11 / 35
checkboxes).
4. Also turn on Remote clients use Orchestrate's "ImageThenSlewTo" command.
5. Click OK to close the Server Settings window.
6. Now try connecting from your ASCOM astronomy program again. It should work.
Install the ASCOM "TeleAPI" plug-in from here: Download TheSky
TeleAPI plugin
.
1. Start TheSky 6
2. In the Telescope menu, select Setup... TheSky's Telescope Setup window will appear.
3. Set the Telescope or control system name to Telescope API.
4. Click Settings... to display the ASCOM Telescope Chooser
5. Select Temma by Takahashi telescope type in the ASCOM Chooser.
6. Now click Properties in the Chooser. Verify the settings are correct.
7. Click OK in the Chooser.
8. Click Close in Telescope Setup.
9. Now, in TheSky's Telescope menu, select Link/Establish. You should see the crosshairs indicating
your telescope's current position, and you now have telescope control in TheSky.
Created with the Standard Edition of HelpNDoc: Create HTML Help, DOC, PDF and print manuals from 1
single source
Using the Temma Driver with Thesky X
See http://ascom-standards.org/FAQs/Index.htm
Created with the Standard Edition of HelpNDoc: iPhone web sites made easy
Getting help and reporting driver issues
In order of preference potential driver problems can be reported via several methods:
1. Posting a message to the Yahoo Groups forum for Temma mounts: http://tech.groups.yahoo.com/
group/ASCOMTemmaDriver/
2. E-mail to temma@ccdastro.net
.
IMPORTANT: When reporting a potential ASCOM driver bug here are some general guidelines: 
Enable pdf thumbnails in - Draw thumbnail images for PDF in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support Thumbnail Generation with Various Options for Quick PDF Navigation
pdf thumbnail generator online; create thumbnail from pdf c#
Enable pdf thumbnails in - VB.NET PDF Thumbnail Create SDK: Draw thumbnail images for PDF in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Support Thumbnail Generation with Various Options for Quick PDF Navigation
create pdf thumbnail; pdf thumbnail preview
12 / 35
1. The first aim of a bug report is to let us see the failure with our own eyes. Please give us detailed
instructions so that we can make it fail for ourselves.
2. The second aim of a bug report is to describe what went wrong. Describe everything in detail. State
what you saw, and also state what you expected to see. Write down the error messages, especially if
they have numbers in them. Better yet, take a screenshot!
3. By all means try to diagnose the fault yourself if you think you can, but if you do, you should still
report the symptoms as well.
4. Be ready to provide extra information if we need it, like trace logs. 
5. If other programs are involved state the EXACT version number of each program. Usually you can
find this information in the programs Help->About menu item.
6. Write clearly. Say what you mean, and make sure it can't be misinterpreted!
Thank you in advance for following these guidelines! For more details please see this link:
http://www.chiark.greenend.org.uk/~sgtatham/bugs.html
Created with the Standard Edition of HelpNDoc: Free HTML Help documentation generator
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Embedded page thumbnails. outputFilePath = Program.RootPath + "\\" 3_optimized.pdf"; 'create optimizing for Monochrome Image 'to enable dowmsampling for
cannot view pdf thumbnails in; generate pdf thumbnail c#
C# PDF File Compress Library: Compress reduce PDF size in C#.net
Embedded page thumbnails. outputFilePath = Program.RootPath + "\\" 3_optimized.pdf"; // create optimizing Monochrome Image -- // to enable downsampling for
how to view pdf thumbnails in; enable pdf thumbnails
13 / 35
Temma Mount Setup Window
ASCOM Setup
Telescope Setup window:
Note: the Mount Type, Controller, Port, and Use ASCOM Serial Object fields will be disabled if an
ASCOM client program is already connected to the mount. 
If you click the Advanced >>>>>> button you will see additional controls:
Detailed explanations of each field follows in the next sections.
Created with the Standard Edition of HelpNDoc: Generate EPub eBooks with ease
Advanced Features
Created with the Standard Edition of HelpNDoc: Full-featured Documentation generator
GPS
To use the GPS the Temma must not be connected.
Procedure:
1. Your GPS must be set to send data in NMEA format, baud rate 4800.
C# HTML5 PDF Viewer SDK to view, annotate, create and convert PDF
framework class. An advanced PDF editor enable C# users to edit PDF text, image and pages in Visual Studio .NET project. Support to
show pdf thumbnails in; pdf thumbnails
C# HTML5 PDF Viewer SDK deployment on IIS in .NET
and set the “Physical path” to the place where you store XDoc.PDF.HTML5 Viewer Demo. Pool Defaults…" in the right panel, and set the value "Enable 32-Bit
pdf first page thumbnail; thumbnail view in for pdf files
14 / 35
2. Press the 'Link' button to connect to the GPS.
3. Once connected press the 'Send' button to send the GPS time and location to the Temma and
to update your systems computer clock.
4. Press the 'Unlink' button to disconnect the GPS then press 'Exit to return to the setup window.
Created with the Standard Edition of HelpNDoc: Easily create Help documents
Automated Mount Safety
The mount safety features is not a failsafe way to protect your
equipment from damage, and it is not intended to be a substitute
for for good judgment or and attendant at the scope. Please use
with caution. Keep the checkbox checked to disable these
features. 
Setup the Parameters:
note: scope movements started via the Temma's hand paddle
can not be controlled via the driver's mount safety features.
Rules imposed by the driver will only affect slews initiated by the
driver. These features are mainly designed to help avoid crashes
from the telescope tracking in to the mount, tripod, or other
object.
Minimum Allowable Altitude - Input a number representing
degrees in altitude that the mount will stop all movement when it
is reached or exceeded.
Maximum Allowable HA (hourangle) - A positive number
for the maximum HA permitted (e.g. 5.5 = a HA of +/- 5.5
hours from the Meridian). Calculations for declinations other
than 0 will automatically be performed using this input. 
Allowable Tracking Near the Meridian - Enter a number for
the minutes tracking near the Meridian when the scope is West
on the pier and pointing East (e.g. -.5 will stop tracking when
the mount reaches 30 minutes of the Meridian).
When a crash is avoided by these features you must take the
following actions to reinitialize your mount and the Temma
driver:
1. Disconnect the driver
2. Enter the Temma Driver's setup and check the 'Disable
VB.NET PDF - VB.NET HTML5 PDF Viewer Deployment on IIS
and set the “Physical path” to the place where you store XDoc.PDF.HTML5 Viewer Demo. Pool Defaults…" in the right panel, and set the value "Enable 32-Bit
enable thumbnail preview for pdf files; pdf no thumbnail
C# PDF Page Rotate Library: rotate PDF page permanently in C#.net
Enable batch changing PDF page orientation without other PDF reader control. Support to overwrite PDF and save rotation changes to original PDF file.
print pdf thumbnails; create thumbnail jpg from pdf
15 / 35
Mount Safety Limits' checkbox
3. Reconnect to the Mount
4. Move the mount to a safe position
5. Enter the Temma Driver's setup and uncheck the 'Disable
Mount Safety Limits' checkbox
6. Resume
Checking the 'Disable Mount Safety Limits' button will
deactivate this feature.
If you want to be warned before the mount flips check the
'Warn..' button.
Created with the Standard Edition of HelpNDoc: Easy EBook and documentation generator
Initialization
Temma Setup and Initialization Procedure 
1. Turn off the Temma telescope mount. 
2. Connect the RS232 serial port on the Temma to an open serial port on your computer. 
3. Turn the Temma Power switch on. Each time the Temma is powered on, the Temma control
system is initialized with the following default parameter: 
* The optical tube assembly (or telescope) is assumed to be on the West side of the mount. 
* The telescope is pointing to 0.00 in both right ascension and declination. 
* Right ascension and declination correction speeds are set to 90 (unless you have entered a
different rate in the Temma driver's main window). 
* The control system tracking is for the Northern Hemispheret. 
4. Open your planetarium software. 
5. In the 'ASCOM Telescope Chooser Control list, select Temma by Takahashi. 
6. Click Settings and then select the correct COM port and input your info in the other fields
(e.g:. longitude/latitude). 
7. Establish a link to the Temma. 
8. Select one of the orientation modes from the 'Init' windows 
9. When the link is established, center the appropriate star as directed and then synchronize the
planetarium software (e.g.: for TheSky press its 'Sync' button). 
C# Create PDF from OpenOffice to convert odt, odp files to PDF in
with XDoc.PDF SDK. Enable C#.NET Users to Create PDF OpenOffice Document (Odt, Ods, Odp) from PDF with .NET PDF Library in C# Class.
pdf preview thumbnail; view pdf thumbnails in
VB.NET PDF metadata library: add, remove, update PDF metadata in
VB.NET PDF - Read and Write PDF Metadata in VB.NET. Enable VB.NET Users to Read, Write, Edit, Delete and Update PDF Document Metadata in Visual Basic .NET.
pdf thumbnails in; create thumbnails from pdf files
16 / 35
Synchronizing 
Procedure
To synchronize with the
optical tube assembly on the
East side of the mount, Scope
pointing West
1. Loosen the clutches on the mount and move the telescope to the
East side of the mount. 
2. Center a known star that is on the West side of the Meridian in
the field of view. 
3. Identify the star in your planetarium software. 
4. Sync on the star. 
5. An on screen dialog will notify you of the correct side of the
meridian to select the sync star. 
To synchronize with the
optical tube assembly on the
West side of the mount,
Scope pointing East
1. Loosen the clutches on the mount and move the telescope to the
West side of the mount. 
2. Center a known star that is on the East side of the Meridian in
the field of view. 
3. identify the star in your planetarium software. 
4. Sync on the star. 
5. An on screen dialog will notify you of the correct side of the
meridian to select the sync star. 
Scope Pointed at Pole,
Counter-weight down
position
This method is intended for remote users. The CW down method gives a
rough initial alignment that must be refined by a subsequent sync for
accurate GOTO operations. It is recommended that the subsequent sync
be accomplished using ACP (Pinpoint) to plate solve a CCD image after
the initial alignment. Obviously, a manual/visual sync can be used if
desired.
Scope Pointed at Pole,
Counter-weight West
The CW West method gives a rough initial alignment that must be refined
by a subsequent sync for accurate GOTO operations. Place the CW on
the West side of mount with the CW shaft and OTA parallel to the
ground.
Keep Last Sync
The Temma telescope was previously synced and not powered off, or
VB.NET PDF Text Extract Library: extract text content from PDF
Enable extracting PDF text to another PDF file, and other formats such as TXT and SVG form. OCR text from scanned PDF by working with XImage.OCR SDK.
no pdf thumbnails in; how to make a thumbnail of a pdf
C# PDF Text Extract Library: extract text content from PDF file in
Enable extracting PDF text to another PDF file, TXT and SVG formats. Support extracting OCR text from PDF by working with XImage.OCR SDK.
can't view pdf thumbnails; generate thumbnail from pdf
17 / 35
the Temma was 'Parked'
SyncZ
New feature: 'Sync Z' allows the user to initialize and accurately sync the
mount in the Takahashi 'pointed at the Zenith' position. To use this
feature first turn off tracking, point the scope at the Zenith (using a level
helps position the scope accurately), then click the 'Sync Z' button. 
* power on the mount
* start the driver and turn off tracking
* polar align
* move the scope manually to point to Zenith (use a level for best
results)
* press SyncZ and the mount starts with RA=sidereal time and
Dec=Latitude
Created with the Standard Edition of HelpNDoc: Easily create HTML Help documents
Mount Configuration
Mount Type: Select the
mount type that matches
your mount. 
Created with the Standard Edition of HelpNDoc: Free EBook and documentation generator
Offset Scale
Displays the proper offset for the polar scope based on the users site.
Created with the Standard Edition of HelpNDoc: Easy EBook and documentation generator
18 / 35
Site Setup
Site Setup
Latitude: Latitude of the
selected site.Latitude must
be in degrees: minutes:
seconds format.
Longitude: Longitude of
the selected site.
Longitude must be in
degrees: minutes: seconds
format.
Elevation: Elevation in
meters
To get Longitude/Latitude
from TheSky: clicking the
button will retrieve the
longitude and latitude from
Thesky (check the 'X' box
if you are using Thesky X).
The Longitude/Latitude
fields will be populated
with the data from
Thesky's site data . 
Created with the Standard Edition of HelpNDoc: Produce electronic books easily
Telescope
19 / 35
Aperture: Enter the
primary telescope's
aperture in millimeters.
Focal Length: Enter the
primary telescope's focal
length in millimeters.
Note: these fields are not
specifically used by the
driver but they are passed
up to clients if the client
asks for them.
Created with the Standard Edition of HelpNDoc: Free HTML Help documentation generator
20 / 35
Temma Handbox Window
Temma Handbox
Clicking the 'More' buttons will expose additional handbox
features.
The 'Always Show' checkbox , when checked,' will make
the handbox visible on connection to the Temma. If
unchecked the handbox will remain minimized in the tray
until called.
Created with the Standard Edition of HelpNDoc: Easily create PDF Help documents
Flip Mount
CAUTION!
Please use care and common sense when flipping the mount or using the Meridian
Delay feature to ensure that your telescope equipment will not strike your pier.
Care is needed when slewing to objects on the 'wrong' side of the mount.  Please test your equipment
Documents you may be interested
Documents you may be interested