asp.net open pdf : Change font size pdf form software SDK dll winforms wpf windows web forms Onan%20GSBB%20Service%20Manual6-part2105

9-2013
5.Operation
FIGURE27. NETWORKSETUPSCREEN
5.11 ExerciseSettings
Tosetthegeneratorsetexerciseschedule:
1. PresstheEXCERbuttononthehomescreen.
2. PresstheNEXTbuttonontheExerciserClockscreentoselectthefieldtochange.
3. Presstheupordownarrowbuttontoincreaseordecreasethefrequency y ofexerciseand
thedayoftheweekandtimeofdayforexercise.
Frequencyselectionsare:
Weekly
Bimonthly
Monthly
Never
4. PresstheBACKbuttontosavethesettingsandreturntothehomescreen.
5. Ifyouwanttoexercisethegeneratorsetnow,selectExerciseNow,andpresseithertheup
ordownarrow.
A030A239(Issue10)
55
Change font size pdf form - Compress reduce PDF size in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
C# Code & .NET API to Compress & Decompress PDF Document
change font size in pdf form field; change font size in fillable pdf
Change font size pdf form - VB.NET PDF File Compress Library: Compress reduce PDF size in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET PDF Document Compression and Decompression Control SDK
pdf custom paper size; 300 dpi pdf file size
5.Operation
9-2013
NOTICE
Scheduledorpromptedexercisedoesnottransferthehouseloadstothegeneratorset.
FIGURE28. EXERCISECLOCKSCREEN
5.12 TimeSetup
Tosetupthegeneratorsetclockforthecurrentdateandtime:
1. PresstheCLOCKbuttononthehomescreen.
2. PresstheNEXTbuttonontheTimeSetupscreentoselectthefieldtochange.
3. Presstheupordownarrowbuttontoincreaseordecreaseorchangethedateortime.
4. PresstheBACKbuttontosavethesettingsandreturntothehomescreen.
56
A030A239(Issue10)
C# PDF insert text Library: insert text into PDF content in C#.net
Powerful .NET PDF edit control allows modify existing scanned PDF text. Ability to change text font, color, size and location and output a new PDF document.
change font size in fillable pdf form; change page size pdf
C# PDF Field Edit Library: insert, delete, update pdf form field
Able to add text field to specified PDF file position in C#.NET class. Support to change font size in PDF form. Able to delete form fields from adobe PDF file.
change paper size pdf; adjust pdf page size
9-2013
5.Operation
FIGURE29. TIMESETUPSCREEN
5.13 LoadManagement
Thegeneratorsetmayhavebeensetupatinstallationtoconnectanddisconnectcertainlarge
loads,suchasairconditioners,tomanagethetotalloadsoasnottooverloadthegeneratorset.
This requires the installation of relays to the load management t signals s which allow for the
disconnectionofloads.Loadmanagementcanbesettooperateinautomaticormanualmode.
Whetherinautomaticormanualmode,thereisadelayedstart.Load1isenabledthreeminutes
afterthegeneratorsetisconnectedtothehouseloads,andLoad2isenabledsixminutesafter
thegeneratorsetisconnectedtothehouseloads.
5.13.1 AutomaticLoadManagement
When set t to o automatic c mode, the e user takes s no o action n and can n only y view which loads are
connected. Three minutesafter the generatorstarts,theloadthatis connected togensetload
L1isconnected.Afteradelayofthreemoreminutes,theloadthatisconnectedtogensetload
L2 is connected. If the connection of loads L1 and L2 exceeds 95% of the e generator's load
capacity, they are disconnected by y the generator. . Following another three e minute e delay, the
controlreconnectsbothloadsfollowingthesameconnectionsequenceusedinthefirstattempt
(threeminutesapart).Ifgeneratorloadcapacityisexceededagain,bothloadsaredisconnected
andnofurtherreconnectionistried.
Toselectautomaticloadmanagementandviewwhethertheselectedloadsareconnectedwhile
thegeneratorsetisrunning:
1. PresstheLOADbuttononthehomescreen.
2. PresstheupordownarrowbuttontoselectAutomatic.
3. Notewhichloadsareconnectedordisconnected.
4. PresstheBACKbuttontoreturntothehomescreen.
Adjustpercentloadtomatchthede-rate.
A030A239(Issue10)
57
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Able to edit and change PDF annotation properties such as font size or color. Abilities to draw markups on PDF document or stamp on PDF file.
adjust size of pdf in preview; pdf form change font size
C# PDF Sticky Note Library: add, delete, update PDF note in C#.net
Allow users to add comments online in ASPX webpage. Able to change font size in PDF comment box. Able to save and print sticky notes in PDF file.
pdf reduce file size; pdf file size limit
5.Operation
9-2013
5.13.2 ManualLoadManagement
CAUTION
Toreduceunnecessarylossofservice,itishighlyrecommendedthatmanualload
managementbeundertakenonlybyanauthorizedCumminsOnandealer.
When set t to manual mode, the user is able to view, connect, and disconnect loads. If the
connectionofloadsL1andL2exceedsgeneratorcapacity,theACcircuitbreakertrips.
Toselectmanualloadmanagementwhenthegeneratorisrunning:
1. PresstheLOADbuttononthehomescreen.
2. PresstheupordownarrowbuttontoselectManual.
3. Notewhichloadsareconnectedordisconnected.
4. Pressthedouble-downarrowbuttontogotheloadconnect/disconnectscreen.
5. Connect t or disconnect t Load d 1 1 or Load d 2 2 as necessary y by y pressing g either r button n under
Load1orLoad2.
6. PresstheBACKbuttontosavethesettingandreturntothehomescreen.
FIGURE30. LOADMANAGEMENTSCREEN
58
A030A239(Issue10)
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
PDF document, keeps the elements (like images, tables and chats) of original PDF file and maintains the original text style (including font, size, color, links
change font size fillable pdf; adjust file size of pdf
Generate Barcodes in Web Image Viewer| Online Tutorials
Select "Generate" to process barcode generation; Change Barcode Properties. Select "Font" to choose human-readable text font style, color, size and effects;
pdf optimized format; pdf file compression
6
StartupandConfiguration
6.1
Pre-startupInspection
Beforestartingthegensetinspecttheinstallationandcheckoffeachofthefollowingquestionsif
itcanbeanswered“YES".Ifaquestioncannotbecheckedoff,reviewtheappropriatesectionin
themanual.
• []Canthetop,maintenanceandserviceaccessdoorsbeswungfullyopenforoperation,
maintenanceandservice?
• []Arethecoolingairinletandoutletopeningsfreeofobstructions?
• []HavetheACoutputconnectionsbeenmadeproperly?
• []Hasthetransferswitchbeeninstalledproperlytopreventconnectingthegeneratorset
totheutility?
• []Hasaproperlysizedbatterybeeninstalled?
• []Areallfuelconnectionstight?
• []Isfuelsupplypressurecorrect?
• []Areelectricalandfuellinesproperlyseparated?
• []Doesengineexhaustdisperseawayfrombuildings?
• []Haveallfuelconnectionsbeencheckedforleaks?
• []Isthefuelsupplypressuretotheinletofthegeneratorsetappropriatelysetforthefuel
beingused?
• []Doestheinstallationmeetallapplicablelocal,state,andfederalcodes?
• []Isthefuelregulatorventscreenfreeofobstructions?
• []Isthemanualfuelselectorsettoproperfuel?
6.2
Startup
When allinstallation n requirements have e been met, , connect t the battery cables s to o the battery,
positive(+)cablefirst.
WARNING
Automaticstartupofthegeneratorsetduringinstallationcancauseseverepersonalinjuryor
death.PushthecontrolswitchOFFanddisconnectthenegative(–)cablefromthebatteryto
keepthegeneratorsetfromstarting.
Read through the Operator's Manual and perform the e maintenance and d pre-start checks
instructed.Thegensetisshippedfromthefactorywiththeproperlevelofengineoil,butshould
be checked d before the genset t is s started. . Start and operate the genset, following all l the
instructionsandprecautionsintheOperatorManual.
PerformGeneratorSetConfiguration.
A030A239(Issue10)
59
VB.NET Image: Visual Basic .NET Guide to Draw Text on Image in .
Please note that you can change some of the example, you can adjust the text font, font size, font type (regular LoadImage) Dim DrawFont As New Font("Arial", 16
change font size pdf text box; pdf paper size
Generate Image in .NET Winforms Imaging Viewer| Online Tutorials
Click "Generate" to process barcode generation; Change Barcode Properties. Click "Font" to choose human-readable text font style, color, size and effects.
change paper size in pdf; advanced pdf compressor online
6.StartupandConfiguration
9-2013
NOTICE
Beforeleavingthesite,ifthegensetisreadytobeplacedinservice,setthecontrolswitchtothe
REMOTEpositiontoprovideautomaticstandbypower.
6.3
GeneratorSetConfiguration
Theoperatorpanelhasamenuwithfourgeneratorset/transferswitchparametersthatmustbe
configuredfortheinstallation.
Toconfigurethegeneratorset:
1. PresstheMENUbuttononthehomescreen.
2. Press s and d hold the blank (far left, solidblack) button on the menu screen for at least 5
secondstogototheConfigMenu.
3. PresstheupordownarrowbuttonontheConfigMenuscreentoselectGeneratorConfig.
4. PressEnterontheConfigMenutogototheGeneratorConfigscreen.
5. Press s the e NEXT button on the Generator Config g Menu u screen to select the Config,
FrequencyorRatingfield.
6. Presstheupordownarrowbuttontoincreaseordecreasetheconfigurationparameter.
a. Config:Selectappropriateconfiguration(dependingonmodelandfuel)fromthetable
shownbelow.
b. Frequency:Select60Hzor50Hz.
c. Rating:Ratingwillbefilledin,basedontheconfigurationselected.Thisvaluecanbe
lowered in order to correctly de-rate for high altitudeor hot climates. (Selecting the
correct Amps value e will l also o allow w the correct genset t load d to o be e displayed d on n the
OperatorPanel.
d. PresstheBACKbuttontosavethesettingandreturntothehomescreen.
TABLE14. CONFIGURATIONS,BASEDONMODELANDFUELTYPE
Model(Spec)
Fuel
Configuration
GSBBSpecAandCanadianGSBB
NaturalGas
14
SpecB
GSBBSpecAandCanadianGSBB
Propane
15
SpecB
USGSBBSpecBandCanadian
NaturalGas
18
GSBCSpecB
USGSBBSpecBandCanadian
Propane
19
GSBCSpecB
60
A030A239(Issue10)
9-2013
6.StartupandConfiguration
FIGURE31. GENERATORCONFIGURATION
A030A239(Issue10)
61
6.StartupandConfiguration
9-2013
6.4
GeneratorAdjustments
6.4.1 ToAdjusttheOutputVoltage
Usethefollowingprocedure:
1. ConnectanaccurateACvoltmeteracrossL1andL2whilethegeneratorsetisrunning.
2. WithOutputVoltsselectedontheAdjustmentsMenuscreen,presstheupordownarrow
buttontoadjustthevoltagetothedesiredsetting
3. Thecontrolallowsanadjustmentof240VAC±7%(17VAC).
4. PresstheBACKbuttontosavethesettingsandreturntothehomescreen.
6.4.2 ToCalibratetheDisplayMeter
Usethefollowingprocedure:
1. ConnectanaccurateACvoltmeteracrossL1andL2whilethegeneratorsetisrunning.
2. PresstheNEXTbuttontoselecttheDisplayCalfield(screennotshown).
3. Presstheupordownarrowtoadjustthevoltagereadingonthescreenuntilitmatchesthe
meterreading.
4. PresstheBACKbuttontosavethesettingsandreturntothehomescreen.
FIGURE32. ADJUSTMENTMENUSCREEN
6.5
TransferSwitchConfiguration
Toconfigurethegeneratorsetforthetransferswitchbeingused:
1. PresstheMENUbuttononthehomescreen.
2. Press s andholdthe blank buttonon the menu screenforat least 5 secondsto goto the
ConfigMenu.
3. PresstheupordownarrowbuttonontheConfigMenuscreentoselectTSConfig.
4. PressEnterontheConfigMenutogototheTransferSwitchscreen.
5. Press s the e up p or r down arrow w button to o select t between n two o choices: “RSS100-6868 8 and
RSS200-6869"or“RSS100-6634andRSS200-6635,"whichmustmatchthemodelnumber
ofthetransferswitchbeingused.
NOTICE
Fornon-CumminsOnantransferswitches,selectRSS100-6634andRSS100-6635.
62
A030A239(Issue10)
9-2013
6.StartupandConfiguration
6. PresstheBACKbuttontosavethesettingandreturntothehomescreen.
FIGURE33. TRANSFERSWITCHCONFIGURATION
6.6
TransferSwitchParameterAdjustments
Model RSS100-6634 and RSS200-6635 Transfer r Switches: Refer to o Transfer Switch
InstallationManual962-0620tosettheparametersinsidethetransferswitch.
Model RSS100-6868 and d RSS200-6869 9 Transfer r Switches: To make transfer switch
parameteradjustments:
1. PresstheMENUbuttononthehomescreen.
2. Press s andholdthe blank buttonon the menu screenforat least 5 secondsto goto the
ConfigMenu.
3. PresstheupordownarrowbuttonontheConfigMenuscreentoselectTSAdjustments.
A030A239(Issue10)
63
6.StartupandConfiguration
9-2013
4. PressEnterontheConfigMenutogototheTransferSwitchscreen.
5. PresstheNEXTbuttonontheGeneratorConfigMenuscreentoselectthePickup,Dropout
orNominalfield.
6. TosetNominal-Presstheupordowndouble-arrowbuttontoincreaseordecreasethe
nominalutilityvoltageparametertomatchactual(Present)utilityvoltage.ThePickupand
Dropoutparametersarepercentagesofthenominalvoltageparameter.
7. To set Pickup- Press s the up or r down double-arrowbutton to increase or decrease the
minimumutilityvoltagetowhichthetransferswitchwillconnect.Defaultis90%ofnominal.
Itcanbeincreasedto95%ofnominal.
8. To set Dropout- Press s theup ordown double-arrowbutton toincreaseordecrease the
minimum utility voltage at which the transfer switch h will l disconnect. . Default is s 85% % of
nominal.Itcanbedecreasedto80/75/70%ofnominal.
9. PresstheBACKbuttontosavethesettingandreturntothehomescreen.
FIGURE34. TRANSFERSWITCHADJUSTMENTS