107
IEI Hub Manager Professional v8 
Chapter 6: Database
Setup Method Definitions
Dynamic IP Address via DHCP server, IP Address in SEG can change
This method means the SEG is assigned an IP Address by the DHCP server on your
network. Once the DHCP servers knows the MAC Address of the SEG, the IP
Address can change and Hub Manager™ Professional will automatically retrieve the
IP Address from the SEG each time it attempts to communicate to it. This is the
recommended method but it requires SEG v1.3 or greater firmware. Refer to the 
Dynamic IP Address
section for further details.
Dynamic IP Addressing via DHCP server with non-expiring lease, IP Address in
SEG does not change
Using this method, you simply give the IT department the MAC Address of the SEG
and ask them to assign it an IP Address with a non-expiring lease. Refer to the 
Dynamic IP Address non-expiring lease
section for further details.
Static IP Address, IP Address in SEG does not change
You would use this method if you want to assign the SEG a fixed or static IP Address
that does not change. The static IP address is set through the serial port of the SEG
using the PC's serial communications port (or through the USB port using a USB to
RS232 adapter). This method allows you to configure the IP address of the SEG
without any network devices such as a router or a network switch interfering. Refer to
the Static IP Address
section for further details.
Pdf change page size - Compress reduce PDF size in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
C# Code & .NET API to Compress & Decompress PDF Document
reduce pdf file size; change paper size in pdf document
Pdf change page size - VB.NET PDF File Compress Library: Compress reduce PDF size in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET PDF Document Compression and Decompression Control SDK
pdf edit text size; pdf optimized format
108
IEI Hub Manager Professional v8 
Chapter 6: Database
SEG Site Parameters
IP Address
The IP address of the SEG.
IP Port 
The IP Port is a channel that the SEG is configured to listen on for communications
from Hub Manager™ Professional. This is set to 9997 by default, but can be changed
both in Hub Manager™ Professional and in the SEG, if necessary. 
NOTE: Do not change the IP Port value unless instructed to do so by your IT
Administrator.
SEG Serial Net Number
This number refers to the serial port located on the SEG device itself. The SEG is
capable of connecting to both RS232 and RS485 products, which are Serial Net
Numbers 1 and 2 respectively. This parameter is displayed for reference only and
cannot be changed.
Security Key
The security key is a 128-bit AES encryption key used to encrypt the data sent
between the PC and the SEG. The security key is stored in Hub Manager™
Professional in each SEG site and it must match the security key stored in the SEG.
You can change this key at any time, but you must make sure the SEG and Hub
Manager™ Professional have the same number.
WARNING: It is highly recommended that you change the encryption security key
during the initial SEG setup. All new SEG devices are shipped with the same
initial security key and Hub Manager™ Professional is also shipped with this
same security key. If you don't change the security key, anyone running Hub
Manager™ Professional on their PC somewhere else on your LAN would be able
to communicate with your door controllers. Once you change the security key to
a new 128-bit number, then all the data that is passed out the ethernet port of
your PC is encrypted with that key and decrypted by the SEG using the same
key.
VB.NET Image: How to Create Visual Basic .NET Windows Image Viewer
formats, including png, jpeg, gif, tiff, bmp, PDF, and Word can get a basic idea of the page layout from from that, you are entitled to change the orientation
change page size pdf acrobat; pdf files optimized
C# PDF insert text Library: insert text into PDF content in C#.net
formatted text and plain text to PDF page using .NET NET PDF edit control allows modify existing scanned PDF text. Ability to change text font, color, size and
pdf file compression; pdf reduce file size
109
IEI Hub Manager Professional v8 
Chapter 6: Database
Generate Random Security Key
This button generates a random 128-bit security key and displays the hexadecimal
representation in the Current Security Key field, as shown in the example below.
To send the new security key to the SEG, refer to the Set the above Security Key
into the SEG section below.
Set the above Security Key into the SEG
Use this option to set the security key stored in theCurrent Security Key  field into
the SEG.  Hub Manager™ Professional then attempts to communicate with the SEG
and change the security key stored in the SEG. Once this new key is successfully
set into the SEG a confirmation message is displayed.
NOTE: In order to change the security key in a SEG, Hub Manager™ Professional
must know the existing security key stored in the SEG. If you think there has
been a mix up, and you think Hub Manager™ Professional may not know the
SEG's security key, then you should perform the steps to Reset the Security Key
to all 0's as noted in the sections below. When the process is complete, you can
then change the security key.
C# PDF Convert: How to Convert Word, Excel, PowerPoint, Tiff
Support conversion to PDF from other documents, keeping original document page size. Support rendering image to a PDF document page, no change for image size.
reader compress pdf; best way to compress pdf file
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Able to edit and change PDF annotation properties such as font size or color. Perform Various annotations on PDF Page using C#.NET Demo Codes.
change font size in fillable pdf; pdf form change font size
110
IEI Hub Manager Professional v8 
Chapter 6: Database
Reset the Security Key in the SEG to all 0's for SEG v1.3 Firmware or
Greater
The following instructions apply if your SEG firmware version is v1.3 or greater. Refer to the
section named Reset the Security Key in the SEG to all 0's for SEG Firmware Prior to
v1.3
if you have a older version of SEG firmware.
This feature allows you to reset the security key in the SEG back to all 0's, which is the
default out-of-box state. Resetting the security key in the SEG is required if you are
replacing a SEG with a previously used SEG that already has a security key set into it
and you don't know what the security key is, or if you are setting up a new site and want
to communicate with an existing SEG that is already installed and already has a security
key set. This process may also be necessary if you have used the Restore Database
function of Hub Manager™ Professional and the security key stored in the restored
database does not match the security key currently stored in the SEG.
1.
First go to the SEG and either cycle power to it or press the little black reset
button on the SEG.
2.
Within 10 minutes, go back to the PC and select the button called Reset the
Security Key in the SEG to all 0's.
3.
The warning message shown below is then displayed, which describes the
requirements for using this feature. Once you have met all the requirements
press the OK button.
C# PDF Thumbnail Create SDK: Draw thumbnail images for PDF in C#.
public override Bitmap ConvertToImage(Size targetSize). Description: Convert the PDF page to bitmap with specified size. Parameters:
change font size pdf text box; apple compress pdf
C# PDF File Split Library: Split, seperate PDF into multiple files
Divide PDF file into multiple files by outputting PDF file size. control, C# developers can easily and accurately disassemble multi-page PDF document into two
advanced pdf compressor; change font size on pdf text box
111
IEI Hub Manager Professional v8 
Chapter 6: Database
4.
If the Key was reset properly then the confirmation message shown below is
displayed.
5.
As a security measure, you must now go back to the SEG and either cycle
power or press the reset button on the SEG. This sets the new security key
into non-volatile memory. If you do not reset the SEG after the security key is
reset you will not be able to communicate with the SEG.
6.
The process is complete and the security key is reset to all 0's in both the
SEG and PC. You should now be able to communicate to your SEG.
VB.NET PDF File Split Library: Split, seperate PDF into multiple
Separate source PDF document file by defined page range in VB.NET class application. Divide PDF file into multiple files by outputting PDF file size.
pdf file size limit; pdf text box font size
Create Thumbnail Winforms | Online Tutorials
editor: Click "Add" to add new items in thumbnail; Click "Swap" to change two items Multi-page Tiff Processing; RasterEdge OCR Engine; PDF Reading; Encode &
adjust file size of pdf; pdf font size change
112
IEI Hub Manager Professional v8 
Chapter 6: Database
Reset the Security Key in the SEG to all 0's for SEG Firmware Prior to
v1.3
The following instructions explain how to reset the Security Key of the SEG back to an
out-of-box setting of all 0's, and when used in conjunction 'Reset Security Key in PC to all
0's' will allow you to synchronize the Security Key of the SEG with the Security Key in the
Site Settings screen in the Hub Manager™ Professional software.
This procedure must be followed if the firmware version of the SEG is prior to v1.3. 
NOTE: Steps 10, 11, and 12 are directly related to resetting the Security Key, these
steps should be followed exactly. The other steps specify the out-of-box default values
for the other security settings in that menu system. You can enter the default values
specified here, or other settings can be changed by a Network Administrator as
required. Please refer to the section named Static IP Address
> SEG Menu System
for more details on the individual Security menu items.
1.
Follow the procedure located in the Static IP Address
section to enter the SEG
menu.
2.
Once the SEG menu is open select option 6 Security, by pressing 6 followed
by the Enter key.
3.
You will now be presented with each security setting (not all settings are
displayed on all revisions of SEG).
4.
Disable SNMP  ?  Press N
5.
SNMP Community Name (public):  Enter nothing, just press Enter
6.
Disable telnet Setup  ? Press N
7.
Disable TFTP Firmware Update ?  Press N
8.
Disable Port 77FEh ? Press N
9.
Disable Web Server ? Press N
10.
Disable Web Setup ? Press N
11.
Enable Encryption ? Press Y
12.
............................Change Key? Press Y
13.
Enter pass key of 32 hex digits (16 bytes) .  Press 0 32 times  This resets the
security key   
14.
Disable Echo ports ? Press Y
15.
Enable Enhanced Password ? Press N
16.
When complete and the 'Change Setup' menu appears, select option 9 save
and exit by pressing 9 followed by the Enter key.
The security settings of the SEG is now set back to IEI out-of-box defaults. Refer to
the section relevant to your application to reconfigure your SEG.
NOTE: Once the Security Key is rest to all 0's, you need to follow the to Reset the
Security Key in the PC to all 0's
, then specify a new security key and use the Set the
113
IEI Hub Manager Professional v8 
Chapter 6: Database
Above Security Key into the SEG option.
Reset the Security Key in the PC to all 0's
Use this feature to reset the security key in the PC back to all 0's. Typically you would
use this option if you replaced an existing SEG with a new SEG or you reset your SEG
security key to all 0's.
NOTE: If you use this feature and the SEG does not have a security key of all 0's then
you must also set the security key in the SEG back to all 0's.
6.4.5.1
Dynamic IP Address
Dynamic IP Address via DHCP server, IP Address in SEG can change
IEI recommends using this configuration when setting up your SEG, but it requires
SEG v1.3 or greater firmware. The firmware label is located on top of the SEG.
NOTE: The SEG units that shipped prior to v1.3 did not have a version label on
them. If the SEG you are setting up does not have a version label, then the
firmware is prior to v1.3 and you cannot use this method and you MUST use one
of the other 2 methods to assign an IP Address to that particular SEG.
Using this method, no manual setup of the SEG IP Address via the SEG serial port is
required.
114
IEI Hub Manager Professional v8 
Chapter 6: Database
If you are installing more than one SEG on your LAN you just need to write down the
12 digit MAC Address located on the label of the SEG and write down which controller
group that SEG is connected to for reference. For example:
MAC Address
Description
00-20-4A-52-F2-84  
Building 1, Floor 2, HubMaxII
00-20-4A-52-8B-89  
Building 1, Floor 7, HubMaxII
00-20-4A-52-F4-12  
Building 2, Floor 1, prox.pad plus
1.
Press the button on the TCP/IP Parameters screen named Search for SEG
Devices to start this process.
115
IEI Hub Manager Professional v8 
Chapter 6: Database
2.
A warning message is displayed reminding you that you must have firmware
version 1.3 or higher for this process to work. Select Yes to continue the
search.
3.
In approximately 5-10 seconds all SEG devices Hub Manager™ Professional
found are displayed in a grid on the right side, as shown below.
116
IEI Hub Manager Professional v8 
Chapter 6: Database
4.
The message below is displayed asking you to select a SEG in the grid. Click
the OK button.
5.
Now click on the SEG in the grid that has the same MAC Address as the SEG
you are using for this site.
6.
A message is displayed asking you to generate a new Security Key. Click on
the OK button.
7.
If you don't want to set the security key at this time then setup is complete,
select Save to save and close the setup screen.
8.
If you do want to change the security key, click the button labeled Generate
Random Security Key.
9.
A message will then tell you to select the button labeled Set the Above
Security Key into the SEG. Click the OK button.