c# : winform : pdf viewer : Add page number pdf file SDK application API .net windows wpf sharepoint RS_SigGen_NFC_A_B_F_Operating_en_055-part1449

User Interface
NFC A/B/F
51
Operating Manual 1175.7268.02 ─ 05
4.7 Trigger/Marker/Clock Settings
The trigger, clock, and marker delay functions are available for R&S SMx and R&S
AMU instruments only.
To access this dialog select "Main dialog > Trigger/Marker".
The "Trigger In" section allows setting of the trigger for the signal. Various parameters
will be provided for the settings, this depends on which trigger source - internal or
external - is selected. The current status of signal generation ("Running" or "Stopped")
is indicated for all trigger modes.
The "Marker Mode" section is where the marker signals at the MARKER output con-
nectors are configured.
In the "Marker Delay" section you can define the marker signal delay, either without
restriction or restricted to the dynamic section, i.e., the section in which it is possible to
make settings without restarting signal and marker generation.
Trigger/Marker/Clock Settings
Add page number pdf file - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add pages to pdf document; add page number to pdf document
Add page number pdf file - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add page numbers to pdf reader; add pdf pages to word
User Interface
NFC A/B/F
52
Operating Manual 1175.7268.02 ─ 05
In the "Clock Settings" section you can select the clock source and - in case of an
external source - the clock type.
The buttons in the last section lead to subsection for general trigger, clock and map-
ping settings.
4.7.1 Trigger Settings
The trigger, clock, and marker delay functions are available for R&S SMx and R&S
AMU instruments only.
In the "Trigger in" dialog the trigger for the signal is set. Various parameters will be pro-
vided for the settings, this depends on which trigger source - internal or external - is
selected. The current status of signal generation ("Running" or "Stopped") is indicated
for all trigger modes.
Trigger Mode
Selects trigger mode, i.e. determines the effect of a trigger event on the signal genera-
tion.
"Auto"
The signal is generated continuously.
"Retrigger"
The signal is generated continuously. A trigger event (internal or external) causes a
restart.
"Armed_Auto"
The signal is generated only when a trigger event occurs. Then the signal is gener-
ated continuously.
An "Arm" stops the signal generation. A subsequent trigger event (internal with or
external) causes a restart.
"Armed_Retrigger"
The signal is generated only when a trigger event occurs. Then the signal is gener-
ated continuously. Every subsequent trigger event causes a restart.
An "Arm" stops signal generation. A subsequent trigger event (internal with or
external) causes a restart.
"Single"
Trigger/Marker/Clock Settings
C# PDF File Split Library: Split, seperate PDF into multiple files
If your page number is set as 1, then the two output PDF files will contains the first page and the later three pages Add necessary references:
add blank page to pdf; add remove pages from pdf
VB.NET PDF File Split Library: Split, seperate PDF into multiple
can split target multi-page PDF document file to one-page PDF files or PDF file to smaller PDF documents by every given number of pages Add necessary references
adding page numbers to pdf files; add page numbers to a pdf
User Interface
NFC A/B/F
53
Operating Manual 1175.7268.02 ─ 05
The signal is generated only when a trigger event occurs. Then the signal is gener-
ated once to the length specified at "Signal Duration".
Every subsequent trigger event (internal or external) causes a restart.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC[:​TRIGger]:​SEQuence​ on page 105
Signal Duration Unit
Available in Single Trigger Mode. Defines the unit for describing the length of the signal
sequence to be output.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​SLUNit​ on page 105
Signal Duration
Enters the length of the signal sequence to be output in the "Single" trigger mode.
Use this parameter to deliberately output part of the signal, an exact sequence of the
signal, or a defined number of repetitions of the signal.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​SLENgth​ on page 104
Running/Stopped
For enabled modulation, displays the status of signal generation for all trigger modes.
"Running"
The signal is generated; a trigger was (internally or externally) initiated in triggered
mode.
"Stopped"
The signal is not generated and the instrument waits for a trigger event.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​RMODe?​ on page 104
Arm
For trigger modes "Armed Auto" and "Armed Retrigger", stops the signal generation
until subsequent trigger event occurs.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​ARM:​EXECute​ on page 103
Execute Trigger
Available only with internal trigger source and a trigger mode other than "Auto". Exe-
cutes the trigger manually.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​EXECute​ on page 103
Trigger Source
Selects trigger source. This setting is effective when a trigger mode other than "Auto"
has been selected.
"Internal"
The trigger event is executed by "Execute Trigger".
Trigger/Marker/Clock Settings
C# PDF insert text Library: insert text into PDF content in C#.net
pageIndex, The page index of the PDF page that will be 0
adding a page to a pdf file; add page to pdf without acrobat
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF users to do multiple manipulations on PDF file and page Please note that, PDF page number starts from
adding pages to a pdf document; add and remove pages from pdf file online
User Interface
NFC A/B/F
54
Operating Manual 1175.7268.02 ─ 05
"Internal (Baseband A/B)"
(two-path instruments)
The trigger event is the trigger signal from the second path
"External (Trigger 1/2)"
The trigger event is the active edge of an external trigger signal, supplied at the
TRIGGER 1/2 connector.
Use the "Global Trigger/Clock Settings" dialog to define the polarity, the trigger
threshold and the input impedance of the trigger signal.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​SOURce​ on page 105
Sync. Output to External Trigger
(enabled for Trigger Source External)
Enables/disables output of the signal synchronous to the external trigger event.
For R&S SMBV instruments:
For two or more R&S SMBVs configured to work in a master-slave mode for synchro-
nous signal generation, configure this parameter depending on the provided system
trigger event and the properties of the output signal. See below for an overview of the
required settings.
Typical Applications
● All instruments are synchronous to the external trigger event
– System Trigger = common External Trigger event for the master and the slave
instruments
– "Sync. Output to External Trigger" = ON
● All instruments are synchronous among themselves but starting the signal from first
symbol is more important than synchronicity with external trigger event
– System Trigger = common External Trigger event for the master and the slave
instruments
– "Sync. Output to External Trigger" = OFF
● All instruments are synchronous among themselves
– System Trigger = internal trigger signal of the master R&S SMBV for the slave
instruments
– "Sync. Output to External Trigger" = OFF
Trigger/Marker/Clock Settings
C# PDF Text Search Library: search text inside PDF file in C#.net
Add necessary references: Description: Search specified string from all the PDF pages. eg: The first page is 0. 0
add a page to a pdf document; adding page numbers to pdf
C# PDF delete text Library: delete, remove text from PDF file in
Add necessary references: RasterEdge.Imaging.Basic.dll. matchString, The string wil be deleted from PDF file, -. 0
adding pages to a pdf document in preview; add multi page pdf to word document
User Interface
NFC A/B/F
55
Operating Manual 1175.7268.02 ─ 05
"On"
Corresponds to the default state of this parameter.
The signal calculation starts simultaneously with the external trigger
event but because of the instrument’s processing time the first sam-
ples are cut off and no signal is output. After elapsing of the internal
processing time, the output signal is synchronous to the trigger event.
"Off"
The signal output begins after elapsing of the processing time and
starts with sample 0, i.e. the complete signal is output.
This mode is recommended for triggering of short signal sequences
with signal duration comparable with the processing time of the
instrument.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​EXTernal:​SYNChronize:​OUTPut​
on page 104
Trigger Delay / External Delay
Delays the trigger event of the signal from:
● the external trigger source
● the other path
Use this setting to:
synchronize the instrument with the device under test (DUT) or other external devi-
ces
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger[:​EXTernal<ch>]:​DELay​ on page 103
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OBASeband:​DELay​ on page 104
Trigger/Marker/Clock Settings
C# PDF Text Highlight Library: add, delete, update PDF text
200F); annot.EndPoint = new PointF(300F, 400F); // add annotation to The string wil be highlighted from PDF file, 0
adding pages to a pdf; add or remove pages from pdf
C# Word - Split Word Document in C#.NET
your page number is set as 1, then the two output Word files will contains the first page and the later three pages respectively. C# DLLs: Split Word File. Add
add page numbers pdf file; add page pdf reader
User Interface
NFC A/B/F
56
Operating Manual 1175.7268.02 ─ 05
Trigger Inhibit / External Inhibit
Sets the duration for inhibiting a new trigger event subsequent to triggering. The input
is to be expressed in samples.
In the "Retrigger" mode, every trigger signal causes signal generation to restart. This
restart is inhibited for the specified number of samples.
This parameter is only available on external triggering or on internal triggering via the
second path.
For two-path instruments, the trigger inhibit can be set separately for each of the two
paths.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger[:​EXTernal<ch>]:​INHibit​ on page 103
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OBASeband:​INHibit​ on page 104
4.7.2 Marker Settings
The marker output signal for synchronizing external instruments is configured in the
marker settings section "Marker Mode".
The R&S SMBV supports only two markers.
4.7.2.1 Marker Mode Settings
Marker Mode
Selects a marker signal for the associated "MARKER" output.
"Trigger"
Marker singal, generated on received internal or external trigger sig-
nal.
"Restart"
A marker signal is generated on every repetition of the complete
frame sequence.
"Pulse"
A regular marker signal is generated. The frequency is derived by
dividing the sample rate by the divider. The input box for the divider
opens when "Pulse" is selected, the resulting pulse frequency is dis-
played below it.
"Pattern"
A marker signal that is defined by a bit pattern is generated. The pat-
tern has a maximum length of 64 bits and is defined in an input field
which opens when pattern is selected.
Trigger/Marker/Clock Settings
User Interface
NFC A/B/F
57
Operating Manual 1175.7268.02 ─ 05
"ON/OFF
Ratio"
A regular marker signal that is defined by an ON/OFF ratio is gener-
ated. A period lasts one ON and OFF cycle.
The "ON Time" and "OFF Time" are each expressed as a number of
samples and are set in an input field which opens when ON/OFF ratio
is selected.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​MODE​ on page 106
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​PULSe:​DIVider​ on page 107
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​PULSe:​FREQuency?​
on page 108
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​PATTern​ on page 107
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​ONTime​ on page 107
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​OFFTime​ on page 107
4.7.2.2 Marker Delay Settings
The delay of the signals on the marker outputs is set in the "Marker Delay" section.
The trigger, clock, and marker delay functions are available for R&S SMx and R&S
AMU instruments only.
The R&S SMBV supports two markers.
Marker x Delay
Enters the delay between the marker signal at the marker outputs and the start of the
signal.
If the setting "Fix marker delay to dynamic range" is enabled, the setting range is
restricted to the dynamic range. In this range the delay of the marker signals can be
set without restarting the marker and signal.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​DELay​ on page 108
Current Range without Calculation
Displays the dynamic range within which the delay of the marker signals can be set
without restarting the marker and signal.
The delay can be defined by moving the setting mark.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​DELay:​MINimum?​ on page 109
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut<ch>:​DELay:​MAXimum?​ on page 108
Trigger/Marker/Clock Settings
User Interface
NFC A/B/F
58
Operating Manual 1175.7268.02 ─ 05
Fix Marker to Current Range
Restricts the marker delay setting range to the dynamic range. In this range the delay
can be set without restarting the marker and signal.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​TRIGger:​OUTPut:​DELay:​FIXed​ on page 108
4.7.3 Clock Settings
The clock settings are used to set the clock source.
The trigger, clock, and marker delay functions are available for R&S SMx and R&S
AMU instruments only.
Sync. Mode
(for R&S SMBV only)
Selects the synchronization mode.
This parameter is used to enable generation of very precise synchronous signals of
several connected R&S SMBVs.
Note: If several instruments are connected, the connecting cables from the master
instrument to the slave one and between each two consecutive slave instruments must
have the same length and type. Avoid unnecessary cable length and branching points.
● "None"
The instrument is working in stand-alone mode.
● "Sync. Master"
The instrument provides all connected instruments with its synchronisation (includ-
ing the trigger signal) and reference clock signal.
● "Sync. Slave"
The instrument receives the synchronisation and reference clock signal from
another instrument working in a master mode.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​CLOCk:​SYNChronization:​MODE​ on page 110
Set Synchronization Settings
(for R&S SMBV only)
Performs an automatic adjustment of the instrument's settings required for the synchro-
nization mode, selected with the parameter "Synchronization Mode".
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​CLOCk:​SYNChronization:​EXECute​ on page 110
Clock Source
Selects the clock source.
● "Internal"
The internal clock reference is used to generate the symbol clock.
● "External"
Trigger/Marker/Clock Settings
User Interface
NFC A/B/F
59
Operating Manual 1175.7268.02 ─ 05
The external clock reference is fed in as the symbol clock or multiple thereof via the
CLOCK connector.
The symbol rate must be correctly set to an accuracy of +/-2 % (see data sheet).
The polarity of the clock input can be changed with the aid of "Global Trigger/Clock
Settings".
In the case of two-path instruments this selection applies to path A.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​CLOCk:​SOURce​ on page 110
Clock Mode
Enters the type of externally supplied clock.
"Chip"
A chip clock is supplied via the CLOCK connector.
"Multiple"
A multiple of the chip clock is supplied via the CLOCK connector; the symbol clock
is derived internally from this.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​CLOCk:​MODE​ on page 109
Chip Clock Multiplier
Enters the multiplication factor for clock type Multiple.
Remote command: 
[:​SOURce<hw>]:​BB:​NFC:​CLOCk:​MULTiplier​ on page 109
Measured External Clock
Provided for permanent monitoring of the enabled and externally supplied clock signal.
Remote command: 
CLOCk:INPut:FREQuency?
4.7.4 Global Settings
The buttons in this section lead to dialogs for general trigger, clock and mapping set-
tings.
These settings are available for R&S SMx and R&S AMU instruments only.
Global Trigger/Clock Settings
Calls the "Global Trigger/Clock/Input Settings" dialog.
This dialog is used among other things for setting the trigger threshold, the input impe-
dance and the polarity of the clock and trigger inputs.
In the case of two-path instruments, these settings are valid for both paths.
The parameters in this dialog affect all digital modulations and standards, and are
described in chapter "Global Trigger/Clock/Input Settings" in the Operating Manual.
User Marker / AUX I/O Settings
Calls the "User Marker AUX I/O Settings" dialog, used to map the connector on the
rear of the instruments.
Trigger/Marker/Clock Settings
User Interface
NFC A/B/F
60
Operating Manual 1175.7268.02 ─ 05
See also "User Marker / AUX I/O Settings" in the Operating Manual.