13.3 Importing a Plantview model
To import a Plantview model:
1. Select File --> Import --> CAD... . 
The New Import Model dialog box is displayed.
2. Select Import CAD.
3. Use the default name import model or enter a new name.
4. Click OK.
5. Select the model from the list.
6. Click Properties... to open a dialog box where you can define the settings for the import
file type you selected: 
• On the Conversion tab, enter the conversion file names or browse for the conversion
files.
• On the Parameters tab, enter the name of the Plantview file you want to import in
the Input file box, or use Browse to locate the file.
• Set the file type to Plantview in the Type box, and set the origin coordinates in the
Origin boxes if you want the file in a specific location.
• Set the material grade in the Material box on the SDNF tab.
You can also click ... next to the box, and browse for the material grade in the Select
Material dialog box.
• If you wish to create a report of the import, enter the required information on the
Report tab.
• If you are importing the model for the first time, you do not need to change the
default values on the Advanced tab.
7. Click OK to go to the Import Model dialog box.
8. Click Import
Tekla Structures displays the Import model info dialog box.
9. Select which version of parts to import.
10.Click Accept all
If you have changed the model and want to re-import it, you can also reject all changes
by clicking Reject all, or accept or reject individual changes by clicking Select
individual....
11.Tekla Structures displays the message Do you want to save the import model for
subsequent imports? Click Yes
Tekla Structures displays the imported model in a model view.
CAD
101
Importing a Plantview model
Change font size in pdf text box - Compress reduce PDF size in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
C# Code & .NET API to Compress & Decompress PDF Document
change paper size pdf; pdf compress
Change font size in pdf text box - VB.NET PDF File Compress Library: Compress reduce PDF size in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
VB.NET PDF Document Compression and Decompression Control SDK
adjust pdf page size; pdf file size
12.Right-click the model view and select Fit work area to entire model to ensure that the
imported model is completely visible.
13.If parts are missing, check the View depth Up and Down values in the View Properties
dialog box and change them if necessary.
CAD model import settings on page 103
13.4 Importing a SteelFab/SCIA model
To import a SteelFab/SCIA model:
1. Select File --> Import --> CAD... . 
The Import Models dialog box is displayed.
2. Select Import Steelfab/SCIA from the Type list.
3. Use the default name import model or enter a new name.
4. Click OK.
5. Select the model from the list.
6. Click Properties... to open a dialog box where you can define the settings for the import
file: 
• Enter the input file name.
• Enter the conversion file names.
• Set the origin coordinates in the Origin boxes if you want the file in a specific
location
• Set Import weldings to Yes to include welds in the model.
• Set Import holes to Yes to include holes in the model.
7. Click OK.
8. Click Import.
9. Select which version of parts to import.
10.Click Accept all.
11.If you have changed the model and want to re-import it, you can also reject all changes
by clicking Reject all, or accept or reject individual changes by clicking Select
individual....
12.Tekla Structures displays the message Do you want to save the import model for
subsequent imports? Click Yes
Tekla Structures displays the import model in a model view.
13.Right-click the model view and select Fit work area to entire model to ensure that the
imported model is completely visible.
See also
CAD
102
Importing a SteelFab/SCIA model
C# PDF Text Box Edit Library: add, delete, update PDF text box in
Support to change font color in PDF text box. Ability to change text size in PDF text box. Adding text box is another way to add text to PDF page.
change font size pdf text box; adjust size of pdf
C# PDF Sticky Note Library: add, delete, update PDF note in C#.net
Allow users to add comments online in ASPX webpage. Able to change font size in PDF comment box. Able to save and print sticky notes in PDF file.
reader pdf reduce file size; pdf page size may not be reduced
14.If parts are missing, check the View depth Up and Down values in the View Properties
dialog box and change them if necessary.
CAD model import settings on page 103
13.5 CAD model import settings
The settings related to importing various types of models through the Import Model dialog
box are listed below. All of the tabs and settings are not available for all import types. The
import types are listed next to the settings, so that you can see which import type the
settings belong to. The Import Model dialog box is displayed when you click Properties in
the Import Models or New Import Model dialog box.
Option
Description
Import type
Profile conversion file
Material conversion
file
Twin profile conversion
file
Set the conversion files you want to use.
Conversion files map Tekla Structures profile and
material names with names used in other
software.
For SteelFab/SCIA, these options are located on
the Parameters tab.
CAD
FEM
CIS Model/
CIMSteel
Eureka LMP
MicasPlus
SteelFab/SCIA
Advanced tab
Action when object
status is (compared to)
Previous plan lists the objects in your model,
compared with the objects in the file to be
imported. They can be NewModifiedDeleted, or
Same.
Tekla Structures compares the state of imported
objects with those in your model. They can be Not
in modelDifferent, or Same.
Use the options under Not in model, Different,
and Same to specify the actions when importing
changed objects. The options are No actionCopy,
Modify, or Delete.
CAD
FEM
MicasPlus
Eureka LMP
CIS Model/
CIMSteel
Option
Description
Import type
Part Pos_No
Assembly Pos_No
Enter a prefix and a start position number.
For SDNF, this option is located on the SDNF tab.
FEM
See also
Conversion tab
Parts tab
CAD
103
CAD model import settings
C# PDF Field Edit Library: insert, delete, update pdf form field
Support to change font size in PDF form. RasterEdge.Imaging.Font.dll. pdf"; String outputFilePath = Program.RootPath + "\\" Output.pdf"; List<BaseFormField
adjust size of pdf in preview; pdf custom paper size
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
Support to add text, text box, text field and crop marks to PDF document. Able to edit and change PDF annotation properties such as font size or color.
pdf reduce file size; change font size on pdf text box
Option
Description
Import type
Input file or ASCII file
name
The file you want to import. You can also browse
for the file.
All
Type or
Model type
Set the input file or model type:
CAD: SDNF, Calma, HLI, Plantview, SDNF (PDMS),
XML
FEM: DSTV, SACS, Monorail, Staad, Stan 3d, Bus
CIS Model/CIMSteel: Design, Analysis, SP3D.
CAD
FEM
CIS Model/
CIMSteel
CIS version
Select CIS/1 or CIS/2:
• CIS/1 imports files compatible with the
CIMsteel LPM4DEP1 schema declaration.
• CIS/2 imports files compatible with the
CIMsteel CIS/2
(STRUCTURAL_FRAME_SCHEMA) schema
declaration.
CIS Model/
CIMSteel
Input scope
Import the Entire model or Selection only.
CIS2 status
Part rotation
Select Front or Top.
MicasPlus
Origin X, Y, Z
Set the origin coordinates to place the file in a
specific location.
CAD
FEM
CIS Model
Eureka LPM
MicasPlus
SteelFab/SCIA
Default yield stress
limit
Default material when
yield stress > = limit
Default material when
yield stress < limit
The Default material when yield stress < limit
setting is used for SACS import file. Define the
material to use if yield stress is less than the limit.
The setting Default material when yield stress
>= limit is used for SACS or DSTV import files. For
SACS, this field defines the material to use if yield
stress is greater than or equal to the limit. For
DSTV you can enter the material grade here, if it is
not included in the import file.
FEM
Combine members
Max length for
combining
To combine several elements in the FEM or CIS
model into one part in Tekla Structures, set
Combine members to Yes.
For example, if a beam in a file consist of more
than one element, and you select Yes, the
elements are combined to form one beam in the
Tekla Structures model.
FEM
CIS Model/
CIMSteel
Parameters tab
CAD
104
CAD model import settings
C# PDF insert text Library: insert text into PDF content in C#.net
Powerful .NET PDF edit control allows modify existing scanned PDF text. Ability to change text font, color, size and location and output a new PDF document.
pdf compression settings; pdf page size dimensions
VB.NET PDF insert text library: insert text into PDF content in vb
Save text font, color, size and location changes to Other robust text processing features, like delete and remove PDF text, add PDF text box and field.
change font size pdf document; pdf page size limit
Option
Description
Import type
If you use the value No, Tekla Structures creates a
beam for each element in the FEM or CIS model.
Max length for combining is only applied if you
set Combine members to Yes. Use this setting to
define the maximum length for combining parts.
Tekla Structures combines elements into one part
only if their combined length is less than the
value you enter here.
Ignore offsets
CIS/1 and CIS/2 analysis models can include
member offsets, which means that nodes are not
exactly at the beam’s end points. With the default
Yes, Tekla Structures uses these offsets to locate
the physical members. With No, Tekla Structures
determines the location using the node locations.
CIS/CIMSteel
Ignore forces
Use to define how forces are imported. With No,
Tekla Structures imports absolute values of
maximum forces to parts’ user-defined attributes
ShearTension and Moment. With Yes, Tekla
Structures does not import forces.
CIS/CIMSteel
Import GUID (design
model)
The part GUID is included in the import.
CIS/CIMSteel
Create log file
Select Create to write a new log file and delete
the previous log file each time you import the
model.
Select Append (default) to add the log file
information is at the end of the existing log file.
If you do not need a log file, select No.
In SDNF, this option is on the SDNF tab.
CAD (SDNF)
CIS2 status
Display log file
Select With an external viewer to display the log
file in an external viewer, like Microsoft Notepad.
If you do not want to display the file, select Not
viewed.
Select In a dialog box to create a separate list
dialog box in which the file can only be viewed.
In SDNF, this option is on the SDNF tab.
CAD (SDNF)
CIS2 status
Import weldings
Include weldings in the imported model.
SteelFab/SCIA
Import bolt holes
Include bolt holes in the imported model.
SteelFab/SCIA
Option
Description
Import type
Create report
Set to Yes to create a report.
CAD
FEM
Report tab
CAD
105
CAD model import settings
C# PDF Convert to Word SDK: Convert PDF to Word library in C#.net
PDF document, keeps the elements (like images, tables and chats) of original PDF file and maintains the original text style (including font, size, color, links
pdf font size change; acrobat compress pdf
VB.NET PDF delete text library: delete, remove text from PDF file
Functionality to remove text format by modifying text font, size, color, etc. Other PDF edit functionalities, like add PDF text, add PDF text box and field.
pdf optimized format; change font size pdf form
Option
Description
Import type
Display report
Set to Yes to display the report.
CAD
FEM
Report template
Select the report template.
CAD
FEM
Report file name
Enter the report file name or browse for a report
file.
CAD
FEM
Option
Description
Import type
Part Pos_No
Enter a prefix and a start position number.
This settings relates to the Position number type
setting.
CAD (SDNF)
SDNF version number
Set the SDNF format type to 2.0 or 3.0.
CAD (SDNF)
Apply cuts and fittings Set to Yes (default) to apply cuts and fittings in
the import.
CAD (SDNF)
Consider offsets
Set to Yes to create offsets. In most cases you
should select YesNo (default) positions part
creation points at part end points.
CAD (SDNF)
Log file name
Enter the log file name or browse for an existing
log file.
CAD (SDNF)
Position number type
The SDNF file contains identifiers that can be
included in a part’s user-defined attributes, or
used as part position numbers.
Select Part position if you want the identifier to
become the part’s position number. Do not use
the Pos_No option with this option.
Select Universal ID if you want the identifier to
become a user-defined attribute for the part.
For file imports from PDS or PDMS then the
Universal ID option is the normal case.
To make user-defined attributes visible in the
dialog boxes, you need to add them to the
objects.inp file.
CAD (SDNF)
Option
Description
Import type
Material
Select the material grade.
CAD (Plantview)
FEM (Staad)
Option
Description
Import type
Version
Select the DSTV version.
FEM (DSTV)
SDNF tab
Plantview tab
DSTV tab
CAD
106
CAD model import settings
Option
Description
Import type
Import static elements
Import other elements
If the DSTV file to be imported contains a static
and a CAD model, you can choose which one to
import.
Answering Yes to Import static elements imports
the static model.
Answering Yes to Import other elements imports
the CAD model.
FEM (DSTV)
Option
Description
Import type
Scale
Specify the scale of the import model. You can
import Stan 3d without specifying the scale as
long as both the Tekla Structures model and the
import model are in millimeters. If the Stan 3d file
is in millimeters, use the scale 1. If the Stan 3d
file is in meters, use the scale 1000.
FEM (Stan 3d)
Material
Enter the material for the parts to import.
FEM (Stan 3d)
Option
Description
Import type
Pos_No
Indicate the Pos_No of the girders, columns,
braces and cantilevers you import.
FEM (Bus)
Material
Enter the material for the parts to import.
FEM (Bus)
Name
Enter the name of the parts to import.
FEM (Bus)
Class
Enter the class of the parts to import.
FEM (Bus)
Beams behind plane
The value Yes aligns the tops of all beams at the
floor level.
FEM (Bus)
Option
Description
Import type
Action when object
status is (compared to)
Previous plan lists the objects in your model,
compared with the objects in the file to be
imported. They can be NewModifiedDeleted, or
Same.
Tekla Structures compares the state of imported
objects with those in your model. They can be Not
in modelDifferent, or Same.
Use the options under Not in modelDifferent,
and Same to specify the actions when importing
changed objects. The options are No action, Copy,
Modify, or Delete.
CAD
FEM
MicasPlus
Eureka LMP
CIS Model/
CIMSteel
Importing an SDNF model on page 98
Importing a Plantview model on page 101
Stan 3d
Bus tab
Advanced tab
See also
CAD
107
CAD model import settings
Importing a SteelFab/SCIA model on page 102
13.6 Exporting to CAD
You can export a CAD model in several formats.
To export a CAD model:
1. Open a Tekla Structures model.
2. Click File --> Export --> CAD... to open the CAD export dialog box.
3. Enter the paths to the required conversion files on the Conversion tab.
4. Go to the Parameters tab, and give a name to the export file in the Output file box. 
You can also browse for the file.
5. Select the export format from the Type list.
6. Use the Origin XY, Z boxes to specify the origin of the exported model.
7. In PML export, define PML-specific information on the PML tab.
8. In SDNF, SDNF (PDMS) and PDMS export, go to the SDNF tab, and define the necessary
information.
9. Select the parts in the model to export.
10.Click Apply and Create
Tekla Structures creates the export file in your current model folder.
CAD model export settings on page 108
CAD import and export formats on page 97
13.7 CAD model export settings
Settings related to exporting various types of models through the Export CAD dialog box are
listed below. FEM export settings are also described. All of the tabs and settings are not
available for all export types. The export types are listed next to the settings, so that you can
See also
CAD
108
Exporting to CAD
see which export type the setting belongs to. The Export CAD dialog box is displayed when
you select File --> Export --> CAD... .
Option
Description
Export type
Profile conversion
file
Material conversion
file
Twin profile
conversion file
Set the conversion files you want to use.
Conversion files map Tekla Structures profile and
material names with names used in other
software.
All
Option
Description
Export type
Output file
The file name of the exported file. You can also
browse for the file.
All
Type
Select the export format.
All
Origin X, Y, Z
Set the origin coordinates to place the exported
model in a specific location.
PMLSDNFXML
Split members
Splits a part in the Tekla Structures model into
several elements in the STAAD or DSTV model.
FEM
Combine segmented
members (MicroSAS)
Gives you the option to combine multiple parts to
form one part in the exported model.
For example, if you have divided a beam into
several elements and select the Yes option, Tekla
Structures combines the elements so that they
form one beam in the exported model. With the
option No every element of the beam in the model
forms individual beams.
FEM (MicroSAS)
Option
Description
Export type
Units (for PML only) Select the units for the export model.
PML
Export cut parts
Controls whether cuts are included in the export.
Yes exports part cuts.
When you use PML, enter the Tekla Structures
profile names in the conversion file. This makes
the other software consider parts as beams and
columns, not as plates, and reduces the export file
size.
PML
Option
Description
Export type
SDNF version number Select the SDNF version to be used in the export.
With StruCAD, use SDNF version 2.0.
SDNF
SDNF(PDMS)
PDMS
Conversion tab
Parameters tab
PML tab
SDNF tab
CAD
109
CAD model export settings
Option
Description
Export type
Apply cuts and
fittings
Select Yes (default) applies cuts and fittings in the
export.
SDNF
SDNF(PDMS)
PDMS
Position number type The SDNF file contains identifiers, which can be
included in a part’s user-defined attributes, or as
position numbers. You have the following options:
• Part position
The identifier becomes the part’s position
number. Do not use the Part Pos_No fields
with this option.
• Assembly position
The identifier becomes the assembly’s position
number.
• Universal ID
The identifier becomes a user-defined
attribute for the part.
To make user-defined attributes visible, you need
to add them to the objects.inp file.
SDNF
SDNF(PDMS)
PDMS
Consider offsets
To ignore the offset records during export, select
No, and to take them into account, select Yes.
This setting does not affect the actual start and
end point information, only the offset. Tekla
Structures writes the start and end points based
on the actual solid object, not on the reference
line.
SDNF
SDNF(PDMS)
PDMS
PDMS phase offset
PDMS phase offset defines phase offset for
exported parts. For example, if the first phase in
Tekla Structures model is 1 and you enter 10 for
phase offset, Tekla Structures parts in another
software get the phase from 11 and up.
SDNF
SDNF(PDMS)
PDMS
Engineering firm
Enter the name of the engineering company.
SDNF
SDNF(PDMS)
PDMS
Client
Enter the name of the client.
SDNF
SDNF(PDMS)
PDMS
CAD
110
CAD model export settings
Documents you may be interested