INFORMATION  
AND GUIDANCE  
FOR CUSTOMER  
ELECTRIC SERVICE  
Change font size in pdf form field - Compress reduce PDF size in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
C# Code & .NET API to Compress & Decompress PDF Document
change font size pdf form; adjust pdf page size
Change font size in pdf form field - VB.NET PDF File Compress Library: Compress reduce PDF size in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET PDF Document Compression and Decompression Control SDK
pdf change page size; change font size in pdf form
November 2009  
(PAGE INTENTIONALLY BLANK) 
C# PDF Field Edit Library: insert, delete, update pdf form field
Able to add text field to specified PDF file position in C#.NET class. Support to change font size in PDF form. Able to delete form fields from adobe PDF file.
pdf edit text size; adjusting page size in pdf
C# PDF Sticky Note Library: add, delete, update PDF note in C#.net
Allow users to add comments online in ASPX webpage. Able to change font size in PDF comment box. Able to save and print sticky notes in PDF file.
pdf text box font size; best pdf compressor online
November 2009  
CONTENTS  
INTRODUCTION
....................................1
DEFINITIONS
........................................2
GENERAL INFORMATION
...........................4
Availability & Character of Service
............................................4
Application for Service
....................................................4
Line Extensions
.......................................................5
Number of Services & Meters
.............................................5
Use of Service by Customer
...............................................6
Interruption & Liability 
....................................................6
Final Connections
......................................................7
Inspection
............................................................7
Meter & Seal Tampering
................................................8
Meter Attachments
.....................................................8
Disconnect/Reconnect of Existing Service (Upgrades)
...............................8
Locating Underground Electric Facilities
.........................................9
Required Clearance from Markout for Digging in the Vicinity of Company Underground Electric Facilities.......................9
TEMPORARY SERVICE
...........................10
PERMANENT SERVICE – OVERHEAD
..............10
Gene
...........................................................10
Service Drop Clearances
................................................11
Clearance of Trees from Power Lines
........................................11
Mobile Homes or Mobile Home Parks
....................................11
Travel Trailer or RV Parks
...............................................12
Central Pole Distribution Metering
...........................................12
PERMANENT SERVICE – UNDERGROUND
........12
Gene
...........................................................12
Underground Services from Overhead Lines
..................................13
Underground Services in Underground Residential Areas
..........................13
Underground Services in Underground Commercial Areas
.......................14
Underground Services in Central Business District Network Areas......................................................................................14
Transformer Foundations & Vaults
........................................14
Mobile Homes or Mobile Home Parks
....................................15
MINIMUM REQUIREMENTS FOR ALL METER SOCKETS
16
Minimum Size Meter Socket - 480-Volt Services
...............................21
Installations Requiring 320 Amperes & Less of Continuous Metering Load........................................................................21
Installations Requiring Over 320 Amperes of Continuous Metering Load...........................................................................21
Approved Current Transformer Cabinets
....................................22
Meter Lo
......................................................23
Service at Voltages Greater Than Secondary (Greater Than 600 V).....................................................................................24
Pad-mounted & Cubicle Primary Service from Overhead Lines – 34.5 kV Wye & Below..................................................25
Customer-Owned Transformer Guidelines
..................................26
Disconnect Requirements
..............................................27
CUSTOMERS’ EQUIPMENT
.......................28
Motors (Inrush Limitations & Motor Protection)
.................................28
Power Factor
.......................................................31
Welders & Industrial Furnaces
............................................31
Commercial Cooking, Space Heating, Water Heating, & Ice / Snow Melting......................................................................31
Special Equipment
...................................................31
Low-Voltage Surge Arresters (750 Volts or Less)
................................32
UPS, Cogeneration, & Back-up Generation
..................................32
Harmonic Producing Equipm
.........................................32
Protective Devices
....................................................32
GENERAL NOTES APPLYING TO EXHIBITS
..........33
C# PDF insert text Library: insert text into PDF content in C#.net
Powerful .NET PDF edit control allows modify existing scanned PDF text. Ability to change text font, color, size and location and output a new PDF document.
change font size in fillable pdf; best pdf compressor
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Support to add text, text box, text field and crop marks to PDF document. Able to edit and change PDF annotation properties such as font size or color.
pdf text box font size; change font size in fillable pdf
November 2009  
Temporary Service - Residential/Commercial  
Overhead
........Exhibit 1  
Underground
......Exhibit 2  
Permanent Service - Residential/Commercial  
Overhead  
Residential Entrance InstallationExhibit 3
Service Drop AttachmentExhibit 
3A  
Residential Service Mast InstallationExhibit 4  
Direct Attachment of Customer Service(s) in Conduit on Company Poles.....................Exhibit 6A/B  
Standoff Attachment of Customer Service(s) in Conduit on Company Poles.................Exhibit 7A/B  
Central Distribution InstallationExhibit
9  
Mobile Homes & Travel Trailer Parks
Exhibit 11  
Single Mobile Home ServiceExhibit 12
CT Installation  
Indoor/OutdoorExhibit 
16  
On a BuildingExhibi
t 17  
Underground  
Service Lateral InstallationExhib
it 5A/B  
Direct Attachment of Customer Service(s) in Conduit on Company Poles.....................Exhibit 6A/B  
Standoff Attachment of Customer Service(s) in Conduit on Company Poles.................Exhibit 7A/B  
Central Distribution InstallationExhibit
10  
Mobile Home Parks & Travel Trailer Parks.....................................................................Exhibit 11  
Single Mobile Home ServiceExhibit 12
CT Installation  
Indoor/OutdoorExhibit 
16  
Pad-Mounted TransformersExhibit 18  
Metering  
Service Lateral InstallationExhib
it 5A/B  
Multiple Metering, Residential/Commercial Single-Phase 400 Amp Max.......................Exhibit 8  
Mobile Home Parks & Travel Trailer Parks.....................................................................Exhibit 11  
Single Mobile Home ServiceExhibit 12
Add-On Heat Pumps (Separately Metered)....................................................................Exhibit 13  
Indoor/Outdoor Self-Contained Metering Three-Phase Less Than 400 Amp.................Exhibit 14  
Indoor/Outdoor Three-Wire Network 208Y/120 Volts.....................................................Exhibit 15  
Metering Installation – Single-Phase & Three-Phase 480 V Self-Contained Meter  
With Source-Side DisconnecExhibit 22 
CT Installation Indoor/Outdoor
....Exhibit 16  
On a Building
.Exhibit 17  
Underground Service in Pad-Mounted Transformer.......................................................Exhibit 18  
Service Material Guideline  
Applications With Self-Contained Metering  
Ohio Edison Exhibit 1
9A  
Illuminating Company Exhibit 19B  
Penn PoweExhi
bit 19C  
Toledo Edison Exhi
bit 19D  
Jersey Central Power & LightExhi
bit 19E  
Met-Ed
Exhibit 19F  
Exhibi
t 19G  
Applications With Current Transformers  
Ohio Edison Exhibit 
20A  
Illuminating CompanyExhibit 20B  
Penn PoweExhi
bit 20C  
Toledo Edison Exhibit 2
0D  
Jersey Central Power & LightExhi
bit 20E  
Met-EdExhi
bit 20F  
PenelecExhib
it 20G  
Minimum Clearances – Structures to Pad-Mounted Transformers..............................................Exhibit 21  
Trench Details for Direct Buried Cables
Exhibit 22
C# PDF Text Box Edit Library: add, delete, update PDF text box in
Support to change font color in PDF text box. Ability to change text size in PDF text box. Adding text box is another way to add text to PDF page.
change font size pdf text box; adjust size of pdf in preview
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
PDF document, keeps the elements (like images, tables and chats) of original PDF file and maintains the original text style (including font, size, color, links
.pdf printing in thumbnail size; pdf file compression
November 2009  
SUMMARY OF MAJOR CHANGES TO THIS DOCUMENT
(November 2008)  
1. 
Revised Table of Contents
Edit the headings and page numbers to match the revisions.   
2. 
Revised Page 2 - Introduction
Insert the highlighted sentence for clarity:   
The information contained within this Guide is supplementary to, and does not intentionally conflict with 
the National Electrical Code (NEC), the Company’s current applicable tariffs, or such state and municipal 
laws and ordinances as may be in force within the states, cities, towns, or communities in which the 
Company furnishes electric service.  It is always necessary to refer to and comply with state statutes, 
local ordinances, and the Company's standard rules and regulations on file with the public utility 
commissions.  To the extent that any included information contradicts any terms in the Company’s current 
applicable tariff, the tariff provision shall govern.  
This information is general and does not include every 
detail or every lawful requirement.   
3. 
Revised Page 2 - Introduction
Insert the highlighted sentence and delete the last sentence for clarity:   
[From the Home page select the appropriate Operating Company from the Drop Down Box and then click 
on “Go”, next click on the “Builder & Contractor” tab.  
Appendices
referenced but not detailed in this 
document are also available at the website.
4. 
Revised Page 2
- Definitions
For clarity resulting from recent Tariffs changes in some Regions, remove the last sentence:  
Line Extension: A line extension is any addition to the Company's existing primary distribution lines and 
facilities that must be made to render electric service to a customer.  Typically, line extensions require 
customer contributions as defined by each Operating Company’s Tariff.
5. 
Revised Page 8 - Disconnect/Reconnect of Existing Service (Upgrades)
For clarity resulting from recent Tariffs changes in some Regions, remove the first paragraph  
Whenever a customer or electrical contractor requests the Company to perform a service 
d
isconnect/reconnect, both during and outside of the Company’s normal work hours, there are fixed 
charges associated with this activity.  These charges shall be payable to the Company through the 
customer’s electric service account.  There will charges for 
all Company disconnect/ reconnect work, 
including those activities that electrical contractors are not permitted to perform, as detailed below.  
6. 
Revised Page 12 - General 
Revise the following first two paragraphs as shown for clarity:  
Based on an engineering evaluation, a Company representative will determine a pole, pad-mounted 
transformer, or handhole/pedestal
location to which an underground service lateral can be extended.   
Typically, 
the customer is responsible for the trenching, providing conduit where applicable, and 
backfilling.  Refer to Exhibit 23 for trench details for direct buried cables.  Since the actual trench 
dimensions may vary by soil condition, location, and other factors, it is necessary to confirm trench 
dimensions with the Company representative.  
VB.NET PDF Form Data Read library: extract form data from PDF in
RasterEdge.Imaging.Font.dll. As String = Program.RootPath + "\\" 1_AF.pdf" Dim fields ToString()) Console.WriteLine(" Size: " + field.Size.ToString()) Next
change font size on pdf text box; change font size pdf comment box
C# PDF Form Data Read Library: extract form data from PDF in C#.
RasterEdge.Imaging.Font.dll. Program.RootPath + "\\" 1_AF.pdf"; List<BaseFormField Position.ToString()); Console.WriteLine(" Size: " + field.Size.ToString
adjust pdf size; pdf change page size
November 2009  
7. 
Revised Page 12 - General 
Add the following new paragraph (after the fourth paragraph):  
In situations where the customer owns and installs the underground service lateral, the contractor shall 
run the service lateral to within three feet of the designated Company pad-mounted transformer or 
handhole/pedestal or within six inches of overhead secondary for a vertical riser installation.  (Caution: 
Facilities may be energized.)  The contractor shall leave sufficient spare amount of coiled cable to 
complete termination of the cables – five feet for handholes/pedestals, ten feet for transformers, or five 
feet vertical risers.  Refer to the appropriate Exhibit 19 or 20 to determine the party responsible for 
supplying the connectors to terminate the service lateral cable at the source end.  
8. 
Revised Page 13 - Underground Services in Underground Residential Areas 
Add reference to exhibits: 
For single-phase customer-owned underground services at 400 amps or less, the customer shall install 
only one set of service cables sized for the expected load.  Multiple or parallel sets of cables are not 
acceptable for services at 400 amps or less.  Refer to Exhibits 6, 7, and 19
.   
9. 
Revised Exhibits 6A and 7A (11/09)
Revise the various roles that Toledo Edison and their customers make for these types of installations.  
10. 
Revised Exhibit 19D and 20D (11/09)
Revise Note 3 as follows: 
Because of recent Tariff changes, revise the various ownership roles that Toledo Edison and their 
customers make. 
11. 
New Exhibit 23
Insert new exhibit to clarify customer Trench Details for Direct Buried Cables
. 
November 2009  
1
INTRODUCTION  
• This Guide is for information and guidance to assist customers and their architects, engineers, and 
contractors in planning for and obtaining prompt electric service.   
• The information contained within this Guide is supplementary to, and does not intentionally conflict 
with the National Electrical Code (NEC), the Company’s current applicable tariffs, or such state and 
municipal laws and ordinances as may be in force within the states, cities, towns, or communities in 
which the Company furnishes electric service.  It is always necessary to refer to and comply with 
state statutes, local ordinances, and the Company's standard rules and regulations on file with the 
public utility commissions.  To the extent that any included information contradicts any terms in the 
Company’s current applicable tariff, the tariff provision shall govern.  
This information is general and 
does not include every detail or every lawful requirement.   
• The Company shall have the right to refuse to connect any wiring or installation that does not fully 
meet the above requirements, regulations, and rules.  The Company shall also have the right to 
disconnect the wiring or installation of any customer violating any of such requirements, 
regulations, or rules.  This action is not intended to imply that the Company undertakes any 
obligations to inspect the customer's wiring and electrical facilities, to assume any obligations, or to 
make any representations concerning their adequacy, safety, fitness for purpose, or other 
qualification.  Nothing in the above Rules and Regulations or in this Guide shall be construed as 
imposing or undertaking such obligations or representations.   
• All inquiries regarding service requirements should be directed to the Company’s local Engineering 
Services Section.  Inquiries regarding specific meter related requirements can be directed to the 
Company's local Meter Services Section.   
• This Guide is subject to amendment from time to time, and will be re-issued on an as needed basis.  
It is the responsibility of the user to obtain the current version.  The current edition of this Guide 
supersedes all previous issues and instructions.   
• Significant changes to text from the last published version are identified in this document by 
a vertical bar in the outward margin (see example in the right margin).  Changes to the 
exhibits are identified by small triangles pointing to the revisions.  Note: These triangles 
point to changes made to the exhibits on the revision dates shown in the lower right corner 
of the exhibits.  
• If you are looking at a paper copy of this document, the most current edition of this Guide is 
available on the Internet at http://www.firstenergycorp.com
 [From the Home page select the 
appropriate Operating Company from the Drop Down Box and then click on “Go”, next click on the 
“Builder & Contractor” tab.
Comments, corrections, and suggestions regarding this document should be directed to 
FirstEnergy, Energy Delivery Operations Services Department, Distribution Design Standards 
Section at (800) 633-4766.   
November 2009  
2
DEFINITIONS  
Terms frequently used in this Guide are as defined below: 
• ANSI:  American National Standards Institute   
• Application for Service: Application for service is a formal request submitted by the customer to 
the Company stating their desire to obtain electric service at a certain time and location.  
Applications may be processed by e-mail, telephone, or in-person.   
• Class of Service: The characteristics of electric service described in terms of voltage, phase, 
frequency, and number of wires.   
• Clearance: Clearance is a specified minimum distance between two objects (measured surface-to-
surface) to assure adequate space for safety, security, or access.   
• Code: The National Electrical Code (NEC), National Electrical Safety Code (NESC), or other 
electrical codes or regulations in effect in the area served.   
• Company: Refers to the FirstEnergy Operating Companies (FEOC - Ohio Edison, The Illuminating 
Company, Penn Power, Toledo Edison, Jersey Central Power & Light, Penelec, and Met-Ed)   
• Customer: The party using the Company's service, or in applicable cases, the property owner or 
developer or any party working on behalf of the customer such as a contractor or developer.  The 
customer’s electrical equipment is typically governed by the NEC.   
• Customer's Installation: All wiring, conduit, meter socket, service disconnecting devices, 
appliances, lighting, and other equipment installed and/or owned by the customer on the 
customer’s premises for the customer’s use.   
• Distribution Lines: Company lines medium voltage and below typically located in the public right-
of-way in/or along streets, alleys, highways, or on private property for general distribution of electric 
service to customers.   
• High-Leg: On a four-wire, delta-connected system where the midpoint of one phase winding is 
grounded to supply lighting and similar loads, the conductor or busbar having the higher phase 
voltage to ground shall be durably and permanently marked by an outer finish that is orange in 
color or by other effective means.  Such identification shall be placed at each point on the system 
where a connection is made if the grounded conductor is also present.  (Reference NEC 110.15 & 
230.56)  
• Instrument Transformer: Instrument transformer is a high quality transformer that accurately 
reproduces in its secondary circuit, a current or voltage in proportion to the current or voltage in the 
primary circuit.   
• Line Extension: A line extension is any addition to the Company's existing primary distribution 
lines and facilities that must be made to render electric service to a customer.   
• Listed: Equipment, materials, or services included in a list published by an organization that is 
acceptable to the authority having jurisdiction and concerned with evaluation of products or 
services, that maintains periodic inspection of production of listed equipment or materials or 
periodic evaluation of services, and whose listing states that the equipment, material, or services 
either meets appropriate designated standards or has been tested and found suitable for a 
specified purpose.   
November 2009  
3
• Meter: Meter is a device for accurately measuring the electric power and energy consumed by a 
customer.  The meter is supplied and maintained by the Company.   
• Mobile Home: A mobile home is a manufactured home that complies with the mobile home 
definition in the NEC.   
• Point of Service: That point where the Company's conductors or equipment connect to the 
customer’s conductors or equipment of the facility   
• PUC/BPU/PSC: The Public Utilities Commissions (OH, PA) / Board of Public Utilities (NJ) / Public 
Service Commission (NY).   
• Raceway: A raceway is an enclosed channel for holding wires or cables.   
• Service: The conductors and equipment for delivering energy from the Company's electric supply 
system to the wiring system of the premises served.   
• Service Drop: A service drop is the overhead service conductors from the last pole or other aerial 
support to and including the connectors, if any, connecting to the service entrance conductors at 
the building or other structure.   
• Service-Entrance Conductors, Overhead System: The service entrance for an overhead system 
is the group of service conductors between the terminals of the service equipment and a point 
usually outside the building, clear of building walls, where joined by tap or splice to the service 
drop.   
• Service-Entrance Conductors, Underground System: The service entrance for an underground 
system is the group of service conductors between the terminals of the service equipment and the 
point of connection to the Service Lateral.   
• Service Equipment: The necessary equipment, usually consisting of circuit breaker or switch and 
fuses, and their accessories, located near point of entrance of supply conductors to a building and 
intended to constitute the main control and means of cutoff for the supply to that building   
• Service Lateral: The underground service conductors between the street main, including any risers 
at a pole or other structure or from transformers or handholes, and the first point of connection to 
the service entrance conductors in a terminal box, meter or other enclosure with adequate space, 
inside or outside the building wall.   
• Service Territory (electric): Service territory is a defined area in which a given electric utility can 
legally provide service.  The area is governed by a set of agreements and maps on file with the 
appropriate PUC/BPU/PSC.   
• Tariff
: The applicable Company tariff as filed with the New Jersey Board of Public Utilities, the 
Public Utilities Commission of Ohio, the Pennsylvania Public Utility Commission, or the New York 
Public Service Commission.   
• UL: Underwriters Laboratories – an independent product-testing and certification organization  
November 2009  
4
GENERAL INFORMATION  
Availability & Character of Service 
• The information contained in this booklet refers primarily to service requirements at the usual 
voltages for residential and general service installations.  Service requirements for installations 
requiring higher voltages vary according to situation, and are not covered in this booklet except in 
Service at Voltages Greater Than Secondary (Greater Than 600 V)
”.  The Company's rules and 
the rules and regulations, as filed with the PUC/BPU/PSC, shall apply to the installation and use of 
the service furnished.   
• Please ascertain from the Company, well in advance of the date actual service connection is 
required, whether or not service is available in the particular locality in question.  If service is 
available, determine its exact character; that is, the voltage (such as 120/240 V, 208Y/120 V, or 
480Y/277 V), single-phase, three-phase, network, etc., since these characteristics may vary in 
different localities.  A 120-volt two-wire service is no longer available.  These characteristics are 
especially important for the proper operation of motors and other major equipment.  Normally, this 
information will be provided in writing from authorized Company personnel to avoid possible 
misunderstanding.   
• The Company will, if requested, advise and assist present or prospective customers in the selection 
of electrical equipment, facilities, capacitors, protective coordination, and with information 
concerning rates.   
Application for Service
• The customer should make applications for new, additional, or temporary service via the Internet or 
telephone to a Company office; well in advance of the date actual service is required.  After the 
necessary customer information is received, the typical minimum time frames are as follows:  
Residential Service Drop / Lateral 
4 weeks 
Residential Line Extension 
8 weeks 
Commercial/Industrial Drop / Lateral 
10 weeks 
Commercial/Industrial Line Extension 
16 weeks 
These recommendations will allow service to be established as near the desired time as practicable.   
• The following information is required as soon as it is available to the customer.  The Company 
cannot work on your job until the information is provided:  
1. Service address (including nearest intersecting roads),  
2. Lot number (and block number where applicable) and subdivision name,  
3. Tax district name (in PA and NJ),  
4. Contact persons (developer/architect, electrical contractor, etc) names, addresses, mailing 
addresses, and their telephone numbers, 
5. Owner name, address, mailing address, and telephone number, 
6. Person to be billed and the mailing address, 
7. Type of electric service required – overhead (OH) or underground (UG),  
8. Service voltage desired (e.g., 120/240 V single-phase, 208Y/120 V, or 480Y/277 V three-
phase).   
9. Amp rating of the main(s)  
Documents you may be interested
Documents you may be interested