c# free pdf viewer : Add page numbers to pdf SDK application service wpf html winforms dnn R&S%20ZVL-MANUAL14-part735

R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
141 
It is possible to define up to ten different target values for each trace and assign them to the markers no. 1 
to 10. The input fields in the Target Search dialog are used to select the markers and define the 
associated search ranges:  
• Marker 
selects one of the ten markers that can be assigned to the trace. If a selected 
marker does not exist, it is created as soon as On is checked. A created marker is 
displayed in the center of the search range.  
• Value 
selects the target value to be assigned to the selected marker. The target Value 
is entered with the unit of the active trace.   
Remote control: 
CALCulate<Chn>:MARKer<Mk>:TARget 
Search Range... 
Opens the Search Range Dialog to confine the target search to a subrange of the sweep.   
Bandfilter     
Opens a submenu to search for trace segments with a bandpass or bandstop shape and determine 
characteristic filter parameters.  
Bandfilter search and filter parameters 
Bandpass and bandstop regions can be described with the same parameter set:  
• A bandpass region contains a local maximum around which the magnitude of the trace falls off by 
more than a specified x dB Bandwidth 
• A bandstop region contains a local minimum around which the magnitude of the trace increases 
by more than a specified x dB Bandwidth.   
The analyzer locates bandpass and bandstop regions and determines their position (Center frequency) 
and shape (Bandwidth, LBE, UBE, Quality factor Q; see Show Results). For a meaningful definition of the 
x dB Bandwidth criterion, the trace format must be dB Mag.  
Add page numbers to pdf - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
adding page numbers to pdf in; add page number to pdf in preview
Add page numbers to pdf - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
adding a page to a pdf; add page number pdf file
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
142 
• Bandpass Search activates the search for a bandpass region in the active trace, starting at the 
absolute maximum of the active trace within the search range.  
• Bandstop Search activates the search for a bandstop region in the active trace, starting at the 
absolute minimum of the active trace within the search range.   
• Bandfilter Tracking causes the bandfilter search to be repeated after each sweep.   
• Level... sets the level defining the filter bandwidth.   
• Search Range... confines the search to a subrange of the sweep.  
• Search Result Off hides the display of the bandfilter parameters in the diagram area.  
• Bandpass Search Ref to Marker activates the search for a bandpass region in the active trace, 
starting at the position of the active marker.  
Bandfilter mode can be selected for a broad range of measured quantities (Trace – Measure), 
provided that the display format is dB Mag. To obtain real filter parameters, the measured quantity 
must be a transmission S-parameter and a frequency sweep must be performed. For other 
quantities (e.g reflection parameters), the Bandfilter functions are still useful to analyze general 
trace properties. In some display formats (e.g. Phase) the bandfilter search is disabled.  
Bandpass Search 
Activates the search for a bandpass region on the active trace and activates bandfilter Tracking. A 
bandpass region is the tallest peak in the search range with a minimum excursion specified by means of 
the x dB Bandwidth parameter.  
When Bandpass Search is activated the analyzer uses (or creates) the four markers Mkr 1 to Mkr 4 to 
locate the bandpass region:  
C# Create PDF Library SDK to convert PDF from other file formats
them the ability to count the page numbers of generated PDF document in C#.NET using this PDF document creating toolkit, if you need to add some text
adding a page to a pdf in reader; add page to pdf in preview
C# Word - Word Create or Build in C#.NET
also offer them the ability to count the page numbers of generated using this Word document adding control, you can add some additional Create Word From PDF.
adding page numbers pdf file; add contents page to pdf
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
143 
• Mkr 1 indicates the maximum of the peak.  
• Mkr 2 indicates the point on the left edge of the peak where the trace value is equal to the 
maximum minus x dB Bandwidth. 
• Mkr 3 indicates the point on the right edge of the peak where the trace value is equal to the 
maximum minus x dB Bandwidth. 
• Mkr 4 indicates the center of the peak, calculated as the arithmetic mean value of the LBE and 
UBE positions. 
For a symmetric peak, the positions of Max and Center coincide.  
The band filter search results are displayed in the bandfilter info field.  
To search for a bandpass region in the vicinity of the active marker, use Bandpass Search Ref to 
Marker. 
Remote control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE 
BPASs 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute BFILter  
Bandstop Search 
Activates the search for a bandstop region on the active trace and activates bandfilter Tracking. A 
bandstop region is the lowest peak (local minimum) in the search range with a minimum excursion that is 
specified by means of the x dB Bandwidth parameter.  
When Bandstop Search is activated the analyzer uses (or creates) the four markers Mkr 1 to Mkr 4 to 
locate the bandstop region:  
C# PowerPoint - PowerPoint Creating in C#.NET
file but also offer them the ability to count the page numbers of generated NET using this PowerPoint document creating toolkit, if you need to add some text
adding pages to a pdf document; add page number to pdf print
C# Word - Word Creating in C#.NET
document file but also offer them the ability to count the page numbers of generated using this Word document creating toolkit, if you need to add some text
add page numbers to pdf document in preview; adding page numbers to pdf in reader
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
144 
• Mkr 1 indicates the minimum of the peak.  
• Mkr 2 indicates the point on the left edge of the peak where the trace value is equal to the 
minimum plus x dB Bandwidth. 
• Mkr 3 indicates the point on the right edge of the peak where the trace value is equal to the 
minimum plus x dB Bandwidth. 
• Mkr 4 indicates the center of the peak, calculated as the arithmetic mean value of the LBE and 
UBE positions. 
For a symmetric peak, the positions of Max and Center coincide.  
The band filter search results are displayed in the bandfilter info field.  
Remote control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE 
BSTOP 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute BFILter 
Bandfilter Tracking 
Causes the bandfilter search to be repeated after each sweep: When tracking mode is active the markers 
typically change their horizontal and their vertical positions as the measurement goes on.   
Tracking for the different bandfilter search modes is enabled or disabled in a selection box. Selecting a 
search mode for tracking also activates this mode.   
Tracking is a toggle function: Selecting the function repeatedly switches the tracking mode on and off.   
Remote control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute 
BFILter 
CALCulate<Chn>:MARKer<Mk>:SEARch:TRACking 
VB.NET TIFF: VB.NET Sample Codes to Sort TIFF File with .NET
manipulating multi-page TIFF (Tagged Image File), PDF, Microsoft Office If you want to add barcode into a TIFF a multi-page TIFF file with page numbers using VB
adding page numbers to pdf documents; add page number to pdf hyperlink
C# Excel: Create and Draw Linear and 2D Barcodes on Excel Page
can also load document like PDF, TIFF, Word get the first page BasePage page = doc.GetPage REImage barcodeImage = linearBarcode.ToImage(); // add barcode image
adding page numbers to pdf; adding page numbers pdf
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
145 
Level 
Opens the numeric entry bar for the minimum excursion of the bandpass and bandstop peaks.  
• A bandpass peak must fall off on both sides by the specified x dB Bandwidth to be considered a 
valid peak.  
• A bandstop peak must increase on both sides by the specified x dB Bandwidth to be considered a 
valid peak.  
Remote control: 
CALCulate<Chn>:MARKer<Mk>:BWIDth <Level> 
Search Range... 
Opens the Search Range Dialog to confine the bandfilter search to a subrange of the sweep.   
It is possible to define and store up to ten different search ranges for each trace. The bandfilter search is 
performed using the markers Mkr 1, ..., Mkr 4, irrespective of the selected search range.   
• Search Range 
Selects a search range for the bandfilter search. Full Span means that 
the search range is equal to the sweep range. Besides, it is possible to store up to 10 
customized search ranges.    
• Start 
defines the beginning of the search range. Start must be smaller than the Stop 
value, otherwise the search will not be initiated.  
• Stop 
defines the end of the search range. Stop must be larger than the Start value, 
otherwise the search will not be initiated.  
• Range Limit Lines On 
displays two vertical lines indicating the Start and the Stop value 
of the current bandfilter search range in the diagram area. This function is enabled as 
soon as one of the search ranges 1 to 10 is selected.  
Search range properties 
In contrast to the marker properties defined in the Marker and Search menus, the ten search ranges are 
valid for the entire setup. This means that, once defined, each of them can be used for any trace in the 
setup, irrespective of the channel that the trace belongs to.  
The default search range of each new marker is Full Span. The analyzer provides greatest flexibility in 
defining search ranges. In particular, two search ranges may overlap or even be identical. The search is 
C# Excel - Excel Creating in C#.NET
document file but also offer them the ability to count the page numbers of generated using this Excel document creating toolkit, if you need to add some text
add pages to pdf preview; add page numbers to pdf reader
VB.NET Image: Guide to Convert Images to Stream with DocImage SDK
Follow this guiding page to learn how to easily convert a single image or numbers of it an image processing component which can enable developers to add a wide
adding a page to a pdf document; add page numbers to a pdf document
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
146 
confined to the part of the search range that belongs to the sweep range.  
The following example shows how search ranges can be used to search a trace for several bandpass 
regions.  
Remote 
control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP 
Search Result Off 
Hides the info field with the results of a bandpass or a bandstop search and disables bandfiter Tracking. 
The info field is displayed again (and tracking re-enabled) when a new bandfilter search is performed.   
Bandfilter parameters 
The info field contains the following search results:   
• Bandwidth is the n-dB bandwidth of the bandpass/bandstop region, where n is the selected x dB 
Bandwidth. The bandwidth is equal to the difference between the Upper Bandwidth Edge (UBE) 
and the Lower Bandwidth Edge (LBE).   
• Center is the stimulus frequency where the trace reaches its absolute maximum (minimum) within 
the bandpass (bandstop) region.  
• Lower Band Edge is the closest frequency below the center frequency where the trace is equal to 
the center value minus n dB  
• Upper Band Edge is the closest frequency above the center frequency where the trace is equal to 
the center value minus n dB 
• The Quality Factor is the ratio between the Center frequency and the 3-dB Bandwidth; it does not 
depend on the selected x dB Bandwidth.  
• Loss is the loss of the filter at its center frequency and is equal to the response value of marker 
C#: Use XImage.OCR to Recognize MICR E-13B, OCR-A, OCR-B Fonts
may need to scan and get check characters like numbers and codes. page.RecSettings. LanguagesEnabled.Add(Language.Other); page.RecSettings.OtherLanguage
adding pages to a pdf; add document to pdf pages
C# Word: How to Use C# Code to Print Word Document for .NET
are also available within C# Word Printer Add-on , like pages at one paper, setting the page copy numbers to be C# Class Code to Print Certain Page(s) of Word.
adding page numbers to pdf files; add pages to pdf online
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
147 
no. 4. For an ideal bandpass filter the loss is zero (0 dB), for an ideal bandstop filter it is –
dB.  
Remote 
control: 
CALCulate<Chn>:MARKer<Mk>:BWIDth? 
CALCulate<Chn>:MARKer<Mk>SEARch:BFILter:RESult[:STATe] 
Bandpass Search Ref to Marker 
Activates the search for a bandpass region on the active trace and activates bandfilter Tracking, starting at 
the position of the active marker. A bandpass region is the closest peak in the search range with a 
minimum excursion specified by means of the x dB Bandwidth parameter.  
In contrast to a Bandpass Search Ref to Max, the Bandpass Search Ref to Marker does not change the 
position of the active markers. The band filter search results are displayed in the bandfilter info field.   
To search for a bandstop region in the vicinity of the active marker, use Bandfilter Tracking – 
Bandstop Search Ref to Marker. 
Remote control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE BPRMarker | 
BSRMarker  
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute BFILter  
Def Peak 
Opens a dialog to define the peak type to be searched for.  
It is possible to select the peak type up to ten times for each trace and assign the selection to the markers 
no. 1 to 10.  
• Marker 
Selects one of the ten markers that can be assigned to the trace. If a selected 
marker does not exist, it is created as soon as On is checked. A created marker is 
displayed in the center of the search range.  
The radio buttons in the Peak Type panel offer the following alternative peak types:  
• Local Max
activates the peak search for local maxima only. The response value at a 
local maximum is larger than the values in the vicinity.  
• Local Min
activates the peak search for local minima only. The response value at a 
local minimum is smaller than the values in the vicinity.  
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
148 
• Local Min or Max
activates the peak search for both local maxima and minima.  
Search Range     
Opens the Search Range Dialog to confine the minimum/maximum search to a subrange of the sweep.   
Search Range Dialog 
Defines search ranges for the maximum/minimum or target search.  
It is possible to define up to ten different search ranges for each setup and assign them to the markers no. 
1 to 10. The input fields in the Search Range dialog are used to select the markers and define the 
associated search ranges:  
• Marker 
Selects one of the ten markers that can be assigned to a trace in the current 
setup. If a selected marker does not exist, it is created as soon as On is checked. A 
created marker is displayed in the center of the search range.  
• Search Range 
Selects the search range to be assigned to the selected marker. Full 
Span means that the search range is equal to the sweep range. Besides, it is possible 
to store up to 10 customized search ranges.    
• Start 
defines the beginning of the search range. Start must be smaller than the Stop 
value, otherwise the search will not be initiated.  
• Stop 
defines the end of the search range. Stop must be larger than the Start value, 
otherwise the search will not be initiated.  
• Range Limit Lines On 
displays two vertical lines indicating the Start and the Stop value 
of the current search range in the diagram area. This function is enabled as soon as 
one of the search ranges 1 to 10 is selected.  
Search range properties 
In contrast to the marker properties defined in the Marker and Search menus, the ten search ranges are 
valid for the entire setup. This means that, once defined, each of them can be assigned to any marker in 
the setup, irrespective of the trace and channel that the marker belongs to.  
The default search range of each new marker is Full Span. The analyzer provides the greatest flexibility in 
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
149 
defining search ranges. In particular, two search ranges may overlap or even be identical. The search is 
confined to the part of the search range that belongs to the sweep range.  
The following example shows how search ranges can be used to search a trace for several local maxima.  
Use the paste marker list for convenient entry of Start and Stop values.  
Remote 
control: 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP 
Marker Tracking 
Causes the active minimum/maximum or target search of the active marker to be repeated after each 
sweep: When tracking mode is active the marker typically changes its horizontal and its vertical position 
as the measurement goes on.   
Tracking mode properties 
The tracking mode is available for all search modes, i.e. for minimum/maximum search, target search and 
bandfilter search. The Marker Tracking function in the Search submenu is valid for an active 
minimum/maximum and target search; bandfilter tracking can be activated separately. Tracking is marker-
specific but can be switched on for several markers simultaneously.  
Switching between Max Search and Min Search does not affect the tracking mode.Tracking is switched off 
though when one of the following actions is performed: 
• Redefinition of the active marker position by means of the functions in the Marker menu or drag-
and-drop of the active marker symbol.  
• Change of the active marker's search mode, e.g. from a minimum/maximum search to a target 
search.   
Tracking is a toggle function: Selecting the function repeatedly switches the tracking mode on and off.   
Remote control: 
CALCulate<Chn>:MARKer<Mk>:SEARch:TRACking 
R&S
®
ZVL 
GUI Reference 
Trace Menu 
Operating Manual 1303.6580.32-01 
150 
Marker     
The functions in the Marker menu are used to position markers on a trace, configure their properties and 
select the format of the numerical readout.   
Markers 
Markers are tools for selecting points on the trace and for numerical readout of measured data. A marker 
is displayed with a symbol (a triangle, a crossbar or a line) on the trace, which may be a data trace or a 
memory trace. At the same time, the coordinates are displayed in a marker info field or in a table. Each 
marker can be defined as a normal marker, reference marker, delta marker or discrete marker.  
Marker types 
• A (normal) marker(Mkr 1, Mkr 2, ...) determines the coordinates of a measurement point on the 
trace. Up to 10 different normal markers can be assigned to a trace.  
• A reference marker(Ref) defines the reference value for all delta markers.  
• A delta marker(
indicates the coordinates relative to the reference marker.  
• The stimulus value of a discrete marker always coincides with a sweep point. 
A special set of markers Mk1 to Mkr4 is provided for bandfilter search mode. 
The most common tasks to be performed with markers can be achieved using the Marker menu functions: 
• Determine the coordinates of a measurement point on the trace. In polar diagrams where no x-
axis is displayed, markers can be used to retrieve the stimulus value of specific points.  
• Determine the difference between two trace points or the relative measurement result (Delta 
Mode).  
• Convert a complex measurement result into other formats.  
Markers also play an important role in performing the following advanced tasks:   
• Change the sweep range and the diagram scale (Marker Funct.).  
• Search for specific points on the trace (Search).  
Documents you may be interested
Documents you may be interested