavy load periods for the grid are defined in this dialog. 
Heavy Load Periods - Summer/Winter Different: 
If you click on this button you are able to enter all the heavy load periods separately for 
summer and winter. 
Heavy Load Periods – From… To: 
If the heavy load periods for summer and winter are different, this is where you define the 
beginning and end of winter time for the heavy load periods. Entry of heavy load periods is 
made in date format dd.mm. . 
New Heavy Load Periods Valid From: 
With the assistance of this field you are able to define the days in the week that heavy load 
periods are valid on. The days of the week are given in the first column, so that it is clear 
for which day the time entered is valid. 
Heavy Load Periods: 
You are able to enter up to 5 time periods (from hour to hour) for each day of the week. 
Entry is made in time format. 
-> See also: 
From Grid Tariff
187 
13.2.7.4 Discounts/Supplements 
You can enter Discounts and Supplements from the electricity utility separately on the two 
pages provided. 
-> See also: 
From Grid Tariff
188 
13.2.7.4.1 Discounts 
General Discount: 
Here you can enter rebates/discounts that are guaranteed regardless of consumption, eg a 
discount for electricity drawn at the 30 kV voltage level. 
Load Utilisation Period Discount: 
(only for Standard Calculation and Heavy/Light Load Maximums in the Power 
Measurement dialog) 
The load utilisation period is the relationship of total annual energy drawn from the grid to 
the billing load, and is a measurement of the regularity of energy use. With some tariffs or 
special deals the electricity company gives the customer a discount from a point over a 
certain minimum load utilisation period. This discount is, as a rule, included in the total 
kilowatt-hour and load tariff payments. In the case that the discount is only observed for 
HT energy and the load price, it is referred to as the HT utilisation period rebate. 
Minimum Load Utilisation Period: 
A discount is first included in the calculation when the load utilisation period is above this 
figure. If the usage is below this figure, an additional charge does not have to be made in 
compensation. 
Load Utilisation Period Discount Valid for: 
Here you can select the payment categories for which the load utilisation period discount 
are valid for. 
Load Utilisation Period Discount by Formula: 
If this option is selected the load utilisation period discount is calculated using the 
following formula: 
if the load utilisation period – minimum load utilisation period > 0 load utilisation 
period discount = Factor X * (load utilisation period – minimum load utilisation 
period) 
Load Utilisation Period: 
The relationship of total annual energy drawn from the grid to the billing load. 
If the calculated load utilisation period discount exceeds the maximum load utilisation 
period discount, this figure (ie the greater) is observed. 
Load Utilisation Period Discount by Table: 
Instead of a linear climbing load utilisation period discount, it is also possible to account 
for price bands in a table. The discount table values can be entered in the Load Utilisation 
Period Discount dialog. Here it is also the case that a load utilisation period discount is 
first observed when the minimum load utilisation period is reached. 
-