c# free pdf viewer : Add page number to pdf print SDK application service wpf windows web page dnn R&S%20ZVL-MANUAL31-part754

R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
311 
CALCulate<Chn>:LIMit:SOUNd[:STATe]  
Switches the acoustic signal (fail beep) on or off. The fail beep is generated each time the analyzer 
detects an exceeded limit.  
<Chn> 
Channel number used to identify the active trace.   
<Boolean> 
ON | OFF - Fail beep on or off.  
*RST value 
OFF  
SCPI, Command Types 
Confirmed, command or query.   
Example: 
CALC:LIM:STAT ON; SOUN ON  
Switch the limit check on and activate the fail beep.   
CALCulate<Chn>:LIMit:STATe  
Switches the limit check (including upper and lower limits) on or off.  
Use CALCulate<Chn>:LIMit:UPPer:STATe or CALCulate<Chn>:LIMit:LOWer: 
STATe to switch on or off the individual limit checks for upper or lower limit lines.  
<Chn> 
Channel number used to identify the active trace.   
<Boolean> 
ON | OFF - Limit check on or off.  
*RST value 
OFF  
SCPI, Command 
Types 
Confirmed, command or query.   
Example: 
*RST; CALC:LIM:CONT 1 GHZ, 2 GHZ  
Define an upper limit line segment in the stimulus range between 1 GHz and 2 
GHz, using default response values.  
CALC:LIM:STAT ON; CALC:LIM:FAIL?  
Switch the limit check on and query the result.   
CALCulate<Chn>:LIMit:UPPer[:DATA] 
<numeric_value>,<numeric_value>{,<numeric_value>,<numeric_value>}  
Defines the response (y-axis) values of the upper limit line and/or creates new limit line segments.  
The 
commands 
CALCulate<Chn>:LIMit:LOWer[:DATA] 
and 
CALCulate<Chn>:LIMit:UPPer[:DATA] use a fixed numbering scheme for limit line 
segments: Upper limit line segments are assigned odd numbers (1, 3, 5,...), lower limit line 
segments are assigned even numbers (2, 4, 6,...).   
Add page number to pdf print - insert pages into PDF file in C#.net, ASP.NET, MVC, Ajax, WinForms, WPF
Guide C# Users to Insert (Empty) PDF Page or Pages from a Supported File Format
add pages to pdf acrobat; adding a page to a pdf file
Add page number to pdf print - VB.NET PDF Page Insert Library: insert pages into PDF file in vb.net, ASP.NET, MVC, Ajax, WinForms, WPF
Easy to Use VB.NET APIs to Add a New Blank Page to PDF Document
add page number to pdf reader; adding page numbers to pdf document
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
312 
Rules for creating segments 
The following rules apply to an active trace with n existing upper and n existing lower limit line segments: 
• An odd number of values is rejected; an error message –109,"Missing parameter..." is generated.  
• An even number of 2*k values updates or generates k upper limit line segments.  
• For n > k the response values of all existing upper limit line segments no. 1, 3, ...,2*k–1 are 
updated, the existing upper and lower limit line segments no. 2*k+1, ..., 2*n are deleted. The 
existing lower limit line segments no. 2, 4, 2*k are not affected.  
• For n < k the response values of the upper limit line segments no. 1, 3 to 2*n–1 are updated, the 
upper limit line segments 2*n+1, 2*n+3,..., 2*k–1 are generated with default stimulus values (see 
CALCulate<Chn>:LIMit:CONTrol[:DATA]. In addition, the missing lower limit line segments 
2*n+2, 2*n+4,..., 2*k are generated with default stimulus and response values  
<Chn> 
Channel number used to identify the active trace.  
<numeric_value> 
Pair(s) of response values.  
Range [def. unit] 
Almost no restriction for limit segments; see Rules for Limit Line Definition. [dB] 
*RST value 
– 
The response value of a segment that is created implicitly, e.g. an lower limit 
line segment, is –20 dB.   
SCPI, Command 
Types 
Confirmed, with query.  
Example: 
CALC:LIM:UPP -10, 0, 0, -10  
Define the following upper and (default) lower limit line segments: 
CALC:LIM:DISP ON 
Show the limit line segments in the active diagram.  
CALCulate<Chn>:LIMit:UPPer:FEED  
Generates an upper limit line using the stimulus values of a data or memory trace and specified offset 
values.   
<Chn> 
Channel number used to identify the active trace. This trace provides the 
stimulus data for the limit line unless another trace <trace_name> is 
specified.  
<stimulus_offset> 
Stimulus offset value, used to shift all imported limit line segments in 
horizontal direction.  
Range [def. unit] 
-1000 GHz to +1000 GHz [Hz]  
*RST value 
0 Hz 
C# PDF insert text Library: insert text into PDF content in C#.net
pageIndex, The page index of the PDF page that will be 0
add page numbers to pdf online; add page numbers to pdf in reader
C# PDF File Split Library: Split, seperate PDF into multiple files
If your page number is set as 1, then the two output PDF files will contains the first page and the later three pages Add necessary references:
adding page to pdf in preview; add pdf pages together
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
313 
<response_offset> 
Response offset value, used to shift all imported limit line segments in vertical 
direction.  
Range [def. unit] 
-10
12
dB to +10
12
dB [dB]  
*RST value 
0 dB 
<trace_name> 
Name of the selected trace as used e.g. in 
CALCulate<Ch>:PARameter:SDEFine. If no trace name is specified the 
analyzer uses the active trace no. <Chn>.  
SCPI, Command 
Types 
Device-specific, no query.  
Example: 
CALC:LIM:UPP:FEED 1 GHZ, 10  
Use the stimulus values of the active trace, shifted by 1 GHz to the right and 
increased by 10 dB, to create an upper limit line.  
CALC:LIM:UPP:SHIF 3; CALC:LIM:CONT:SHIF 1 GHz 
Shift the limit line by an additional 3 dB in vertical and by 1 GHz in horizontal 
direction. If a lower limit line exists it is also shifted.  
CALCulate<Chn>:LIMit:UPPer:SHIFt <numeric_value> 
Shifts all lower and upper limit line segments assigned to the active trace in vertical direction.   
This command is identical with CALCulate<Chn>:LIMit:LOWer:SHIFt.  
<Chn> 
Channel number used to identify the active trace.   
<numeric_value> 
Response offset value for all limit line segments.  
Range [def. unit] 
Almost no restriction for limit segments; see Rules for Limit Line Definition. 
[dB]  
*RST value 
–  
SCPI, Command 
Types 
Device-specific, no query.  
Example: 
See CALCulate<Chn>:LIMit:UPPer:FEED.  
CALCulate<Chn>:LIMit:UPPer:STATe <Boolean> 
Switches the upper limit check on or off. Upper limit line segments are assigned odd numbers; see 
CALCulate<Chn>:LIMit:UPPer[:DATA]. The command does not affect segments with even 
numbers.  
Use CALCulate<Chn>:LIMit:STATe to switch on or off the entire limit check, including 
upper and lower limit lines.  
<Chn> 
Channel number used to identify the active trace.   
<Boolean> 
ON | OFF - Limit check on or off.  
*RST value 
OFF  
VB.NET PDF File Split Library: Split, seperate PDF into multiple
can split target multi-page PDF document file to one-page PDF files or PDF file to smaller PDF documents by every given number of pages Add necessary references
adding page numbers to pdf in; add a page to a pdf in acrobat
C# PDF Print Library: Print PDF documents in C#.net, ASP.NET
Image: Copy, Paste, Cut Image in Page. Link: Edit Text. Add Text Box. Drawing Markups. Add Stamp Annotation. variety of printing options, like like number of copies
add page to pdf in preview; add page to pdf acrobat
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
314 
SCPI, Command 
Types 
Confirmed, command or query.   
Example: 
CALC:LIM:UPP -10, 0, 0, -10  
Define the following upper and (default) lower limit line segments: 
CALC:LIM:UPP:STAT ON; CALC:LIM:FAIL?  
Switch the limit check on and query the result.   
CALCulate:MARKer 
CALCulate<Chn>:MARKer<Mk>...     
This subsystem controls the marker functions. The commands are device-specific and beyond what is 
specified in the SCPI subsystem SOURce:MARKer.  
CALCulate<Chn>:MARKer<Mk>:AOFF 
Removes all markers from all traces of the active setup. The removed markers remember their properties 
(stimulus value, format, delta mode, number) when they are restored (CALC<Chn>:MARK<Mk> ON). The 
marker properties are definitely lost if the associated trace is deleted.  
<Chn> 
Channel number used to identify the active trace. If unspecified the numeric 
suffix is set to 1.   
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may 
be set to any value.   
*RST value 
–  
SCPI, Command 
Types 
Device-specific, no query.   
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK1 ON; MARK2 ON   
Create markers 1 and 2 and assign them to the trace no. 1. 
CALC:MARK:AOFF   
Remove both markers.  
C# PDF Text Search Library: search text inside PDF file in C#.net
Add necessary references: Description: Search specified string from all the PDF pages. eg: The first page is 0. 0
adding page numbers to a pdf document; adding page numbers to pdf in reader
C# PDF File & Page Process Library SDK for C#.net, ASP.NET, MVC
Highlight Text. Add Text. Add Text Box. Drawing Markups. PDF to Jpeg, VB.NET compress PDF, VB.NET print PDF, VB.NET Please note that, PDF page number starts from
add multi page pdf to word document; add or remove pages from pdf
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
315 
CALCulate<Chn>:MARKer<Mk>:BWIDth <x_dB_Bandwidth> 
Sets the bandfilter level for a bandfilter search or returns the results. The command is only available after 
a bandfilter search has been executed (CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute 
BFILter; see example below).  
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may 
be set to any value because the bandfilter search functions always use 
markers Mkr1 to Mkr4.  
<x_dB_Bandwidth> 
x dB Bandwidth parameter. The x dB Bandwidth is the difference between 
the band edges and the center response value of a bandfilter peak; it must be 
negative for a bandpass search and positive for a bandstop search.  
Range [def. unit] 
For bandpass: –100.00 dB to –0.01 dB, the increment (UP/DOWN) is 0.3 dB. 
[dB] 
For bandstop: +0.01 dB to +100.00 dB, the increment (UP/DOWN) is 0.3 dB. 
[dB] 
*RST value 
–3 dB 
Response for 
query: 
Search result in the format <Bandwidth>, <Center_Stimulus>, <Q>, <Loss>, 
<LBE>, <UBE> where: 
<Bandwidth> 
n-dB bandwidth of the bandpass/bandstop region, where n is the selected 
dB Bandwidth (setting command CALCulate<Chn>:MARKer<Mk>:BWIDth 
<x dB Bandwidth>).  
<Center_Stimulus> 
Stimulus frequency at the center of the bandpass/bandstop region (the 
stimulus value of marker no. 4). 
<Q> 
Quality factor, i.e. the ratio between the center frequency and the 3-dB 
bandwidth 
<Loss> 
Loss at the center of the bandpass/bandstop region (the response value of 
marker no. 4 at the time of the bandfilter search).  
<LBE> 
Lower band edge 
<UBE> 
Upper band edge 
Range [def. unit] 
Depending on the measurement parameter. [units depending on the sweep 
type and the marker format; see CALCulate<Chn>:MARKer<Mk>:FORMat] 
*RST value 
–  
SCPI, Command 
Types 
Device-specific, query only.  
Example: 
CALC:MARK:FUNC:BWID:MODE BST  
Select a bandstop filter search.  
CALC:MARK:FUNC:EXEC BFIL  
Initiate the bandpass filter search for the current trace. Create markers 1 to 4. 
CALC:MARK:SEAR:BFIL:RES ON  
Display the marker info field in the diaram area.  
CALC:MARK:BWID 6  
Select a 6-dB bandwidth for the bandstop.  
CALC:MARK:BWID?  
Query the results of the bandfilter search. An error message is generated if 
C# PDF delete text Library: delete, remove text from PDF file in
Add necessary references: RasterEdge.Imaging.Basic.dll. matchString, The string wil be deleted from PDF file, -. 0
add page numbers pdf; add page to a pdf
C# PDF Text Highlight Library: add, delete, update PDF text
200F); annot.EndPoint = new PointF(300F, 400F); // add annotation to The string wil be highlighted from PDF file, 0
add page numbers to pdf reader; add pdf pages to word document
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
316 
the bandfilter search fails so that no valid results are available.  
 
CALCulate<Chn>:MARKer<Mk>:COUPled[:STATe] <Boolean> 
Couples the markers of all traces in the active setup to the markers of trace no. <Chn>, provided that they 
have the same sweep type (SENSe<Chn>:FUNCtion).  
<Chn> 
Channel number used to identify the active trace. The effects of marker coupling 
depend on the active trace number; see Coupled Markers in the GUI Reference 
chapter.  
<Mk> 
Marker number in the range 1 to 10. This suffix is ignored because the command 
affects all markers.   
<Boolean> 
ON | OFF - Enables or disables marker coupling.   
*RST value 
OFF   
SCPI, 
Command 
Types 
Device-specific, command or query.   
Example: 
Suppose that the active setup contains two traces Trc1 and Trc2, assigned to 
channels no. 1 and 2, respectively.  
:CALC1:PAR:SEL 'TRC1'; CALC1:MARK1 ON; MARK2 ON  
Select Trc1 as the active trace and create the two markers no. 1 and 2. The 
default position for both markers is the center of the sweep range.  
CALC1:MARK:COUP ON  
Create two markers no. 1 and 2 on Trc 2 and couple them to the markers of Trc 1. 
CALCulate<Chn>:MARKer<Mk>:DELTa[:STATe] <Boolean> 
Switches the delta mode for marker <Mk> on trace no. <Chn> on or off. The marker must be created 
before using CALCulate<Chn>:MARKer<Mk>[:STATe] ON. If the active trace contains no reference 
marker, the command also creates a reference marker.   
<Chn> 
Channel number used to identify the active trace.   
<Mk> 
Marker number in the range 1 to 10.   
<Boolean> 
ON | OFF - Enables or disables the delta mode.  
*RST value 
OFF   
SCPI, Command 
Types 
Device-specific, command or query.   
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK ON  
Create marker no. 1 and set it to the center of the sweep range.  
CALC:MARK:DELT ON  
C# WPF PDF Viewer SDK to print PDF document in C#.NET
Highlight Text. Add Text. Add Text Box. Drawing Markups. Add Stamp Annotation. PDF Able to print a single PDF page. Provide the ability to select number of copies
adding page to pdf; add page to existing pdf file
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
317 
Create a reference marker at the center of the sweep range and set marker 1 
to delta mode.   
CALCulate<Chn>:MARKer<Mk>:FORMat MLINear | MLOGarithmic | PHASe | POLar 
| COMPlex | GDELay | REAL | IMAGinary | SWR | LINPhase | LOGPhase | 
IMPedance | ADMittance | MDB | MLPHase | MDPHase 
Defines the output format for the (complex) value of marker <Mk> on trace no. <Chn>. 
Note:  
The formats of the markers assigned to a trace are independent of each other and of the 
trace format settings; see CALCulate<Chn>:FORMat.  
<Chn> 
Channel number used to identify the active trace.  
<Mk> 
Marker number in the range 1 to 10.   
Parameters 
See list of parameters below. 
*RST value 
DEF – This means the format of the trace no. <Chn> (MLOG after *RST); see 
CALCulate<Chn>:FORMat. 
SCPI, Command 
Types 
Device-specific, command or query 
Example: 
Suppose that the active setup contains an active trace no. 1.  
CALC:MARK ON; CALC:MARK:FORM?  
Create marker 1, assign it to the trace no. 1 and query its format. The analyzer 
returns the format of the active trace.  
Assume that the marker result is given by the complex quantity z = x + jy. The meaning of the parameters 
is as follows:  
MLINear  
|z| = sqrt ( x2 + y2 )   
MLOGarithmic 
MDB 
|z| = sqrt ( x2 + y2 )  
dB Mag(z) = 20 * log|z| dB  
PHASe  
φ (z) = arctan ( Im(z) / Re(z) )  
POLar  
COMPlex 
x, y (Real and Imag)  
GDELay 
Group Delay, – d φ (z)/dω 
REAL 
x  
IMAGinary  
y  
SWR 
Standing Wave Ratio, SWR = (1 + |z|) / (1 – |z|) 
LINPhase 
MLPhase 
Lin Mag and Phase, |z|, arctan ( Im(z) / Re(z) )  
LOGPhase 
MDPhase 
dB Mag and Phase, 20 * log|z| dB, arctan ( Im(z) / Re(z) ) 
IMPedance 
R, X, L or C (depending on sign(X))  
ADMittance 
G, B, L/C (depending on sign(X)) 
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
318 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth <x dB Bandwidth> 
Defines the bandfilter level, i.e. the minimum excursion for the bandpass and bandstop peaks.   
Use CALCulate<Chn>:MARKer<Mk>:BWIDth to set the x dB Bandwidth and query the 
results of a bandfilter search. Note the sign convention for input values.  
<Chn> 
Channel number used to identify the active trace.  
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may be set 
to any value because the bandfilter search functions always use markers Mkr1 to 
Mkr4. 
<x dB 
Bandwidth> 
x dB Bandwidth parameter.  
Range [def. unit] 
0.01 dB to 100.00 dB, the increment (UP. DOWN) is 0.3 dB. [dB]   
*RST value 
3 dB. 
SCPI, 
Command 
Types 
Device-specific, command or query.  
Example: 
See CALCulate<Chn>:MARKer<Mk>:BWIDth.  
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE BPASs | BSTop | 
BPRMarker | BSRMarker 
Selects the bandfilter search mode.  
<Chn> 
Channel number used to identify the active trace.  
<Mk> 
Marker number in the range 1 to 10. This numeric suffix is ignored and may be set 
to any value because the bandfilter search functions always use markers Mkr1 to 
Mkr4. 
Parameters 
Bandfilter search type:  
BPASs: Bandpass Search Ref to Max 
BSTop: Bandstop Search Ref to Max  
BPRMarker: Bandpass Search Ref to Marker 
BSRMarker: Bandstop Search Ref to Marker  
*RST value 
BPASs 
SCPI, 
Command 
Types 
Device-specific, command or query.  
Example: 
See CALCulate<Chn>:MARKer<Mk>:BWIDth.  
CALCulate<Chn>:MARKer<Mk>:FUNCtion:CENTer 
Sets the center of the sweep range equal to the stimulus value of the marker <Mk> on trace no. <Chn>.  
<Chn> 
Channel number used to identify the active trace. 
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
319 
<Mk> 
Marker number in the range 1 to 10.  
Range [def. unit] 
– [–]  
*RST value 
– 
SCPI, Command 
Types 
Device-specific, no query.  
Example: 
*RST; CALC:MARK ON   
Create marker 1 in the center of the current sweep range and assign it to 
trace no. 1.   
CALC:MARK:FUNC:CENT  
Leave the sweep range unchanged. 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DELTa[:STATe] <Boolean> 
Switches the delta mode for marker <Mk> on trace no. <Chn> on or off.  
Note:  This command is the ZVR-compatible equivalent of 
CALCulate<Chn>:MARKer<Mk>:DELTa[:STATe].  
<Chn> 
Channel number used to identify the active trace.   
<Mk> 
Marker number in the range 1 to 10.   
<Boolean> 
ON | OFF - Enables or disables the delta mode.  
*RST value 
OFF   
SCPI, Command Types 
Device-specific, command or query.   
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER <numeric_value> 
Assigns a search range no. <numeric_value> to marker no <Mk> and selects the search range, e.g. in 
order to define the start and stop values.  
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.  
<numeric_value> 
Number of the search range.  
Range [def. unit] 
0 – fixed full span search range (equal to the sweep range)  
1 to 10 – user-definable search ranges; see example   
*RST value 
0 (reserved for full span search range) 
SCPI, Command Types 
Device-specific, command or query.  
Example: 
CALC1:MARK1:FUNC:DOM:USER 2  
Select the search range no. 2, assigned to marker no. 1 and trace no. 1. 
CALC:MARK:FUNC:DOM:USER:STARt 1GHz  
Set the start frequency of the search range to 1 GHz. 
CALC:MARK:FUNC:DOM:USER:STOP 1.2GHz 
Set the stop frequency of the search range to 1.2 GHz. 
R&S
®
ZVL 
Command Reference 
CALCulate 
Operating Manual 1303.6580.32-01 
320 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt <numeric_value> 
Defines the start value of the search range selected with 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER <numeric_value>.  
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.  
<numeric_value> 
Beginning of the search range.  
Range [def. unit] 
Maximum allowed sweep range, depending on the instrument model and on 
the sweep type. [Hz, dBm or s, depending on the sweep type]  
*RST value 
0 Hz  
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
See CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER <numeric_value> 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP <numeric_value> 
Defines the stop value of the search range selected with 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER <numeric_value>.  
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10.  
<numeric_value> 
End of the search range.  
Range [def. unit] 
Maximum allowed sweep range, depending on the instrument model and on 
the sweep type. [Hz, dBm or s, depending on the sweep type]  
*RST value 
0 Hz  
SCPI, Command 
Types 
Device-specific, command or query.  
Example: 
See CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER <numeric_value> 
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute MAXimum | MINimum | RPEak 
| LPEak | NPEak | TARGet | LTARget | RTARget | BFILter 
Selects a search mode for marker no. <Mk> and initiates the search. The marker must be created before 
using CALCulate<Chn>:MARKer<Mk>[:STATe] ON (exception: bandfilter search).  
<Chn> 
Channel number used to identify the active trace. 
<Mk> 
Marker number in the range 1 to 10. For a bandfilter search (BFILter) this 
numeric suffix is ignored and may be set to any value because the bandfilter 
search functions always use markers Mkr1 to Mkr4. 
Parameters 
See list of parameters below.  
*RST value 
– 
Documents you may be interested
Documents you may be interested