• Cancel: the action is cancelled. You will return to the measurement 
project without saving the data. 
Add page numbers to pdf using preview - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add a page to a pdf; add page numbers pdf
Add page numbers to pdf using preview - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
adding a page to a pdf document; add pdf pages to word
QUADERA HTML Help 
132 
Offset Parameters 
The calibration project displays the parameters required to determine the offset. 
Modified parameters are forwarded to the device and take effect in the next 
measurement task. 
Offset parameters QMG220 
Parameter 
Range 
Description 
• E-05 
… 
E-12 
(not editable) 
Offset value for the corresponding 
measuring range of the detector. 
The device automatically 
determines the values listed in the 
corresponding table. 
See also recipe parameter 
"Amplifier Range". 
• Offset 
Mass 
0 <= value 
<= MaxRange 
Mass for the offset measurement. 
• Delete 
Offset 
Entries 
Button 
Deletes the offset values for the 
detector. 
Offset parameters QMG700 
Parameter 
Range 
Description 
• E-05 
… 
E-12 
(not editable) 
Offset value for the corresponding 
measuring range of the selected 
detector. 
The device automatically 
determines the values listed in the 
corresponding table. 
See also recipe parameter 
"Amplifier Range". 
• Electrometer 
Preamplifier 
Dropdown list 
Detector type for the offset 
determination. 
• Faraday, 
• SEM 
• Offset Mass 
0 <= value 
<= 
MaxRange 
Mass for the offset measurement. 
C# Create PDF Library SDK to convert PDF from other file formats
them the ability to count the page numbers of generated PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text
adding page numbers to pdf documents; add page numbers to pdf preview
C# PowerPoint - PowerPoint Creating in C#.NET
them the ability to count the page numbers of generated a PowerPoint document in C#.NET using this PowerPoint creating toolkit, if you need to add some text
add pages to pdf in preview; add page to a pdf
QUADERA 
133 
• Delete 
Offset 
Entries 
Button 
Deletes the offset values for the 
detector that is selected in 
"Electrometer Preamplifier". 
C# Word - Word Creating in C#.NET
offer them the ability to count the page numbers of generated creating a Word document in C#.NET using this Word creating toolkit, if you need to add some text
add page break to pdf; add blank page to pdf
C# Word - Word Create or Build in C#.NET
also offer them the ability to count the page numbers of generated using this Word document adding control, you can add some additional Create Word From PDF.
add a page to a pdf in acrobat; add and remove pages from a pdf
QUADERA HTML Help 
134 
Tuning the RF Generator 
Tuning the RF Generator 
Basics 
The high frequency voltage of the RF generator (QMH, or RF22x for QMG220, see 
device settings) is applied to the rod pairs of the QMG to separate ions. The 
output resonant circuit of the generator has to be matched to the QMG rod 
system in the following cases: 
• when commissioning the device, 
• problems appear when masses near the upper mass scale limit are 
measured. 
Procedure 
Tuning the RF generator requires to turn the tuning screw. The calibration project 
in QUADERA® is used to display and check the tuning voltage. 
NOTE: 
Use the device specific instructions (OEM manual) when tuning the RF 
generator. 
• Tuning the RF generator for the QMG220, 
• Tuning the RF generator for the QMG700. 
C# Excel - Excel Creating in C#.NET
also offer them the ability to count the page numbers of generated a Excel document in C#.NET using this Excel creating toolkit, if you need to add some text
add page numbers to pdf document; add page numbers to a pdf file
QUADERA 
135 
Minimizing the Tuning Voltage (QMG220) 
This topic applies to the QMG220. 
NOTE: 
Use the device specific instructions (OEM manual) when tuning the RF 
generator. 
1. Open the start page: In the View menu, click Show Start Page
2. Click on the icon for the required device. 
3. Create a new calibration project: In the "Calibration and Tuning" list, 
double-click RF Tuning.qmt. This way you create a new calibration 
project based on the selected template. 
4. The new measurement project window appears. The working area displays 
the calibration project. Note: 
• No recipe is assigned to this calibration project. Thus, no user specific 
adaptation is available. 
• An actual measurement is not performed, i.e. you can not start and 
stop the measurement. 
5. Proceed as follows to tune the output resonant circuit of the generator: 
• Observe the signal bar in the working area. It displays the actual 
generator tuning voltage. The two drag indicators show the maximum 
and minimum achieved voltage. 
• Use the Reset Arrows command of the context menu "Chart" to reset 
the two drag indicators. 
• Adjust the tuning screw of the generator to minimize the tuning 
voltage. Refer to the OEM manual. The tuning voltage should not 
exceed half of the maximum signal. 
NOTE: 
Do not damage the tuning screw of the generator. Never tighten or 
remove the tuning screw. 
6. Close and save the measurement project. In the File menu, click Close
You are requested if you want to save the measurement project. 
QUADERA® suggests an automatically generated file name that is based 
on date/time of the measurement and the used template. 
• Yes: the "Save As" window used for saving measuring data opens up. 
Select a suitable name and path and then click Save. The 
measurement project will be saved and closed. 
Please note: The file extension for measurement projects is *.qmp 
• No (recommended option): the measurement project will be closed 
without saving the data. 
• Cancel: the action is cancelled. You will return to the measurement 
project without saving the data. 
QUADERA HTML Help 
136 
Extended context menu "Chart" 
In the calibration project "RF Tuning" the context menu "Chart" 
provides an additional command: 
• Reset 
Arrows 
Reset the drag indicators that show the 
maximum and minimum achieved tuning 
voltage. 
QUADERA 
137 
Minimizing the Tuning Voltage (QMG700) 
This topic applies to the QMG700. 
NOTE: 
Use the device specific instructions (OEM manual) when tuning the RF 
generator. 
1. Open the start page: In the View menu, click Show Start Page
2. Click on the icon for the required device. 
3. Create a new calibration project: In the "Calibration and Tuning" list, 
double-click RF Tuning.qmt. This way you create a new calibration 
project based on the selected template. 
4. The new measurement project window appears. The working area displays 
the calibration project. Note: 
• No recipe is assigned to this calibration project. Thus, no user specific 
adaptation is available. 
• An actual measurement is not performed, i.e. you can not start and 
stop the measurement. 
5. The QMH is set to the maximum mass number. Tune the output resonant 
circuit as described in the instructions of the RF generator. 
NOTE: 
Do not damage the tuning screw of the generator. Never tighten or 
remove the tuning screw. 
6. Close and save the measurement project. In the File menu, click Close
You are requested if you want to save the measurement project. 
QUADERA® suggests an automatically generated file name that is based 
on date/time of the measurement and the used template. 
• Yes: the "Save As" window used for saving measuring data opens up. 
Select a suitable name and path and then click Save. The 
measurement project will be saved and closed. 
Please note: The file extension for measurement projects is *.qmp 
• No (recommended option): the measurement project will be closed 
without saving the data. 
• Cancel: the action is cancelled. You will return to the measurement 
project without saving the data. 
QUADERA HTML Help 
138 
Background Determination 
Background Determination 
Basics 
The mass spectrometer background is caused by residual gases. These gases are 
present in every analysis chamber and do not originate from the measuring 
sample. The background is mainly constant if the measuring apparatus is well 
conditioned. However, measurement results may be distorted if the background 
is not considered properly. The background determination identifies the existing 
residual gases. The detected ion currents are subtracted from subsequent 
measurement projects. The result will show the true composition of the 
measuring gas. 
Procedure 
Residual gases are measured either with the gas inlet closed or by using a zero 
gas, i.e. a pure gas that is fed into the analysis chamber to reach the same 
pressure as expected for future measurements. Using a zero gas takes account of 
adsorption and desorption effects better than pumping down the chamber to final 
vacuum. 
An MID measurement is used to determine the background. The recipe 
parameters are defined in the corresponding calibration project. Use the recipe 
editor to change the parameters. You can determine the mass spectrometer 
background for each detector type separately and store the results in the 
Background Library. The stored values will be used in future MID and MCD 
measurement projects where they are subtracted from the measured signals. 
NOTE: 
Always pump down the chamber to final vacuum before performing the 
background determination, or let in a suitable zero gas. Otherwise, 
serious measurement errors may result. 
QUADERA 
139 
Measuring the Background 
NOTE: 
Before starting the measurement, check the correct calibration of the 
mass spectrometer components. If a calibration is necessary, perform 
the following preparatory measurements: 
• Calibrate the mass scale, 
• Determine the offset. 
1. Feed a suitable zero gas into the vacuum chamber, or pump the chamber 
down to final vacuum. 
2. Open the start page: In the View menu, click Show Start Page
3. Click on the icon for the required device. 
4. Create a new calibration project: In the "Templates" list, double-click e.g. 
Background Determination.qmt. This way you create a new calibration 
project based on the selected template. You can modify it according to 
your needs. 
5. The new measurement project window appears. The working area displays 
the calibration project. 
• Edit the recipe according to your needs (if necessary): Click the 
corresponding tab in the working area selection. 
The measurement tasks must not contain mass numbers where peaks 
of the zero gas appear. 
• Display the measuring data: Click the corresponding tab in the working 
area selection. 
NOTE: 
You can start the measurement regardless whether the recipe editor or 
the working area has been selected. 
6. Start the measurement: In the device status view, click on the "Start" 
icon. The connection to the device is automatically established. The device 
now receives the parameters for the current measurement task. The 
measurement is running automatically. 
7. Check the measured values, e.g. display the measuring data in a table. 
8. Click Apply to Background Library to forward the background 
measurement to the Background Library. Note: 
• New background measurements (mass numbers) are added to the 
Background Library, 
• Current measuring values replace existing data sets in the Background 
Library. 
9. Close and save the measurement project. In the File menu, click Close
You are requested if you want to save the measurement project. 
QUADERA HTML Help 
140 
QUADERA® suggests an automatically generated file name that is based 
on date/time of the measurement and the used template. 
• Yes: the "Save As" window used for saving measuring data opens up. 
Select a suitable name and path and then click Save. The 
measurement project will be saved and closed. 
Please note: The file extension for measurement projects is *.qmp 
• No (recommended option): the measurement project will be closed 
without saving the data. 
• Cancel: the action is cancelled. You will return to the measurement 
project without saving the data. 
NOTE: 
The data sets in the Background Library will be subtracted in MID and 
MCD measurements. If you wish to skip this subtraction then reset the 
data sets in the Background Library ("Delete Background Library" 
button). 