c# free pdf viewer : Adding a page to a pdf document SDK Library service wpf asp.net azure dnn R&S%20ZVL-MANUAL3-part752

R&S
®
ZVL 
Preparing for Use 
Connecting External Accessories 
Quick Start Guide 1303.6538.62-01 
31 
TIP 
Keyboard configuration  
Use the Start – Control Panel – Keyboard or Regional and Language Options menu of 
Windows XP to configure the keyboard properties. To access Windows XP, you need 
an external keyboard; see Accessing Window XP's Start Menu.   
Operating the analyzer does not require a keyboard. You can access all essential 
functions using the keys on the front panel. In combination with a mouse, the front 
panel keys provide access to all instrument functions.  
1.6.3 Connecting a Printer 
A printer can be connected to one of the Universal Serial Bus connectors on the front 
panel. 
It is safe to connect or disconnect the printer during the measurement. When printing a 
copy (PRINT), the analyzer checks whether a printer is connected and turned on and 
whether the appropriate printer driver is installed. If required, printer driver installation 
is initiated using Windows XP's Add Printer Wizard. The wizard is self-explanatory. A 
printer driver needs to be installed only once, even though the printer may be 
temporarily removed from the analyzer.  
Printer driver installation 
A great variety of printer drivers is available on the analyzer. To obtain the complete 
list, access Windows XP (press the Windows key) and open the Add Printer Wizard in 
the Start – Control Panel – Printer and Faxes menu. 
You can load updated and improved driver versions or new drivers from an installation 
disk, USB memory stick or another external storage medium. Alternatively, if the 
analyzer is integrated in a network, you can install driver data stored in a network 
directory. In either case, use the Add Printer Wizard to complete the installation.   
TIP 
Printer configuration  
Use the Page Setup dialog or the Start  Control Panel – Printers and Faxes menu of 
Windows XP to configure the printer properties. To access Windows XP, you need an 
external keyboard; see Accessing Window XP's Start Menu.  
Adding a page to a pdf document - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
adding page numbers to pdf in preview; adding page numbers in pdf
Adding a page to a pdf document - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add page numbers to pdf document in preview; add and remove pages from a pdf
R&S
®
ZVL 
Preparing for Use 
Connecting External Accessories 
Quick Start Guide 1303.6538.62-01 
32 
1.6.4 Connecting a LAN Cable 
A LAN cable can be connected to the LAN connector on the rear panel of the analyzer.  
To establish a LAN connection proceed as follows:  
1. Refer to section Assigning an IP Address and learn how to avoid connection errors. 
2. Connect an appropriate LAN cable to the LAN port. Use a commercial RJ-45 cable 
to establish a non-dedicated network connection, or a cross-over RJ-45 cable to 
establish a dedicated connection between the analyzer and a single PC.    
Dedicated vs. non-dedicated network connections 
There are two methods to establish a LAN connection of the analyzer:  
A non-dedicated network (Ethernet) connection from the analyzer to an existing 
network made with an ordinary RJ-45 network cable. The analyzer is assigned 
an IP address and can coexist with a computer and with other hosts on the 
same network.  
A dedicated network connection between the analyzer and a single computer 
made with a cross-over RJ-45 network cable. The computer must be equipped 
with a network adapter and is directly connected to the analyzer. The use of 
hubs, switches, or gateways is not needed, however, data transfer is still made 
using the TCP/IP protocol.  
The IP address information is displayed in the Info – Setup Info dialog. 
VB.NET PDF File & Page Process Library SDK for vb.net, ASP.NET
page, you will find detailed guidance on creating, loading, merge and splitting PDF pages and Files, adding a page into PDF document, deleting unnecessary page
add a page to pdf file; add pdf pages together
VB.NET PDF Library SDK to view, edit, convert, process PDF file
Perform annotation capabilities to mark, draw, and visualize objects on PDF document page. Capable of adding PDF file navigation features to your VB.NET program
adding page numbers to pdf in; add page numbers to a pdf document
R&S
®
ZVL 
Preparing for Use 
Remote Control in a LAN 
Quick Start Guide 1303.6538.62-01 
33 
1.7 Remote Control in a LAN 
A LAN connection is used to integrate the analyzer into a home/company network. This 
offers several applications:  
Transfer data between a controller and the analyzer, e.g. in order run a remote 
control program.  
Control the measurement from a remote computer using the Remote Desktop 
application.   
Use external network devices (e.g. printers).  
ATTENTION 
Virus protection  
An efficient virus protection is a prerequisite for secure operation in the network. 
Never connect your analyzer to an unprotected network because this may cause 
damage to the instrument software.  
To establish the connection proceed as follows: 
1. Access Windows XP using an external keyboard; see Accessing Window XP's 
Start Menu.  
2. Open Windows XP's control panel.  
3. Select System and open the Remote tab in the System Properties dialog. Enable 
Allow users to connect remotely to this computer.  
4. Assign an IP address to the analyzer following the directions below and connect 
the analyzer to the network as described in Connecting a LAN Cable 
5. Create a Remote Desktop Connection using the analyzer's IP address.  
NOTE 
Password protection  
The analyzer uses a user name and password as credentials for remote access. In 
the factory configuration, instrument is preset for both the user name and the 
password. To protect the analyzer from unauthorized access, it is recommended to 
change the factory setting.  
1.7.1 Assigning an IP Address 
Depending on the network capacities, the TCP/IP address information for the analyzer 
can be obtained in different ways.   
If the network supports dynamic TCP/IP configuration using the Dynamic Host 
Configuration Protocol (DHCP), all address information can be assigned 
automatically.   
If the network does not support DHCP, or if the analyzer is set to use alternate 
TCP/IP configuration, the addresses must be set manually.   
C# PDF insert image Library: insert images into PDF in C#.net, ASP
image adding library control for PDF document, you can easily and quickly add an image, picture or logo to any position of specified PDF document file page.
add remove pages from pdf; add pages to pdf document
C# PDF insert text Library: insert text into PDF content in C#.net
C#.NET PDF SDK - Insert Text to PDF Document in C#.NET. Providing C# Demo Code for Adding and Inserting Text to PDF File Page with .NET PDF Library.
add pages to pdf; add page number to pdf hyperlink
R&S
®
ZVL 
Preparing for Use 
Remote Control in a LAN 
Quick Start Guide 1303.6538.62-01 
34 
By default, the analyzer is configured to use dynamic TCP/IP configuration and obtain 
all address information automatically. This means that it is safe to establish a physical 
connection to the LAN without any previous analyzer configuration.  
ATTENTION 
Address selection  
If your network does not support DHCP, or if you choose to disable dynamic TCP/IP 
configuration, you must assign valid address information before connecting the 
analyzer to the LAN. Contact your network administrator to obtain a valid IP address, 
because connection errors can affect the entire network. 
Manual TCP/IP configuration 
To disable dynamic TCP/IP configuration and enter the TCP/IP address information 
manually proceed as follows:  
1. Obtain the IP address and subnet mask for the analyzer and the IP address for the 
local default gateway from your network administrator. If needed, also obtain the 
name of your DNS domain and the IP addresses of the DNS and WINS servers on 
your network.   
2. Press the SETUP front panel key to the left of the analyzer's display.  
3. In the softkey menu opened, press General Setup – Network Address– DHCP: Off.  
4. Enter your IP-Address and Subnet Mask. 
To enter additional IP address information, you have to access the operating system of 
the R&S ZVL. 
6. Access Windows XP using an external keyboard; see Accessing Window XP's Start Menu.  
7. Open the Control Panel – Network Connections – Local Area Connection Status – Local Area 
Connection Properties – Internet Protocol (TCP/IP) Properties dialog and enter the complete address 
information, e.g.: 
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Provides you with examples for adding an (empty) page to a PDF and adding empty pages to a PDF XDoc.PDF allows you to easily move PDF document pages position
add page numbers to pdf in preview; adding page numbers pdf file
VB.NET PDF insert text library: insert text into PDF content in vb
VB.NET PDF - Insert Text to PDF Document in VB.NET. Providing Demo Code for Adding and Inserting Text to PDF File Page in VB.NET Program.
add page to pdf preview; add page numbers to a pdf in preview
R&S
®
ZVL 
Preparing for Use 
Remote Control in a LAN 
Quick Start Guide 1303.6538.62-01 
35 
For more information refer to the Windows XP Help.  
1.7.2 Remote Desktop Connection 
Remote Desktop is a Windows application which can be used to access and control 
the analyzer from a remote computer through a LAN connection. While the 
measurement is running, the analyzer screen contents are displayed on the remote 
computer, and Remote Desktop provides access to all of the applications, files, and 
network resources of the analyzer.  
To set up a Remote Desktop connection  
1. Connect the analyzer to a LAN and determine its IP address; see Remote Control 
in a LAN.  
2. Set up your remote computer (integrated in the LAN) to use Remote Desktop and 
create the Remote Desktop connection to the analyzer.  
For detailed information about Remote Desktop and the connection refer to the 
Windows XP Help.  
C# PDF Annotate Library: Draw, edit PDF annotation, markups in C#.
text comments on PDF page using C# demo code in Visual Stuodio .NET class. C#.NET: Add Text Box to PDF Document. Provide users with examples for adding text box
add page number to pdf document; add and delete pages from pdf
C# PDF Library SDK to view, edit, convert, process PDF file for C#
Capable of adding PDF file navigation features to your C# program. Perform annotation capabilities to mark, draw, and visualize objects on PDF document page.
add document to pdf pages; adding page numbers to pdf files
R&S
®
ZVL 
Preparing for Use 
Windows XP 
Quick Start Guide 1303.6538.62-01 
36 
1.8 Windows XP 
The analyzer is equipped with a Windows XP operating system which has been 
configured according to the instrument's features and needs. Changes in the system 
configuration can be necessary in order to  
Establish a LAN connection  
Customize the properties of the external accessories connected to the analyzer  
Call up additional software tools  
ATTENTION 
Operating system settings  
The operating system is adapted to the network analyzer. To avoid impairment of 
instrument functions, only change the settings described in this manual. Existing 
software must be modified only with update software released by Rohde & Schwarz. 
Likewise, only programs authorized by Rohde & Schwarz for use on the instrument 
must be executed.  
The Start menu of the operating system is accessed as described below. All necessary 
settings can be accessed from the Start menu, in particular from the Control Panel.   
1.8.1 Accessing Windows XP's Start Menu 
The Windows XP Start menu provides access to the Windows XP functionality and 
installed programs. From the start menu, you can navigate to the submenus by using 
the mouse or the cursor keys of the keyboard.  
The following operations require an external keyboard.  
To open the Windows XP Start menu,  
On your keyboard, press the Windows key or the CTRL+ESC key combination.  
To return to the measurement screen use one of the following methods: 
Press the ALT+TAB key combination to switch to the analyzer application.  
In the Windows task bar (opened via ALT + Tab), click the "R&S Analyzer 
Interface" icon. 
R&S
®
ZVL 
Preparing for Use 
Firmware Update 
Quick Start Guide 1303.6538.62-01 
37 
1.9 Firmware Update 
Upgrade versions of the analyzer firmware are supplied as setup files (*msi). To 
perform a firmware update, you can either use the softkeys associated with the SETUP 
front panel key or the Instrument_Update_Tool. The latter procedure is recommended 
if installation via SETUP is not practicable.  
NOTE 
Setup files  
To prepare the installation , copy the setup file to any storage medium accessible from 
the analyzer. This may be the internal hard disk, an external storage medium (USB 
memory stick, CD-ROM with external drive) or a network connection (LAN, GPIB bus).
To install new fimware using the SETUP menu, 
1. Press SETUP > More > Firmware Update and open the Firmware Update dialog 
box.  
2. Enter the update path of your firmware, depending on the installation medium that 
you use. You can also Browse… the update path in the dialog.  
3. Click Execute to start the installation.  
The installation program will guide you through the installation. If installation fails, use 
the Instrument_Update_Tool as described below.  
Setup files can be stored and installed again. The default drive name of the USB 
interfaces is C:. External storage devices are automatically mapped to the next free 
drive, i.e. D:, E: etc.   
Remote control: SYST:FIRM:UPD 'D:\FW_UPDATE' 
To install new fimware using the update tool, 
1. Close all applications.  
2. Access Window XP’s startup menu as described in section Accessing Windows 
XP's Start Menu on p. 36.  
3. Select Programs > Accessories > Instrument_Update_Tool.  
4. In the dialog box opened, select the ZVL.package file and click Open.  
5. In the Install Manager dialog box opened, click Install.  
R&S
®
ZVL 
Getting Started 
Reflection Measurements 
Quick Start Guide 1303.6538.62-01 
39 
2 Getting Started...................................................................................40 
2.1
Reflection Measurements..........................................................................................40
2.1.1
Instrument Setup for Reflection Measurements...........................................................40
2.1.2
Parameter and Sweep Range Selection......................................................................41
2.1.3
Instrument Calibration...................................................................................................42
2.1.4
Evaluation of Data........................................................................................................44
2.1.5
Saving and Printing Data..............................................................................................45
2.2
Basic Tasks.................................................................................................................47
2.2.1
Control via Front Panel Keys........................................................................................47
2.2.2
Data Entry.....................................................................................................................49
2.2.3
Scaling Diagrams..........................................................................................................51
R&S
®
ZVL 
Getting Started 
Reflection Measurements 
Quick Start Guide 1303.6538.62-01 
40 
2 Getting Started    
The following chapter presents a sample session with a R&S ZVL network analyzer 
and explains how to solve basic tasks that you will frequently encounter when working 
with the instrument.  
CAUTION 
General safety instructions 
Before starting any measurement on your network analyzer, please note the 
instructions given in Chapter Preparing for Use. 
In the System Overview you will find detailed information on customizing the 
instrument and the display according to your personal preferences. For a systematic 
explanation of all menus, functions and parameters and background information refer 
to the reference chapters in the online help system.  
NOTE 
Windows operation 
In the following we assume that you are familiar with standard Windows dialogs and 
mouse operation. Refer to sections Using Front Panel Keys and Data Entry to learn 
how to access instrument functions and control dialogs without a mouse and 
keyboard.  
2.1 Reflection Measurements     
In a reflection measurement, the analyzer transmits a stimulus signal to the input port 
of the device under test (DUT) and measures the reflected wave. A number of trace 
formats allow you to express and display the results. depending on what you want to 
learn from the data. Only one analyzer test port is required for reflection 
measurements.  
In the following example, the analyzer is set up for a reflection measurement, a 
frequency sweep range and measurement parameter is selected, the instrument is 
calibrated and the result is evaluated using various formats.   
2.1.1 Instrument Setup for Reflection Measurements 
In order to prepare a reflection measurement, you have to connect your DUT (which is 
assumed to have a male N 50 Ω connector) to one of the (equivalent) analyzer test 
ports. Besides, it is recommended to preset the instrument in order to set it to a 
definite, known state.  
Documents you may be interested