adobe pdf viewer c# : C# combine pdf control SDK system web page wpf windows console manual-pvsol-en6-part883

59 
9.4.1 
Individual Appliances: User-Independent Appliance 
P
age 
Consumption > Individual Appliances:  Selection
Definition of Electrical Appliances by 
Individual Appliances >  Individual Appliances
A user-independent appliance is not normally switched on and off by the user, but runs 
automatically for long periods of time – e.g. refrigerator, deep-freeze. 
Stand-by: an entry is not possible in the case of an appliance in constant use. 
Annual Energy Requirement: the annual energy requirement should be given for general 
operation over the whole year. 
Operating Times: 
Appliance in Constant Use: the appliance is generally switched on the whole time. 
Switch on Every…: sets the switching-on interval. Define the appliance by the intervals 
it remains switched on. 
C# combine pdf - Merge, append PDF files in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Provide C# Demo Codes for Merging and Appending PDF Document
add pdf together one file; merge pdf
C# combine pdf - VB.NET PDF File Merge Library: Merge, append PDF files in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET Guide and Sample Codes to Merge PDF Documents in .NET Project
append pdf files reader; append pdf
60 
9.4.2 
Individual Appliances: User-Dependent Appliance 
P
age 
Consumption > Individual Appliances:  Selection
Definition of Electrical Appliances by 
Individual Appliances >  Individual Appliances
A user-dependent appliance is used regularly and at certain times, eg TV, computer. 
Stand-by: an entry here is only made for appliances with this facility where stand-by is 
always active when the appliance is not in operation. 
Operating Times: 
Clock: the hours of operation are set by clicking on the fields (green field = in operation, 
white field = not in operation). 
All days the same
: if the tick is removed, it is possible to enter different operating times 
for all the days of the week. 
No Other Restriction: the operating times are as defined by the clock. 
Nights Only
: the operating hours are only valid if, at the same time, global radiation 
equals zero. . 
Days Only
: the operating hours are only valid if, at the same time, global radiation is 
greater than zero. 
in use
: click on month or 
day (green) 
out of service
: click on month or 
day (white) 
in use
: click on hour field (green) 
out of service
: click on hour field (white) 
C# PDF: C#.NET PDF Document Merging & Splitting Control SDK
C#.NET PDF Merger to Combine PDF Files. Using following C#.NET PDF document merging APIs, you can easily merge two or more independent PDF files to create a
pdf merge documents; c# pdf merge
C# PDF File Split Library: Split, seperate PDF into multiple files
using which C# developers can split target PDF document file by specifying a page or pages. If needed, developers can also combine generated split PDF document
add pdf files together online; all jpg to one pdf converter
61 
9.4.3 
Individual Appliance: Light 
P
age 
Consumption > Individual Appliances:  Selection
Definition of Electrical Appliances by 
Individual Appliances >  Individual Appliances
An appliance is defined as a light when it is switched on depending on the amount of 
daylight. 
Output: Electricity requirement in [kWh] 
Stand-by Input: an entry here is only made for appliances with this facility where stand-by 
is always active when the appliance is not in operation. 
Operating Times: 
All days the same
: if the tick is removed, it is possible to enter different operating times 
for all the days of the week. 
Clock: The hours of operation are set by clicking on the fields (green field = in operation, 
white field = not in operation). The appliance can only operate within the defined 
operating hours. 
No Other Restriction
: the operating times are as defined by the clock. 
Full Darkness
: the operating hours are only valid if, at the same time, global radiation 
equals zero. . 
Dusk
: the operating hours are only valid if, at the same time, global radiation is less than 
20 W/m². 
Dull Weather
: the operating hours are only valid if, at the same time, global radiation is 
less than 50 W/m². 
C# Word - Merge Word Documents in C#.NET
Combine and Merge Multiple Word Files into One Using C#. This part illustrates how to combine three Word files into a new file in C# application.
split pdf into multiple files; .net merge pdf files
Online Merge PDF files. Best free online merge PDF tool.
RasterEdge C#.NET PDF document merging toolkit (XDoc.PDF) is designed to help .NET developers combine PDF document files created by different users to one PDF
reader merge pdf; batch pdf merger online
62 
9.4.4 
Individual Appliances: Short-Time Use Appliance 
Page 
Consumption > Individual Appliances:  Selection
Definition of Electrical Appliances by 
Individual Appliances >  Individual Appliances
A short-time use appliance is a user-dependent appliance that is generally switched on for 
less than an hour each time it is used, e.g. iron, coffee maker. 
Output: Electricity requirement in [kWh] per use 
Stand-by Input: an entry here is only made for appliances with this facility where stand-by 
is always active when the appliance is not in operation. 
Operating Times – per use: 
• 
Enter the period of use or 
• 
enter the electricity requirement per use 
Hourly Use: 
• 
Enter the number of uses per hour for each hours of the day in the bar. 
• 
If the tick is removed at 
All Days the Same
, it is possible to enter hourly use 
separately for each day of the week. 
C# PowerPoint - Merge PowerPoint Documents in C#.NET
Combine and Merge Multiple PowerPoint Files into One Using C#. This part illustrates how to combine three PowerPoint files into a new file in C# application.
combine pdfs online; adding pdf pages together
VB.NET PDF: Use VB.NET Code to Merge and Split PDF Documents
Please get the latest XDoc.PDF C# Developer Guide here. destn As [String]) Implements PDFDocument.Combine End Sub. APIs for Splitting PDF document in VB Class.
merge pdf online; pdf combine two pages into one
63 
10 System Menu 
-> Precondition: Planning a 2D system 
Technical Data 
Shade 
VB.NET TIFF: Merge and Split TIFF Documents with RasterEdge .NET
get the latest XDoc.Tiff C# Developer Guide here docList As [String]()) TIFFDocument.Combine(filePath, docList & profession imaging controls, PDF document,
merge pdf; acrobat combine pdf files
C# PowerPoint: C# Codes to Combine & Split PowerPoint Documents
dirs) { docList.Add(doc); } PPTXDocument.Combine(docList, combinedPath Following demo code in C# is offered to & profession imaging controls, PDF document, tiff
best pdf merger; batch pdf merger
64 
10.1 Technical Data 
System > Technical Data 
3D: PV*SOL Expertopens the 3D Visualization. There you define the terrain, 
buildings or slopes, cover roofs, mount modules and wire them by using 3D objects. The 
3D Visualization has its own help. 
2D: The technical data for the system configuration are entered in this dialog, which 
is made up of a number of worksheets. 
-> Preconditions:  
1. 
Planning a 2D system
2. The sheets used vary according to the system type (grid connected or stand-alone). 
-> Proceed as follows: 
1. On the first page ”
System
”, you need to select whether the system uses an 
inverter system
or 
multiple inverters
2. Enter the 
number of Arrays
for both types of system. 
You can enter up to a maximum of six arrays. 
A corresponding number of pages then appear on the bottom of the dialog, so that 
you can define the parameters for each array separately.  
With a single array the page is labelled ”
Array
”. A number of arrays are labelled: 
Array 1
”, ”
Array 2
” etc. 
3. The other pages of the dialog vary depending on the selected system: Grid 
Connected or Stand-Alone. 
About the buttons located on the right hand side of the dialog: 
4. Losses 
5. System Check 
6. Click on 
System Diagram
for displaying a system sketch. This sketch also forms 
part of the Summary Report. 
7. Following a positive system check, you can start the Simulation. 
8. Close the dialog with 
OK
65 
10.1.1 PV Array/Sub-Array 
System > Technical Data > PV Array/ Array i
An array is understood as a PV area with the same module types, the same orientation and 
installation type, and as applicable the same inverters. 
66 
10.1.2 Technical data, stand-alone system (PV*SOL Expert only) 
System > Technical data
10.1.2.1 Tab System 
PV array operation 
Select the operating mode of the stand-alone system:  
• 
MPP tracking
• 
Direct battery coupling
No. of MPP trackers  
With a PV array with MPP tracking, you must define whether  
• 
one common 
System MPP tracker
or  
• 
one 
Per array
is used. 
Appliances 
• 
Select either 
DC
or  
• 
AC consumptions
For AC consumptions, you must include a stand-alone inverter; the tab 
Stand-alone 
inverter
therefore appears at the bottom edge of the window.  
Other tabs for stand-alone systems 
PV array, array 
Stand-alone inverter 
Battery 
Charge controller 
Back-up generator 
-> Buttons in the right-hand area: 
• 
Click on 
Losses to 
check the influence of losses in the DC cabling. 
• 
To check the configuration of modules and inverters, click on the 
Check
button. 
• 
System diagram
shows the print preview of the system schematic also included in 
the summary report. Each array is summarized as a PV symbol and an inverter 
symbol. 
• 
Following a positive 
Check
of the system, you can start the Simulation. 
-> See also: 
Technical data, stand-alone 
67 
Technical data, grid connected 
68 
10.1.2.2 PV array, stand-alone 
System > Technical data > PV array
Stand-alone PV arrays require some different data to grid connected ones. 
-> How to proceed: 
1. Give the array a 
Name
2. Select a 
PV module
If your desired module is not available, you must first enter it in the 
PV module
database. 
Leave the 
Load file
dialog by clicking 
OK
. The parameters are taken over into the current 
project. 
The complete data record of the selected modules appears in an information window if the 
cursor is held over the 
PV modules
button. 
3. As required, select the option 
Create preview of roof layout with Photo Plan
.  
4. Enter the 
Installation type
: free, with rear ventilation or without rear ventilation.  
5. 
Array output
- Specify the number of modules: Enter the 
Number of modules
 
- Determine output from roof area: The Minimum distance of the rows of modules 
are calculated in the 
Roof parameters
dialog in order to minimize mutual shading 
and thus determine the number of modules from the available roof area. 
The resulting output of the array is calculated from the number of modules. 
6. 
Orientation
With the help of the 
Orientation
, the irradiation onto the horizontal surface is 
converted into irradiation to the inclined PV area. 
For stand-alone systems only: 
The DC cabling to the charge controller is the cabling from the string distributor of the PV 
modules to the charge controller. Standard Cable cross sections are available in the 
selection drop-down box; it is possible to enter other cross sections. 
The cabling losses in the cables of the individual modules to the string distributor can be 
generally taken into account in the "Calculation model and losses" dialog. 
If several cables run in parallel to the charge controller, please add together the cable 
cross sections of the individual cables. 
Documents you may be interested