The channel and scale coupling is set in two independent panels. 
• Decouple All assigns independent channel or scale settings to all traces in the Trace Manager. If 
the channel and trace names include numbers, the trace with the lowest number is assigned to 
the channel with the lowest number and so forth. Measurement or data traces and their 
associated memory traces are assigned to the same channel. 
• Couple All assigns all traces to the channel or scale settings selected in the corresponding drop-
down lists. All channel or scale settings except the selected ones are lost. The analyzer displays a 
confirmation dialog box before deleting the unused channels.        
Remote control: 
–     
Sort Table 
Changes the order of the traces (table rows) in the Trace Manager dialog. 
• The drop-down list contains all trace properties that can provide the sorting criterion. The 
properties correspond to the column headers in the Trace Manager.  
• The two radio buttons qualify whether the traces in the table are sorted in ascending or 
descending order, according to the property selected in the pull-down list.    
Remote control: 
No command, display configuration only.     
Trace Statistics     
Opens a submenu to evaluate and display statistical and phase information of the entire trace or of a 
specific evaluation range and calculate the x-dB compression point. 
Add page to pdf preview - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
adding page numbers in pdf; add page number to pdf file
Add page to pdf preview - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add pages to pdf acrobat; add pages to pdf without acrobat
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
122 
• Min/Max/Pk-Pk displays or hides the essential statistical parameters of the trace in the selected 
evaluation range  
• Phase Delay/El Length displays or hides the phase delay and the electrical length of the trace in 
the selected evaluation range (Eval Range...).  
• Mean/Std Dev displays or hides the arithmetic mean value and the standard deviation of the trace 
in the selected evaluation range  
• RMS displays or hides the RMS value of the trace in the selected evaluation range. 
• Eval Range... opens a dialog to define the range for the statistical and phase evaluation and for 
the compression point measurement.   
• Compression Point starts the x-dB compression point evaluation  
• Define Compression Value... sets the compression level (x dB).  
Statistical Evaluation 
The Min/Max/Pk-PkMean/Std Dev, and RMS commands in the Trace Statistics submenu display or hide 
the maximum (Max), minimum (Min), the peak-to-peak value (Pk-Pk), arithmetic mean value (Mean), the 
standard deviation (Std Dev), and the RMS value of all response values of the trace in the selected 
evaluation range (Eval Range...). 
Definition of statistical quantities 
The statistical quantities are calculated from all response values in the selected evaluation range. 
Suppose that the trace in the evaluation range contains n stimulus values x
i
and n corresponding 
response values y
i
(measurement points). 
C# WinForms Viewer: Load, View, Convert, Annotate and Edit PDF
PDF Annotation. • Add sticky notes to PDF document in preview. Add text to PDF document in preview. • Add text box to PDF file in preview.
add page to pdf online; add and delete pages in pdf online
C# WPF Viewer: Load, View, Convert, Annotate and Edit PDF
This page will mainly let you know: PDF Annotation. • Add sticky notes to PDF document. • Highlight PDF text in preview. • Add text to PDF document.
add blank page to pdf preview; add page numbers to pdf using preview
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
123 
• Mean is the arithmetic mean value of all response values:  
• Std. Deviation is the standard deviation of all response values:  
• Max. and Min. are the largest and the smallest of all response values y
i
.  
•  RMS is the root mean square (effective value) of all response values: 
• P-P is the peak-to-peak value and is equal to the difference Max. – Min. 
The definitions given above apply to all linear, scalar trace formats. For a dB Mag trace, the Mean, 
Std. Dev. and RMS are calculated before logarithmation.  
Remote control: 
CALCulate<Chn>:STATistics[:STATe] 
CALCulate<Chn>:STATistics:RESult? MIN | MAX | PEAK2P | MEAN | 
STDDev 
RMS 
CALCulate<Chn>:STATistics:MMPTpeak[:STATe] 
CALCulate<Chn>:STATistics:MSTDev[:STATe] 
CALCulate<Chn>:STATistics:RMS[:STATe] 
Phase Delay/El. Length 
Displays or hides the phase delay (Phs Dly) and the electrical length (El Len) of the trace in the selected 
evaluation range (Eval Range...). The parameters are only available for trace formats that contain phase 
information, i.e. for the formats  Phase, Unwrapped Phase, and the polar diagram formats Polar, Smith, 
Inverted Smith. Moreover, the sweep type must be a frequency sweep. 
Definition of phase parameters 
The phase parameters are obtained from an approximation to the derivative of the phase with respect to 
frequency in the selected evaluation range.  
• Delay is the phase delay, which is an approximation to the group delay and calculated as follows: 
,  
where ∆f is the width of the evaluation range and ∆Φ is the corresponding phase change. See 
also note on transmission and reflection parameters below.  
• EL is the electrical length, which is product of the phase delay times the speed of light in the 
How to C#: Preview Document Content Using XDoc.Word
RasterEdge XDoc.Word provide you with APIs to get a thumbnail bitmap of the first page in the word document file. C# DLLs for Word File Preview. Add references:
add page numbers to pdf in reader; add page to pdf preview
How to C#: Preview Document Content Using XDoc.PowerPoint
APIs to get a thumbnail bitmap of the first page in the C# DLLs: Preview PowerPoint Document. Add necessary XDoc.PowerPoint DLL libraries into your created C#
add pages to pdf in preview; add pages to pdf reader
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
124 
vacuum.   
If no dispersion occurs the phase delay is equal to the group delay. For more information see 
mathematical relations.  
If a dispersive connector type (i.e. a waveguide; see Offset Model dialog) is assigned to a test port related 
to a particular quantity, then the dispersion effects of the connector are taken into account for the 
calculation of the phase delay and the electrical length.  
To account for the propagation in both directions, the delay and the electrical length of a 
reflection parameter is only half the delay and the electrical length of a transmission 
parameter. The formula for PD above is for transmission parameters. See also introduction to 
section Channel – Offset.   
The phase parameters are available only if the evaluation range contains at least 3 
measurement points.  
The phase evaluation can cause misleading results if the evaluation range contains a 
360 
deg phase jump. The trace format Unwrapped Phase avoids this behavior. 
Remote control: 
CALCulate<Chn>:STATistics[:STATe] 
CALCulate<Chn>:STATistics:RESult? 
ELENgth 
PDELay 
CALCulate<Chn>:STATistics:EPDelay[:STATe] 
Compression Point 
Displays or hides all results related to the x-dB compression point of the trace, where x is the selected 
compression value. To obtain a valid compression point results, a power sweep must be active, the trace 
format must be dB Mag and either an S-parameter or a ratio must be measured.  
Compression point 
The x-dB compression point of an S-parameter or ratio is the stimulus signal level where the magnitude of 
the measured quantity has dropped by x dB compared to its value at small stimulus signal levels (small-
signal value). As an approximation for the small-signal value, the analyzer uses the value at the start level 
of the evaluation range (Eval Range...)  
The compression point is a measure for the upper edge of the linearity range of a DUT. It is close to the 
highest input signal level for which the DUT shows a linear response (|a
n
| —> x*|a
n
|b
n
| —> 
C# PDF insert image Library: insert images into PDF in C#.net, ASP
How to insert and add image, picture, digital photo, scanned signature or logo into PDF document page in C#.NET class application?
add page number to pdf preview; adding page numbers to pdf in preview
VB.NET PDF File Compress Library: Compress reduce PDF size in vb.
Remove bookmarks, annotations, watermark, page labels and article threads from PDF while compressing. Also a preview component enables compressing and
add page numbers pdf; add a page to a pdf online
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
125 
x*|b
n
|, so that the magnitude of all S-parameters remains constant).  
When Compression Point is activated, a marker labeled Cmp is placed to compression point with the 
smallest stimulus level. Moreover the Trace Statistics info field shows the numerical results of the 
compression point measurement:  
• Cmp In is the stimulus level at the compression point in units of dBm. 
• Cmp Out is the magnitude of the wave reflected or transmitted by the DUT. If an S-parameter S
ij
is 
measured, then Cmp Out is the magnitude of the wave b
i
.  
• The ratio Cmp Out / Cmp In (in the example above: –14 dB) is equal to the magnitude of the 
measured S-parameter or ratio at the compression point.  
The info field shows invalid results ('---') if the wrong sweep type, trace format or measured quantity is 
selected, or if the trace contains no x-dB compression points in the selected evaluation range.  
Remote control: 
CALCulate:STATistics:NLINear:COMP:RESult? 
Define Compression Value 
Opens the numeric entry bar to define the compression value x (in dB) for the compression point 
measurement.  
Remote control: 
CALCulate:STATistics:NLINear:COMP:LEVel 
Eval Range 
Opens a dialog to define the range for the statistical and phase evaluation and for the x-dB compression 
point measurement. The evaluation range is a continuous interval of the sweep variable. 
It is possible to select, define and display up to ten different evaluation ranges for each setup. Full Span 
means that the search range is equal to the sweep rangeThe statistical and phase evaluation and the 
compression point measurement take into account all measurement points with stimulus values x
i
between the Start and Stop value of the evaluation range: 
Start 
x
Stop 
VB.NET PDF insert image library: insert images into PDF in vb.net
inserting image to PDF in preview without adobe provide users the most individualized PDF page image inserting function, allowing developers to add and insert
add page numbers pdf file; add page numbers to a pdf
How to C#: Preview Document Content Using XDoc.excel
you with APIs to get a thumbnail bitmap of the first page in the C# DLLs: Preview Excel Document without Microsoft Office Installed. Add necessary references:
add page numbers to pdf document; adding page to pdf in preview
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
126 
The evaluation ranges are identical to the marker search ranges. For more information see 
Search Range Dialog.  
Remote control: 
CALCulate<Chn>:STATistics:DOMain:USER 
<numeric_value> 
CALCulate<Chn>:STATistics:DOMain:USER:STARt <numeric_value> 
CALCulate<Chn>:STATistics:DOMain:USER:STOP <numeric_value> 
Smoothing On 
Activates the smoothing function for the active trace, which may be a data or a memory trace. With active 
smoothing function, each measurement point is replaced by the arithmetic mean value of all measurement 
points located in a symmetric interval centered on the stimulus value. The width of the smoothing interval 
is referred to as the Smoothing Aperture and can be adjusted according to the properties of the trace.  
The sweep average is an alternative method of compensating for random effects on the trace 
by averaging consecutive traces. Compared to smoothing, the sweep average requires a 
longer measurement time but does not have the drawback of averaging out quick variations 
of the measured values.  
Remote control: 
CALCulate<Chn>:SMOothing[:STATe] <Boolean> 
Smoothing Aperture  
Defines how many measurement points are averaged to smooth the trace if smoothing is switched on. 
The Smoothing Aperture is entered as a percentage of the total sweep span.   
An aperture of n % means that the smoothing interval for each sweep point i with stimulus value x
i
is equal 
to [x
i
– span*n/200, x
i
+ span*n/200], and that the result of i is replaced by the arithmetic mean value of all 
measurement points in this interval. The average is calculated for every measurement point. Smoothing 
does not significantly increase the measurement time.  
Finding the appropriate aperture  
A large smoothing aperture enhances the smoothing effect but may also average out quick variations of 
the measured values and thus produce misleading results. To avoid errors, observe the following 
recommendations.  
• Start with a small aperture and increase it only as long as you are certain that the trace is still 
correctly reproduced.  
• As a general rule, the smoothing aperture should be small compared to the width of the observed 
structures (e.g. the resonance peaks of a filter). If necessary, restrict the sweep range or switch 
smoothing off to analyze narrow structures.  
Remote control: 
CALCulate<Chn>:SMOothing:APERture <numeric_value> 
C# PDF insert text Library: insert text into PDF content in C#.net
Able to add a single text character and text string formatted text and plain text to PDF page using .NET Supports adding text to PDF in preview without adobe
add blank page to pdf; add multi page pdf to word document
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
127 
Import/Export Data     
Stores one or several data or memory traces to a file or loads a memory trace from a file. Import or export 
is selected from a submenu: 
• Import Data... calls up an Open File dialog to load a memory trace from a trace file.  
• Export Data... calls up a Save As... dialog to store data or memory traces to a trace file.  
Import Data...  
Calls up a dialog to load a memory trace from a trace file. Trace files are ASCII files with selectable file 
format.  
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
128 
The loaded trace data is used to generate a memory trace which is coupled to the active data trace. 
Import Data corresponds to a standard Open File dialog with an additional checkbox:  
• Import Data to New Mem qualifies whether the loaded data overwrite the active memory trace 
(box unchecked, analogous to Data -> Mem) or whether they are used to generate a new memory 
trace (box checked, analogous to Data -> New Mem).   
Trace file import and import conditions 
On loading data from a trace file, the analyzer displays a list box to select one of the traces stored in the 
file. The example below shows a Touchstone (*.s2p) file, containing all four 2-port S-parameters; see 
Trace File Formats.  
Coupling between the imported memory trace and the active data trace implies that the stimulus values of 
the imported data and of the active trace must be compatible. Compatibility means that the Sweep Type of 
the two traces must match; the position and number of the sweep points do not have to be the same.  
The analyzer checks for compatibility before importing data. The Select Parameter box remains empty if 
the selected files contains no compatible data.  
When a *.s1p file is opened the Select Parameter box indicates the 1-port (reflection) 
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
129 
parameter S11, irrespective of the actual S-parameter stored in the file.   
To import a trace file (*.snp or *.csv) you can also use the Windows Explorer and simply 
double-click the file or drag and drop the file into the NWA application. The imported data 
generates a memory trace which is coupled to the active data trace.  
Remote control: 
MMEMory:LOAD:TRACe "<trc_name>","<file_name>" 
Export Data...  
Calls up a dialog to store data or memory traces to a trace file. Trace files are ASCII files with selectable 
file format.  
Data export can serve many purposes, e.g.:  
• To process and evaluate measurement data in an external application.  
• To store measurement data and re-import it in a future measurement session.  
Export Complex Data corresponds to a standard Save As... dialog with an additional panel to specify the 
export optionsThe export options are remembered when the dialog is closed. The Dec. Separator export 
option is not available for Matlab (*.dat) file export. Touchstone files *.s<n>p contain either a single trace 
(*.s1p) or the complete set of S-parameters of an n-port and use the point as Dec. Separator; see Trace 
File Formats.  
• Output Format
selects the format for the exported trace data. In the Real-Imag format, 
each complex measurement value is represented by its real and imaginary part. It is 
also possible to store the linear magnitude and phase (Lin Mag-Phase) or dB 
magnitude and phase (dB Mag-Phase) of each value.  
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
130 
• Content
selects only the Active Trace or All Traces of (the) Active Channel (including 
all data and memory traces) for data export to an ASCII (*csv) file.  
• Dec. Separator
selects either the Point or the Comma (if needed to process the 
exported data with an external application) as a separator for decimal numbers 
exported to an ASCII (*.csv) file.  
• Ask to Overwrite
activates a message box to be displayed before an older trace file with 
the same file name and directory is overwritten.  
Selecting an appropriate file format 
Use a Touchstone file format to export a fixed number of S-parameter data traces to a file that can be 
evaluated with applications such as Agilent's Microwave Design System (MDS) and Advanced Design 
System (ADS). The data must be acquired in a frequency sweep.  
• *.s1p files are intended for a 1-port S-parameter (the reflection coefficient S11) but can be used as 
well to store any single S-parameter. Note that any S-parameter will be labeled S11 in the file and 
in the Select Parameter box.   
• *.s<n>p files (<n> = 2, 3,, 4) are intended for a complete set of <n>-port S-parameters. Data 
export fails if the active channel does not contain the full set of <n>
2
traces. 
Use the ASCII (*.csv) format if you want to do one of the following:  
• Import the created file into a spreadsheet application such as Microsoft Excel.  
• Export an arbitrary number of traces, multiple traces with the same parameter or memory traces.  
• Use export options.  
Use a the Matlab (*.dat) format if you want to import and process the trace data in Matlab. 
For more information see Trace File Formats. 
Remote control: 
MMEMory:STORe:TRACe "<trc_name>","<file_name>"[,UNFormatted] 