asp net mvc show pdf in div : C# split pdf software application project winforms html web page UWP p25_training_guide3-part1329

TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
27
Training
Guide
Network Access Code (NAC)
The NID contains the 12 bit NAC fi eld.  NAC codes are user 
programmable and are typically used to control network access but 
may also be used to steer repeater functions .  NAC codes are used 
the same way as an analog CTCSS tone (or DCS code).  NAC codes 
minimize co-channel interference and allow repeater addressing by 
keeping the receiver squelched unless a signal with a matching NAC 
arrives.
The NAC code’s 12-bit fi eld ranges from hexadecimal $000 to $FFF 
and contains 4096 addresses (signifi cantly more than the standard 
CTCSS and DCS tones).
The following NAC codes have specifi c functions:
$293  specifi ed as the default NAC value.
$F7E a receiver set for NAC $F7E will unsquelch on any incoming 
NAC.
$F7F a repeater receiver set for NAC $F7F will allow all incoming 
signals to be repeated with the NAC intact.
(See Chapter 4; Figure 4-3)
C# split pdf - Split, seperate PDF into multiple files in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Explain How to Split PDF Document in Visual C#.NET Application
break apart a pdf; break a pdf into smaller files
C# split pdf - VB.NET PDF File Split Library: Split, seperate PDF into multiple files in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET PDF Document Splitter Control to Disassemble PDF Document
pdf split; a pdf page cut
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
28
Training
Guide
CTCSS to NAC Conversion
Early TIA documents specifi ed a formula for converting analog CTCSS 
tones and DCS codes to specifi c NAC codes.  Those documents have 
since been removed and the selection of NAC codes has been left 
to the user.  Some government agencies have defi ned a conversion 
table for their own use for translating CTCSS to NAC codes (eg. State 
of California and others).
Shown below is the early TIA conversion table from CTCSS to 
NAC codes.  These codes were determined by taking the CTCSS 
frequency and multiplying it by ten, then converting the integer result 
to a hexadecimal number.
CTCSS to NAC code conversion chart
CTCSS 
NAC Code
67.0 Hz 
$29E
69.3 Hz 
$2B5
71.9 Hz 
$2CF
74.4 Hz 
$2E8
77.0 Hz 
$302
79.7 Hz 
$31D
82.5 Hz 
$339
85.4 Hz 
$356
88.5 Hz 
$375
91.5 Hz 
$393
94.8 Hz 
$3B4
97.4 Hz 
$3CE
100.0 Hz 
$3E8
103.5 Hz 
$40B
107.2 Hz 
$430
110.9 Hz 
$455
114.8 Hz 
$47C
118.8 Hz 
$4A4
123.0 Hz 
$4CE
127.3 Hz 
$4F9
131.8 Hz 
$526
CTCSS 
NAC Code
136.5 Hz 
$555
141.3 Hz 
$585
146.2 Hz 
$5B6
151.4 Hz 
$5EA
156.7 Hz 
$61F
162.2 Hz 
$656
167.9 Hz 
$68F
173.8 Hz 
$6CA
179.9 Hz 
$707
186.2 Hz 
$746
192.8 Hz 
$788
203.5 Hz 
$7F3
206.5 Hz 
$811
210.7 Hz 
$83B
218.1 Hz 
$885
225.7 Hz 
$8D1
229.1 Hz 
$8F3
233.6 Hz 
$920
241.8 Hz 
$972
250.3 Hz 
$9C7
C# WPF PDF Viewer SDK to view, annotate, convert and print PDF in
C# File: Merge PDF; C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages; C# Read: PDF Text Extract; C# Read: PDF
break a pdf into separate pages; split pdf into individual pages
C# HTML5 PDF Viewer SDK to view PDF document online in C#.NET
C# File: Merge PDF; C# File: Split PDF; C# Page: Insert PDF pages; C# Page: Delete PDF pages; C# Read: PDF Text Extract; C# Read: PDF
acrobat split pdf pages; split pdf files
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
29
Training
Guide
Status Symbols
Throughout the Data Units, 2 bit status symbols are interleaved so 
that there is one status symbol for every 70 bits of information.  The  
status symbols allow repeaters to indicate the status of the inbound 
channels to subscribers.  The repeaters assert the status symbols on 
both voice and data messages, indicating inbound activity for both 
voice and data calls.
The subscribers set the value of the status symbol to signify an 
Unknown status in their messages since they are unable to indicate 
the status of any inbound channel.
There are 4 possible values for the status symbol; 01 (for busy), 11 
(for idle), 00 (unknown, used by talk-around) and 10 (unknown, used 
for inbound or outbound).  Repeaters use status symbols 01 and 11, 
and subscribers use status symbols 00 and 10.
There is one value for Busy (01), one for Idle (11), and two values to 
indicate Unknown status.  When the subscriber sends a message on a 
direct channel, it will use the Unknown value for direct mode operation 
(00).  When the subscriber sends a message inbound to a repeater, it 
will use the Unknown value for repeater operation (10).
The reference oscillator stability for repeaters and base stations is 
often better than for subscriber radios.  Subscribers may compare the 
frequency of their local reference oscillator with the carrier frequency 
from a repeater or base station transmitter, in order to adjust and 
improve their local reference oscillator. This adjustment is called 
Automatic Frequency Control (AFC).  AFC operation is anticipated by 
the FCC regulations for the 746-806 MHz band.  Subscribers may 
detect a repeater or base station transmission by checking the values 
of the status symbols on slot boundaries. A repeater or base station 
will transmit Busy or Idle indications on slot boundaries. When a 
subscriber detects these values, it can average enough data symbols 
from a transmission to obtain an estimate of the carrier frequency 
used by the repeater or base station. It can then compare this to the 
receiver local oscillator to determine any frequency corrections to 
improve local reference stability.  After the repeater or base station 
stops transmitting, the subscriber units will be in an unlock state. 
AFC locking resumes when a repeater or base station restarts its 
transmissions.
Status Symbols are not widely used at this time, however there 
are many possible uses for them in the future (such as data / voice 
priority).
(See Chapter 4; Figure 4-3)
C# PDF Convert to HTML SDK: Convert PDF to html files in C#.net
Home ›› XDoc.PDF ›› C# PDF: Convert PDF to HTML. C#.NET PDF SDK - Convert PDF to HTML in C#.NET. How to Use C# .NET XDoc.PDF
break a pdf; reader split pdf
C# PDF Image Extract Library: Select, copy, paste PDF images in C#
PDF. |. Home ›› XDoc.PDF ›› C# PDF: Extract PDF Image. A powerful C#.NET PDF control compatible with windows operating system and built on .NET framework.
break pdf into multiple pages; pdf split file
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
30
Training
Guide
Manufacturer’s ID (MFID)
The Header Code Word and Link Control Word (LDU1) contain the 
8 bit MFID fi eld.  When the manufacturer uses non-standard (data 
only) features, the MFID is asserted.  When all of the other information 
fi elds conform to the Common Air Interface defi nitions, the MFID has 
a standard value of $00 or $01.  A P25 radio must, as a minimum,  
transmit or receive messages using the the standard values for the 
MFID fi eld.  As a minimum, a P25 receiver will ignore messages 
which do not contain the standard values for the MFID fi eld.  Every 
manufacturer is assigned an MFID that can be used for proprietary 
signaling.  Non-standard data from one manufacturer may not pass 
through another manufacturers repeater system.
The MFID’s that have been assigned are:
$10 
Relm / BK Radio
$20 
Cycomm
$28 
Efratom Time and Frequency Products, Inc
$30 
Com-Net Ericsson
$38 
Datron
$40 
Icom
$48 
Garmin
$50 
GTE
$55 
IFR Systems
$60 
GEC-Marconi
$68 
Kenwood Communications
$70 
Glenayre Electronics
$74 
Japan Radio Co.
$78 
Kokusai
$7C 
Maxon
$80 
Midland
$86 
Daniels Electronics Ltd.
$90 
Motorola
$A0 
Thales
$A4 
M/A-COM
$B0 
Raytheon
$C0 
SEA
$C8 
Securicor
$D0 
ADI
$D8 
Tait Electronics
$E0 
Teletec
$F0 
Transcrypt International
(See Chapter 4; Figure 4-4 and Figure 4-6)
C# PDF Convert to Jpeg SDK: Convert PDF to JPEG images in C#.net
›› C# PDF: Convert PDF to Jpeg. C# PDF - Convert PDF to JPEG in C#.NET. C#.NET PDF to JPEG Converting & Conversion Control. Convert PDF to JPEG Using C#.NET.
c# print pdf to specific printer; break pdf password online
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Tell C# users how to: create a new PDF file and load PDF from other file formats; merge, append, and split PDF files; insert, delete, move, rotate, copy and
break pdf into single pages; cannot select text in pdf
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
31
Training
Guide
Algorithm ID (ALGID)
The Header Code Word and Encryption Synchronization (LDU2) 
contain the 8 bit ALGID fi eld.  The ALGID identifi es the encryption 
algorithm used in the P25 system.  The ALGID is entered through 
a Key Management Facility or Key Loader when entering encryption 
keys.
The ALGID’s that have been defi ned for Type 1 algorithms are:
$00 
ACCORDION 1.3
$01 
BATON (Auto Even)
$02 
FIREFLY Type 1
$03 
MAYFLY Type 1
$04 
SAVILLE
$41 
BATON (Auto Odd)
$80 
Unencrypted message (no encryption algorithm)
$81 
DES-OFB encryption algorithm
$82 
2-key triple DES encryption algorithm
$83 
3-key triple DES encryption algorithm
$84 
AES encryption algorithm
(See Chapter 4; Figure 4-4 and Figure 4-7)
Key ID (KID)
The Header Code Word and Encryption Synchronization (LDU2) 
contain the 16 bit KID fi eld.  The KID identifi es the specifi c encryption 
key for use when multiple encryption keys have been loaded into the 
encryption modules.  The KID is also used for single encryption key 
systems.  The typical default KID for clear or secure systems is $0000.  
The KID is entered through a Key Management Facility or Key Loader 
when entering encryption keys.
(See Chapter 4; Figure 4-4 and Figure 4-7)
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
overview. It provides plentiful C# class demo codes and tutorials on How to Use XDoc.PDF in C# .NET Programming Project. Plenty
cannot print pdf no pages selected; acrobat separate pdf pages
C# WPF Viewer: Load, View, Convert, Annotate and Edit PDF
overview. It provides plentiful C# class demo codes and tutorials on How to Use XDoc.PDF in C# .NET Programming Project. Plenty
pdf no pages selected to print; can print pdf no pages selected
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
32
Training
Guide
Message Indicator (MI)
The Header Code Word and Encryption Synchronization (LDU2) 
contain the 72 bit MI fi eld.  The MI is the initialization vector 
(synchronization for key stream generator) for a Type 1, Type 2, 
Type 3 or Type 4 encryption algorithm.  Clear messages are denoted 
$000000000 while secure (encrypted) messages are variable.  The 
Message Indicator is not accessible or programmable by the user.
(See Chapter 4; Figure 4-4 and Figure 4-7)
Talk-group ID (TGID)
The Header Code Word and Link Control Word (LDU1) contain the 
16 bit TGID fi eld.  The TGID identifi es the talk-group for the message.  
The purpose of a talk group is to allow logical groupings of radio users 
into distinct organizations.  The TGID could also be used  to minimize 
co-channel interference and allow subscriber addressing.
TheTGID ranges from hexadecimal $0000 to $FFFF and contains 
65,536 addresses.
The following TGID’s have specifi c functions:
$0001 specifi ed as the default TGID value and should be used in 
systems where no other talk groups are defi ned.
$0000 no-one or a talk group with no users.  Used when 
implementing an individual call.
$FFFF reserved as a talk group which includes everyone.
(See Chapter 4; Figure 4-4 and Figure 4-6)
Low Speed Data 
Each Logical Link Data Unit in a voice message contains the 16 bit 
Low Speed Data fi eld.  The Low Speed Data is intended for custom 
user applications not defi ned by the CAI (possibly GPS location data, 
infrastructure status information, etc.) and has a total capacity of 88.89 
bps.  The Low Speed Data is encoded with a shortened cyclic code to 
create 64 bits per superframe.
(See Chapter 4; Figure 4-6 and Figure 4-7)
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
33
Training
Guide
Unit ID
The Unit ID is a 24 bit user programmable fi eld that is used for both 
group and individual calling.  The Unit ID is used as both a Source ID 
(from the sending unit) and a Destination ID (in the receiving unit in an 
individual call).
The Unit ID ranges from hexadecimal $000000 to $FFFFFF and 
contains 16,777,216 addresses.  The Unit ID’s should be programmed 
into the radios using a national, corporate or agency wide unit 
identifi cation scheme.
The following Unit ID’s have specifi c functions:
$000000 
no-one.  This value is never assigned to a 
radio unit
$000001 to $98967F for general use.
$989680 to $FFFFFE for talk group use or other special purposes.
$FFFFFF 
designates everyone.  Used when 
implementing a group call with a TGID.
Source ID
The Link Control Word (LDU1) contains the 24 bit Source ID fi eld.  
The Source ID is the Unit ID of the SENDING unit.  The Source ID is 
typically sent in all voice messages and is used for both group and 
private calling.
(See Chapter 4; Figure 4-6)
Destination ID
The Link Control Word (LDU1) contains the 24 bit Destination ID fi eld.  
The Destination ID is used for private voice messages only (called 
private or individual calling).  The Destination ID is the Unit ID of the 
intended recipient of the individual call.
(See Chapter 4; Figure 4-6)
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
34
Training
Guide
Emergency indicator
The Link Control word (LDU1) contains the 1 bit Emergency indicator 
fi eld.  The Emergency indicator is embedded in group voice messages  
to indicate an emergency condition.
The emergency indicator bit is designed to be selectable by a switch 
or programming in the subscriber units.  The emergency indicator bit 
can be set as follows:
0 routine, non-emergency condition
1 emergency condition
(See Chapter 4; Figure 4-6)
Link Control Format
The Link Control Format is an 8 bit fi eld contained in the Link Control 
Word (LDU1).  The Link Control Format is used to specify content of 
the Link Control Word.  The Link Control Format is not accessible to 
the user.
(See Chapter 4; Figure 4-6)
Packet Data Unit
There are other digital codes used in the Packet Data Unit such as the 
Service Access Point (SAP), Full Message Flag (FMF), etc.  These 
digital codes will not be defi ned in this document.
P25 VOICE MESSAGE OPTIONS
P25 Radio Systems can perform voice messages in a variety of 
ways or modes.  P25 radio systems will operate in both P25 digital 
mode and conventional analog mode.  Voice messages can be sent 
over a 12.5 KHz bandwidth analog channel using standard analog 
call procedures with analog signaling (CTCSS, DCS, etc.).  Some 
manufacturers also have equipment that will allow operation in 25 KHz 
analog bandwidth.
P25 voice messages can also be sent in P25 digital mode.  P25 voice 
messages can be sent in either encrypted (secure) or unencrypted 
(clear) mode.  The secure / clear operation is typically an option that is 
required to be installed in the subscriber units.
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
35
Training
Guide
There are 3 main ways to send a voice message, with several options 
and variations of each case.   Each of these 3 main ways to send a 
voice message can operate in clear or secure mode.
The three main types of voice message calls are:
Routine Group Call  
This is the most common type of call and is 
intended for a group of users within the radio 
system.  This type of call is typically initiated by 
asserting the PTT switch.
Emergency Group Call  This type of call is similar to a Routine Group Call, 
but is used during an emergency condition.  An 
emergency condition is defi ned by the radio system 
users   This type of call is typically initiated by 
asserting the Emergency switch.
Individual Call  
This type of call is addressed to a specifi c 
individual. The caller enters the subscribers Unit 
ID, that they wish to call, and this is used as the 
Destination ID by the radio making the call.  This 
type of call is made after the Destination ID is 
entered into the radio.
The P25 transmitter has suffi cient controls to support the three main 
types of voice mesages.  These controls are as follows:
PTT Switch - The Push-To-Talk switch is pressed when the user wishes 
to transmit and released when the transmission is over.
Channel Selector - The Channel Selector allows the user of the radio 
to select a radio’s mode of operation.  The Channel Selector controls 
the following parameters of the radio:
1. Frequency
2. NAC
3. TGID
4. Other (eg. selecting the encryption key)
Emergency Switch - The Emergency switch will allow the user to assert 
the emergency condition.  Once asserted, the emergency condition 
remains active until cleared by some other means (eg. turning the 
radio off).
Numeric Keypad / Display - The Numeric Keypad / Display will allow 
the user to set numeric parameters (eg. the Destination ID in an 
individual call).
TG-001 P25 Radio Systems
www.danelec.com
Chapter 3: P25 Practical Applications
36
Training
Guide
Routine Group Call Procedure
• NAC and TGID are set by the user (Channel Selector).
• MFID is set to standard value for CAI transmission.
• MI, ALGID, and KID are set by secure or clear mode parameters.
• Emergency bit is set to indicate non-emergency call.
• Source ID is the Unit ID of the radio.
Emergency Group Call Procedure
NAC and TGID are set by the user (Channel Selector).
• 
MFID is set to standard value for CAI transmission.
• 
MI, ALGID, and KID are set by secure or clear mode parameters.
• 
Emergency bit is set to indicate an emergency call.
• 
Source ID is the Unit ID of the radio.
Individual Call Procedure
• 
The Unit ID of the user to be called is entered into the radio and 
this is the Destination ID.
TGID is set to the null talk group of $0000
• 
NAC is set by the user (Channel Selector).
• 
MFID is set to standard value for CAI transmission.
• 
MI, ALGID, and KID are set by secure or clear mode parameters.
Documents you may be interested
Documents you may be interested